American Journal of Obstetrics and... Feb 2022This study aimed to review pregnancy hypertension clinical practice guidelines to inform international clinical practice and research priorities.
OBJECTIVE
This study aimed to review pregnancy hypertension clinical practice guidelines to inform international clinical practice and research priorities.
STUDY ELIGIBILITY CRITERIA
Relevant national and international clinical practice guidelines, 2009-19, published in English, French, Dutch or German.
STUDY APPRAISAL AND SYNTHESIS METHODS
Following published methods and prospective registration (CRD42019123787), a literature search was updated. CPGs were identified by 2 authors independently who scored quality and usefulness for practice (Appraisal of Guidelines for Research and Evaluation II instrument), abstracted data, and resolved any disagreement by consensus.
RESULTS
Of note, 15 of 17 identified clinical practice guidelines (4 international) were deemed "clinically useful" and had recommendations abstracted. The highest Appraisal of Guidelines for Research and Evaluation II scores were from government organizations, and scores have improved over time. The following were consistently recommended: (1) automated blood pressure measurement with devices validated for pregnancy and preeclampsia, reflecting increasing recognition of the prevalence of white-coat hypertension and the potential usefulness of home blood pressure monitoring; (2) use of dipstick proteinuria testing for screening followed by quantitative testing by urinary protein-to-creatinine ratio or 24-hour urine collection; (3) key definitions and most aspects of classification, including a broad definition of preeclampsia (which includes proteinuria and maternal end-organ dysfunction, including headache and visual symptoms and laboratory abnormalities of platelets, creatinine, or liver enzymes) and a recognition that it can worsen after delivery; (4) preeclampsia prevention with aspirin; (5) treatment of severe hypertension, most commonly with intravenous labetalol, oral nifedipine, or intravenous hydralazine; (6) treatment for nonsevere hypertension when undertaken, with oral labetalol (in particular), methyldopa, or nifedipine, with recommendations against the use of renin-angiotensin-aldosterone inhibitors; (7) magnesium sulfate for eclampsia treatment and prevention among women with "severe" preeclampsia; (8) antenatal corticosteroids for preterm birth but not hemolysis, elevated liver enzymes, and low platelet count syndrome; (9) delivery at term for preeclampsia; (10) a focus on usual labor and delivery care but avoidance of ergometrine; and (11) an appreciation that long-term health complications are increased in incidence, mandating lifestyle change and risk factor modification. Lack of uniformity was seen in the following areas: (1) the components of a broad preeclampsia definition (specifically respiratory and gastrointestinal symptoms, fetal manifestations, and biomarkers), what constitutes severe preeclampsia, and whether the definition has utility because at present what constitutes severe preeclampsia by some guidelines that mandate proteinuria now defines any preeclampsia for most other clinical practice guidelines; (2) how preeclampsia risk should be identified early in pregnancy, and aspirin administered for preeclampsia prevention, because multivariable models (with biomarkers and ultrasonography added to clinical risk markers) used in this way to guide aspirin therapy can substantially reduce the incidence of preterm preeclampsia; (3) the value of calcium added to aspirin for preeclampsia prevention, particularly for women with low intake and at increased risk of preeclampsia; (4) emerging recommendations to normalize blood pressure with antihypertensive agents even in the absence of comorbidities; (5) fetal neuroprotection as an indication for magnesium sulfate in the absence of "severe" preeclampsia; and (6) timing of birth for chronic and gestational hypertension and preterm preeclampsia.
CONCLUSION
Consistent recommendations should be implemented and audited. Inconsistencies should be the focus of research.
Topics: Anticonvulsants; Antihypertensive Agents; Aspirin; Calcium; Delivery, Obstetric; Female; Glucocorticoids; Humans; Hypertension, Pregnancy-Induced; Magnesium Sulfate; Platelet Aggregation Inhibitors; Practice Guidelines as Topic; Pre-Eclampsia; Pregnancy; Proteinuria; Risk Assessment
PubMed: 32828743
DOI: 10.1016/j.ajog.2020.08.018 -
Iranian Journal of Kidney Diseases May 2016During the past decade, using serum biomarkers and clinical decision rules for early prediction of rhabdomyolysis-induced acute kidney injury (AKI) has received much... (Meta-Analysis)
Meta-Analysis Review
INTRODUCTION
During the past decade, using serum biomarkers and clinical decision rules for early prediction of rhabdomyolysis-induced acute kidney injury (AKI) has received much attention from researchers. This study aimed to broadly review the value of scoring systems and urine dipstick in prediction of rhabdomyolysis-induced AKI.
MATERIALS AND METHODS
The study was designed based on the guidelines of the Meta-analysis of Observational Studies in Epidemiology statement. Search was done in electronic databases of MEDLINE, EMBASE, Cochrane Library, Scopus, and Google Scholar by 2 independent reviewers. Studies evaluating AKI risk factors in rhabdomyolysis patients with the aim of developing a scoring model as well as those assessing the role of urine dipstick in these patients were included.
RESULTS
Of the 5997 articles found, 143 were potentially relevant studies. After studying their full texts, 6 articles were entered into the systematic review. Two studies had developed or validated scoring systems of the "rule of thumb," and the AKI index, and the Mangled Extremity Severity Score. Four studies were on the predictive value of urine dipstick in risk prediction of rhabdomyolysis-induced AKI, with favorable results.
CONCLUSIONS
The findings of this systematic review showed that based on the available resources, using the prediction rules and urine dipstick could be considered as valuable screening tools for detection of patients at risk for AKI following rhabdomyolysis. Yet, the external validity of the mentioned tools should be assessed before their general application in routine practice.
Topics: Acute Kidney Injury; Biomarkers; Humans; Observational Studies as Topic; Reagent Strips; Rhabdomyolysis; Risk Assessment; Severity of Illness Index; Urinalysis
PubMed: 27225716
DOI: No ID Found -
Pregnancy Hypertension Mar 2022Dipstick tests are frequently used as bedside proteinuria tests to evaluate women suspected of preeclampsia and may inform diagnosis in low resource settings lacking... (Meta-Analysis)
Meta-Analysis
OBJECTIVES
Dipstick tests are frequently used as bedside proteinuria tests to evaluate women suspected of preeclampsia and may inform diagnosis in low resource settings lacking laboratory facilities. This systematic review and meta-analysis aimed to (1) estimate the diagnostic accuracy of urine dipsticks in diagnosing proteinuria, (2) compare performance of different dipstick types and (3) estimate their related costs.
METHODS
MEDLINE and EMBASE were searched up to August 1, 2020 for primary studies with cross-sectional diagnostic accuracy data on dipstick test(s) compared to a laboratory reference standard (24-hour protein ≥ 300 mg or protein-creatinine ratio ≥ 30 mg/mmol) in pregnant women ≥ 20 weeks of gestation suspected of preeclampsia. Risk of bias and applicability was assessed with QUADAS-2. Data were analysed using a bivariate model with hierarchical addition of covariates for subgroups.
RESULTS
Nineteen studies were included. Protein-only dipsticks at 1 + threshold had a pooled sensitivity of 0.68 [95%CI: 0.57-0.77] and specificity of 0.85 [95% CI: 0.73-0.93] (n = 3700 urine samples, 18 studies). Higher specificity was found with automatedly (0.93 [95% CI: 0.82-0.98]) compared to visually (0.81 [95% CI: 0.65-0.91]) read dipsticks, whereas sensitivity was similar and costs were higher. The use of albumin-creatinine ratio (ACR) dipsticks was only reported in two studies and did not improve accuracy. Heterogeneity in study design and prevalence of preeclampsia amongst studies complicated interpretation of pooled estimates.
CONCLUSION
Urine dipsticks performed poorly at excluding preeclampsia in hypertensive pregnant women. Further development of accurate and low-cost bedside proteinuria tests is warranted.
Topics: Female; Humans; Point-of-Care Testing; Pre-Eclampsia; Pregnancy; Proteinuria; ROC Curve; Reagent Strips
PubMed: 35051804
DOI: 10.1016/j.preghy.2021.12.015 -
Clinical Microbiology and Infection :... Feb 2022Cholera is an acute diarrheal disease caused by Vibrio cholerae O1 or O139. Cholera rapid diagnostic tests (RDTs) are widely used to screen for cholera cases. However,... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Cholera is an acute diarrheal disease caused by Vibrio cholerae O1 or O139. Cholera rapid diagnostic tests (RDTs) are widely used to screen for cholera cases. However, their accuracy has not been systematically reviewed.
OBJECTIVES
To evaluate the diagnostic accuracy of cholera RDTs.
METHODS
Systematic review and meta-analysis.
DATA SOURCES
Medline, EMBASE and Web of science through to November 2020; references of included studies and a technical guidance on cholera RDTs. This review is registered with PROSPERO (CRD42021233124).
STUDY ELIGIBILITY CRITERIA
Cross-sectional studies comparing the performance of cholera RDTs either to stool culture or PCR.
PARTICIPANTS
Individuals with clinically suspected cholera.
DATA EXTRACTION
Two authors independently extracted data and assessed the quality using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) criteria.
RESULTS
Eighteen studies were included in the systematic review of which 17 were used for meta-analysis. Crystal VC was the most frequently used RDT (13 studies), followed by Cholkit and Institut Pasteur cholera dipstick (three studies each), SD Bioline (two studies), Artron (one study) and Smart (one study). Using direct testing (n = 12 627 specimens), the bivariate random-effects model yielded a pooled sensitivity and specificity of 91% (95% CI 87%-94%) and 80% (95% CI 74%-84%), respectively. However, through alkaline peptone water (APW) enrichment (n = 3403 specimens), the pooled sensitivity and specificity were 89% (95% CI 79%-95%) and 98% (95% CI 95%-99%), respectively.
CONCLUSION
Cholera RDTs, especially when enriched with APW, have moderate sensitivity and specificity. Although less useful for clinical management, the current generation of RDTs have clear utility for surveillance efforts if used in a principled manner. Enrichment of stool specimens in APW before using cholera RDTs reduces the possibility of obtaining false-positive results, despite the few cholera cases that go undetected. It is noteworthy that APW-enriched cholera RDTs are not necessarily rapid tests, and are not listed in the Global Task Force on Cholera Control/WHO target product profile.
Topics: Cholera; Cross-Sectional Studies; Humans; Reagent Kits, Diagnostic; Sensitivity and Specificity; Vibrio cholerae O1
PubMed: 34506946
DOI: 10.1016/j.cmi.2021.08.027 -
Acta Paediatrica (Oslo, Norway : 1992) Apr 2010Prompt diagnosis of urinary tract infection (UTI) in children is needed to initiate treatment but is difficult to establish without urine testing, and reliance on... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Prompt diagnosis of urinary tract infection (UTI) in children is needed to initiate treatment but is difficult to establish without urine testing, and reliance on culture leads to delay. Urine dipsticks are often used as an alternative to microscopy, although the diagnostic performance of dipsticks at different ages has not been established systematically.
METHOD
Studies comparing urine dipstick testing in infants versus older children and urine dipstick versus microscopy were systematically searched and reviewed. Meta-analysis of available studies was conducted.
RESULTS
Six studies addressed these questions. The results of meta-analysis showed that the performance of urine dipstick testing was significantly less in the younger children when compared with older children (p < 0.01). Positive likelihood ratio (LR) of both nitrite and leucocyte positive 38.54 [95% confidence interval (CI) 22.49-65.31], negative LR for both negative 0.13 (95% CI 0.07-0.25) are reasonably good, and those for young infants are less reliable [positive LR 7.62 (95% CI 0.95-51.85) and negative LR 0.34 (95% CI 0.66-0.15)]. Comparing microscopy and urine dipstick testing, using bacterial colony count on urine culture showed no significant difference between the two methods.
CONCLUSION
Urine dipstick testing is more effective for diagnosis of UTI in children over 2 years than for younger children.
Topics: Adolescent; Age Factors; Child; Child, Preschool; Humans; Infant; Reagent Strips; Urinalysis; Urinary Tract Infections; Young Adult
PubMed: 20055779
DOI: 10.1111/j.1651-2227.2009.01644.x -
The Cochrane Database of Systematic... Jan 2015Urinary dipsticks are sometimes used for screening asymptomatic people, and for case-finding among inpatients or outpatients who do not have genitourinary symptoms.... (Review)
Review
BACKGROUND
Urinary dipsticks are sometimes used for screening asymptomatic people, and for case-finding among inpatients or outpatients who do not have genitourinary symptoms. Abnormalities identified on screening sometimes lead to additional investigations, which may identify serious disease, such as bladder cancer and chronic kidney disease (CKD). Urinary dipstick screening could improve prognoses due to earlier detection, but could also lead to unnecessary and potentially invasive follow-up testing and unnecessary treatment.
OBJECTIVES
We aimed to quantify the benefits and harms of screening with urinary dipsticks in general populations and patients in hospitals.
SEARCH METHODS
We searched the Cochrane Renal Group's Specialised Register to 8 September 2014 through contact with the Trials Search Co-ordinator using search terms relevant to this review.
SELECTION CRITERIA
Randomised controlled trials and other study types that compared urinary dipstick screening with no dipstick screening were eligible for inclusion. We searched for studies that investigated the use of urinary dipsticks for detecting haemoglobin, protein, albumin, albumin-creatinine ratio, leukocytes, nitrite, or glucose, alone or in any combination, and in any setting. We planned to exclude studies conducted in patients with urinary disorders.
DATA COLLECTION AND ANALYSIS
It was planned that two authors would independently extract data from included studies and assess risk of bias using the Cochrane risk of bias tool. However, no studies met our inclusion criteria.
MAIN RESULTS
Literature searches to 8 September 2014 yielded 4298 records, of which 4249 were excluded following title and abstract assessment. There were 49 records (44 studies) eligible for full text assessment; of these 18 studies were not RCTs and 26 studies compared interventions or controls that were not relevant to this review. Thus, no studies were eligible for inclusion.
AUTHORS' CONCLUSIONS
We found no evidence to assess the benefits and harms of screening with urinary dipsticks, which remain unknown.
Topics: Humans; Kidney Diseases; Reagent Kits, Diagnostic
PubMed: 25626128
DOI: 10.1002/14651858.CD010007.pub2 -
British Journal of Community Nursing Jun 2003The National Service Framework (NSF) for Diabetes (Department of Health, 2002) aims to improve care for people with diabetes. Primary care trusts need to demonstrate the... (Comparative Study)
Comparative Study Review
The National Service Framework (NSF) for Diabetes (Department of Health, 2002) aims to improve care for people with diabetes. Primary care trusts need to demonstrate the provision of cost-effective and evidence based care. The National Institute for Clinical Excellence guidelines (NICE, 2002) recommend that microalbuminuria is tested annually in people with diabetes, either by a dipstick method or by a laboratory method. A mini systematic review was undertaken to establish whether a dipstick method of detecting microalbuminuria is as effective as a laboratory method. Four databases were searched and studies comparing dipstick and laboratory methods were included. A hand search was also included. The review was further limited to the Micral test II compared to a reference laboratory standard. Four studies met the inclusion criteria and it was concluded that the Micral test II has a high sensitivity but not very high specificity with lower positive predictive value; it was therefore found to be adequate as a screening tool but not as a diagnostic tool. Therefore the Micral II test is not as effective as a laboratory comparator.
Topics: Albuminuria; Diabetes Complications; Diabetes Mellitus; Humans; Reference Standards; Reproducibility of Results; Sensitivity and Specificity; Urinalysis
PubMed: 12819585
DOI: 10.12968/bjcn.2003.8.6.11548 -
BMC Pediatrics Apr 2005Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of... (Review)
Review
BACKGROUND
Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of renal scarring. Rapid, cost-effective, methods of UTI diagnosis are required as an alternative to culture.
METHODS
We conducted a systematic review to determine the diagnostic accuracy of rapid tests for detecting UTI in children under five years of age.
RESULTS
The evidence supports the use of dipstick positive for both leukocyte esterase and nitrite (pooled LR+ = 28.2, 95% CI: 17.3, 46.0) or microscopy positive for both pyuria and bacteriuria (pooled LR+ = 37.0, 95% CI: 11.0, 125.9) to rule in UTI. Similarly dipstick negative for both LE and nitrite (Pooled LR- = 0.20, 95% CI: 0.16, 0.26) or microscopy negative for both pyuria and bacteriuria (Pooled LR- = 0.11, 95% CI: 0.05, 0.23) can be used to rule out UTI. A test for glucose showed promise in potty-trained children. However, all studies were over 30 years old. Further evaluation of this test may be useful.
CONCLUSION
Dipstick negative for both LE and nitrite or microscopic analysis negative for both pyuria and bacteriuria of a clean voided urine, bag, or nappy/pad specimen may reasonably be used to rule out UTI. These patients can then reasonably be excluded from further investigation, without the need for confirmatory culture. Similarly, combinations of positive tests could be used to rule in UTI, and trigger further investigation.
Topics: Child, Preschool; Humans; Infant; Kidney; Predictive Value of Tests; Reagent Strips; Urinalysis; Urinary Tract Infections; Urine
PubMed: 15811182
DOI: 10.1186/1471-2431-5-4 -
The Cochrane Database of Systematic... May 2017Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge.... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever.
OBJECTIVES
To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas.
SEARCH METHODS
We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies.
SELECTION CRITERIA
We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone).
DATA COLLECTION AND ANALYSIS
Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable.
MAIN RESULTS
Thirty-seven studies met the inclusion criteria and included a total of 5080 participants (range 50 to 1732). Enteric fever prevalence rates in the study populations ranged from 1% to 75% (median prevalence 24%, interquartile range (IQR) 11% to 46%). The included studies evaluated 16 different RDTs, and 16 studies compared two or more different RDTs. Only three studies used the Grade 1 reference standard, and only 11 studies recruited unselected febrile patients. Most included studies were from Asia, with five studies from sub-Saharan Africa. All of the RDTs were designed to detect S.Typhi infection only.Most studies evaluated three RDTs and their variants: TUBEX in 14 studies; Typhidot (Typhidot, Typhidot-M, and TyphiRapid-Tr02) in 22 studies; and the Test-It Typhoid immunochromatographic lateral flow assay, and its earlier prototypes (dipstick, latex agglutination) developed by the Royal Tropical Institute, Amsterdam (KIT) in nine studies. Meta-analyses showed an average sensitivity of 78% (95% confidence interval (CI) 71% to 85%) and specificity of 87% (95% CI 82% to 91%) for TUBEX; and an average sensitivity of 69% (95% CI 59% to 78%) and specificity of 90% (95% CI 78% to 93%) for all Test-It Typhoid and prototype tests (KIT). Across all forms of the Typhidot test, the average sensitivity was 84% (95% CI 73% to 91%) and specificity was 79% (95% CI 70% to 87%). When we based the analysis on the 13 studies of the Typhidot test that either reported indeterminate test results or where the test format means there are no indeterminate results, the average sensitivity was 78% (95% CI 65% to 87%) and specificity was 77% (95% CI 66% to 86%). We did not identify any difference in either sensitivity or specificity between TUBEX, Typhidot, and Test-it Typhoid tests when based on comparison to the 13 Typhidot studies where indeterminate results are either reported or not applicable. If TUBEX and Test-it Typhoid are compared to all Typhidot studies, the sensitivity of Typhidot was higher than Test-it Typhoid (15% (95% CI 2% to 28%), but other comparisons did not show a difference at the 95% level of CIs.In a hypothetical cohort of 1000 patients presenting with fever where 30% (300 patients) have enteric fever, on average Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results will miss the diagnosis in 66 patients with enteric fever, TUBEX will miss 66, and Test-It Typhoid and prototype (KIT) tests will miss 93. In the 700 people without enteric fever, the number of people incorrectly diagnosed with enteric fever would be 161 with Typhidot tests, 91 with TUBEX, and 70 with Test-It Typhoid and prototype (KIT) tests. The CIs around these estimates were wide, with no difference in false positive results shown between tests.The quality of the data for each study was evaluated using a standardized checklist called QUADAS-2. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low.
AUTHORS' CONCLUSIONS
In 37 studies that evaluated the diagnostic accuracy of RDTs for enteric fever, few studies were at a low risk of bias. The three main RDT tests and variants had moderate diagnostic accuracy. There was no evidence of a difference between the average sensitivity and specificity of the three main RDT tests. More robust evaluations of alternative RDTs for enteric fever are needed.
Topics: Adult; Child; False Negative Reactions; False Positive Reactions; Humans; Immunoassay; Paratyphoid Fever; Polymerase Chain Reaction; Reagent Kits, Diagnostic; Reference Standards; Sensitivity and Specificity; Typhoid Fever
PubMed: 28545155
DOI: 10.1002/14651858.CD008892.pub2 -
Pediatrics Nov 1999To review systematically and to summarize the existing literature regarding performance of rapid diagnostic tests for urinary tract infection (UTI) in children. (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To review systematically and to summarize the existing literature regarding performance of rapid diagnostic tests for urinary tract infection (UTI) in children.
DESIGN
Systematic review and meta-analysis.
METHODS
Published articles reporting the performance of urine dipstick tests (leukocyte esterase [LE] and/or nitrite), Gram stain, or microscopic analysis of spun or unspun urine in the diagnosis of UTI in children =12 years of age. Articles were identified through a comprehensive MEDLINE search, and those articles meeting a priori inclusion criteria were selected. Eligibility criteria included the use of urine culture as the reference standard, independent comparison of urine culture with the results of one of the screening tests, definition of positive screening test results provided, only pediatric patients included or evaluable separately, and both gold standard and screening test performed on all patients. For each test, heterogeneity of reported sensitivity and specificity of all studies was determined. The subgroups of studies with similar definitions of UTI and age of study subjects were analyzed separately to account for some of the differences in reported results. When significant unexplained heterogeneity among studies precluded simple combining of results, a summary receiver-operator characteristic curve was fitted for each screening test, from which pooled estimates of true-positive rate (TPR; ie, sensitivity) and false-positive rate (FPR; 1-specificity) were calculated.
PRIMARY RESULTS
A total of 1489 titles were identified by the MEDLINE search; 26 articles met all criteria for inclusion. There was significant heterogeneity among studies for nearly all tests for both TPR and FPR, which was explained only partially by the stringency of the definition of UTI or age of subjects studied. Based on the pooled estimates, the presence of any bacteria on Gram stain on an uncentrifuged urine specimen had the best combination of sensitivity (0.93) and FPR (0.05). Urine dipstick tests performed nearly as well, with a sensitivity of 0.88 for the the presence of either LE or nitrite and an FPR of 0.04 for the presence of both LE and nitrite. Pyuria had lower TPR and higher FPR: for presence of >5 white blood cells/high-power field in a centrifuged urine sample, the TPR was 0.67 and the FPR was 0.21, whereas for >10 white blood cells per mm(3) in uncentrifuged urine, the TPR was 0.77 and the FPR was 0.11.
CONCLUSIONS
Both Gram stain and dipstick analysis for nitrite and LE perform similarly in detecting UTI in children and are superior to microscopic analysis for pyuria.
Topics: Bacteriuria; Child; Child, Preschool; Colony Count, Microbial; Humans; Infant; Pyuria; ROC Curve; Reagent Strips; Sensitivity and Specificity; Urinalysis; Urinary Tract Infections; Urine
PubMed: 10545580
DOI: 10.1542/peds.104.5.e54