Anaesthesia Jun 2016Postoperative sore throat has a reported incidence of up to 62% following general anaesthesia. In adults undergoing tracheal intubation, female sex, younger age,... (Review)
Review
Postoperative sore throat has a reported incidence of up to 62% following general anaesthesia. In adults undergoing tracheal intubation, female sex, younger age, pre-existing lung disease, prolonged duration of anaesthesia and the presence of a blood-stained tracheal tube on extubation are associated with the greatest risk. Tracheal intubation without neuromuscular blockade, use of double-lumen tubes, as well as high tracheal tube cuff pressures may also increase the risk of postoperative sore throat. The expertise of the anaesthetist performing tracheal intubation appears to have no influence on the incidence in adults, although it may in children. In adults, the i-gel(™) supraglottic airway device results in a lower incidence of postoperative sore throat. Cuffed supraglottic airway devices should be inflated sufficiently to obtain an adequate seal and intracuff pressure should be monitored. Children with respiratory tract disease are at increased risk. The use of supraglottic airway devices, oral, rather than nasal, tracheal intubation and cuffed, rather than uncuffed, tracheal tubes have benefit in reducing the incidence of postoperative sore throat in children. Limiting both tracheal tube and supraglottic airway device cuff pressure may also reduce the incidence.
Topics: Airway Management; Anti-Inflammatory Agents, Non-Steroidal; Humans; Intubation, Intratracheal; Laryngeal Masks; Lidocaine; Pharyngitis; Postoperative Complications; Risk Factors
PubMed: 27158989
DOI: 10.1111/anae.13438 -
Anaesthesia Oct 2014We systematically reviewed 31 adult randomised clinical trials of the i-gel(®) vs laryngeal mask airway. The mean (95% CI) leak pressure difference and relative risk... (Comparative Study)
Comparative Study Meta-Analysis Review
We systematically reviewed 31 adult randomised clinical trials of the i-gel(®) vs laryngeal mask airway. The mean (95% CI) leak pressure difference and relative risk (95% CI) of insertion on the first attempt were similar: 0.40 (-1.23 to 2.02) cmH2 O and 0.98 (0.95-1.01), respectively. The mean (95% CI) insertion time and the relative risk (95% CI) of sore throat were less with the i-gel: by 1.46 (0.33-2.60) s, p = 0.01, and 0.59 (0.38-0.90), p = 0.02, respectively. The relative risk of poor fibreoptic view through the i-gel was 0.29 (0.16-0.54), p < 0.0001. All outcomes displayed substantial heterogeneity, I(2) ≥ 75%. Subgroup analyses did not decrease heterogeneity, but suggested that insertion of the i-gel was faster than for first-generation laryngeal mask airways and that the i-gel leak pressure was higher than first generation, but lower than second-generation, laryngeal mask airways. A less frequent sore throat was the main clinical advantage of the i-gel.
Topics: Adult; Humans; Laryngeal Masks; Pharyngitis; Randomized Controlled Trials as Topic
PubMed: 25040063
DOI: 10.1111/anae.12772 -
Anesthesia and Analgesia Sep 2017The complication rate and efficacy of the Cobra Perilaryngeal Airway (CobraPLA) and laryngeal mask airways (LMAs®) have been evaluated in the published literature, but... (Comparative Study)
Comparative Study Meta-Analysis Review
The complication rate and efficacy of the Cobra Perilaryngeal Airway (CobraPLA) and laryngeal mask airways (LMAs®) have been evaluated in the published literature, but the conclusions have been inconsistent. The aim of this systematic review and meta-analysis was thus to assess the performance of the CobraPLA and LMAs under general anesthesia. We searched PubMed, Embase, and the Cochrane Library for randomized controlled trials comparing the CobraPLA with LMAs under general anesthesia. The LMAs used for comparison were the classic LMA (CLMA) and the unique LMA (ULMA). The random effect model was used if heterogeneity was observed, otherwise the fixed effect model was used. Seventeen randomized controlled trials were included; number of studies analyzed for each result are different and were up to 10. The current result suggests that no significant difference between the devices in the insertion success rate at the first attempt. The success rate of first insertion of the CobraPLA was not different from the rates for the CLMA and the ULMA (relative risk: 0.95, 95% confidence interval [CI], 0.91-1.00). CobraPLA insertion was not different from CLMA and ULMA insertion. The CobraPLA provided an oropharyngeal leak pressure higher than that provided by the CLMA (weight mean difference: 3.90, 95% CI, [1.59-6.21] cmH2O) and ULMA (weight mean difference: 6.57, 95% CI, [4.30-8.84] cmH2O). We also found a higher likelihood of blood staining in the airway with the CobraPLA than with the CLMA. In our research, the principal finding of our meta-analysis is that the success rate of first insertion of the CobraPLA was not different from the rate for each of the CLMA and the ULMA, which featured a short learning curve implying its ease of insertion. There was also no significant difference in the incidence of the best view (with a score of 4) obtained with the CobraPLA compared with the other 2 devices. The CobraPLA does seem to be superior to the CLMA and ULMA in providing a higher oropharyngeal leak pressure. The data were insufficient to establish differences in airway adverse events between the groups except for blood staining in the devices, although mucosal trauma occurred more frequently with the Cobra PLA device than with the CLMA and the ULMA.
Topics: Anesthesia, General; Humans; Intubation, Intratracheal; Laryngeal Masks; Randomized Controlled Trials as Topic
PubMed: 28753166
DOI: 10.1213/ANE.0000000000002316 -
Emergencias : Revista de La Sociedad...Various supraglottic devices are currently available for airway management and are used widely in emergency situations because they are easy to position. We undertook a... (Comparative Study)
Comparative Study
Various supraglottic devices are currently available for airway management and are used widely in emergency situations because they are easy to position. We undertook a systematic review of the literature comparing laryngeal tubes and various laryngeal mask airway devices (LMAs) to determine which ones can be used most efficiently in emergencies. Nine databases were searched, as follows: Cochrane Library Plus, MEDLINE, CINAHL (Cumulative Index to Nursing and Allied Health Literature), Dialnet, Global Health, Nursing & Allied Health Database, CUIDEN, the Web of Science, and ScienceDirect. We collected studies published between 2014 and 2019 in Spanish, English, French, and Portuguese that compared laryngeal tubes to LMAs of different types for supraglottic airway management. Eighteen studies were selected for analysis after critical reading. Significant differences were not seen between tubes and LMAs with respect to most variables, but in certain contexts the oropharyngeal seal and speed of insertion were superior with laryngeal tubes; however, when fiberoptic bronchoscopes were then inserted the view of the glottis was poor. The different contexts in which these devices are used and the scarcity of studies comparing laryngeal tubes to LMAs does not allow us to identify clear differences among them with respect to efficiency. However, tubes seem to offer poorer visibility of the glottis according to evaluation with fiberoptic scopes, a factor to bear in mind if tracheal intubation, which is considered the gold standard, might become necessary.
Topics: Airway Management; Emergency Medical Services; Fiber Optic Technology; Glottis; Humans; Intubation, Intratracheal; Laryngeal Masks
PubMed: 31777215
DOI: No ID Found -
Medicine Oct 2022Non-inflatable cuff laryngeal masks are generally composed of thermoplastic material. The thermoplastic nature of the non-inflatable cuff will become soft and match the... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Non-inflatable cuff laryngeal masks are generally composed of thermoplastic material. The thermoplastic nature of the non-inflatable cuff will become soft and match the laryngeal anatomy better as it reaches body temperature after intubation. This meta-analysis aims to evaluate the clinical validity of prewarming non-inflatable cuff laryngeal mask before insertion.
METHODS
We searched PubMed, Cochrane Library, Embase, Web of Science, Ovid Medline, CNKI, Wan Fang Database and VIP Database to find randomized controlled trials (RCTs) researching the clinical validity of prewarming non-inflatable cuff laryngeal mask. The retrieval time is up to June 2022. Articles published in the English and Chinese languages were considered. Quality assessment was conducted with the Cochrane Collaboration's tool and GRADE (Grading of Recommendations Assessment, Development and Evaluation) method. Subgroup analyses and trial sequential analysis (TSA) were performed to control the risk of random errors. Publication bias was assessed by funnel plots and Egger's regression test. The outcomes included sealing pressure immediately after successful ventilation, the first-attempt intubation success rate and the incidence of postoperative pharyngeal pain.
RESULTS
Eight RCTs evaluating 683 patients were identified. Pooled results showed that compared to the control group, prewarming non-inflatable cuff laryngeal mask provided a higher sealing pressure immediately after successful ventilation (mean difference: 1.73 cm H2O; 95% confidence interval [CI]: 0.95-2.52; P < .0001; I2 = 16; high quality), higher first-attempt intubation success rate (risk ratio [RR]: 1.05; 95% CI: 1.01-1.09; P = .01; I2 = 26%; high quality, number needed to treat [NNT] = 22 [95% CI 12.5-100]) and lower incidence of postoperative pharyngeal pain (RR: 0.59, 95% CI: 0.46-0.75; P < .0001; I2 = 0; high quality, NNT = 6 [95% CI 4.17-9.09]). The results were confirmed by TSA.
CONCLUSION
Prewarming non-inflatable cuff laryngeal mask could provide better mechanical ventilation efficiency with higher sealing pressure, a higher first-attempt intubation success rate and a lower incidence of postoperative pharyngeal pain.
TRIAL REGISTRATION NUMBER
PROSPERO CRD42021245350.
Topics: Humans; Laryngeal Masks; Pain; Respiration, Artificial
PubMed: 36316864
DOI: 10.1097/MD.0000000000031032 -
PloS One 2016Flexible laryngeal mask airways (FLMAs) have been widely used in thyroidectomy as well as cleft palate, nasal, upper chest, head and neck oncoplastic surgeries. This... (Comparative Study)
Comparative Study Meta-Analysis Review
Airway Complications during and after General Anesthesia: A Comparison, Systematic Review and Meta-Analysis of Using Flexible Laryngeal Mask Airways and Endotracheal Tubes.
OBJECTIVE
Flexible laryngeal mask airways (FLMAs) have been widely used in thyroidectomy as well as cleft palate, nasal, upper chest, head and neck oncoplastic surgeries. This systematic review aims to compare the incidence of airway complications that occur during and after general anesthesia when using the FLMA and endotracheal intubation (ETT). We performed a quantitative meta-analysis of the results of randomized trials.
METHODS
A comprehensive search of the PubMed, Embase and Cochrane Library databases was conducted using the key words "flexible laryngeal mask airway" and "endotracheal intubation". Only prospective randomized controlled trials (RCTs) that compared the FLMA and ETT were included. The relative risks (RRs) and the corresponding 95% confidence intervals (95% CIs) were calculated using a quality effects model in MetaXL 1.3 software to analyze the outcome data.
RESULTS
Ten RCTs were included in this meta-analysis. There were no significant differences between the FLMA and ETT groups in the incidence of difficulty in positioning the airway [RR = 1.75, 95% CI = (0.70-4.40)]; the occurrence of sore throat at one hour and 24 hours postoperative [RR = 0.90, 95% CI = (0.13-6.18) and RR = 0.95, 95% CI = (0.81-1.13), respectively]; laryngospasms [RR = 0.58, 95% CI = (0.27-1.23)]; airway displacement [RR = 2.88, 95% CI = (0.58-14.33)]; aspiration [RR = 0.76, 95% CI = (0.06-8.88)]; or laryngotracheal soiling [RR = 0.34, 95% CI = (0.10-1.06)]. Patients treated with the FLMA had a lower incidence of hoarseness [RR = 0.31, 95% CI = (0.15-0.62)]; coughing [RR = 0.28, 95% CI = (0.15-0.51)] during recovery in the postanesthesia care unit (PACU); and oxygen desaturation [RR = 0.43, 95% CI = (0.26-0.72)] than did patients treated with ETT. However, the incidence of partial upper airway obstruction in FLMA patients was significantly greater than it was for ETT patients [RR = 4.01, 95% CI = (1.44-11.18)].
CONCLUSION
This systematic review showed that the FLMA has some advantages over ETT because it results in a lower incidence of hoarseness, coughing and oxygen desaturation. There were no statistically significant differences in the difficulty of intubation or in the occurrence of laryngospasms, postoperative sore throat, airway displacement, aspiration or laryngotracheal soiling. However, there was a higher incidence of partial upper airway obstruction in the FLMA than in the ETT group. We conclude that the FLMA has some advantages over ETT, but surgeons and anesthesiologists should be cautious when applying the mouth gag, moving the head and neck, or performing oropharyngeal procedures to avoid partial upper airway obstruction and airway displacement. The FLMA should not be used on patients at high risk for aspiration.
Topics: Anesthesia, General; Cough; Hoarseness; Humans; Incidence; Intubation, Intratracheal; Laryngeal Masks; Pharyngitis; Postoperative Complications
PubMed: 27414807
DOI: 10.1371/journal.pone.0158137 -
BMJ Open Aug 2017To evaluate the optimal dose of succinylcholine for laryngeal mask airway (LMA) insertion and all related morbidities. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
To evaluate the optimal dose of succinylcholine for laryngeal mask airway (LMA) insertion and all related morbidities.
DESIGN
Systematic review, meta-analysis and metaregression of randomised controlled trials (RCTs).
DATA SOURCE AND STUDY ELIGIBILITY CRITERIA
A comprehensive search of RCTs in the PubMed, Embase, the Cochrane Library and the ClinicalTrials.gov registry up to July 2016 and articles that evaluated the use of succinylcholine chloride for LMA insertion were included in the analyses. The relative risk (RR) and the corresponding 95% CIs were determined.
INTERVENTION
Succinylcholine as the coinduction agent and the doses were divided into mini (≤0.3 mg/kg) and low (0.3-1.0 mg/kg) doses for dose-dependent effect analyses.
PRIMARY AND SECONDARY OUTCOMES
The primary outcome was the first-attempt LMA insertion failure rate. Secondary outcomes included all related adverse events.
RESULTS
Data from 10 RCTs comprising 625 participants showed that succinylcholine reduced the first-attempt LMA insertion failure rate (RR, 0.22; 95% CI 0.12 to 0.43), coughing and gagging (RR, 0.26; 95% CI 0.15 to 0.45) and laryngospasm (RR, 0.14; 95% CI 0.05 to 0.39). The use of succinylcholine did not result in a significant increase of postoperative myalgia (RR, 2.58; 95% CI 0.79 to 8.44) and did not reduce the risk of postoperative sore throat (RR, 0.76; 95% CI 0.55 to 1.03). Subgroup analysis further showed that low-dose succinylcholine reduced the LMA insertion failure rate and its related coughing and gagging when compared with mini dose.
CONCLUSION
The use of succinylcholine compared with none can facilitate LMA insertion and reduce insertion-related reflexes without significant postoperative myalgia. However, additional prospective studies with a larger sample size are required to fully evaluate the dose-dependent effect and complications of succinylcholine for LMA insertion.
Topics: Cough; Dose-Response Relationship, Drug; Gagging; Humans; Intubation, Intratracheal; Laryngeal Masks; Neuromuscular Depolarizing Agents; Pain, Postoperative; Pharyngitis; Randomized Controlled Trials as Topic; Succinylcholine; Treatment Outcome
PubMed: 28780538
DOI: 10.1136/bmjopen-2016-014274 -
Pediatric Pulmonology Jan 2022Less invasive surfactant administration methods without laryngoscopy and endotracheal catheterization include delivery via laryngeal mask airway, pharyngeal... (Review)
Review
Less invasive surfactant administration methods without laryngoscopy and endotracheal catheterization include delivery via laryngeal mask airway, pharyngeal instillation, and aerosolization. These less invasive techniques are promising and have several advantages over INSURE (Intubation-Surfactant-Extubation) and thin catheter techniques. The objective of this review is to discuss the requisites, techniques, short-term outcomes, and adverse events associated with these methods.
Topics: Humans; Infant, Newborn; Infant, Premature; Intubation, Intratracheal; Laryngeal Masks; Pulmonary Surfactants; Respiratory Distress Syndrome, Newborn; Surface-Active Agents
PubMed: 34559459
DOI: 10.1002/ppul.25698 -
Anaesthesia Sep 2014Previous comparisons between the Ambu(®) AuraOnce(™) and other laryngeal mask airways have revealed different results across various clinical studies. We aimed to... (Comparative Study)
Comparative Study Meta-Analysis Review
Previous comparisons between the Ambu(®) AuraOnce(™) and other laryngeal mask airways have revealed different results across various clinical studies. We aimed to perform a systematic review with meta-analysis on the efficacy and safety of the AuraOnce compared with other laryngeal mask airways for airway maintenance in adults undergoing general anaesthesia. Our search of PubMed, PubMed Central, Scopus and the Central Register of Clinical Trials of the Cochrane Collaboration yielded nine randomised controlled trials eligible for inclusion. Comparator laryngeal mask airways were the LMA Unique(™) (four trials), the LMA Classic(®) (five trials) and the Portex(®) Soft Seal(®) (three trials). The AuraOnce provided an oropharyngeal leak pressure higher than the LMA Unique (304 participants, mean (95% CI) difference 3.1 (1.6-4.7) cmH2 O, p < 0.0001) and equivalent to the LMA Classic. The Soft Seal provided a higher leak pressure than the AuraOnce (229 participants, mean (95% CI) difference 3.5 (0.4-6.7) cmH2 O, p = 0.03). Insertion was significantly faster with the AuraOnce than the LMA Unique (304 participants, mean (95% CI) difference 5.4 (2.1-8.71) s, p = 0.001) and Soft Seal (229 participants, mean (95% CI) difference 9.5 (3.0-15.9) s, p = 0.004), but similar to the LMA Classic. The first-insertion success rate of the AuraOnce was equivalent to the LMA Unique, LMA Classic and Soft Seal. We found a higher likelihood of bloodstaining on the cuff with the Soft Seal and a higher incidence of sore throat with the LMA Classic. We conclude that the AuraOnce is an effective alternative to the LMA Classic and LMA Unique, and easier to insert than all three other devices studied.
Topics: Adolescent; Adult; Aged; Air Pressure; Anesthesia, General; Female; Humans; Laryngeal Masks; Larynx; Male; Middle Aged; Odds Ratio; Patient Safety; Pharyngitis; Postoperative Complications; Prospective Studies; Randomized Controlled Trials as Topic; Treatment Outcome; Young Adult
PubMed: 24801012
DOI: 10.1111/anae.12682 -
Anaesthesia May 2015We performed a systematic review to compare the efficacy and safety of the streamlined liner of the pharynx airway and laryngeal mask airway used in adults during... (Comparative Study)
Comparative Study Meta-Analysis Review
We performed a systematic review to compare the efficacy and safety of the streamlined liner of the pharynx airway and laryngeal mask airway used in adults during general anaesthesia. We included 14 studies with studies with 1273 patients in total. There was no evidence of a difference between the two devices in insertion success rate on the first attempt (13 studies, 1143 patients), insertion time (seven studies, 576 patients), ease of insertion (five studies, 466 patients), oropharyngeal leak pressure (eight studies, 771 patients) and the quality of the fibreoptic view of the larynx through the device (three studies, 281 patients). The relative risk (95% CI) of bloodstaining of the device (nine studies, 859 patients) was 2.09 (1.46-3.00) for the streamlined liner of the pharynx airway compared with the laryngeal mask airway. Other adverse events were comparable. Subgroup analysis suggested that the insertion by novice users might be faster and more successful with the streamlined liner of the pharynx airway than the laryngeal mask airway; however, this was from only two studies and 186 patients. The method of size selection of the streamlined liner of the pharynx airway device might also affect the speed of insertion: choosing according to the width of the patient's thyroid cartilage, rather than height, may produce better results.
Topics: Airway Management; Clinical Competence; Equipment Design; Humans; Intubation, Intratracheal; Laryngeal Masks; Pharynx
PubMed: 25693455
DOI: 10.1111/anae.13035