American Journal of Otolaryngology 2022Cochlear implant (CI) migration due to head trauma is a rare complication, and there is limited data summarizing this topic. This review seeks to provide a more... (Review)
Review
OBJECTIVE
Cochlear implant (CI) migration due to head trauma is a rare complication, and there is limited data summarizing this topic. This review seeks to provide a more comprehensive understanding of risk factors, clinical presentations, diagnosis, and intervention strategies for traumatic CI displacement.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Protocol was followed using the PubMed and MED-LINE databases from 2000 to 2021, with manual cross-checks of reference lists of identified articles for additional relevant studies. The keywords used for database searches included "cochlear implant", "migration", "displacement", "extrusion" and "head trauma". All full-text articles available in English were screened, including single case presentations. Abstracts, commentaries, and publications deemed outside the scope of our study aims were excluded from review.
RESULTS
After the removal of duplicate articles, a total of 152 articles were screened. After applying inclusion and exclusion criteria, 11 articles were included in the review. Due to heterogeneity of the available literature, a qualitative synthesis was employed to integrate results by identifying common themes among the relevant studies.
CONCLUSIONS
The incidence of traumatic CI migration is extremely low and can be due to receiver-stimulator displacement, magnet displacement, or electrode extrusion. Migration occurred anywhere from 3 months to 26 years after implantation, suggesting that risk of migration from head trauma does not depend solely on time from implantation. There are several methods for repairing migrated CI, but there is limited data comparing operative techniques, specifically in the prevention of traumatic CI migration.
Topics: Cochlear Implantation; Cochlear Implants; Craniocerebral Trauma; Humans
PubMed: 35988364
DOI: 10.1016/j.amjoto.2022.103553 -
Journal of Neurosurgery. Pediatrics Sep 2022Several growth-preserving surgical techniques are employed in the management of early-onset scoliosis (EOS). The authors' objective was to compare the use of traditional... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
Several growth-preserving surgical techniques are employed in the management of early-onset scoliosis (EOS). The authors' objective was to compare the use of traditional growing rods (TGRs), magnetically controlled growing rods (MCGRs), Shilla growth guidance techniques, and vertically expanding prosthetic titanium ribs (VEPTRs) for the management of EOS.
METHODS
A systematic review of electronic databases, including Ovid MEDLINE and Cochrane, was performed. Outcomes of interest included correction of Cobb angle, T1-S1 distance, and complication rate, including alignment, hardware failure and infection, and planned and unplanned reoperation rates. The percent changes and 95% CIs were pooled across studies using random-effects meta-analysis.
RESULTS
A total of 67 studies were identified, which included 2021 patients. Of these, 1169 (57.8%) patients underwent operations with TGR, 178 (8.8%) Shilla growth guidance system, 448 (22.2%) MCGR, and 226 (11.1%) VEPTR system. The mean ± SD age of the cohort was 6.9 ± 1.2 years. The authors found that the Shilla technique provided the most significant improvement in coronal Cobb angle immediately after surgery (mean [95% CI] 64.3% [61.4%-67.2%]), whereas VEPTR (27.6% [22.7%-33.6%]) performed significantly worse. VEPTR also performed significantly worse than the other techniques at final follow-up. The techniques also provided comparable gains in T1-S1 height immediately postoperatively (mean [95% CI] 10.7% [8.4%-13.0%]); however, TGR performed better at final follow-up (21.4% [18.7%-24.1%]). Complications were not significantly different among the patients who underwent the Shilla, TGR, MCGR, and VEPTR techniques, except for the rate of infections. The TGR technique had the lowest rate of unplanned reoperations (mean [95% CI] 15% [10%-23%] vs 24% [19%-29%]) but the highest number of planned reoperations per patient (5.31 [4.83-5.82]). The overall certainty was also low, with a high risk of bias across studies.
CONCLUSIONS
This analysis suggested that the Shilla technique was associated with a greater early coronal Cobb angle correction, whereas use of VEPTR was associated with a lower correction rate at any time point. TGR offered the most significant height gain at final follow-up. The complication rates were comparable across all surgical techniques. The optimal surgical approach should be tailored to individual patients, taking into consideration the strengths and limitations of each option.
Topics: Humans; Child, Preschool; Child; Scoliosis; Prostheses and Implants; Reoperation; Titanium; Ribs; Retrospective Studies; Treatment Outcome; Follow-Up Studies
PubMed: 36152334
DOI: 10.3171/2022.8.PEDS22156 -
Pharmaceutics Jul 2023The incidence of gastrointestinal cancers has increased in recent years. Current treatments present numerous challenges, including drug resistance, non-specificity, and... (Review)
Review
The incidence of gastrointestinal cancers has increased in recent years. Current treatments present numerous challenges, including drug resistance, non-specificity, and severe side effects, needing the exploration of new therapeutic strategies. One promising avenue is the use of magnetic nanoparticles, which have gained considerable interest due to their ability to generate heat in tumor regions upon the application of an external alternating magnetic field, a process known as hyperthermia. This review conducted a systematic search of in vitro and in vivo studies published in the last decade that employ hyperthermia therapy mediated by magnetic nanoparticles for treating gastrointestinal cancers. After applying various inclusion and exclusion criteria (studies in the last 10 years where hyperthermia using alternative magnetic field is applied), a total of 40 articles were analyzed. The results revealed that iron oxide is the preferred material for magnetism generation in the nanoparticles, and colorectal cancer is the most studied gastrointestinal cancer. Interestingly, novel therapies employing nanoparticles loaded with chemotherapeutic drugs in combination with magnetic hyperthermia demonstrated an excellent antitumor effect. In conclusion, hyperthermia treatments mediated by magnetic nanoparticles appear to be an effective approach for the treatment of gastrointestinal cancers, offering advantages over traditional therapies.
PubMed: 37514144
DOI: 10.3390/pharmaceutics15071958 -
BMJ Clinical Evidence Mar 2007Dysmenorrhoea may begin soon after the menarche, after which it often improves with age, or it may originate later in life after the onset of an underlying causative... (Review)
Review
INTRODUCTION
Dysmenorrhoea may begin soon after the menarche, after which it often improves with age, or it may originate later in life after the onset of an underlying causative condition. Dysmenorrhoea is common, and in up to 20% of women it may be severe enough to interfere with daily activities.
METHODS AND OUTCOMES
We conducted a systematic review and aimed to answer the following clinical question: What are the effects of treatments for dysmenorrhoea? We searched: Medline, Embase, The Cochrane Library and other important databases up to July 2006 (Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA).
RESULTS
We found 34 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions.
CONCLUSIONS
In this systematic review we present information relating to the effectiveness and safety of the following interventions: acupressure, acupuncture, aspirin, behavioural interventions, combined oral contraceptives, compound analgesics, fish oil, herbal remedies, magnesium, magnets, non-steroidal anti-inflammatory drugs, paracetamol, spinal manipulation, surgical interruption of pelvic nerve pathways, thiamine, toki-shakuyaku-san, topical heat, transcutaneous electrical nerve stimulation (TENS), vitamin B12, and vitamin E.
Topics: Dysmenorrhea; Humans
PubMed: 19454059
DOI: No ID Found -
BMJ Clinical Evidence Aug 2007Up to 18% of people in industrialised societies have mild tinnitus, which severely affects daily life in 0.5% of people. Tinnitus can be associated with hearing loss,... (Review)
Review
INTRODUCTION
Up to 18% of people in industrialised societies have mild tinnitus, which severely affects daily life in 0.5% of people. Tinnitus can be associated with hearing loss, acoustic neuromas, drug toxicity, ear diseases, and depression. Tinnitus can last for many years, and can interfere with sleep and concentration.
METHODS AND OUTCOMES
We conducted a systematic review and aimed to answer the following clinical question: What are the effects of treatments for chronic tinnitus? We searched: Medline, Embase, The Cochrane Library and other important databases up to December 2006. (BMJ Clinical evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA).
RESULTS
We found 37 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions.
CONCLUSIONS
In this systematic review we present information relating to the effectiveness and safety of the following interventions: acamprosate, acupuncture, antidepressant drugs, baclofen, benzodiazepines, carbamazepine, cinnarizine, ear-canal magnets, electromagnetic stimulation, ginkgo biloba, hearing aids, hyperbaric oxygen, hypnosis, lamotrigine, nicotinamide, psychotherapy, tinnitus-masking devices, tinnitus retraining therapy, zinc.
Topics: Tinnitus; United States
PubMed: 19454115
DOI: No ID Found -
Diagnostics (Basel, Switzerland) Jul 2022Appendicular soft tissue lymphoma (ASTL) is rare and is frequently misinterpreted as soft tissue sarcoma (STS). Studies investigating magnet resonance imaging (MRI)... (Review)
Review
Appendicular soft tissue lymphoma (ASTL) is rare and is frequently misinterpreted as soft tissue sarcoma (STS). Studies investigating magnet resonance imaging (MRI) characteristics of ASTL are scarce and showed heterogenous investigation criteria and results. The purpose of this study was to systematically review clinical presentations and MRI characteristics of ASTL as described in the current literature. For that purpose, we performed a systematic literature review in compliance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Patient demographics, clinical presentation and MRI imaging characteristics of ASTL were investigated, resulting in a total of nine included studies reporting a total of 77 patients. Signal intensity of lymphoma compared to muscle tissue was mostly described as isointense (53%) or slightly hyperintense (39%) in T1-weighted images and always as hyperintense in proton-and T2-weighted images. Multicompartmental involvement was reported in 59% of cases and subcutaneous stranding in 74%. Long segmental involvement was present in 80% of investigated cases. Involvement of neurovascular structures was reported in 41% of cases and the presence of traversing vessels in 83% of patients. The presence of these findings should lead to the inclusion of ASTL in the differential diagnosis of soft tissue masses.
PubMed: 35885528
DOI: 10.3390/diagnostics12071623 -
Alternative Therapies in Health and... Nov 2023Leukemia is the most prevalent cancer among children and adolescents. This study investigated the potential association between exposure to magnetic fields and the risk... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Leukemia is the most prevalent cancer among children and adolescents. This study investigated the potential association between exposure to magnetic fields and the risk of pediatric leukemia.
METHODS
We conducted a comprehensive search of electronic databases, including Scopus, EMBASE, Cochrane, Web of Science, and Medline, up to December 15, 2022, to identify relevant studies examining the link between childhood leukemia and magnetic field exposure.
RESULTS
The first meta-analysis revealed a statistically significant inverse association between pediatric leukemia and magnetic field strengths ranging from 0.4 μT to 0.2 μT, suggesting a reduced risk associated with this range. The second meta-analysis focused on wiring configuration codes and observed a potential link between residential magnetic field exposure and childhood leukemia. Pooled relative risk estimates were 1.52 (95% CI = 1.05-2.04, P = .021) and 1.58 (95% CI = 1.15-2.23, P = .006) for exposure to 24-hour magnetic field measurements, suggesting a possible causal relationship. In the third meta-analysis, the odds ratios for the exposure groups of 0.1 to 0.2 μT, 0.2 to 0.3 μT, 0.3 to 0.4 μT, and 0.4 μT above 0.2 μT were 1.09 (95% confidence interval = 0.82 to 1.43 μT), 1.14 (95% confidence interval = 0.68 to 1.92 μT), and 1.45 (95% confidence interval = 0.87 to 2.37 μT), respectively. In contrast to the findings of the three meta-analyses, there was no evidence of a statistically significant connection between exposure to 0.2 μT and the risk of juvenile leukemia. A further result showed no discernible difference between the two groups of children who lived less than 100 meters from the source of magnetic fields and those who lived closer (OR = 1.33; 95% CI = 0.98-1.73 μT).
CONCLUSIONS
The collective results of three meta-analyses, encompassing magnetic field strengths ranging from 0.1 μT to 2.38 μT, underscore a statistically significant association between the intensity of magnetic fields and the occurrence of childhood leukemia. However, one specific analysis concluded that no apparent relationship exists between exposure to 0.1 μT and an elevated risk of leukemia development in children.
Topics: Adolescent; Child; Humans; Electromagnetic Fields; Leukemia; Magnetic Fields; Neoplasms; Electromagnetic Radiation; Environmental Exposure; Case-Control Studies
PubMed: 37678874
DOI: No ID Found -
BMC Oral Health Jul 2022Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also...
BACKGROUND
Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also for the radiologist. Essentially, the MRI-safe scan of the fixed orthodontic tools requires a proper guideline in clinical practice. Therefore, this systematic review aimed to examine all aspects of MRI-safe scan, including artifact, thermal, and debonding effects, to identify any existing gaps in knowledge in this regard and develop an evidence-based protocol.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement was used in this study. The clinical question in "PIO" format was: "Does MRI examination influence the temperature of the orthodontic devices, the size of artifacts, and the debonding force in patients who have fixed orthodontic bracket and/or wire?" The search process was carried out in PubMed, PubMed Central, Scopus, and Google Scholar databases. The search resulted in 1310 articles. After selection according to the eligibility criteria, 18 studies were analyzed by two reviewers. The risk of bias was determined using the Quality In Prognosis Studies tool.
RESULTS
Out of the eligible 18 studies, 10 articles examined the heating effect, 6 were about the debonding effect, and 11 measured the size of artifact regarding brackets and wires. Considering the quality assessment, the overall levels of evidence were high and medium. The published studies showed that heating and debonding effects during MRI exposure were not hazardous for patients. As some wires revealed higher temperature changes, it is suggested to remove the wire or insert a spacer between the appliances and the oral mucosa. Based on the material, ceramic and plastic brackets caused no relevant artifact and were MRI-safe. Stainless steel brackets and wires resulted in susceptibility artifacts in the orofacial region and could cause distortion in the frontal lobe, orbits, and pituitary gland. The retainer wires showed no relevant artifact.
CONCLUSIONS
In conclusion, the thermal and debonding effects of the fixed orthodontic brackets and wires were irrelevant or resoluble; however, the size of the artifacts was clinically relevant and determined most significantly the feasibility of fixed brackets and wires in MRI examination.
Topics: Artifacts; Humans; Magnetic Resonance Imaging; Orthodontic Brackets; Orthodontic Wires; Stainless Steel
PubMed: 35854295
DOI: 10.1186/s12903-022-02317-9 -
JBI Database of Systematic Reviews and... Jul 2015The Magnet model proposes an accreditation for hospitals having demonstrated a healthy work environment and, as a result, positive staff and patient outcomes. Yet there... (Review)
Review
BACKGROUND
The Magnet model proposes an accreditation for hospitals having demonstrated a healthy work environment and, as a result, positive staff and patient outcomes. Yet there are conflicting findings surrounding the actual impact of Magnet's organizational model on these outcomes, as well as a wide range of designs influencing the quality of these results.
OBJECTIVES
To conduct a systematic review that explores the effect of Magnet accreditation on objective nurse and patient outcomes.
TYPES OF PARTICIPANTS
Magnet and non-Magnet accredited hospitals matched according to their similarity (e.g. size, type [urban or rural], level of acuity, location, etc.). Hospitals could be either university based or non-teaching hospitals and in any geographical location. As the focus of the study was outcomes specific to Magnet accreditation, studies reporting on "reputational Magnets" (the original hospitals), Magnet-aspiring and non-Magnet hospitals alone were excluded from the review. TYPES OF INTERVENTION(S)/PHENOMENA OF INTEREST: Exposure to Magnet accreditation. A Magnet hospital is defined as a hospital with American Nursing Credentialing Center -designated Magnet status at the time of study and having received this accreditation in the last four years, as this is the length of time for which the accreditation is valid, after which the hospital must reapply for another four-year accreditation. TYPES OF STUDIES: This review considered any quantitative study comparing nurse and patient outcomes in Magnet accredited hospitals with those in non-Magnet hospitals. Controlled clinical trials, controlled before and after and interrupted time series were considered first. When these were not available, case-controlled, descriptive comparative and descriptive correlational designs were considered. All studies presenting a "case study" with no comparison and other studies reporting on interviews and other qualitative data were excluded. TYPES OF OUTCOMES: The outcomes of interest were nurse outcomes related to turnover and absenteeism, as measured by the actual turnover rate if available, or the Anticipated Turnover Scale, the Revised Nursing Work Index or the Maslach Burnout Inventory, as well as nursing-sensitive patient outcomes (such as fall rates and hospital-acquired pressure ulcers) as measured by retrospective patient records, discharge abstracts, incident reports and reimbursement forms.
SEARCH STRATEGY
Both published and unpublished literature between 1994 and 2014 were searched. The electronic databases searched were the following: CINAHL, MEDLINE, EMBASE, Academic Search Complete and Web of Science. Other resources included ProQuest Dissertations & Theses Database /Dissertation Abstracts Online and OpenGrey, the American Hospital Association and the American Nurses Credentialing Center websites, and the Sigma Theta Tau International library of abstracts. In April 2015, a search update was conducted including the years 2014-2015 in the databases listed above.
METHODOLOGICAL QUALITY
No cut-off point for the Joanna Briggs Institute appraisal tool criteria was selected for inclusion of studies.
DATA EXTRACTION
Data from included studies were extracted using the Joanna Briggs Institute Data Extraction Form for experimental/observational studies. Two reviewers extracted the data independently and results were compared for accuracy and categorized according to nurse and patient outcomes.
DATA SYNTHESIS
All the studies analyzed retrospective data obtained from either combined databases or from questionnaires. The methodological heterogeneity and poor quality of the designs did not make it possible to pool quantitative results in a statistical meta-analysis. Results are presented in descriptive narrative form.
RESULTS
From the 141 screened studies, ten met the inclusion criteria. Nine of these studies were retrospective analyses of data extracted from existing databases, one study collected original data. Of the seven studies examining patient outcomes, three found clear statistically significant improvements related to lower pressure ulcers, patient falls, failure to rescue and 30-day inpatient mortality in Magnet hospitals compared to non-Magnet hospitals. In the studies examining nurse outcomes, three found statistically significant improvements related to higher job satisfaction and lower intent to leave and turnover rates in Magnet compared to non-Magnet hospitals.
CONCLUSIONS
Based on the mixed results and poor quality in the research designs in the ten included studies, it was not possible to conclude that Magnet accreditation has effects on nurse and patient outcomes. There is a need for more robust designs that can confidently measure the impact of hospital accreditation on objective outcomes.
Topics: Accreditation; Hospitals; Humans; Job Satisfaction; Models, Organizational; Nursing Staff, Hospital; Outcome Assessment, Health Care; Personnel Turnover; United States
PubMed: 26455752
DOI: 10.11124/jbisrir-2015-2262 -
Electric/Magnetic Intervention for Bone Regeneration: A Systematic Review and Network Meta-Analysis.Tissue Engineering. Part B, Reviews Jun 2023Electric/magnetic material or field is a promising strategy for bone regeneration. The aim of this systematic review and network meta-analysis was to analyze the... (Meta-Analysis)
Meta-Analysis Review
Electric/magnetic material or field is a promising strategy for bone regeneration. The aim of this systematic review and network meta-analysis was to analyze the evidence regarding the efficacy of electric and magnetic intervention for bone regeneration and provide directions for further research. A comprehensive search was performed to identify the rats/rabbits/mice research that involved the electric/magnetic treatment with quantitative radiographic assessment of bone formation. Network meta-analyses were also conducted to assess different interventions and outcomes for osteogenesis. In total, there were 51 articles included in the systematic review and 19 articles in the network meta-analyses. The majority used microcomputerized tomography bone volume/tissue volume (BV/TV) to evaluate outcomes in rats. Results showed that placing electric/magnetic materials had more prominent effects than the electric/magnetic field on bone regeneration. For all species, electrical materials with zeta potential of -53 mV proved to be the most effective in increasing BV (mean difference [MD]: 4.20 mm, 95% confidence interval [CI]: [1.72-6.68]) and bone mineral density (MD: 312 mg/cm, 95% CI: [172.43-451.57]). Magnetic materials with external magnetic fields topped in BV/TV (MD: 43%, 95% CI: [36.04-49.96]). It also led in trabecular number (MD: 2.00 mm, 95% CI: [1.45-2.55]), trabecular thickness (MD: 61.00 μm, 95% CI: [44.31- 77.69]), and trabecular separation (MD: -0.40 mm, 95% CI: [-0.56 to -0.24]) on the condition of lacking electric materials. Biomaterials implantation is the most effective method for stimulating osteogenesis in rats, especially in electrical materials with negative charge. The combination of diverse interventions shows promising effects but needs further research, so does the underlying mechanism. Impact Statement Bone defect, especially for the large defect from aging, trauma, or pathology, which cannot be completely healed, remains a clinical challenge. Mimicking physical microenvironment has emerged as a new strategy for tissue regeneration. Electric and magnetic material and field used as the physical stimulation for bone regeneration have attracted interest due to their potential and facile application in clinic. This article reviewed related animal studies and carried out a network meta-analysis to thoroughly understand how electric and magnetic interventions impacted on tissues and created an osteogenic microenvironment.
Topics: Rats; Mice; Rabbits; Animals; Network Meta-Analysis; Bone Regeneration; Osteogenesis; Bone and Bones; Magnetic Phenomena
PubMed: 36170583
DOI: 10.1089/ten.TEB.2022.0127