Head & Face Medicine Jul 2021Orthodontic retention aims to maintain optimal teeth positions after active treatment. The stability is affected by numerous factors, including patients' individual... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Orthodontic retention aims to maintain optimal teeth positions after active treatment. The stability is affected by numerous factors, including patients' individual features, thus retention should be adjusted in the most optimal way. Bonding a retainer makes retention less dependent on patient's compliance.
QUESTIONS ARISE
What wire or fiber splint type provides the best treatment stability? What materials should be used to bond the wire or fiber splint? Should be the bonding procedure be direct or indirect? The aim of the study is to assess and synthesize available controlled trials investigating failures of fixed retainers.
METHODS
Literature searches of free text and MeSH terms were performed in Scopus, Web of Science, Embase and PubMed Central in order to find studies, referring to failures of fixed retention (12th February 2021). The keywords were: ("orthodontic retainers AND failure AND wire"). The framework of this systematic review according to PICO was: Population: orthodontic patients; Intervention: fixed orthodontic retainer bonding; Comparison: Different protocols of fixed orthodontic retention applied; Outcomes: failure rate, survival rate. Three different specific scales from the Cochrane Collaboration Handbook were used, according to each study type. Additionally, a meta-analysis was conducted to compare the effectiveness of retention using fiber reinforced composite and multistranded steel wire.
RESULTS
The search identified 177 potential articles: 114 from PubMed, 41 from Scopus, 20 from Web of Science and 2 from Embase. After excluding studies inconsistent with selection criteria, 21 studies were included and subjected to qualitative analysis. The main outcome investigated was failure rate. This systematic review has some potential limitations due to the heterogeneity of design between included studies.
CONCLUSIONS
No retainer is proved to guarantee a perfect stability of dental alignment. The retainer should be bonded to all adherent teeth, preferably with additional use of bonding resin. No wire or fiber splint present superior characteristics concerning failure rate. Fiber reinforced composite retention is more sensitive to operator skills, and with imperfect bonding technique, failure rate is much higher. During the first 6 months after bonding retainer the patient should be under frequent control. The study protocol was registered in PROSPERO database with the number CRD42021233406.
Topics: Dental Bonding; Humans; Orthodontic Appliance Design; Orthodontic Retainers; Orthodontic Wires
PubMed: 34301280
DOI: 10.1186/s13005-021-00281-3 -
BMC Oral Health Jul 2022Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also...
BACKGROUND
Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also for the radiologist. Essentially, the MRI-safe scan of the fixed orthodontic tools requires a proper guideline in clinical practice. Therefore, this systematic review aimed to examine all aspects of MRI-safe scan, including artifact, thermal, and debonding effects, to identify any existing gaps in knowledge in this regard and develop an evidence-based protocol.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement was used in this study. The clinical question in "PIO" format was: "Does MRI examination influence the temperature of the orthodontic devices, the size of artifacts, and the debonding force in patients who have fixed orthodontic bracket and/or wire?" The search process was carried out in PubMed, PubMed Central, Scopus, and Google Scholar databases. The search resulted in 1310 articles. After selection according to the eligibility criteria, 18 studies were analyzed by two reviewers. The risk of bias was determined using the Quality In Prognosis Studies tool.
RESULTS
Out of the eligible 18 studies, 10 articles examined the heating effect, 6 were about the debonding effect, and 11 measured the size of artifact regarding brackets and wires. Considering the quality assessment, the overall levels of evidence were high and medium. The published studies showed that heating and debonding effects during MRI exposure were not hazardous for patients. As some wires revealed higher temperature changes, it is suggested to remove the wire or insert a spacer between the appliances and the oral mucosa. Based on the material, ceramic and plastic brackets caused no relevant artifact and were MRI-safe. Stainless steel brackets and wires resulted in susceptibility artifacts in the orofacial region and could cause distortion in the frontal lobe, orbits, and pituitary gland. The retainer wires showed no relevant artifact.
CONCLUSIONS
In conclusion, the thermal and debonding effects of the fixed orthodontic brackets and wires were irrelevant or resoluble; however, the size of the artifacts was clinically relevant and determined most significantly the feasibility of fixed brackets and wires in MRI examination.
Topics: Artifacts; Humans; Magnetic Resonance Imaging; Orthodontic Brackets; Orthodontic Wires; Stainless Steel
PubMed: 35854295
DOI: 10.1186/s12903-022-02317-9 -
Journal of Orthodontic Science 2023A variety of metals and alloys are employed in the field of orthodontics, primary of which happen to be the construction of wires. Through this systematic review, we... (Review)
Review
A variety of metals and alloys are employed in the field of orthodontics, primary of which happen to be the construction of wires. Through this systematic review, we aimed to assess the various metallurgical characteristics of the said metals and alloys. Four hundred and eighty-two documents in total were found after a thorough search of the online journals, and 169 of the papers were initially chosen. Ultimately, 16 documents were selected that satisfied the necessary inclusion and exclusion criteria, primarily studies, literature reviews, and comparative analyses. NiTi alloy was found to be the most commonly used alloy in construction of orthodontic wires across all the studies that we had selected for our review. It also had better performance and consistency in terms of its usage as depicted by the meta-analysis performed, with stainless steel wires being a close second primarily due to its lesser cost compared to the former. Metallurgy and orthodontics are inextricably linked with one another. The various components of orthodontics such as wires, pliers, and other instruments utilize the metallurgical characteristics of metals and alloys that are specially prepared for the challenges of this field. CRD42022378444.
PubMed: 37881657
DOI: 10.4103/jos.jos_52_23 -
Journal of Orthodontic Science 2023Infection control is essential to protect both the doctor and the patient by preventing the spread of infectious diseases. There is no exception in the field of... (Review)
Review
Infection control is essential to protect both the doctor and the patient by preventing the spread of infectious diseases. There is no exception in the field of dentistry, particularly in orthodontics, where numerous appliances are used for a variety of functions and also because the mouth cavity has the highest concentration of bacteria of any body part. Through this systematic review, we aimed to assess the various methods of sterilization employed in an orthodontic setting. Using relevant keywords, reference searches, and citation searches, the databases such as PubMed, MEDLINE, Web of Science, Cochrane, and Scopus were all searched; a total of 206 documents were found, of which 113 were initially selected. The remaining 23 distinct papers were initially made available after 90 publications that were identical to or similar to one another were eliminated. The final selection was made from eight documents that met all inclusion and exclusion requirements. The existing methods of sterilization were found to be competent in dealing with the microorganisms found in a typical orthodontic setting. The chemical method of sterilization was the norm in most of the studies that we assessed, with glutaraldehyde and peracetic acid (PAA) being the most commonly employed compounds for disinfection. CRD42022380831.
PubMed: 37881658
DOI: 10.4103/jos.jos_53_23 -
European Journal of Orthodontics Mar 2022The aim of this systematic review was to compare the different force delivery systems for orthodontic space closure by sliding mechanics. (Meta-Analysis)
Meta-Analysis
BACKGROUND/OBJECTIVES
The aim of this systematic review was to compare the different force delivery systems for orthodontic space closure by sliding mechanics.
SEARCH METHODS
Multiple sources including Cochrane Central, Ovid Medline, Embase etc. were used to identify all relevant studies.
SELECTION CRITERIA
Randomized controlled trials (RCT) of parallel-group and split-mouth designs were included.
PARTICIPANTS
Orthodontic patients of any age treated with fixed orthodontic appliances and requiring space closure.
DATA COLLECTION AND ANALYSIS
Search result screening, data extraction and quality assessment were performed independently and in duplicate by 2 reviewers. The included studies were grouped into parallel-arm and split-mouth studies and subgroup analysis was then performed for the type of retraction subsets; en-masse and individual canine retraction. A traditional meta-analysis, and network meta-analysis (NMA) for direct and indirect comparisons for the rate of space closure were performed.
RESULTS
Thirteen studies, six parallel-arm and seven split-mouth were included. The traditional meta-analysis comparing Nickel-titanium (NiTi) closed coil springs and elastomeric power chain for the rate of tooth movement showed statistically significant difference favouring NiTi springs (MD: 0.24; 95% CI, 0.03-0.45; I2 0%, P = 0.02) and the comparison between NiTi springs and active ligatures also showed statistically significant result favouring NiTi springs (MD: 0.53; 95% CI, 0.44-0.63; I2 0%, P ˂ 0.00001) for the rate of tooth movement. NMA for the rate of space closure showed fairly confident evidence for NiTi coil springs when compared with elastomeric chain and active ligatures. The NiTi coil spring ranked best between all methods of space closure.
CONCLUSIONS
There is moderate quality evidence in favour of NiTi coil springs for the rate of space closure when compared with active ligature and low quality of evidence favouring NiTi springs when compared with elastomeric chain. The ranking from NMA showed NiTi coil springs to be the best method for space closure with 99% chance. An urgent need for standardization of study designs and the need for development of an agreed core outcome sets and core outcome instrument measurement sets is evident.
REGISTRATION
PROSPERO CRD42020157811.
Topics: Dental Alloys; Elasticity; Humans; Orthodontic Space Closure; Orthodontic Wires; Titanium; Tooth Movement Techniques
PubMed: 34609513
DOI: 10.1093/ejo/cjab047 -
Journal of Orthodontic Science 2022This systematic review was aimed to test the null hypothesis that coating of orthodontic wires with nanoparticles does not affect the frictional properties at... (Review)
Review
This systematic review was aimed to test the null hypothesis that coating of orthodontic wires with nanoparticles does not affect the frictional properties at bracket--wire interface. Electronic database searches were performed up to September 2020. studies were considered for reviewing process. Study selection, data extraction, risk of bias assessment was performed during reviewing process. Only qualitative analyses of included literature were done due to the presence of heterogeneity among the studies. Out of 1,068 retrieved records, nine studies satisfied the inclusion criteria and included in this review. Studies were assessed at low risk to high risk of bias according to certain parameters. Wide variety of nanoparticles were used for surface coating of orthodontic wires of variable sizes, shapes, and materials like stainless steel, NiTi, and TMA and placed into the slots of different types of orthodontic brackets to evaluate the alteration in frictional and other mechanical properties. Most of the studies clearly indicate that coating with nanoparticles decreases the friction between wire and bracket interface under specified conditions. Furthermore, among the nine included studies, only two considered evaluation of effect of coated brackets on frictional and other mechanical properties and results were heterogeneous. The null hypothesis is rejected and it is concluded that the wires coated with nanoparticles might offer a novel opportunity to substantially reduce frictional resistance at bracket--wire interface during tooth movement. Further studies are necessary to strengthen the evidence regarding effect of coated brackets on frictional properties.
PubMed: 35754415
DOI: 10.4103/jos.jos_152_21 -
Dental Press Journal of Orthodontics 2023With the advent of COVID-19, teledentistry and remote monitoring have become an imminent reality that allows orthodontists to monitor orthodontic treatment through... (Meta-Analysis)
Meta-Analysis
INTRODUCTION
With the advent of COVID-19, teledentistry and remote monitoring have become an imminent reality that allows orthodontists to monitor orthodontic treatment through virtual checkups, which complement in-office appointments.
OBJECTIVE
To evaluate the effectiveness of using teledentistry in monitoring the evolution of orthodontic treatment.
MATERIAL AND METHODS
Searches were performed in on-line databases. PECO strategy focused on comparing orthodontic patients exposed and not exposed to teledentistry. Searches and data extraction followed PRISMA guidelines. The assessment of the risk of bias and the certainty of the evidence was performed using the ROBINS-I and GRADE tools, respectively. A meta-analysis was also performed.
RESULTS
Out of 1,178 records found, 4 met the criteria and were included in the qualitative analysis. The risk of bias for follow-up assesment in aligner treatment was low to moderate; while for interceptive treatment, it was high. Studies are favorable to the use of teledentistry. The meta-analysis was performed with aligners studies only, due to heterogeneity. The certainty of the evidence was considered very low.
CONCLUSION
With very low certainty of evidence, teledentistry using Dental Monitoring® software is effective as an aid in monitoring the evolution of interceptive orthodontic treatment (high risk of bias) and, especially, treatment performed with aligners (low to moderate risk of bias). The meta-analysis evidenced a reduction in the number of face-to-face appointments (mean difference = -2.75[-3.95, -1.55]; I2=41%; p<0.00001) and the time for starting refinement (mean difference = -1.21[-2.35, -0.08]; I2=49%; p=0.04). Additional randomized studies evaluating corrective orthodontic treatment with brackets and wires are welcome.
Topics: Humans; COVID-19; Databases, Factual; Orthodontics, Corrective; Orthodontists; Software
PubMed: 37729285
DOI: 10.1590/2177-6709.28.4.e2322195.oar -
Cureus May 2022The objective of the current review was to evaluate the effectiveness of traditional and accelerated methods of palatally impacted canine's (PIC) traction in terms of... (Review)
Review
The Effectiveness of Conventional and Accelerated Methods of Orthodontic Traction and Alignment of Palatally Impacted Canines in Terms of Treatment Time, Velocity of Tooth Movement, Periodontal, and Patient-Reported Outcomes: A Systematic Review.
The objective of the current review was to evaluate the effectiveness of traditional and accelerated methods of palatally impacted canine's (PIC) traction in terms of treatment duration, velocity, periodontal, and patient-reported variables. An electronic search for randomized controlled trials (RCTs) and controlled clinical trials (CCTs) published between January 1990 and October 2021 was conducted in nine databases. Five major orthodontic journals were hand searched for additional studies. The participants were patients with unilateral or bilateral PICs who received conventional or accelerated orthodontic treatment with fixed appliances. Cochrane's risk of bias tool (RoB 2 tool) for RCTs and ROBINS-I tool for CCTs were used to assess the risk of bias. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) guidelines were used to assess the overall quality of the evidence. Nine articles (eight RCTs and one CCT) were included in this review (371 patients). There was no clarity in most studies about the possible effect of the mechanical traction method on treatment outcomes. The treatment duration decreased (about three to six months) when the open surgical method was used with traditional techniques and the traction velocity increased significantly (about 1-1.5 mm/month) when acceleration methods were used. No significant differences were found between the conventional intervention groups, as well as between the traditional and accelerated groups, in terms of most periodontal variables (p > 0.005). No significant differences were found in the pain levels associated with traditional PICs' traction when comparing different exposure methods in the short-term follow-up (1-10 days), while contradictory results were found in the pain incidence between these methods. The relationship between the pain/discomfort levels and the type of mechanical traction method was not evaluated. According to the GRADE, the quality of evidence supporting these findings ranged from low to very low. The combination of the open surgical technique with various designs of either superelastic wires or elastic traction means can lead to a reduction in the orthodontic treatment duration of PICs. The use of direct anchorage by miniscrews to move the PICs away from the adjacent teeth roots can lead to a reduction in root resorption and shorten the treatment duration. The evidence supporting these findings ranged from low to very low. The use of different types of mechanical means for conventional PICs' traction, with the use of open or closed traction techniques, does not lead to significant differences in periodontal outcomes between intervention groups. Contradictory results exist regarding the severity of the perceived pain in relation to the surgical exposure type, and the relationship between this variable and the mechanical traction method is still unclear. The use of accelerated methods for PICs' traction can lead to an increase in the velocity of traction movement with no significant differences in periodontal outcomes between accelerated and conventional methods. The evidence supporting these findings ranged from low to very low. More high-quality randomized CCTs are needed to establish good evidence in this field. The protocol of this systematic review was registered in the International Prospective Register of Systematic Reviews (PROSPERO; CRD42021274476) during the first stages of this review.
PubMed: 35572459
DOI: 10.7759/cureus.24888 -
Orthodontics & Craniofacial Research Feb 2018The aim of this study is to explore the effectiveness of nickel titanium closing springs (NiTi-CS) and elastomeric power chains (EPC) in orthodontic space closure and to... (Meta-Analysis)
Meta-Analysis Review
UNLABELLED
The aim of this study is to explore the effectiveness of nickel titanium closing springs (NiTi-CS) and elastomeric power chains (EPC) in orthodontic space closure and to assess the adverse periodontal effects, cost efficiency and patient-centred outcomes between both of these methods.
METHODS
An electronic search of online databases (Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Scopus, LILACS and Web of Science), reference lists and grey literature as well as hand search were conducted without language restriction up to November/2017. Two authors blindly and in duplicate were involved in study selection, quality assessment and the extraction of data. Only randomized clinical trials (RCTs) were included. The quality of the studies was assessed using the Cochrane Collaboration's risk of bias tool. 95% confidence intervals and mean difference for continuous data were calculated. A meta-analysis that generated a random-effect model for the comparable outcomes was conducted, and heterogeneity was measured using I statistic.
RESULTS
Of 187 records, 4 RCTs met the criteria and were included in the quantitative synthesis featuring 290 test quadrants. Faster space closure with NiTi-CS was observed with a mean difference of (0.20 mm/month, 95% CI: 0.12 to 0.28). Loss of anchorage appears to be similar within both groups when synthesized qualitatively. With exception to anchorage loss, secondary outcomes could not be investigated in the included trials.
CONCLUSIONS
There is a moderate quality of evidence suggesting a faster orthodontic space closure with the NiTi-CS when compared to EPC. A comparable amount of anchorage loss was observed regardless of the utilized method of space closure. Further high-quality RCTs with parallel-groups, reporting on the adverse effects and patient-centred values, are recommended.
Topics: Elastomers; Humans; Nickel; Orthodontic Space Closure; Orthodontic Wires; Polymers; Stress, Mechanical; Titanium
PubMed: 29265578
DOI: 10.1111/ocr.12210