-
Marine Pollution Bulletin Dec 2023The persistent plastic litter, originating from different sources and transported from rivers to oceans, has posed serious biological, ecological, and chemical effects... (Meta-Analysis)
Meta-Analysis Review
The persistent plastic litter, originating from different sources and transported from rivers to oceans, has posed serious biological, ecological, and chemical effects on the marine ecosystem, and is considered a global issue. In the past decade, many studies have identified, monitored, and tracked marine plastic debris in coastal and open ocean areas using remote sensing technologies. Compared to traditional surveying methods, high-resolution (spatial and temporal) multispectral or hyperspectral remote sensing data have been substantially used to monitor floating marine macro litter (FMML). In this systematic review, we present an overview of remote sensing data and techniques for detecting FMML, as well as their challenges and opportunities. We reviewed the studies based on different sensors and platforms, spatial and spectral resolution, ground sampling data, plastic detection methods, and accuracy obtained in detecting marine litter. In addition, this study elaborates the usefulness of high-resolution remote sensing data in Visible (VIS), Near-infrared (NIR), and Short-Wave InfraRed (SWIR) range, along with spectral signatures of plastic, in-situ samples, and spectral indices for automatic detection of FMML. Moreover, the Thermal Infrared (TIR), Synthetic aperture radar (SAR), and Light Detection and Ranging (LiDAR) data were introduced and these were demonstrated that could be used as a supplement dataset for the identification and quantification of FMML.
Topics: Ecosystem; Remote Sensing Technology; Environmental Monitoring; Plastics; Oceans and Seas; Waste Products
PubMed: 37951122
DOI: 10.1016/j.marpolbul.2023.115746 -
European Journal of Surgical Oncology :... Sep 2016Preoperative biliary drainage (PBD) with stenting increases complications compared with surgery without PBD. Metallic stents are considered superior to plastic stents... (Comparative Study)
Comparative Study Meta-Analysis Review
BACKGROUND
Preoperative biliary drainage (PBD) with stenting increases complications compared with surgery without PBD. Metallic stents are considered superior to plastic stents when considering stent-related complications. Aim of the present systematic review and meta-analysis is to compare the rate of endoscopic re-intervention before surgery and postoperative outcomes of metal versus plastic stents in patients with resectable periampullary or pancreatic head neoplasms.
METHODS
We conducted a bibliographic research using the National Library of Medicine's PubMed database, including both randomized controlled trials (RCTs) and non-RCTs. Quantitative synthesis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Statistical heterogeneity was assessed using the I(2) tests.
RESULTS
One RCT and four non-RCTs were selected, including 704 patients. Of these, 202 patients (29.5%) were treated with metal stents and 502 (70.5%) with plastic stents. The majority of patients (86.4%) had pancreatic cancer. The rate of endoscopic re-intervention after preoperative biliary drainage was significantly lower in the metal stent (3.4%) than in the plastic stent (14.8%) group (p < 0.0001). The rate of postoperative pancreatic fistula was significantly lower in the meta stent group as well (5.1% versus 11.8%, p = 0.04). The rate of post-operative surgical complications and of - post-operative mortality did not differ between the two groups.
CONCLUSIONS
Although the present systematic review and meta-analysis demonstrates that metal stent are more effective than plastic stents for PBD in patients with resectable periampullary tumors, randomized controlled trials are needed in order to confirm these data with a higher level of evidence.
Topics: Ampulla of Vater; Biliary Tract Surgical Procedures; Drainage; Humans; Jaundice, Obstructive; Metals; Pancreatectomy; Pancreatic Neoplasms; Plastics; Postoperative Complications; Preoperative Care; Risk Factors; Stents
PubMed: 27296728
DOI: 10.1016/j.ejso.2016.05.001 -
The Journal of Evidence-based Dental... Dec 2023The aim of this systematic review was to evaluate the survival and complication rates of resin composite laminate veneers. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
The aim of this systematic review was to evaluate the survival and complication rates of resin composite laminate veneers.
METHODS
Randomized controlled trials and cohort studies with a minimum 2-year follow-up assessing survival and complication rates of resin composite laminate veneers on permanent dentition from 1998 to May 2022. Literature searches were conducted in MEDLINE (PubMed), Scopus, and the Cochrane Central Register of Controlled Trials electronic databases. References cited in the related reviews and included full-text articles were also hand-searched to further identify potentially relevant studies.
RESULTS
A total of 827 articles were identified. Twenty-two studies were considered for full-text review after the title and abstract screening stage. After exclusion, 7 studies (3 randomized controlled trials and 4 cohort studies) were included in the systematic review. Three published scales were adopted for the quality and risk of bias assessment. At the survival rate threshold, the overall heterogeneity (I) for randomized controlled trials was 50.5% (P = .108). The overall pooled survival rate of the randomized controlled trials was 88% (95% CI: 81%-94%), with the mean follow-up time ranging from 24 to 97 months. Surface roughness, color mismatch, and marginal discoloration were the most reported complications.
CONCLUSION
Resin composite laminate veneers demonstrated moderately high survival rates for the entire sample and the direct laminate veneer group demonstrated higher survival rates than the indirect approach. Most of the complications were regarded as clinically acceptable with or without reintervention.
Topics: Humans; Dental Porcelain; Composite Resins; Dental Restoration Failure
PubMed: 38035903
DOI: 10.1016/j.jebdp.2023.101911 -
Annals of Medicine Dec 2023Patients with walled-off necrosis (WON) are still challenging to treat safely and effectively. Recently, double-pigtail plastic stents (DPS), bi-flanged metallic stents... (Meta-Analysis)
Meta-Analysis
Safety and efficacy of lumen-apposing metal stents and double-pigtail plastic stents for endoscopic ultrasound-guided drainage of walled-off necrosis; a systematic review and meta-analysis.
BACKGROUND
Patients with walled-off necrosis (WON) are still challenging to treat safely and effectively. Recently, double-pigtail plastic stents (DPS), bi-flanged metallic stents (BFMS), and lumen-apposing metal stents (LAMS) have been employed with endoscopic ultrasound-guided (EUS-guided) drainage. However, there is little solid evidence to support the effectiveness and safety of using stents. This study aims to compare the outcomes of the LAMS and the PS.
METHOD
Till July 2022, a thorough database search was done, and studies that met the criteria were chosen. By using the RevMan software, the technical and clinical success and other secondary outcomes were calculated. Subgroup analysis was performed between the LAMS and the BFMS.
RESULTS
Fifteen studies (two randomized controlled trials and thirteen observational) with 687 patients receiving metal stents and 771 patients receiving plastic stents were selected for final analysis. There was no significant risk of bias or publication bias. The odds ratios (OR) for technical and clinical success were 0.36 (95% confidence interval (95% CI) 0.08, 1.52) and 2.26 (95%CI 1.62, 3.15), respectively. The OR for overall adverse events was 0.74 (95% CI 0.41, 1.34). In subgroup analysis, the LAMS and the BFMS showed the same outcomes.
CONCLUSION
Compared to DPS, LAMS had better clinical outcomes and fewer side effects when treating patients with WON.
Topics: Humans; Plastics; Treatment Outcome; Stents; Drainage; Necrosis; Ultrasonography, Interventional; Retrospective Studies
PubMed: 36779694
DOI: 10.1080/07853890.2022.2164048 -
Journal of Prosthodontics : Official... Jun 2022To systematically review past studies to determine the effect of various solutions on the color of denture teeth, thus answering the question in regards to which type of... (Review)
Review
PURPOSE
To systematically review past studies to determine the effect of various solutions on the color of denture teeth, thus answering the question in regards to which type of denture teeth has the best optical properties after exposure to various solutions. The method of measuring the color of artificial teeth was also evaluated as a secondary outcome.
MATERIALS AND METHODS
A search of studies that quantitatively investigated the influence of immersion solutions on the color change of denture teeth was conducted. Ovid MEDLINE, PubMed and Scopus databases were searched from 1997 to April 2021. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used during article selection. Data regarding the effect of immersion solutions, accelerated aging and surface treatments on color change were gathered. Methodologies used to assess optical properties were also summarized and compared. The modified CONSORT checklist was used to determine the risk of bias of past studied included in this review.
RESULTS
One hundred thirty-three studies were identified after removing duplicates. Forty-one studies were selected for full-text analysis, and 35 remaining papers met the inclusion criteria and were therefore included in this systematic review. Thirty-two in vitro studies and 3 in vivo studies were included in the review. All studies reported that immersion in various solutions has a significant influence on the change in color and optical properties of denture teeth. However, the discoloration of denture teeth is still clinically acceptable in most studies. Exposure to various solutions also affected the translucency parameter of denture teeth. Most studies also investigated the surface roughness and hardness along with the optical properties, and reported that immersion cycles did not cause changes in surface roughness of denture teeth, while hardness was affected. The optical properties of PMMA denture teeth have been studied extensively, whereas that of CAD/CAM and 3D printed denture teeth is limited.
CONCLUSIONS
Color stability of CAD/CAM milled denture teeth is comparable to conventional PMMA denture teeth. There are contradictory findings in terms of color stability of 3D printed denture teeth as compared to conventional PMMA denture teeth. Staining by coffee is worst among the common beverages and solutions investigated. Denture teeth can show color changes after immersion in staining beverages as early as one week. The degree of discoloration of denture teeth after immersion is time dependent, with the larger extent in the initial phase.
Topics: Acrylic Resins; Color; Materials Testing; Polymethyl Methacrylate; Surface Properties
PubMed: 34516027
DOI: 10.1111/jopr.13429 -
Dental Materials : Official Publication... May 2022The present review is an update of a systematic review that has been published in 2012. Meanwhile, many new clinical trials on resin composites had been published. New... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
The present review is an update of a systematic review that has been published in 2012. Meanwhile, many new clinical trials on resin composites had been published. New materials such as bulk fill resin composites and new glass-ionomer (GIC) based materials had been introduced. The focus of this review was to evaluate the longevity in relation to the material class and adhesive class, while adjusting for a possible study bias effect.
MATERIAL AND METHODS
The database PUBMED/SCOPUS were searched for clinical trials on posterior resin composites. The inclusion criteria were: (1) studies published between 2000 and 2019, (2) prospective clinical trial with at least 2 years of observation; (2) minimal number of restorations at last recall = 20; (3) report on drop-out rate; (4) report of operative technique and used materials; (5) utilisation of Ryge, modified Ryge or FDI evaluation criteria. The bias of each study was assessed by two independent reviewers using Cochrane Collaboration's tool for assessing risk of bias in randomised trials. For the statistical analysis, linear mixed models fitted on the individual data recorded along time have been used with random effects to account for study, patients and experiment effects. P-values smaller than 0.05 were considered significant.
RESULTS
Of the 423 clinical trials, 62 studies (including 110 experiments) met the inclusion criteria. Material class was divided according to the composite filler in microhybrid (39 experiments/2807 restorations), nanohybrid (24 experiments/1254 restorations), and hybrid (22 experiments/1255 restorations). So-called bulk fill materials were treated as a separate category (9 experiments/506 restorations) as were the GIC (11 experiments/2121 restorations) and the compomer materials (5 experiments/238 restorations). Only one study (1.6%) had low risk of bias, 42 (67.7%) were assessed to have unclear risk of bias and 19 (30.6%) had a high risk of bias. In 52.3% of the studies Class II and Class I restorations had been placed. After 10 years, the survival rate for resin composite restorations dropped to about 85-90% with no significant difference between hybrid, microhybrid and nao-hybrid resin materials. The main reasons for restoration replacement were bulk fractures and wear, which accounted for a about 70% of replacements. Caries at the restorative margins accounted for about 20% of the replacements, and retention loss, inacceptable colour match or marginal integrity, endodontic treatment or cusp fracture for about 10% of the replacements of the resin composite restorations. For compomer and GIC restorations the mean overall survival rate was about 80% after 6 years. For GIC, the main reasons for failure were substantial loss of anatomical contour along with loss of proximal contacts and retention loss. Mainly fractures reduced the longevity of compomers restorations. Also, there was no statistically significant difference between hybrid, micro-hybrid, nano-hybrid and bulk fill resin composites with regard to colour match, surface texture, material fractures, and anatomical form.
CONCLUSIONS
Posterior resin composite restorations that were placed with the enamel etch technique showed the best overall performance; the longevity was not significantly influenced by the filler type or viscosity of resin composite material. With regard to colour match, surface texture and anatomical form, nanohybrid resins were not significantly superior to hybrid or microhybrid resin composites. Compomer and GIC restorations demonstrated considerable shortcomings and had a significant shorter longevity.
Topics: Compomers; Composite Resins; Dental Caries; Dental Restoration, Permanent; Glass Ionomer Cements; Humans; Prospective Studies; Treatment Outcome
PubMed: 35221127
DOI: 10.1016/j.dental.2021.10.018 -
Clinical Nephrology Jun 2017The relationship between the sieving coefficient (SC) or extraction ratio (ER) and the molecular weight (MW) of peptide and protein solutes during hemofiltration has not... (Review)
Review
The relationship between the sieving coefficient (SC) or extraction ratio (ER) and the molecular weight (MW) of peptide and protein solutes during hemofiltration has not been investigated; it is possible that the SC and ER correlate with MW, permitting an estimate of peptide and protein clearance by hemofiltration in the absence of empiric data. A search for studies of the SC and/or ER for peptide and protein solutes during hemofiltration identified data for β-microglobulin, brain natriuretic peptide, carperitide, IL-1β, IL-1RA, IL-6, IL-8, lysozyme, myoglobin, neutrophil gelatinase-associated lipocalin, procalcitonin, retinol-binding protein, TNF-α, soluble TNFR-1, soluble TNFR-II, and vasopressin using polyacrylonitrile, polysulfone, polyamide, and cellulose hemofilters. The SC correlated with MW using polyacrylonitrile, polyamide, and cellulose hemofilters. With fewer data, the ER did not correlate with MW using polyacrylonitrile hemofilters, and not enough data were available to assess the ER with any other hemofilters. These results may help predict peptide and protein convective clearance during hemofiltration with polyacrylonitrile, polyamide, and cellulose hemofilters when empiric data are not available. .
Topics: Acrylic Resins; Blood Proteins; Hemofiltration; Humans
PubMed: 28211786
DOI: 10.5414/CN108841 -
The Science of the Total Environment Oct 2022Plastic litter is a pollutant of aquatic environments worldwide, with some of the world's highest litter densities occurring in freshwater ecosystems. Little information... (Review)
Review
Plastic litter is a pollutant of aquatic environments worldwide, with some of the world's highest litter densities occurring in freshwater ecosystems. Little information about the risk that plastic litter poses to aquatic wildlife is available across the world's most polluted waterways. To help assess the risk to aquatic species where empirical data is lacking, our review presents i) a risk assessment methodology for predicting plastic litter impacts on aquatic wildlife in data poor environments, ii) a case study demonstrating this risk assessment methodology for wildlife across two heavily polluted river basins in Asia, the Mekong and Ganges River Basins; and iii) a broad review summarising common trends in litter interactions and risk to freshwater fish, aquatic birds, cetaceans and raptors. This risk analysis unites a systematic review approach with risk matrices following International Standards Organization's risk assessment criteria, evaluating the risk of plastic entanglement and ingestion and the potential for harm to the animal. In the Mekong and Ganges River Basins, we found that the risk of litter entanglement is higher than litter ingestion. Four species were forecast to be at high risk of entanglement: Ganges River dolphin, Gharial, Mekong giant catfish and Irrawaddy dolphin. The eastern imperial eagle and greater spotted eagle were noted to be at moderate risk of entanglement. Both the Ganges River dolphin and Irrawaddy dolphin were predicted to have a moderate risk of plastic ingestion. Interestingly, cranes, waterfowl and wading birds were deemed at low or negligible risk from plastic litter. This risk matrix methodology can be applied to other waterways and taxa to assess the risk posed by plastic. It can also be readily updated as more information becomes available. This review enables decision makers to bridge a data gap by providing a tool for conservation and management before comprehensive empirical data is available.
Topics: Animals; Animals, Wild; Birds; Dolphins; Ecosystem; Plastics; Rivers
PubMed: 35772547
DOI: 10.1016/j.scitotenv.2022.156858 -
Digestive Endoscopy : Official Journal... May 2015Metal stents are being used more frequently for transmural endoscopic drainage of pancreatic fluid collections (PFC) despite lack of data. The present systematic review... (Review)
Review
BACKGROUND AND AIM
Metal stents are being used more frequently for transmural endoscopic drainage of pancreatic fluid collections (PFC) despite lack of data. The present systematic review was conducted to compare the rates of treatment success, adverse events and recurrence between patients undergoing metal versus plastic stent placement for endoscopic transmural drainage of PFC.
METHODS
MEDLINE and EMBASE were searched to identify all published manuscripts that evaluated metal stents for endoscopic transmural drainage of PFC. All published studies from the same period involving plastic stent placement for PFC drainage that included >50 patients were also identified. Main outcome measures were to compare the rates of treatment success, adverse events and recurrence between the metal and plastic stent cohorts.
RESULTS
Seventeen studies (881 patients) met inclusion criteria. There was no difference in overall treatment success between patients treated with plastic and metal stents (81% [95% CI, 77-84%] vs 82% [95% CI, 74-88%]) for both pseudocysts (85% [95% CI, 81-89%] vs 83% [95% CI, 74-89%]) and walled-off necrosis (70% [95% CI, 62-76%] vs 78% [95% CI, 50-93%]). Also, there was no difference in the rates of adverse events (16% [95% CI, 14-39%] vs 23% [95% CI, 16-33%]) or recurrence (10% [95% CI, 8-13%] vs 9% [95% CI, 4-19%]) between plastic and metal stents.
CONCLUSIONS
Current evidence does not support routine placement of metal stents for transmural drainage of PFC. Randomized trials are needed to justify the use of metal stents for PFC drainage.
Topics: Drainage; Endoscopy, Digestive System; Equipment Design; Humans; Pancreatic Juice; Pancreatic Pseudocyst; Plastics; Self Expandable Metallic Stents; Treatment Outcome
PubMed: 25515976
DOI: 10.1111/den.12418 -
Frontiers in Public Health 2023Micro/nano-plastics (MNPs) are considered a heterogeneous class of environmental contaminants that cause multiple toxic effects on biological species. As the commonly... (Meta-Analysis)
Meta-Analysis
Micro/nano-plastics (MNPs) are considered a heterogeneous class of environmental contaminants that cause multiple toxic effects on biological species. As the commonly used mammalian models to study the effects of MNPs with regard to their toxic effects, the mouse and rat models are making a great contribution to the disciplines of environmental toxicology and medical health. However, the toxic effects of MNPs have not been systematically summarized. Therefore, a systematic review and a meta-analysis of the toxic effects of MNPs on mouse/rat models were conducted. A total of seven main categories were established in this systematic review, and 24 subcategories were further divided according to the specific physiological significance of the endpoint or the classification of the physiological system, which covered all the selected pieces of literature. A total of 1,762 biological endpoints were found, and 52.78% of them were significantly affected. This fact indicates that there are relative factors, including the size, polymer type, concentration, and exposure time of MNPs and different sexes of mouse/rat models that could significantly affect the biological endpoints. These biological endpoints can be classified into various factors, such as the dose-response relationships between MNP concentration and physiological categories of the nervous system, growth, reproduction, digestive tract histopathology, and inflammatory cytokine level, among others. MNPs negatively affected the blood glucose metabolism, lipid metabolism, and reproductive function in mice. The reproductive function in male mice is more sensitive to the toxic effects of MNPs. These findings also provide insights into and directions for exploring the evidence and mechanisms of the toxic effects of MNPs on human health. It is clear that more research is required on the pathological mechanisms at the molecular level and the long-term effects of tissue accumulation.
Topics: Rats; Mice; Male; Humans; Animals; Plastics; Microplastics; Mammals
PubMed: 37275491
DOI: 10.3389/fpubh.2023.1103289