International Dental Journal Jun 2022The aim of this review was to evaluate the most used suture materials with regards to their inflammatory response, their bacterial adhesion, and their physical... (Review)
Review
BACKGROUND
The aim of this review was to evaluate the most used suture materials with regards to their inflammatory response, their bacterial adhesion, and their physical properties when used to close oral wounds.
METHODS
Four databases (PubMed, Scopus, Dentistry & Oral Sciences, and OVID) were searched to retrieve relevant studies from January 1, 2000, to January 31, 2020.
RESULTS
Out of the 269 articles, only 13 studies were selected as they were relevant and met the systematic review's protocol. These studies showed that almost all suture materials studies (catgut, polyglycolic acid [PGA] sutures, nylon, expanded polytetrafluoroethylene, and silk sutures) caused bacterial adherence and tissue reaction. In nylon and chromic catgut, the number of bacteria accumulated was lowest. Silk and nylon were found to be more impacted than catgut and PGA in terms of physical characteristics such as tensile strength. PGA, on the other hand, was said to be the most susceptible to knot unwinding.
CONCLUSIONS
Following an oral surgical operation, all sutures revealed varied degrees of irritation and microbial accumulation. Nonresorbable monofilament synthetic sutures, however, exhibited less tissue response and less microbial accumulation.
Topics: Humans; Nylons; Oral Surgical Procedures; Polyglycolic Acid; Sutures
PubMed: 35305815
DOI: 10.1016/j.identj.2022.02.005 -
The Science of the Total Environment Feb 2024Microplastics are plastic particles, films, and fibers with a diameter of < 5 mm. Given their long-standing existence in the environment and terrible increase in annual... (Review)
Review
Microplastics are plastic particles, films, and fibers with a diameter of < 5 mm. Given their long-standing existence in the environment and terrible increase in annual emissions, concerns were raised about the potential health risk of microplastics on human beings. In particular, the increased consumption of masks during the COVID-19 pandemic has dramatically increased human contact with microplastics. To date, the emergence of microplastics in the human body, such as feces, blood, placenta, lower airway, and lungs, has been reported. Related toxicological investigations of microplastics were gradually increased. To comprehensively illuminate the interplay of microplastic exposure and human health, we systematically reviewed the updated toxicological data of microplastics and summarized their mode of action, adverse effects, and toxic mechanisms. The emerging critical issues in the current toxicological investigations were proposed and discussed. Our work would facilitate a better understanding of MPs-induced health hazards for toxicological evaluation and provide helpful information for regulatory decisions.
Topics: Humans; Microplastics; Pandemics
PubMed: 38043812
DOI: 10.1016/j.scitotenv.2023.168946 -
Environmental Pollution (Barking, Essex... Sep 2023Phthalates are chemicals widely used in plastic-based consumer products, and human exposure is universal. They are classified as endocrine disruptors, and specific... (Meta-Analysis)
Meta-Analysis Review
Phthalates are chemicals widely used in plastic-based consumer products, and human exposure is universal. They are classified as endocrine disruptors, and specific phthalate metabolites have been associated with an increased risk of cardiometabolic diseases. The aim of this study was to assess the association between phthalate exposure and the metabolic syndrome in the general population. A comprehensive literature search was performed in four databases (Web of Science, Medline, PubMed, and Scopus). We included all the observational studies that evaluate the association between phthalate metabolites and the metabolic syndrome available until January 31st, 2023. Pooled Odds Ratios (OR) and their 95% confidence intervals were calculated by using the inverse-variance weighted method. Nine cross-sectional studies and 25,365 participants aged from 12 to 80 were included. Comparing extreme categories of phthalate exposure, the pooled ORs for the metabolic syndrome were: 1.08 (95% CI, 1.02-1.16, I = 28%) for low molecular weight phthalates, and 1.11 (95% CI, 1.07-1.16, I = 7%) for high molecular weight phthalates. For individual phthalate metabolites, the pooled ORs that achieved statistical significance were: 1.13 (95% CI, 1.00-1.27, I = 24%) for MiBP; 1.89 (95% CI, 1.17-3.07, I = 15%) for MMP in men; 1.12 (95% CI, 1.00-1.25, I = 22%) for MCOP; 1.09 (95% CI, 0.99-1.20, I = 0%) for MCPP; 1.16 (95% CI, 1.05-1.28, I = 6%) for MBzP; and 1.16 (95% CI, 1.09-1.24, I = 14%) for DEHP (including ΣDEHP and its metabolites). In conclusion, both low molecular weight and high molecular weight phthalates were associated with an 8 and 11% higher prevalence of the MetS, respectively. The exposure to six specific phthalate metabolites was associated with a higher prevalence of the MetS.
Topics: Male; Humans; Metabolic Syndrome; Environmental Pollutants; Cross-Sectional Studies; Phthalic Acids; Plastics; Environmental Exposure
PubMed: 37328121
DOI: 10.1016/j.envpol.2023.121957 -
Dental Materials : Official Publication... Oct 2021The purpose of this systematic review and meta-analysis was to analyze the literature on the bond strength of self-etching (SE) adhesives containing 10-MDP or other... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
The purpose of this systematic review and meta-analysis was to analyze the literature on the bond strength of self-etching (SE) adhesives containing 10-MDP or other acidic functional monomers, comparing the bonding performance of both compositions.
METHODS
This study is registered in PROSPERO (CRD42020175715) and it followed the PRISMA Statement. The literature search was performed in PubMed, Web of Science, SciELO, Scopus, LILACS, IBECS, and BBO from the starting coverage date through 30 June 2021. Study eligibility criteria consisted of in vitro studies that evaluated the bond strength (microtensile, microshear, tensile or shear testing) to sound dentin/enamel of a minimum of two distinct SE systems, with at least one material containing 10-MDP and one other being comprised of a distinct acidic composition. Statistical analyses were carried out with RevMan 5.3.5 and using random-effects models with the significance level at p < 0.05. Also, Bayesian network meta-analysis (NMA) was conducted using MetaInsight V3 tool.
RESULTS
From 740 relevant studies evaluated in full-text analysis, 210 were incorporated to the systematic review and 206 in meta-analysis. The majority of studies was classified as having medium risk of bias (56.7%), followed by low (35.2%) and high (8.1%) risk of bias. Data from a total of 64 adhesive systems were collected, which favored the 10-MDP-based group at both dentin (overall effect: 6.98; 95% CI: 5.61, 8.36; p < 0.00001) and enamel (overall effect: 2.79; 95% CI: 1.62, 3.96; p < 0.00001) substrates. Microtensile testing was more frequently used (73.4%) in the included studies. Adhesives based on 10-MDP showed greater bonding performance than adhesives comprised of monomers such as PENTA, 6-MHP, 4-META, 4-MET, pyrophosphate esters, mixed composition or monomers derived from sulfonic acid (p ≤ 0.01); whereas similar bond strength values were verified between 10-MDP-based materials and those containing PEM-F, acrylamide phosphates, 4-AET, MAC-10, or monomers derived from polyacrylic and phosphonic acids (p ≥ 0.05). Adhesives based on GPDM were the only ones that resulted in greater bonding potential than the 10-MDP-based group (p = 0.03). Dental bonds in dentin were favored with the application of 2-step 10-MDP-based adhesives; whereas in enamel the dental bonds were favored for both 2-steps versions of adhesives, regardless of the presence of 10-MDP. Indirect evidence from NMA revealed that 1-step 10-MDP-free and universal 10-MDP-free adhesives seemed to perform worst in dentin and enamel, respectively.
SIGNIFICANCE
Adhesives containing 10-MDP showed higher bonding performance than materials formulated with other acidic ingredients, although this result relied on the type of mechanical testing, type of the substrate, acidic composition of the adhesive, and the application category of the SE system. This review summarized the effects of the foregoing factors on the adhesion to dental substrates.
Topics: Bayes Theorem; Dental Bonding; Dental Cements; Dentin; Dentin-Bonding Agents; Materials Testing; Methacrylates; Resin Cements; Tensile Strength
PubMed: 34456050
DOI: 10.1016/j.dental.2021.08.014 -
Odontology Oct 2019Recently, sealers based on calcium silicates were developed as a new class of endodontic sealers. Inspired by the excellent sealing ability and biocompatibility of... (Review)
Review
Recently, sealers based on calcium silicates were developed as a new class of endodontic sealers. Inspired by the excellent sealing ability and biocompatibility of calcium silicate-based cements, these sealers establish a biological point of view on the obturation of root canals. No longer, the bacteria-tight seal against reinfection of the root canal is the only goal of root canal obturation. Antibacterial properties as well as bioactive inducement of periapical healing and hard tissue formation are added to the portfolio of sealers. Ready-to-use sealers consisting of only one component with a need for external water supply from, e.g., body fluid and two components sealers with internal water supply were introduced to the market. Both of these material types have the same setting reactions in common whereby a hydration reaction of the calcium silicate is followed by a precipitation reaction of calcium phosphate. Though the available sealers are all based on calcium silicates, they consist of different compositions. Due to this aspect, differences in their physical and chemical properties as well as in their in vitro characteristics were described. Studies addressing the clinical impact of calcium silicate-based sealers on outcome are still sparse. The bioactive potential of sealers based on calcium silicates is a consequence of the slight solubility of these materials even after setting, but solubility of the sealer might also compromise the quality of sealing a root canal against regrowth and reinfection. Further clinical investigations are required to evaluate the clinical relevance of the gulf between bioactivity and solubility.
Topics: Calcium Compounds; Drug Combinations; Epoxy Resins; Materials Testing; Root Canal Filling Materials; Root Canal Obturation; Silicates
PubMed: 30554288
DOI: 10.1007/s10266-018-0400-3 -
Contact Lens & Anterior Eye : the... Oct 2023To evaluate if topical povidone iodine (alone (PI) or combined with dexamethasone (PI-DXM)) is superior to placebo for treating adenoviral conjunctivitis (AC). (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To evaluate if topical povidone iodine (alone (PI) or combined with dexamethasone (PI-DXM)) is superior to placebo for treating adenoviral conjunctivitis (AC).
METHODS
A systematic review was performed according to Preferred Reporting Items for the Systematic Review and Meta-Analyses (PRISMA) Statement. An electronic search was made on PubMed, Embase and Cochrane Library. Randomized control studies that compared PI or PI-DXM with placebo were included. At least three researchers were involved in all phases. Primary outcomes were AC duration and the number of clinical resolutions during the first week. Secondary outcomes were conjunctival redness and serous discharge one week after starting treatment and the rate of AC complications.
RESULTS
Only five studies met the inclusion criteria. PI-DXM reduced the duration of the disease by 2.4 days (IC95% 4.09-0.71), however this result was based only in one study. PI and PI-DXM did not modify the probability of clinical resolution during the first week; relative risk (RR) = 1.77 (IC95% 0.63-4.96) and 1.70 (IC95% 0.67-4.36). The impact of PI on the probability of pseudomembranes could not be estimated. PI-DXM did not influence the risk of developing subepithelial infiltrates RR = 0.73 (IC95% 0.02-33.38).
CONCLUSIONS
At this time there is great uncertainty about the usefulness of PI on the course of adenoviral conjunctivitis. PI-DXM may have a small effect on AC duration. To make future reviews possible, it is important to standardize the way in which these results are reported. Futures studies should include etiological confirmation, unit of study (eyes vs patients) and report on those aspects that are more relevant for patient quality of life (duration of the disease, development of complications: pseudomembranes and subepithelial infiltrates).
Topics: Humans; Povidone-Iodine; Povidone; Quality of Life; Conjunctivitis
PubMed: 37380515
DOI: 10.1016/j.clae.2023.101873 -
The Journal of Evidence-based Dental... Dec 2023The aim of this systematic review was to evaluate the survival and complication rates of resin composite laminate veneers. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
The aim of this systematic review was to evaluate the survival and complication rates of resin composite laminate veneers.
METHODS
Randomized controlled trials and cohort studies with a minimum 2-year follow-up assessing survival and complication rates of resin composite laminate veneers on permanent dentition from 1998 to May 2022. Literature searches were conducted in MEDLINE (PubMed), Scopus, and the Cochrane Central Register of Controlled Trials electronic databases. References cited in the related reviews and included full-text articles were also hand-searched to further identify potentially relevant studies.
RESULTS
A total of 827 articles were identified. Twenty-two studies were considered for full-text review after the title and abstract screening stage. After exclusion, 7 studies (3 randomized controlled trials and 4 cohort studies) were included in the systematic review. Three published scales were adopted for the quality and risk of bias assessment. At the survival rate threshold, the overall heterogeneity (I) for randomized controlled trials was 50.5% (P = .108). The overall pooled survival rate of the randomized controlled trials was 88% (95% CI: 81%-94%), with the mean follow-up time ranging from 24 to 97 months. Surface roughness, color mismatch, and marginal discoloration were the most reported complications.
CONCLUSION
Resin composite laminate veneers demonstrated moderately high survival rates for the entire sample and the direct laminate veneer group demonstrated higher survival rates than the indirect approach. Most of the complications were regarded as clinically acceptable with or without reintervention.
Topics: Humans; Dental Porcelain; Composite Resins; Dental Restoration Failure
PubMed: 38035903
DOI: 10.1016/j.jebdp.2023.101911 -
Journal of Prosthodontics : Official... Jun 2022To systematically review past studies to determine the effect of various solutions on the color of denture teeth, thus answering the question in regards to which type of... (Review)
Review
PURPOSE
To systematically review past studies to determine the effect of various solutions on the color of denture teeth, thus answering the question in regards to which type of denture teeth has the best optical properties after exposure to various solutions. The method of measuring the color of artificial teeth was also evaluated as a secondary outcome.
MATERIALS AND METHODS
A search of studies that quantitatively investigated the influence of immersion solutions on the color change of denture teeth was conducted. Ovid MEDLINE, PubMed and Scopus databases were searched from 1997 to April 2021. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used during article selection. Data regarding the effect of immersion solutions, accelerated aging and surface treatments on color change were gathered. Methodologies used to assess optical properties were also summarized and compared. The modified CONSORT checklist was used to determine the risk of bias of past studied included in this review.
RESULTS
One hundred thirty-three studies were identified after removing duplicates. Forty-one studies were selected for full-text analysis, and 35 remaining papers met the inclusion criteria and were therefore included in this systematic review. Thirty-two in vitro studies and 3 in vivo studies were included in the review. All studies reported that immersion in various solutions has a significant influence on the change in color and optical properties of denture teeth. However, the discoloration of denture teeth is still clinically acceptable in most studies. Exposure to various solutions also affected the translucency parameter of denture teeth. Most studies also investigated the surface roughness and hardness along with the optical properties, and reported that immersion cycles did not cause changes in surface roughness of denture teeth, while hardness was affected. The optical properties of PMMA denture teeth have been studied extensively, whereas that of CAD/CAM and 3D printed denture teeth is limited.
CONCLUSIONS
Color stability of CAD/CAM milled denture teeth is comparable to conventional PMMA denture teeth. There are contradictory findings in terms of color stability of 3D printed denture teeth as compared to conventional PMMA denture teeth. Staining by coffee is worst among the common beverages and solutions investigated. Denture teeth can show color changes after immersion in staining beverages as early as one week. The degree of discoloration of denture teeth after immersion is time dependent, with the larger extent in the initial phase.
Topics: Acrylic Resins; Color; Materials Testing; Polymethyl Methacrylate; Surface Properties
PubMed: 34516027
DOI: 10.1111/jopr.13429 -
Dental Materials : Official Publication... May 2022The present review is an update of a systematic review that has been published in 2012. Meanwhile, many new clinical trials on resin composites had been published. New... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
The present review is an update of a systematic review that has been published in 2012. Meanwhile, many new clinical trials on resin composites had been published. New materials such as bulk fill resin composites and new glass-ionomer (GIC) based materials had been introduced. The focus of this review was to evaluate the longevity in relation to the material class and adhesive class, while adjusting for a possible study bias effect.
MATERIAL AND METHODS
The database PUBMED/SCOPUS were searched for clinical trials on posterior resin composites. The inclusion criteria were: (1) studies published between 2000 and 2019, (2) prospective clinical trial with at least 2 years of observation; (2) minimal number of restorations at last recall = 20; (3) report on drop-out rate; (4) report of operative technique and used materials; (5) utilisation of Ryge, modified Ryge or FDI evaluation criteria. The bias of each study was assessed by two independent reviewers using Cochrane Collaboration's tool for assessing risk of bias in randomised trials. For the statistical analysis, linear mixed models fitted on the individual data recorded along time have been used with random effects to account for study, patients and experiment effects. P-values smaller than 0.05 were considered significant.
RESULTS
Of the 423 clinical trials, 62 studies (including 110 experiments) met the inclusion criteria. Material class was divided according to the composite filler in microhybrid (39 experiments/2807 restorations), nanohybrid (24 experiments/1254 restorations), and hybrid (22 experiments/1255 restorations). So-called bulk fill materials were treated as a separate category (9 experiments/506 restorations) as were the GIC (11 experiments/2121 restorations) and the compomer materials (5 experiments/238 restorations). Only one study (1.6%) had low risk of bias, 42 (67.7%) were assessed to have unclear risk of bias and 19 (30.6%) had a high risk of bias. In 52.3% of the studies Class II and Class I restorations had been placed. After 10 years, the survival rate for resin composite restorations dropped to about 85-90% with no significant difference between hybrid, microhybrid and nao-hybrid resin materials. The main reasons for restoration replacement were bulk fractures and wear, which accounted for a about 70% of replacements. Caries at the restorative margins accounted for about 20% of the replacements, and retention loss, inacceptable colour match or marginal integrity, endodontic treatment or cusp fracture for about 10% of the replacements of the resin composite restorations. For compomer and GIC restorations the mean overall survival rate was about 80% after 6 years. For GIC, the main reasons for failure were substantial loss of anatomical contour along with loss of proximal contacts and retention loss. Mainly fractures reduced the longevity of compomers restorations. Also, there was no statistically significant difference between hybrid, micro-hybrid, nano-hybrid and bulk fill resin composites with regard to colour match, surface texture, material fractures, and anatomical form.
CONCLUSIONS
Posterior resin composite restorations that were placed with the enamel etch technique showed the best overall performance; the longevity was not significantly influenced by the filler type or viscosity of resin composite material. With regard to colour match, surface texture and anatomical form, nanohybrid resins were not significantly superior to hybrid or microhybrid resin composites. Compomer and GIC restorations demonstrated considerable shortcomings and had a significant shorter longevity.
Topics: Compomers; Composite Resins; Dental Caries; Dental Restoration, Permanent; Glass Ionomer Cements; Humans; Prospective Studies; Treatment Outcome
PubMed: 35221127
DOI: 10.1016/j.dental.2021.10.018 -
Clinical Nephrology Jun 2017The relationship between the sieving coefficient (SC) or extraction ratio (ER) and the molecular weight (MW) of peptide and protein solutes during hemofiltration has not... (Review)
Review
The relationship between the sieving coefficient (SC) or extraction ratio (ER) and the molecular weight (MW) of peptide and protein solutes during hemofiltration has not been investigated; it is possible that the SC and ER correlate with MW, permitting an estimate of peptide and protein clearance by hemofiltration in the absence of empiric data. A search for studies of the SC and/or ER for peptide and protein solutes during hemofiltration identified data for β-microglobulin, brain natriuretic peptide, carperitide, IL-1β, IL-1RA, IL-6, IL-8, lysozyme, myoglobin, neutrophil gelatinase-associated lipocalin, procalcitonin, retinol-binding protein, TNF-α, soluble TNFR-1, soluble TNFR-II, and vasopressin using polyacrylonitrile, polysulfone, polyamide, and cellulose hemofilters. The SC correlated with MW using polyacrylonitrile, polyamide, and cellulose hemofilters. With fewer data, the ER did not correlate with MW using polyacrylonitrile hemofilters, and not enough data were available to assess the ER with any other hemofilters. These results may help predict peptide and protein convective clearance during hemofiltration with polyacrylonitrile, polyamide, and cellulose hemofilters when empiric data are not available. .
Topics: Acrylic Resins; Blood Proteins; Hemofiltration; Humans
PubMed: 28211786
DOI: 10.5414/CN108841