Clinical Anatomy (New York, N.Y.) Jan 2024Ventricular false tendons are fibromuscular structures that travel across the ventricular cavity. Left ventricular false tendons (LVFTs) have been examined through gross... (Meta-Analysis)
Meta-Analysis Review
Ventricular false tendons are fibromuscular structures that travel across the ventricular cavity. Left ventricular false tendons (LVFTs) have been examined through gross dissection and echocardiography. This study aimed to comprehensively evaluate the prevalence, morphology, and clinical importance of ventricular false tendons using a systematic review. In multiple studies, these structures have had a wide reported prevalence ranging from less than 1% to 100% of cases. This meta-analysis found the overall pooled prevalence of LVFTs to be 30.2%. Subgroup analysis indicated the prevalence to be 55.1% in cadaveric studies and 24.5% in living patients predominantly studied by echocardiography. Morphologically, left and right ventricular false tendons have been classified into several types based on their location and attachments. Studies have demonstrated false tendons have important clinical implications involving innocent murmurs, premature ventricular contractions, early repolarization, and impairment of systolic and diastolic function. Despite these potential complications, there is evidence demonstrating that the presence of false tendons can lead to positive clinical outcomes.
Topics: Humans; Heart Ventricles; Heart Defects, Congenital; Echocardiography; Clinical Relevance; Dissection
PubMed: 37819143
DOI: 10.1002/ca.24116 -
The Annals of Thoracic Surgery 2015It remains unclear as to whether mechanical valves have a role in pulmonary valve replacement. A systematic review and meta-analysis was performed to answer this... (Meta-Analysis)
Meta-Analysis Review
It remains unclear as to whether mechanical valves have a role in pulmonary valve replacement. A systematic review and meta-analysis was performed to answer this question. Nineteen observational studies, including 299 pediatric and adult patients with a mean follow-up of 73 months, were analyzed. Nonstructural valve deterioration and valve thrombosis occurred in 1.5% and 2.2% of patients, respectively. Surgical reintervention was required in 0.9% of cases and thrombolysis was required in 0.5%. Mechanical valves in the pulmonary position are associated with a low incidence of valve deterioration and thrombosis, as well as freedom from reoperation and thrombolysis.
Topics: Cardiac Surgical Procedures; Heart Valve Prosthesis; Heart Ventricles; Humans; Prosthesis Design; Pulmonary Valve
PubMed: 25795296
DOI: 10.1016/j.athoracsur.2014.11.058 -
Cardiology in Review Mar 2023This study reviews the published data comparing the efficacy and safety of apical and septal right ventricle defibrillator lead positioning at 1-year follow-up. Systemic...
This study reviews the published data comparing the efficacy and safety of apical and septal right ventricle defibrillator lead positioning at 1-year follow-up. Systemic research on Medline (PubMed), ClinicalTrials.gov, and Embase was performed using the keywords "septal defibrillation," "apical defibrillation," "site defibrillation," and "defibrillation lead placement," including implantable cardioverter-defibrillator and cardiac resynchronization therapy devices. Comparisons between apical and septal position were performed regarding R-wave amplitude, pacing threshold at a pulse width of 0.5 ms, pacing and shock lead impedance, suboptimal lead performance, left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter, readmissions due to heart failure and mortality rates. A total of 5 studies comprising 1438 patients were included in the analysis. Mean age was 64.5 years, 76.9% were male, with a median LVEF of 27.8%, ischemic etiology in 51.1%, and a mean follow-up period of 26.5 months. The apical lead placement was performed in 743 patients and septal lead placement in 690 patients. Comparing the 2 placement sites, no significant differences were found regarding R-wave amplitude, lead impedance, suboptimal lead performance, LVEF, left ventricular end-diastolic diameter, and mortality rate at 1-year follow-up. Pacing threshold values favored septal defibrillator lead placement (P = 0.003), as well as shock impedance (P = 0.009) and readmissions due to heart failure (P = 0.02). Among patients receiving a defibrillator lead, only pacing threshold, shock lead impedance, and readmission due to heart failure showed results favoring septal lead placement. Therefore, generally, the right ventricle lead placement does not appear to be of major importance.
PubMed: 36883833
DOI: 10.1097/CRD.0000000000000527 -
European Radiology Dec 2019Right ventricular function (RVF) is a strong predictor of adverse cardiac events; however, the reference standard for RVF assessment, MRI, is limited in some patients... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Right ventricular function (RVF) is a strong predictor of adverse cardiac events; however, the reference standard for RVF assessment, MRI, is limited in some patients for whom accurate evaluation of RVF is essential, like those with COPD or non-MR compatible metal implants. We conducted this meta-analysis to evaluate whether CT was as accurate as MRI for the assessment of RVF.
METHOD
We conducted a meta-analysis of studies retrieved from PubMed, Embase, and Cochrane Central searches to evaluate the differences and correlations between the following RVF parameters as measured by CT and MRI: end diastole volume (EDV), end systole volume (ESV), right ventricular ejection fraction (RVEF), and stroke volume (SV).
RESULTS
Sixteen studies that used disk summation (637 subjects) and three studies that used three-dimensional reconstruction were included. For the 16 studies, the pooled standard mean differences (95% confidence interval) were 1.04 (- 2.59, 4.67) for EDV, 1.22 (1.50, 3.95) for ESV, - 0.65 (- 2.60, 1.29) for RVEF, and - 0.37 (- 3.64, 2.90) for SV. The overall correlation coefficient (r) values were 0.98 for EDV, 0.95 for ESV, 0.98 for RVEF, and 0.97 for SV. The mean difference between the two methods was not statistically significant (overall effect Z test, p > 0.1).
CONCLUSION
CT can assess RVF with accuracy comparable to that of MRI. Thus, CT is a valid alternative to MRI.
KEY POINTS
• CT could help clinicians to assess RVF as accurately as MRI can, with satisfactory repeatability.
Topics: Female; Heart Ventricles; Humans; Magnetic Resonance Imaging; Male; Middle Aged; Stroke Volume; Tomography, X-Ray Computed; Ventricular Dysfunction, Right; Ventricular Function, Right
PubMed: 31134368
DOI: 10.1007/s00330-019-06228-2 -
Medical Sciences (Basel, Switzerland) Apr 2023Atrial fibrillation (AF) is the most common pathological arrhythmia, and its complications lead to significant morbidity and mortality. However, patients with AF can... (Review)
Review
BACKGROUND
Atrial fibrillation (AF) is the most common pathological arrhythmia, and its complications lead to significant morbidity and mortality. However, patients with AF can often go undetected, especially if they are asymptomatic or have a low burden of paroxysms. Identification of those at high risk of AF development may help refine screening and management strategies.
METHODS
PubMed and Embase databases were systematically searched for studies looking at electrocardiographic predictors of AF from inception to August 2021.
RESULTS
A total of 115 studies were reported which examined a combination of atrial and ventricular parameters that could be electrocardiographic predictors of AF. Atrial predictors include conduction parameters, such as the PR interval, p-wave index and dispersion, and partial interatrial or advanced interatrial block, or morphological parameters, such as p-wave axis, amplitude and terminal force. Ventricular predictors include abnormalities in QRS amplitude, morphology or duration, QT interval duration, r-wave progression and ST segment, i.e., t-wave abnormalities.
CONCLUSIONS
There has been significant interest in electrocardiographic prediction of AF, especially in populations at high risk of atrial AF, such as those with an embolic stroke of undetermined source. This review highlights the breadth of possible predictive parameters, and possible pathological bases for the predictive role of each parameter are proposed.
Topics: Humans; Atrial Fibrillation; Electrocardiography; Heart Atria; Heart Rate; Heart Ventricles
PubMed: 37092499
DOI: 10.3390/medsci11020030 -
The American Journal of Cardiology May 2023Neuroendocrine tumors (NETs) are a rare group of malignancies which are aggressive and widely metastatic. Cardiac metastases (CMs) are rarely reported because of NET. We... (Meta-Analysis)
Meta-Analysis
Neuroendocrine tumors (NETs) are a rare group of malignancies which are aggressive and widely metastatic. Cardiac metastases (CMs) are rarely reported because of NET. We aim to analyze the available literature to study the proportional prevalence of CM because of NET and its location and effect on the ejection fraction (EF) and survival rate. Our search strategy and meta-analysis are in line with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) AMSTAR-2 (Assessing the methodological quality of systematic Reviews-2) Guidelines. A literature search was conducted on MEDLINE (EMBASE and PubMed) for randomized clinical trials, pilot trials, and retrospective and prospective studies. Statistical analysis was performed using the CRAN-R software (https://CRAN.R-project.org/doc/FAQ/R-FAQ.html). The quality assessment of the included articles was performed using the Cochrane Risk of Bias and Newcastle-Ottawa Scale. A total of 16,685 patients were included in the study. The mean age of patients included in the study was 61.28 ± SD 9.89 years. Of these, 257 patients had a total of 283 CM. Metastasis was mainly located in the left ventricle with a pooled proportion of 0.48, 95% confidence interval (CI) 0.4 to 0.56, pericardium: 0.34, 95% CI 0.19 to 0.53, right ventricle 0.28, 95% CI 0.16 to 0.44, interventricular septum 0.25, 95% CI 0.16 to 0.37, left atrium 0.1, 95% CI 0.03 to 0.26 and right atrium 0.05, 95% CI 0.01 to 0.20. Decrease in EF at the time of CM diagnosis was the effect most consistently reported in patients with CM. Pooled mean survival was 35.89, 95% CI 8.27 to 155.68 months after the diagnosis of CM. CM due to NET was <2% and the left ventricle is the most common metastatic location, followed by the pericardium. Decreased EF was the most common clinical picture observed. Further studies are needed to analyze the clinical impact of NET CM.
Topics: Humans; Middle Aged; Prospective Studies; Prevalence; Retrospective Studies; Melanoma; Melanoma, Cutaneous Malignant
PubMed: 36996525
DOI: 10.1016/j.amjcard.2023.02.011 -
Journal of Electrocardiology 2017We aimed to study the effect of right ventricular implantable cardioverter defibrillator (ICD) lead positioning on clinical outcomes in patients undergoing ICD placement. (Meta-Analysis)
Meta-Analysis Review
INTRODUCTION
We aimed to study the effect of right ventricular implantable cardioverter defibrillator (ICD) lead positioning on clinical outcomes in patients undergoing ICD placement.
METHODS
A systematic literature search was performed using PubMed, EMBASE, Web of Science, and Cochrane Central Register of Controlled Trials to identify clinical trials comparing outcomes in patients with ICD leads in apical and non-apical positions. The primary outcome of our study was death at 1-year follow-up. Secondary outcomes studied were "death at 3years", "total number of shocks", "appropriate shocks", "inappropriate shocks" and "cut-to-suture time".
RESULTS
We analyzed a total of 3731 patients (2852 in apical and 879 in non-apical ICD groups) enrolled in 4 clinical trials. No significant difference was observed between the apical and non-apical ICD groups in all-cause mortality at 1year (OR 0.88; 95% CI 0.51-1.49, p=0.63; I=5.32%). Similarly, no differences were seen between the two groups in death at 3years (OR=0.76; 95% CI 0.56-1.04, p=0.08; I=0%), total number of shocks (OR 0.99; 95% CI 0.81-1.22, p=0.95; I=0%), appropriate shocks (OR 1.00; 95% CI 0.79-1.27, p=0.99; I=0%), inappropriate shocks (OR 0.98; 95% CI 0.70-1.37, p=0.91; I=0%) and cut-to-suture time (Standard mean difference=-0.03; 95% CI -0.20 to 0.14, p=0.73; I=0%). No publication bias was seen.
CONCLUSION
Non-apical RV ICD lead implantation is non-inferior to traditional RV apical position with no significant differences in mortality, total number of shocks, appropriate shocks, inappropriate shocks and procedural time.
Topics: Defibrillators, Implantable; Electrodes, Implanted; Heart Ventricles; Humans
PubMed: 28554513
DOI: 10.1016/j.jelectrocard.2017.05.003 -
JACC. Cardiovascular Imaging Jun 2024Functional tricuspid regurgitation (TR) can develop either because of right ventricular (RV) remodeling (ventricular functional TR) and/or right atrial dilation (atrial... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Functional tricuspid regurgitation (TR) can develop either because of right ventricular (RV) remodeling (ventricular functional TR) and/or right atrial dilation (atrial functional TR).
OBJECTIVES
This meta-analysis aimed to investigate the association between right heart remodeling and long-term (>1 year) all-cause mortality in patients with significant TR (at least moderate, ≥2+).
METHODS
MEDLINE, ISI Web of Science, and SCOPUS databases were searched. Studies reporting data on at least 1 RV functional parameter and long-term all-cause mortality in patients with significant TR were included. This study was designed according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) requirements.
RESULTS
Out of 8,902 studies, a total of 14 were included, enrolling 4,394 subjects. The duration of follow-up across the studies varied, ranging from a minimum of 15.5 months to a maximum of 73.2 months. Overall, long-term all-cause mortality was 31% (95% CI: 20%-41%; P ≤ 0.001). By means of meta-regression analyses, an inverse relation was found between tricuspid annular plane systolic excursion (11 studies enrolling 3,551 subjects, -6.3% [95% CI: -11.1% to -1.4%]; P = 0.011), RV fractional area change (9 studies, 2,975 subjects, -4.4% [95% CI: -5.9% to -2.9%]; P < 0.001), tricuspid annular dimension (7 studies, 2,986 subjects, -4.1% [95% CI: -7.6% to -0.5%]; P = 0.026), right atrial area (6 studies, 1,920 subjects, -1.9% [95% CI: -2.5% to -1.3%]; P < 0.001) and mortality.
CONCLUSIONS
RV dysfunction parameters are associated to worse clinical outcomes in patients with TR, whereas right atrial dilatation is linked to a better prognostic outcome. Further studies are needed to unravel the pathophysiological differences within the functional TR spectrum. (Right heart remodeling and outcomes in patients with tricuspid regurgitation; CRD42023418667).
Topics: Humans; Tricuspid Valve Insufficiency; Ventricular Remodeling; Ventricular Function, Right; Risk Factors; Time Factors; Prognosis; Male; Middle Aged; Female; Aged; Atrial Function, Right; Tricuspid Valve; Adult; Risk Assessment; Aged, 80 and over; Ventricular Dysfunction, Right; Atrial Remodeling
PubMed: 38430099
DOI: 10.1016/j.jcmg.2023.12.011 -
Journal of the American Heart... Jul 2021Background Leadless pacemaker is a novel technology, and evidence supporting its use is uncertain. We performed a systematic review and meta-analysis to examine the... (Meta-Analysis)
Meta-Analysis
Background Leadless pacemaker is a novel technology, and evidence supporting its use is uncertain. We performed a systematic review and meta-analysis to examine the safety and efficacy of leadless pacemakers implanted in the right ventricle. Methods and Results We searched PubMed and Embase for studies published before June 6, 2020. The primary safety outcome was major complications, whereas the primary efficacy end point was acceptable pacing capture threshold (≤2 V). Pooled estimates were calculated using the Freedman-Tukey double arcsine transformation. Of 1281 records screened, we identified 36 observational studies of Nanostim and Micra leadless pacemakers, with most (69.4%) reporting outcomes for the Micra. For Micra, the pooled incidence of complications at 90 days (n=1608) was 0.46% (95% CI, 0.08%-1.05%) and at 1 year (n=3194) was 1.77% (95% CI, 0.76%-3.07%). In 5 studies with up to 1-year follow-up, Micra was associated with 51% lower odds of complications compared with transvenous pacemakers (3.30% versus 7.43%; odds ratio [OR], 0.49; 95% CI, 0.34-0.70). At 1 year, 98.96% (95% CI, 97.26%-99.94%) of 1376 patients implanted with Micra had good pacing capture thresholds. For Nanostim, the reported complication incidence ranged from 6.06% to 23.54% at 90 days and 5.33% to 6.67% at 1 year, with 90% to 100% having good pacing capture thresholds at 1 year (pooled result not estimated because of the low number of studies). Conclusions Most studies report outcomes for the Micra, which is associated with a low risk of complications and good electrical performance up to 1-year after implantation. Further data from randomized controlled trials are needed to support the widespread adoption of these devices in clinical practice.
Topics: Arrhythmias, Cardiac; Cardiac Pacing, Artificial; Equipment Design; Heart Ventricles; Humans; Pacemaker, Artificial; Treatment Outcome
PubMed: 34169736
DOI: 10.1161/JAHA.120.019212 -
Cardiovascular Pathology : the Official... 2023While primary cardiac tumors are rare, it has been increasingly recognized due to improvement in screening measures. However, the hamartoma of mature cardiac myocytes... (Review)
Review
BACKGROUND
While primary cardiac tumors are rare, it has been increasingly recognized due to improvement in screening measures. However, the hamartoma of mature cardiac myocytes has been underrecognized compared to other cardiac tumors, such as cardiac myxomas and papillary fibroelastomas, and is still potentially associated with critical consequences such as sudden death. This systematic review aims to summarize the evidence regarding the hamartoma of mature cardiac myocytes and characterize the presentations and symptoms for clinicians.
METHODS
Following the PRISMA statement, we searched MEDLINE and EMBASE for all peer-reviewed articles using keywords including "hamartoma of mature cardiac myocytes" from their inception to January 2, 2023.
RESULTS
We included 25 articles, including 34 cases, in this systematic review. Patients with hamartoma of mature cardiac myocytes commonly presented with nonspecific symptoms such as dyspnea (35.3%), although a few presented with sudden death and syncope. The left ventricle was the common site of origin (41.2%), followed by the right atrium and ventricle. Surgery was commonly pursued for diagnosis and treatment, while a few required cardiac transplants (8.8%), and 29.4% were diagnosed with autopsy or expired.
CONCLUSION
Hamartoma of mature cardiac myocytes is a potentially underrecognized primary cardiac tumor associated with treatable yet potentially critical consequences. Given the challenges of differentiating it from malignancy such as angiosarcoma, multimodal imaging needs to be utilized to pursue a diagnosis. Future studies are warranted to develop a noninvasive diagnosis mode for cardiac tumor.
Topics: Humans; Myocytes, Cardiac; Heart Neoplasms; Heart Ventricles; Hamartoma; Death, Sudden
PubMed: 37031829
DOI: 10.1016/j.carpath.2023.107538