JAMA Pediatrics Dec 2019Reliable estimates of the prevalence of childhood hypertension serve as the basis for adequate prevention and treatment. However, the prevalence of childhood... (Meta-Analysis)
Meta-Analysis
IMPORTANCE
Reliable estimates of the prevalence of childhood hypertension serve as the basis for adequate prevention and treatment. However, the prevalence of childhood hypertension has rarely been synthesized at the global level.
OBJECTIVE
To conduct a systematic review and meta-analysis to assess the prevalence of hypertension in the general pediatric population.
DATA SOURCES
PubMed, MEDLINE, Embase, Global Health, and Global Health Library were searched from inception until June 2018, using search terms related to hypertension (hypertension OR high blood pressure OR elevated blood pressure), children (children OR adolescents), and prevalence (prevalence OR epidemiology).
STUDY SELECTION
Studies that were conducted in the general pediatric population and quantified the prevalence of childhood hypertension were eligible. Included studies had blood pressure measurements from at least 3 separate occasions.
DATA EXTRACTION AND SYNTHESIS
Two authors independently extracted data. Random-effects meta-analysis was used to derive the pooled prevalence. Variations in the prevalence estimates in different subgroups, including age group, sex, setting, device, investigation period, BMI group, World Health Organization region and World Bank region, were examined by subgroup meta-analysis. Meta-regression was used to establish the age-specific prevalence of childhood hypertension and to assess its secular trend.
MAIN OUTCOMES AND MEASURES
Prevalence of childhood hypertension overall and by subgroup.
RESULTS
A total of 47 articles were included in the meta-analysis. The pooled prevalence was 4.00% (95% CI, 3.29%-4.78%) for hypertension, 9.67% (95% CI, 7.26%-12.38%) for prehypertension, 4.00% (95% CI, 2.10%-6.48%) for stage 1 hypertension, and 0.95% (95% CI, 0.48%-1.57%) for stage 2 hypertension in children 19 years and younger. In subgroup meta-analyses, the prevalence of childhood hypertension was higher when measured by aneroid sphygmomanometer (7.23% vs 4.59% by mercury sphygmomanometer vs 2.94% by oscillometric sphygmomanometer) and among overweight and obese children (15.27% and 4.99% vs 1.90% among normal-weight children). A trend of increasing prevalence of childhood hypertension was observed during the past 2 decades, with a relative increasing rate of 75% to 79% from 2000 to 2015. In 2015, the prevalence of hypertension ranged from 4.32% (95% CI, 2.79%-6.63%) among children aged 6 years to 3.28% (95% CI, 2.25%-4.77%) among those aged 19 years and peaked at 7.89% (95% CI, 5.75%-10.75%) among those aged 14 years.
CONCLUSIONS AND RELEVANCE
This study provides a global estimation of childhood hypertension prevalence based on blood pressure measurements in at least 3 separate visits. More high-quality epidemiologic investigations on childhood hypertension are still needed.
Topics: Child; Global Health; Humans; Hypertension; Prevalence
PubMed: 31589252
DOI: 10.1001/jamapediatrics.2019.3310 -
Physiotherapy Theory and Practice Feb 2015Muscle strength measurement is a key component of physiotherapists' assessment and is frequently used as an outcome measure. A sphygmomanometer is an instrument commonly... (Review)
Review
BACKGROUND
Muscle strength measurement is a key component of physiotherapists' assessment and is frequently used as an outcome measure. A sphygmomanometer is an instrument commonly used to measure blood pressure that can be potentially used as a tool to assess isometric muscle strength.
OBJECTIVE
To systematically review the evidence on the reliability and validity of a sphygmomanometer for measuring isometric strength of hip muscles.
METHOD
A literature search was conducted across four databases. Studies were eligible if they presented data on reliability and/or validity, used a sphygmomanometer to measure isometric muscle strength of the hip region, and were peer reviewed. The individual studies were evaluated for quality using a standardized critical appraisal tool.
RESULTS
A total of 644 articles were screened for eligibility, with five articles chosen for inclusion. The use of a sphygmomanometer to objectively assess isometric muscle strength of the hip muscles appears to be reliable with intraclass correlation coefficient values ranging from 0.66 to 0.94 in elderly and young populations. No studies were identified that have assessed the validity of a sphygmomanometer.
CONCLUSION
The sphygmomanometer appears to be reliable for assessment of isometric muscle strength around the hip joint, but further research is warranted to establish its validity.
Topics: Hip Joint; Humans; Isometric Contraction; Muscle Strength; Observer Variation; Sphygmomanometers
PubMed: 25286193
DOI: 10.3109/09593985.2014.963905 -
Journal of Hypertension Feb 2017The phase-out of mercury from clinical settings calls for valid alternatives to assess blood pressure (BP) in children. Aneroid devices provide a mercury-free... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The phase-out of mercury from clinical settings calls for valid alternatives to assess blood pressure (BP) in children. Aneroid devices provide a mercury-free alternative to BP measurements by auscultation, whereas oscillometric (automated) devices are increasingly becoming the norm in clinical practice due to their ease of use. The aim of this systematic review and meta-analysis was to investigate the accuracy of oscillometric and aneroid BP devices compared with the mercury sphygmomanometer for the measurement of BP in children.
METHODS
We systematically searched four electronic databases (MEDLINE, Embase, CINAHL, and Web of Science) and relevant journals for eligible articles published before 30 July 2015. We screened 1415 articles, and two authors independently reviewed 92 full-text articles.
RESULTS
We included 29 articles (38 studies) with 26 879 children. Random-effects model meta-analyses revealed that oscillometric devices yield higher measurements of SBP than auscultation with a mercury sphygmomanometer (pooled effect estimate 2.53 mmHg; 95% CI 0.57-4.50; P < 0.05); the pooled effect estimate for SBP was smaller in studies that 'passed' validation protocols (1.76 mmHg; 95% CI 0.61-2.81; n = 12). There was no significant difference for DBP (pooled effect estimate 1.55 mmHg; 95% CI -0.20 to 3.31). There was heterogeneity between studies, explained in part by differences in manufacturer, study setting and observer training. Only three studies compared BP using aneroid and mercury devices and found comparable results.
CONCLUSION
Oscillometric devices may serve as a suitable alternative to auscultation for initial BP screening in the pediatric population.
Topics: Auscultation; Blood Pressure; Blood Pressure Determination; Child; Humans; Oscillometry; Reproducibility of Results; Sphygmomanometers
PubMed: 27870656
DOI: 10.1097/HJH.0000000000001178 -
Journal of Clinical Nursing Mar 2011To compare the accuracy and appropriateness of auscultatory (manual) and oscillometric (automated) devices for measuring blood pressure in clinical settings. (Review)
Review
AIMS AND OBJECTIVES
To compare the accuracy and appropriateness of auscultatory (manual) and oscillometric (automated) devices for measuring blood pressure in clinical settings.
BACKGROUND
Accurate measurement of blood pressure is integral to early recognition of deterioration in the condition of a patient. Despite recommendations regarding the use of auscultatory devices in situations where treatment decisions are made dependent on blood readings, the use of automated machines is becoming common practice.
DESIGN
Systematic review.
METHODS
A search of the Medline, CINAHLPlus and The Cochrane Library databases was undertaken for papers published in English between January 1997-May 2009. Sixteen studies were identified that fulfilled the inclusion criteria. After quality assessment, all were included in the review. Results are presented in tabular and narrative form.
RESULTS
In 10 of the studies reviewed, the authors came to the conclusion that oscillometric devices were less accurate than auscultatory devices. However, in most cases the oscillometric device appears sufficiently accurate for clinical use, the exceptions being use with hypertensive patients, patients with arrhythmia and after trauma. Only two studies assessed the comparative accuracy of aneroid devices, and these indicated that they were more accurate than oscillometric devices, but the differences were not clinically important.
CONCLUSIONS
There are situations where the substitution of oscillometric for auscultatory devices could have particularly serious repercussions for the patient, such as when the patient is either hypertensive or hypotensive. However, further research is required on the use of aneroid sphygmomanometers as a replacement for mercury devices.
RELEVANCE TO CLINICAL PRACTICE
Practitioners should be made aware of the need to use auscultatory devices in specific circumstances, such as in management of hypertension, after the patient has experienced trauma or where there is significant potential for deterioration in the patient's condition.
Topics: Automation; Blood Pressure; Humans; Reproducibility of Results
PubMed: 21320189
DOI: 10.1111/j.1365-2702.2010.03528.x -
Anesthesiology May 2014Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a... (Comparative Study)
Comparative Study Meta-Analysis Review
BACKGROUND
Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis.
METHODS
The authors performed a systematic review and meta-analysis of studies comparing continuous noninvasive arterial pressure monitoring with invasive arterial pressure monitoring. Random-effects pooled bias and SD of bias for systolic arterial pressure, diastolic arterial pressure, and mean arterial pressure were calculated. Continuous noninvasive arterial pressure monitoring was considered acceptable if pooled estimates of bias and SD were not greater than 5 and 8 mmHg, respectively, as recommended by the Association for the Advancement of Medical Instrumentation.
RESULTS
Twenty-eight studies (919 patients) were included. The overall random-effect pooled bias and SD were -1.6 ± 12.2 mmHg (95% limits of agreement -25.5 to 22.2 mmHg) for systolic arterial pressure, 5.3 ± 8.3 mmHg (-11.0 to 21.6 mmHg) for diastolic arterial pressure, and 3.2 ± 8.4 mmHg (-13.4 to 19.7 mmHg) for mean arterial pressure. In 14 studies focusing on currently commercially available devices, bias and SD were -1.8 ± 12.4 mmHg (-26.2 to 22.5 mmHg) for systolic arterial pressure, 6.0 ± 8.6 mmHg (-10.9 to 22.9 mmHg) for diastolic arterial pressure, and 3.9 ± 8.7 mmHg (-13.1 to 21.0 mmHg) for mean arterial pressure.
CONCLUSIONS
The results from this meta-analysis found that inaccuracy and imprecision of continuous noninvasive arterial pressure monitoring devices are larger than what was defined as acceptable. This may have implications for clinical situations where continuous noninvasive arterial pressure is being used for patient care decisions.
Topics: Arterial Pressure; Blood Pressure Determination; Blood Pressure Monitoring, Ambulatory; Blood Pressure Monitors; Humans
PubMed: 24637618
DOI: 10.1097/ALN.0000000000000226 -
European Journal of Pediatrics Jan 2022With the progressive elimination of mercury column devices for blood pressure (BP) measurement in children and adolescents, valid alternatives are needed. Oscillometric... (Meta-Analysis)
Meta-Analysis Review
Blood pressure measurement in pediatric population: comparison between automated oscillometric devices and mercury sphygmomanometers-a systematic review and meta-analysis.
With the progressive elimination of mercury column devices for blood pressure (BP) measurement in children and adolescents, valid alternatives are needed. Oscillometric devices provide a replacement without mercury, are fully automated, and have excellent reliability among evaluators. Here, the goal was to test the accuracy of automatic blood pressure monitor devices compared to the mercury sphygmomanometer for BP measurement in children and adolescents. Electronic databases are EMBASE, MEDLINE (PubMed), SCOPUS, and Web of Science. We selected 8974 potentially eligible articles and two authors independently. We separately reviewed 370 full papers. Potentially eligible articles were selected according to the following criteria: (a) articles published in Portuguese, English, and Spanish; (b) screening of titles; (c) screening of abstracts; and (d) retrieval and screening of the full article to determine whether it met the inclusion criteria. We included 45 articles for analysis, 28 of which were selected for meta-analysis. The systolic BP measured by automatic blood pressure monitors presents 1.17 mmHg on average (95% CI 0.85; 1.48); for diastolic BP, it produced -0.08 mmHg (95% CI -0.69; 0.54) compared with a mercury sphygmomanometer. There is high heterogeneity between studies (> 90%) in the meta-analysis, partly explained by the device model, study environment, and observer training. Only articles that reported BP measurement by both methods were included.Conclusion: Automatic blood pressure monitors have strong measurement validity when compared with the mercury column. Thus, these can be safely used in blood pressure measurements of children and adolescents in clinical and epidemiological studies. What is Known: •The "gold standard" for indirect BP measurement is the mercury sphygmomanometer. •The accuracy of the automatic device is critical to any blood pressure measurement method. What is New: •Oscillometric or automatic devices can be a suitable alternative to auscultation for initial screening, consistent with current pediatric guidelines. •The automatic devices compared to the mercury column have a good validity of measurements, which can be used in blood pressure measurements of children and adolescents in clinical and epidemiological settings, provided that international protocols are followed.
Topics: Adolescent; Blood Pressure; Blood Pressure Determination; Blood Pressure Monitors; Child; Humans; Hypertension; Mercury; Reproducibility of Results; Sphygmomanometers
PubMed: 34272985
DOI: 10.1007/s00431-021-04171-3 -
Blood Pressure Monitoring Dec 2019A mercury sphygmomanometer has been considered a gold standard for measuring blood pressure. However, by the Minamata Convention on Mercury, the traditional mercury... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
A mercury sphygmomanometer has been considered a gold standard for measuring blood pressure. However, by the Minamata Convention on Mercury, the traditional mercury sphygmomanometer is being replaced by an automated oscillometric device. This study aimed to provide scientific evidence to determine whether an automated oscillometric device can replace a mercury sphygmomanometer and if it is applicable in routine practice.
METHODS
MEDLINE, EMBASE, the Cochrane Library, and CINAHL were searched on 4 May 2018. Studies comparing blood pressure measurements between automated oscillometric devices and mercury sphygmomanometers were included. Study characteristics were abstracted using the evidence table, and random-effects meta-analyses were conducted.
RESULTS
Data were compiled from 24 studies comprising 47 759 subjects. The results of meta-analysis showed that automated oscillometric devices measured lower than mercury sphygmomanometers for both systolic blood pressure (mean differences -1.75 mmHg, 95% confidence intervals: -3.05 to -0.45, I = 91.0%) and diastolic blood pressure (mean differences -1.20 mmHg, 95% confidence intervals: -2.16 to -0.24, I = 95.0%). In sub-group analyses by manufacturer, BpTRU measured lower than the mercury sphygmomanometer and OMRON showed no difference compared to the mercury sphygmomanometer for both systolic and diastolic blood pressure, but the results differed depending on the devices.
CONCLUSION
As a result of this review, the difference in blood pressure between the mercury sphygmomanometer and the automated oscillometric device was within 5 mmHg, but the heterogeneity between the studies was very high. The automated oscillometric devices showed differences in blood pressure results according to the manufacturer and product type.
Topics: Blood Pressure; Blood Pressure Determination; Humans; Hypertension; Mercury; Oscillometry; Reproducibility of Results; Sphygmomanometers
PubMed: 31658107
DOI: 10.1097/MBP.0000000000000412 -
Hypertension (Dallas, Tex. : 1979) Nov 2014Visit-to-visit variability of blood pressure (BP) has been associated with cardiovascular disease (CVD) and mortality in some but not all studies. We conducted a... (Meta-Analysis)
Meta-Analysis Review
Visit-to-visit variability of blood pressure (BP) has been associated with cardiovascular disease (CVD) and mortality in some but not all studies. We conducted a systematic review and meta-analysis to examine the association between visit-to-visit variability of BP and CVD and all-cause mortality. Medical databases were searched through June 4, 2014, for studies meeting the following eligibility criteria: adult participants; BP measurements at ≥3 visits; follow-up for CVD, coronary heart disease, stroke, or mortality outcomes; events confirmed via database, death certificate, or event ascertainment committee; and adjustment for confounders. Data were extracted by 2 reviewers and pooled using a random-effects model. Overall, 8870 abstracts were identified of which 37 studies, representing 41 separate cohorts, met inclusion criteria. Across studies, visit-to-visit variability of systolic BP and diastolic BP showed significant associations with outcomes in 181 of 312 (58.0%) and 61 of 188 (32.4%) analyses, respectively. Few studies provided sufficient data for pooling risk estimates. For each 5 mm Hg higher SD of systolic BP, the pooled hazard ratio for stroke across 7 cohorts was 1.17 (95% confidence interval [CI], 1.07-1.28), for coronary heart disease across 4 cohorts was 1.27 (95% CI, 1.07-1.51), for CVD across 5 cohorts was 1.12 (95% CI, 0.98-1.28), for CVD mortality across 5 cohorts was 1.22 (95% CI, 1.09-1.35), and for all-cause mortality across 4 cohorts was 1.20 (95% CI, 1.05-1.36). In summary, modest associations between visit-to-visit variability of BP and CVD and all-cause mortality are present in published studies. However, these findings are limited by the small amount of data available for meta-analysis.
Topics: Blood Pressure; Blood Pressure Monitors; Cardiovascular Diseases; Coronary Disease; Follow-Up Studies; Humans; Incidence; Mortality; Office Visits; Risk Factors; Stroke; Survival Rate
PubMed: 25069669
DOI: 10.1161/HYPERTENSIONAHA.114.03903 -
Journal of Hypertension Nov 2012The measurement of blood pressure in atrial fibrillation is considered as difficult and uncertain, and current guidelines recommend the use of the auscultatory method.... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
The measurement of blood pressure in atrial fibrillation is considered as difficult and uncertain, and current guidelines recommend the use of the auscultatory method. The accuracy of automated blood pressure monitors in atrial fibrillation remains controversial.
METHOD
A systematic review and meta-analysis was performed of studies comparing automated (oscillometric or automated Korotkov) versus manual auscultatory blood pressure measurements (mercury or aneroid sphygmomanometer) in patients with sustained atrial fibrillation.
RESULTS
Twelve validations were analyzed (566 patients; five home, three ambulatory and three office devices). Pooled correlation coefficients between automated and manual blood pressure measurements were stronger for SBP than DBP (r = 0.89 versus 0.76, P < 0.001). Automated measurements were higher than manual measurements [pooled average SBP difference 0.5 mmHg, 95% confidence interval (CI) -0.9, 1.9; DBP 2.5 mmHg, 95%CI -0.6, 5.7). The mean difference was within 5 mmHg in six and four (SBP and DBP, respectively) of six validations. The SD of mean difference was within 8 mmHg in two and three (SBP and DBP, respectively) of four validations. The proportion of absolute automated-manual differences within 5 mmHg was at least 65% in four and two (SBP and DBP, respectively) of eight validations. Three studies showed no impact of heart rate on the automated-manual blood pressure differences.
CONCLUSION
There is limited evidence and significant heterogeneity in the studies that validated automated blood pressure monitors in atrial fibrillation. These monitors appear to be accurate in measuring SBP but not DBP. Given that atrial fibrillation is common in the elderly, in whom systolic hypertension is more common and important than diastolic hypertension, automated monitors appear to be appropriate for self-home but not for office measurement.
Topics: Analysis of Variance; Atrial Fibrillation; Automation; Blood Pressure Determination; Blood Pressure Monitoring, Ambulatory; Heart Rate; Humans; Hypertension; Reproducibility of Results; Systole
PubMed: 22914573
DOI: 10.1097/HJH.0b013e32835850d7