Clinical and Experimental Dental... Jun 2023Macrophages are among the first cells to interact with the dental implant surface and are critical regulators for controlling the immune response toward biomaterials.... (Review)
Review
A systematic review comparing the macrophage inflammatory response to hydrophobic and hydrophilic sandblasted large grit, acid-etched titanium or titanium-zirconium surfaces during in vitro studies.
OBJECTIVES
Macrophages are among the first cells to interact with the dental implant surface and are critical regulators for controlling the immune response toward biomaterials. Macrophages can polarize between two main phenotypes: proinflammatory M1 macrophages and anti-inflammatory M2 macrophages. This systematic review aims to determine if a differing macrophage inflammatory response exists on hydrophilic sandblasted large grit, acid-etched (SLActive) surfaces compared to sandblasted large grit, acid-etched (SLA) titanium or titanium-zirconium surfaces during in vitro studies. MATERIAL AND METHODS: A systematic search of three electronic databases, Medline, DOSS (Dentistry and Oral Sciences Source), and WoS (Web of Science), was performed. Only in vitro studies were included in this systematic review. The electronic search was supplemented with a search of the references. Genetic expression and production of proinflammatory and anti-inflammatory proteins were assessed. The synthesis of quantitative data was completed by narrative synthesis.
RESULTS
A total of 906 studies were found with the systematic search. Eight studies remained after the application of inclusion and exclusion criteria. Six studies used murine macrophages, while two used human macrophages. Discs were used in six studies, while dental implants were used in the remaining two studies. Genetic expression and cytokine production of proinflammatory cytokines on SLActive surfaces were reduced compared to SLA. Anti-inflammatory genetic expression and cytokine production was increased on SLActive surfaces. The overall quality of the included studies was low to moderate.
CONCLUSIONS
SLActive surfaces modulate macrophages to reduce proinflammatory and increase anti-inflammatory gene expression and cytokine production compared to SLA surfaces. The in vitro nature of the included studies does not replicate the in vivo healing cascade. Further in vivo studies are required to assess the macrophage response toward SLActive implant surfaces compared to SLA surfaces.
Topics: Mice; Humans; Animals; Dental Implants; Titanium; Zirconium; Surface Properties; Macrophages; Cytokines; Anti-Inflammatory Agents
PubMed: 36991526
DOI: 10.1002/cre2.730 -
Journal of Prosthodontics : Official... Oct 2022The purpose of this systematic review and meta-analysis was to evaluate the effect of using additive manufacturing (AM) for dental ceramic fabrication in comparison with... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
The purpose of this systematic review and meta-analysis was to evaluate the effect of using additive manufacturing (AM) for dental ceramic fabrication in comparison with subtractive manufacturing (SM), and to evaluate the effect of the type of AM technology on dental ceramic fabrication.
MATERIALS AND METHODS
A search was conducted electronically in MEDLINE (via PubMed), EBSCOhost, Scopus, and Cochran Library databases, and also by other methods (table of contents screening, backward and forward citations, and grey literature search) up to February 12, 2022, to identify records evaluating additive manufacturing of ceramics for dental purposes in comparison with subtractive manufacturing. A minimum of 2 review authors conducted tstudy selection, quality assessment, and data extraction. Quality assessment was performed with Joanna Briggs Institute tool, and the quantitative synthesis was performed with the Comprehensive Meta-Analysis program (CMA, Biostat Inc). Hedges's g for effect size was calculated, with 0.2 as small, 0.5 as medium, and 0.8 as large. Heterogeneity was assessed with I and prediction interval (PI) statistics. Publication bias was investigated with funnel plots and grey literature search. Certainty of evidence was assessed with the Grading of Recommendations: Assessment, Development, and Evaluation (GRADE) tool.
RESULTS
A total of 28 studies were included for the qualitative and quantitative synthesis; 11 in vitro studies on accuracy, 1 in vivo study on color, and 16 in vitro studies on physical and mechanical properties. Meta-analysis showed overall higher accuracy for SM compared with AM, with medium effect size (0.679, CI: 0.173 to 1.185, p = 0.009) and also for marginal (g = 1.05, CI: 0.344 to 1.760, p = 0.004), occlusal (g = 2.24, CI: 0.718 to 3.766, p = 0.004), and total (g = 4.544, CI: -0.234 to 9.323, p = 0.062) with large effect size; whereas AM had higher accuracy than SM with small effect size for the external (g = -0.238, CI: -1.215 to 0.739), p = 0.633), and internal (g = -0.403, CI: -1.273 to 0.467, p = 0.364) surfaces. For technology, self-glazed zirconia protocol had the smallest effect size (g = -0.049, CI: -0.878 to 0.78, p = 0.907), followed by stereolithography (g = 0.305, CI: -0.289 to 0.9, p = 0.314), and digital light processing (g = 1.819, CI: 0.662 to 2.976, p = 0.002) technologies. Flexural strength was higher for ceramics made by SM in comparison to AM with large effect size (g = -2.868, CI: -4.371 to -1.365, p < 0.001). Only 1 study reported on color, favoring ceramics made through combined AM and SM.
CONCLUSIONS
Subtractive manufacturing had better overall accuracy, particularly for the marginal and occlusal areas, higher flexural strength, and more favorable hardness, fracture toughness, porosity, fatigue, and volumetric shrinkage; whereas AM had more favorable elastic modulus and wettability. Both methods had favorable biocompatibility. All studies on accuracy and mechanical properties were in vitro, with high heterogeneity and low to very low certainty of evidence. There is a lack of studies on color match and esthetics.
Topics: Computer-Aided Design; Esthetics, Dental; Zirconium; Ceramics; Flexural Strength; Stereolithography; Materials Testing; Dental Porcelain; Surface Properties
PubMed: 35675133
DOI: 10.1111/jopr.13553 -
The International Journal of... 2017The aim of this study was to test the null hypothesis that there is no difference in implant failure rates, marginal bone loss, and postoperative infection for implants... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
The aim of this study was to test the null hypothesis that there is no difference in implant failure rates, marginal bone loss, and postoperative infection for implants inserted in bone with different qualities and quantities according to the classification of Lekholm and Zarb.
MATERIALS AND METHODS
An electronic search was undertaken in January 2015 for randomized and nonrandomized human clinical studies.
RESULTS
A total of 94 publications were included. When bone sites of different qualities were considered, the results suggested the following comparative implant failure rates: 1 > 2, 1 > 3, 3 > 2, 4 > 1, 4 > 2, and 4 > 3. Sensitivity analyses suggested that when implants inserted in bone qualities 1 and 2 and 1 and 3 were compared, oxidized and sandblasted/acid-etched surfaces showed a decrease in significant difference in failures compared with turned implants. The same is not true for failure of implants inserted in bone quality 4 compared to failure of implants in all other bone qualities. When bone sites of different quantities were considered, the following comparative implant failure rates were observed: A > B, A > C, A < D, B < C, B < D, C < D, E > A, E > B, E > C, E > D. Due to insufficient information, meta-analyses for the outcomes postoperative infection and marginal bone loss were not performed.
CONCLUSION
Sites with poorer bone quality and lack of bone volume may statistically affect implant failure rates. Implant surfaces may play a role in failure of implants in different bone qualities.
Topics: Alveolar Bone Loss; Bone Transplantation; Dental Implantation, Endosseous; Dental Implants; Dental Restoration Failure; Humans; Peri-Implantitis; Postoperative Complications; Risk Factors; Surgical Wound Infection
PubMed: 28319206
DOI: 10.11607/ijp.5142 -
Journal of Biomedical Materials... Nov 2016This systematic review and meta-analysis evaluated the influence of biological implant surface coatings on periimplant bone formation in comparison to an uncoated... (Meta-Analysis)
Meta-Analysis Review
This systematic review and meta-analysis evaluated the influence of biological implant surface coatings on periimplant bone formation in comparison to an uncoated titanium reference surface in experimental large animal models. The analysis was structured according to the PRISMA criteriae. Of the1077 studies, 30 studies met the inclusion criteriae. Nineteen studies examined the bone implant contact (BIC) and were included in the meta-analysis. Overall, the mean increase in BIC for the test surfaces compared to the reference surfaces was 3.7 percentage points (pp) (95% CI -3.9-11.2, p = 0.339). Analyzing the increase in BIC for specific coated surfaces in comparison to uncoated reference surfaces, inorganic surface coatings showed a significant mean increase in BIC of 14.7 pp (95% CI 10.6-18.9, p < 0.01), extracellular matrix (ECM) surface coatings showed an increase of 10.0 pp (95% CI 4.4-15.6, p < 0.001), and peptide coatings showed a statistical trend with 7.1 pp BIC increase (95% CI -0.8-15.0, p = 0.08). In this review, no statistically significant difference could be found for growth factor surface coatings (observed difference -3.3 pp, 95% CI -16.5-9.9, p = 0.6). All analyses are exploratory in nature. The results show a statistically significant effect of inorganic and ECM coatings on periimplant bone formation. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2898-2910, 2016.
Topics: Animals; Bone Substitutes; Coated Materials, Biocompatible; Implants, Experimental; Intercellular Signaling Peptides and Proteins; Osteogenesis; Surface Properties; Titanium
PubMed: 27301790
DOI: 10.1002/jbm.a.35805 -
American Journal of Infection Control Jan 2021Infectious diseases can be transmitted via fomites (contaminated surfaces/objects); disinfection can interrupt this transmission route. However, disinfection guidelines... (Review)
Review
BACKGROUND
Infectious diseases can be transmitted via fomites (contaminated surfaces/objects); disinfection can interrupt this transmission route. However, disinfection guidelines for low-resource outbreak settings are inconsistent and not evidence-based.
METHODS
A systematic review of surface disinfection efficacy studies was conducted to inform low-resource outbreak guideline development. Due to variation in experimental procedures, outcomes were synthesized in a narrative summary focusing on chlorine-based disinfection against 7 pathogens with potential to produce outbreaks in low-resource settings (Mycobacterium tuberculosis, Vibrio cholerae, Salmonella spp., hepatitis A virus, rotavirus, norovirus, and Ebola virus).
RESULTS
Data were extracted from 89 laboratory studies and made available, including 20 studies on relevant pathogens used in combination with surrogate data to determine minimum target concentration × time ("CT") factors. Stainless steel (68%) and chlorine-based disinfectants (56%) were most commonly tested. No consistent trend was seen in the influence of chlorine concentration and exposure time on disinfection efficacy. Disinfectant application mode; soil load; and surface type were frequently identified as influential factors in included studies.
CONCLUSIONS
This review highlights that surface disinfection efficacy estimates are strongly influenced by each study's experimental conditions. We therefore recommend laboratory testing to be followed by field-based testing/monitoring to ensure effectiveness is achieved in situ.
Topics: Chlorine; Disease Outbreaks; Disinfectants; Disinfection; Humans; Norovirus
PubMed: 32442652
DOI: 10.1016/j.ajic.2020.05.014 -
International Journal of Implant... Feb 2019To review the literature on the effect of dental implant surface roughness in patients with a history of periodontal disease. The present review addresses the following... (Review)
Review
BACKGROUND
To review the literature on the effect of dental implant surface roughness in patients with a history of periodontal disease. The present review addresses the following focus question: Is there a difference for implant survival, mean marginal bone loss, and the incidence of bleeding on probing in periodontally compromised patients receiving a machined dental implant or rough surface dental implant?
METHODS
Electronic and manual literature searches were conducted on PubMed/MEDLINE and the Cochrane Library on studies published until May 2018 to collect information about the effect of machined, moderately rough, and rough dental implant surfaces in patients with a history of periodontal disease. The outcome variables implant survival, mean marginal bone level, and the incidence of peri-implantitis and bleeding on probing were evaluated. Meta-analysis was performed to obtain an accurate estimation of the overall, cumulative results.
RESULTS
Out of 2411 articles, six studies were included in this systematic review. The meta-analysis of the implant survival and implant mean marginal bone loss revealed a risk ratio of 2.92 (CI 95% 0.45, 18.86) for implant failure and a total mean difference of - 0.09 (CI 95% - 0.31, 0.14) for implant mean marginal bone loss measured in a total group of 215 implants, both not statistically significant.
CONCLUSIONS
Due to lack of long-term data (> 5 years), the heterogeneity and variability in study designs and lack of reporting on confounding factors, definitive conclusions on differences in implant survival, and mean marginal bone loss between machined and moderate rough implants in periodontally compromised patients cannot be drawn. Future well-designed long-term randomized controlled trials are necessary to reveal that machined surfaces are superior to moderately rough and rough surfaces in patients with a history of periodontal disease.
PubMed: 30756245
DOI: 10.1186/s40729-019-0156-8 -
Journal of Dental Research Feb 2016Secondary caries lesions are the main late complication of dental restorations, limiting their life span and generating costs by repeated reinterventions. Accurate... (Meta-Analysis)
Meta-Analysis Review
Secondary caries lesions are the main late complication of dental restorations, limiting their life span and generating costs by repeated reinterventions. Accurate detection of secondary lesions is crucial for estimating the true burden of the disease and allocating appropriate treatments. We aimed to assess the accuracy of detection methods for secondary caries lesions. Clinical or in vitro studies were included that investigated the accuracy of 5 detection methods--visual, tactile, radiography, laser fluorescence, quantitative light-induced fluorescence--of natural or artificially induced secondary lesions, as verified against an established reference test. Sensitivity, specificity, positive and negative likelihood ratios, as well as diagnostic odds ratios were calculated and publication bias assessed. From 1,179 screened studies, 23 were included. Most studies were performed in vitro, on permanent posterior teeth, and had high risk of bias or applicability concerns. Lesions were on proximal (14 studies) or other surfaces and adjacent to amalgam (16 studies) or tooth-colored materials. Visual (n = 11), radiographic (n = 13), and laser fluorescence detection (n = 8) had similar sensitivities (0.50 to 0.59) and specificities (0.78 to 0.83), with visual and laser fluorescence assessment being more accurate on nonproximal surfaces and adjacent to composites, respectively. Tactile assessment (n = 7) had low accuracy. Light-induced fluorescence (n = 3) was sensitive on nonproximal surfaces but had low specificities. Most analyses seemed to suffer from publication bias. Despite being a significant clinical and dental public health problem, detection of secondary caries lesions has been assessed by only a few studies with limited validity and applicability. Visual, radiographic and laser-fluorescence detection might be useful to detect secondary lesions. The validity of tactile assessment and quantitative light-induced fluorescence remains unclear at present.
Topics: Dental Caries; Dental Restoration, Permanent; Fluorescence; Humans; Lasers; Physical Examination; Radiography, Bitewing; Recurrence; Reproducibility of Results; Sensitivity and Specificity; Touch; Transillumination; Visual Perception
PubMed: 26464398
DOI: 10.1177/0022034515611041 -
Journal of Dentistry Aug 2015This systematic review aimed at evaluating the accuracy of radiographic caries detection for different lesions at different locations. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
This systematic review aimed at evaluating the accuracy of radiographic caries detection for different lesions at different locations.
DATA
Studies reporting on the accuracy (sensitivity/specificity) of radiographic detection of natural primary caries lesions under clinical or in vitro conditions were included. Risk of bias was assessed using QUADAS-2. Pooled sensitivity, specificity and diagnostic odds ratios (DORs) were calculated using random-effects meta-analysis. Analyses were performed separately for occlusal and proximal lesions, with further discrimination between any kind of lesions, dentine lesions, and cavitated lesions.
SOURCES
Electronic databases (Medline, Embase, Cochrane Central) and grey literature were systematically searched, complemented by cross-referencing from bibliographies.
STUDY SELECTION
From 947 identified articles, 442 were analyzed full-text. 117 studies (13,375 teeth, 19,108 surfaces) were included, the majority of them reporting on permanent teeth and having high risk of bias. The detection of any kind (i.e. also initial) lesions had low sensitivities (pooled DOR [95% CI]: 0.24 [0.21/0.26] to 0.42 [0.31/0.34]), but moderate to high specificities (0.70 [0.76/0.84] to 0.97 [0.95/0.98]). For dentine lesions, sensitivities were higher (from 0.36 [0.24/0.49] for proximal to 0.56 [0.53/0.59] for occlusal lesions), and specificities ranged between 0.87 [0.85/0.89] and 0.95 [0.94/0.96]. No studies reported on cavitated occlusal lesions, whilst for cavitated proximal lesions, sensitivities increased above 0.60, whilst sensitivities remained high (above 0.90).
CONCLUSIONS
Radiographic caries detection is highly accurate for cavitated proximal lesions, and seems also suitable to detect dentine caries lesions. For detecting initial lesions, more sensitive methods could be considered in population with high caries risk and prevalence.
CLINICAL SIGNIFICANCE
Radiographic caries detection is especially suitable for detecting more advanced caries lesions, and has limited risks for false positive diagnoses. For groups with high caries risk and prevalence, alternative detection methods with higher sensitivity for initial lesions might be considered.
Topics: Dental Caries; Humans; Radiography, Dental; Sensitivity and Specificity
PubMed: 25724114
DOI: 10.1016/j.jdent.2015.02.009 -
European Review For Medical and... Nov 2023Early childhood caries is a common condition that poses a serious risk to children's health because it can progress quickly, resulting in pain, abscesses, and a general...
OBJECTIVE
Early childhood caries is a common condition that poses a serious risk to children's health because it can progress quickly, resulting in pain, abscesses, and a general decline in health. As a result, invasive therapies are needed, which call for highly skilled personnel. This systematic review of the literature aims to identify the most recent and widely applied early childhood caries (ECC) prevention and treatment approaches. Only substances that act topically and minimally invasive interventions were considered.
MATERIALS AND METHODS
The database search was restricted to randomized clinical trials completed within the last five years, specifically those that examined the following procedures: sodium fluoride (NaF) varnish, alternative restorative technique (ART), nano-silver fluoride, silver diamine fluoride, and silver modified atraumatic restorative treatment sealants (SMART).
RESULTS
A total of 815 articles were found. After removing duplicates, 584 articles were included, and 567 of them were excluded due to not meeting the predefined inclusion criteria.
CONCLUSIONS
Every method considered has been proven to be successful in halting the progression of ECC and is well-liked by patients, even those who are unwilling to cooperate, as well as by parents. The most common unfavorable effect of SDF is irreversible black discoloration in treated tooth surfaces, but this is typically not a problem. They are all low-cost, minimally invasive techniques that might also be widely used in large communities and low socioeconomic settings.
Topics: Child; Humans; Child, Preschool; Cariostatic Agents; Dental Atraumatic Restorative Treatment; Dental Caries Susceptibility; Sodium Fluoride
PubMed: 38039039
DOI: 10.26355/eurrev_202311_34477 -
Clinical and Experimental Dental... Aug 2022This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces. (Review)
Review
OBJECTIVES
This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces.
MATERIAL AND METHODS
An electronic search for literature was conducted on PubMed, Embase, Scopus, and Web of Science and a total of 14 studies were included. Neutrophil responses were assessed based on adhesion, cell number, surface coverage, cell structure, cytokine secretion, reactive oxygen species (ROS) production, neutrophil activation, receptor expression, and neutrophil extracellular traps (NETs) release. The method of assessing the risk of bias was done using the toxicological data reliability assessment tool (TOXRTOOL).
RESULTS
Ten studies have identified a significant increase in neutrophil functions, such as surface coverage, cell adhesion, ROS production, and NETs released when interacting with rough titanium surfaces. Moreover, neutrophil interaction with rough-hydrophilic surfaces seems to produce less proinflammatory cytokines and ROS when compared to naive smooth and rough titanium surfaces. Regarding membrane receptor expression, two studies have reported that the FcγIII receptor (CD16) is responsible for initial neutrophil adhesion to hydrophilic titanium surfaces. Only one study compared neutrophil interaction with titanium alloy and zirconia toughened alumina surfaces and reported no significant differences in neutrophil cell count, activation, receptor expression, and death.
CONCLUSIONS
There are not enough studies to conclude neutrophil interactions with titanium and zirconia surfaces. However, different topographic modifications such as roughness and hydrophilicity might influence neutrophil interactions with titanium implant surfaces.
Topics: Dental Implants; Neutrophils; Reactive Oxygen Species; Reproducibility of Results; Surface Properties; Titanium; Zirconium
PubMed: 35535662
DOI: 10.1002/cre2.582