The International Journal of Oral &... 2023To evaluate the marginal accuracy of soft-milled cobalt-chromium (Co-Cr) compared to other construction methods/restorative materials in tooth/implant-supported... (Meta-Analysis)
Meta-Analysis
To evaluate the marginal accuracy of soft-milled cobalt-chromium (Co-Cr) compared to other construction methods/restorative materials in tooth/implant-supported restorations. PICO questions were defined, and a systematic search was conducted in six electronic databases. Titles and abstracts were collected and screened by two independent reviewers. After removing duplicate articles, the full texts of relevant articles were gathered, and the required information and data were extracted. Risk of bias was assessed and meta-analyses of the collected data were conducted using STATA software version 16. A total of 1,914 experimental and clinical articles were reviewed, and 18 studies were selected for qualitative analysis. The 16 studies that were included in the meta-analysis showed no significant marginal gap differences between soft-milled Co-Cr and the following methods/materials: hard-milled Co-Cr (I = 92.9%, = .86), casting wax (I = 90.9%, = .42), laser-sintered Co-Cr (I = 93.3%, = .46), and zirconia (I = 0.00%, = .47). However, a significantly higher marginal accuracy of soft-milled Co-Cr was observed when compared to milled-wax casting (I = 93.1%, < .001). The marginal gap of soft-milled Co-Cr restorations is within the acceptable clinical range and provides an accuracy similar to other available methods/materials for both the prepared implant abutment and tooth.
Topics: Chromium Alloys; Dental Materials; Computer-Aided Design; Dental Marginal Adaptation; Dental Prosthesis Design
PubMed: 37099579
DOI: 10.11607/jomi.9782 -
Biomedical Materials (Bristol, England) Apr 2023Guided bone/tissue regeneration (GBR/GTR) is commonly used in dental treatment. The desired bone/tissue regeneration is achieved by placing a barrier membrane over the... (Meta-Analysis)
Meta-Analysis
Guided bone/tissue regeneration (GBR/GTR) is commonly used in dental treatment. The desired bone/tissue regeneration is achieved by placing a barrier membrane over the defect to avoid the downward growth of faster-growing connective and epithelial tissue into the defect. This review aimed to evaluate osteogenic properties, degradation characteristics, and postoperative complications of eight biodegradable membranes in animal experiments, including non-crosslinked collagen membrane (NCCM), crosslinked collagen membrane (CCM), silk membrane (SM), polylactic-co-glycolic acid, polylactic acid, polyethylene glycol hydrogel, polycaprolactone (PCL), and magnesium alloys. Seven electronic databases (PubMed, Embase, Web of Science, Cochrane Library, Science Direct, Wiley, Scopus and Google Scholar) were screened. Study selection, data extraction and quality assessment were made in duplicate. The SYRCLE assessment tool, CERQual (Confidence in the Evidence from Reviews of Qualitative Research) tool and GRADE tool were used to grade the risk of bias and level of evidence. A total of 2512 articles were found in the electronic database. Finally, 94 articles were selected, of which 53 were meta-analyzed. Surface under the cumulative ranking curve showed the best results for new bone formation in the magnesium barrier membrane group, followed by SM, PCL, NCCM, and CCM. Qualitative analysis showed good biocompatibility for natural polymer membranes and a longer degradation time for synthetic polymer membranes. In addition, 34 studies all showed high bias risks, while other studies had unclear bias risks. Natural polymer membranes were more effective for bone regeneration and magnesium alloys were proved to be promising barrier materials that warrant future research.
Topics: Animals; Bone Regeneration; Collagen; Guided Tissue Regeneration; Magnesium; Membranes, Artificial; Network Meta-Analysis; Polymers
PubMed: 37001532
DOI: 10.1088/1748-605X/acc99a -
The Saudi Dental Journal Feb 2023The aim of this systematic review was to present the current knowledge on the influence of laser surface treatment on the adhesion of bacteria to titanium and its alloys. (Review)
Review
OBJECTIVE
The aim of this systematic review was to present the current knowledge on the influence of laser surface treatment on the adhesion of bacteria to titanium and its alloys.
DESIGN
This review was structured according to PRISMA guidelines for systematic reviews and -analyses, and registered on the Open Science Framework platform (https://doi.org/10.17605/OSF.IO/FTA3W). Article searches were performed in 4 databases: PubMed, Scopus, Embase, and Science Direct. In addition, a manual search was performed in the reference lists of the selected articles. The selection of articles was performed by two reviewers. The articles found were screened for eligibility using the previously established inclusion and exclusion criteria. The methodological quality of the studies was assessed using the Joanna Briggs Institute (JBI) Critical Assessment Checklist for Quasi-Experimental Studies (non-randomized experimental studies).
RESULTS
Most of the studies evaluated showed that surface treatment by laser irradiation can affect the adhesion of bacteria to titanium surfaces and that this is directly related to changes in surface properties such as chemical composition, morphology, roughness, and wettability, as well as the type of bacterial species involved.
CONCLUSIONS
The studies considered in this systematic review have shown that surface treatment by laser irradiation is a promising technique to reduce the adhesion of bacteria on the surface of titanium implants.
PubMed: 36942202
DOI: 10.1016/j.sdentj.2023.01.004 -
The Journal of Evidence-based Dental... Mar 2023Delucchi, F.; De Giovanni, E.; Pesce, P.; Bagnasco, F.; Pera, F.; Baldi, D.; Menini, M. Framework Materials for Full-Arch Implant-Supported Rehabilitations: A Systematic...
ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION
Delucchi, F.; De Giovanni, E.; Pesce, P.; Bagnasco, F.; Pera, F.; Baldi, D.; Menini, M. Framework Materials for Full-Arch Implant-Supported Rehabilitations: A Systematic Review of Clinical Studies. Materials 2021, 14, 3251. https:// doi.org/10.3390/ma14123251 SOURCE OF FUNDING: This research received no funding.
TYPE OF STUDY/DESIGN
Systematic Review (SR).
Topics: Humans; Dental Implants; Dental Prosthesis, Implant-Supported; Zirconium
PubMed: 36914295
DOI: 10.1016/j.jebdp.2022.101799 -
Heliyon Mar 2023There is no consensus in the literature about the best non-cytotoxic antibacterial surface treatment for dental implants. Critically evaluate the existing literature and...
There is no consensus in the literature about the best non-cytotoxic antibacterial surface treatment for dental implants. Critically evaluate the existing literature and answer the question: "which surface treatment for dental implants made of titanium and its alloys has the greatest non-cytotoxic antibacterial activity for osteoblastic cells?" This systematic review was registered in the Open Science Framework (osf.io/8fq6p) and followed the Preferred Reporting Items for Systematic Review and Meta-analysis Protocols. The search strategy was applied to four databases. Articles were selected that evaluated in both studies the properties of 1) antibacterial activity and 2) cytotoxicity on osteoblastic cells of titanium and their alloy dental implants when treated superficially. Systematic reviews, book chapters, observational studies, case reports, articles that studied non-dental implants, and articles that evaluated only the development of surface treatment were excluded. The Joanna Briggs Institute, a quasi-experimental study assessment tool, was adapted to assess the risk of bias. The search strategy found 1178 articles in the databases after removing duplicates in EndNote Web, resulting in 1011 articles to be evaluated by title and abstract, of which 21 were selected for full reading, of which 12 were included by eligibility criteria, and nine were excluded. Quantitative synthesis could not be performed due to the heterogeneity of the data (surface treatment, antibacterial assay, bacteria strain, cell viability assay, and cell type). Risk of bias assessment showed that ten studies were classified as low risk and two studies as moderate risk. The evaluated literature allowed us to conclude that: 1) The literature surveyed did not allow answering the question due to the heterogeneity of the studies; 2) Ten of the 12 studies evaluated presented surface treatments with non-cytotoxic antibacterial activity; 3) Adding nanomaterials, QPEI, BG, and CS, reduce the chances of bacterial resistance by controlling their adhesion by electrical forces.
PubMed: 36895374
DOI: 10.1016/j.heliyon.2023.e13693 -
The Journal of Prosthetic Dentistry Mar 2023Providing a removable partial denture (RPD) can be a complex, time-consuming, and error-prone procedure. Computer-aided design and computer-aided manufacturing (CAD-CAM)... (Review)
Review
STATEMENT OF PROBLEM
Providing a removable partial denture (RPD) can be a complex, time-consuming, and error-prone procedure. Computer-aided design and computer-aided manufacturing (CAD-CAM) techniques have shown promising clinical outcomes; however, the influence of manufacturing techniques on the properties of RPD components is unclear.
PURPOSE
The purpose of this systematic review was to determine the accuracy and mechanical properties of RPD components fabricated with conventional and digital methods.
MATERIAL AND METHODS
This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) and was registered on the international prospective register of systematic reviews (PROSPERO) database (CRD42022353993). An electronic search was conducted on PubMed/MEDLINE, Scopus, Web of Science, and the Cochrane Library in August 2022. Only in vitro studies comparing the digital with the lost-wax casting technique were included. The quality of the studies was assessed by using the methodological index for nonrandomized studies (MINORS) scale.
RESULTS
Of the 17 selected studies, 5 evaluated the accuracy of RPD components as well as the mechanical properties, 5 studies evaluated only the component accuracy, and another 7 evaluated only the mechanical properties. The accuracy was similar regardless of the technique, with discrepancies within clinically acceptable values (50 to 426.3 μm). The surface roughness was higher for 3D-printed clasps and lower for milled clasps (P<.05). The metal alloy significantly influenced the porosity, with the highest number of pores obtained by casting for Ti clasps and by rapid prototyping for Co-Cr clasps.
CONCLUSIONS
In vitro studies showed that the digital technique provided similar accuracy to that of the conventional technique within a clinically acceptable range. The manufacturing technique influenced the mechanical properties of RPD components.
PubMed: 36870892
DOI: 10.1016/j.prosdent.2023.01.032 -
Heliyon Dec 2022Critically analyzed the existing literature to answer the question "What is the influence of roughness of surfaces for dental implants obtained by additive manufacturing...
OBJECTIVE
Critically analyzed the existing literature to answer the question "What is the influence of roughness of surfaces for dental implants obtained by additive manufacturing compared to machined on osteoblastic cell adhesion and proliferation?"
DESIGN
This systematic review followed the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and was registered in the Open Science Framework. The personalized search strategy was applied to Embase, Pub Med, Scopus, and Science Direct databases and Google Scholar and ProQuest grey literature. The selection process was carried out in two stages independently by two reviewers according to the eligibility criteria. The risk of bias was analyzed using a checklist of important parameters to be considered.
RESULTS
When applying the search strategy on databases 223 articles were found, after removing the duplicates, 171 were analyzed by title and abstract of which 25 were selected for full reading, of these, 6 met the eligibility criteria. 2 studies were included from the reference list totaling 8 articles included in this systematic review and none were included from the Grey Literature. 7 had a low risk of bias and 1 moderate.
CONCLUSIONS
1) Roughness is a property that must be analyzed and correlated with the chemical composition, intrinsic to the alloy and resulting from the surface treatment; morphology of topographic peaks and valleys; printing technique and its parameters; 2) Need for more studies on the biomolecular level to elucidate the mechanism by which the roughness and the morphology of topographical peaks and valleys descriptive of roughness influence osteoblastic adhesion and proliferation.
PubMed: 36643331
DOI: 10.1016/j.heliyon.2022.e12505 -
The Journal of Prosthetic Dentistry Nov 2022Given the wide use of cobalt-chromium (Co-Cr) alloys, especially for removable partial dentures, and the importance of chemical solutions to complement the cleaning of... (Review)
Review
STATEMENT OF PROBLEM
Given the wide use of cobalt-chromium (Co-Cr) alloys, especially for removable partial dentures, and the importance of chemical solutions to complement the cleaning of dental prostheses, safe disinfection products should be identified for the regular decontamination of Co-Cr dental prostheses.
PURPOSE
The purpose of this systematic review of in vitro studies was to determine the effects on the properties of Co-Cr dental alloys of the various chemical agents used to clean dental prostheses.
MATERIAL AND METHODS
In vitro studies were included based on a literature search conducted in March 2022 in the Medline/PubMed, SCOPUS, Web of Science, Virtual Health Library, and Embase databases. Independent reviewers performed the search, selection, extraction, and analysis of the data. The review was performed based on the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines. The quality of the included articles was evaluated by using parameters adapted from the Consolidated Standards of Reporting Trials (CONSORT) guidelines, and the risk of bias analysis was performed based on previous studies.
RESULTS
Among the 15 included studies, the chemical agents evaluated were alkaline peroxides and hypochlorites, mouthwashes containing cetylpyridinium chloride and chlorhexidine, diluted acids, and enzymes. Some peroxides produced increased ion release, surface roughness, and mass loss of the alloys. The hypochlorites were responsible for the greatest surface corrosion, yielding dark stains, rough regions, and depressions. Acetic and peracetic acids and mouthwashes containing chlorhexidine and cetylpyridinium did not produce significant changes in Co-Cr alloys. Most studies presented moderate risk of bias.
CONCLUSIONS
According to the included studies, mouth rinses containing cetylpyridinium chloride or chlorhexidine and solutions with acetic and peracetic acid could be safely used to chemically sanitize Co-Cr prostheses. Alkaline peroxides should be used with caution, and alkaline hypochlorite solutions should be avoided.
PubMed: 36357193
DOI: 10.1016/j.prosdent.2022.09.013 -
Medicina (Kaunas, Lithuania) Sep 2022The aim of the study was to systematically review the overall outcomes of studies comparing the misfit of yttria-stabilized zirconia (Y-TZP) CAD-CAM implant-supported... (Review)
Review
The aim of the study was to systematically review the overall outcomes of studies comparing the misfit of yttria-stabilized zirconia (Y-TZP) CAD-CAM implant-supported frameworks with frameworks fabricated with other materials and techniques. An electronic literature search of English literature was performed using Google Scholar, Scopus, Web of Science, MEDLINE (OVID), EMBASE, and PubMed, using predetermined inclusion criteria. Specific terms were utilized in conducting a search from the inception of the respective database up to May 2022. After the search strategy was applied, the data were extracted and the results were analyzed. The focused question was: Is the misfit of the implant-supported zirconia CAD-CAM framework lower than that of non-Y-TZP implant-supported fixed restorations? Eleven articles were included for qualitative assessment and critical appraisal in this review. In the included studies, Y-TZP CAD-CAM implant-supported frameworks were compared to Titanium (Ti), Ni-Cr, Co-Cr, PEEK and high-density polymer, and cast and CAD-CAM frameworks. The studies used scanning electron microscopy, one-screw tests, digital or optical microscopy, 3D virtual assessment, and replica techniques for analyzing the misfit of frameworks. Six studies showed comparable misfits among the Y-TZP CAD-CAM frameworks and the controls. Three studies showed higher misfits for the Y-TZP CAD-CAM frameworks, whereas two studies reported lower misfits for Y-TZP CAD-CAM implant frameworks compared to controls. Y-TZP CAD-CAM implant-supported frameworks have comparable misfits to other implant-supported frameworks. However, due to heterogeneity in the methodologies of the included studies, the overall numerical misfit of the frameworks assessed in the reviewed studies is debatable.
Topics: Humans; Titanium; Zirconium; Computer-Aided Design; Polymers
PubMed: 36295507
DOI: 10.3390/medicina58101347 -
The Journal of Prosthetic Dentistry Oct 2022Infections associated with bacterial biofilm formation are an important cause of early implant failure. With the growing number of antibiotic-resistant bacteria, the... (Review)
Review
STATEMENT OF PROBLEM
Infections associated with bacterial biofilm formation are an important cause of early implant failure. With the growing number of antibiotic-resistant bacteria, the incorporation of zinc into TiO coatings of titanium implants has emerged to promote osseointegration and inhibit bacterial proliferation. However, a systematic assessment of its efficacy is lacking.
PURPOSE
The purpose of this systematic review and meta-analysis was to assess the bactericidal effect of zinc-modified TiO coatings on titanium or Ti-6Al-4V alloy.
MATERIAL AND METHODS
The review was structured based on the preferred reporting items for systematic reviews and meta-analyses (PRISMA) checklist and the peer review of electronic search strategies (PRESS) guidelines. The search was performed in Science Direct, SCOPUS, Web of Science, and PubMed databases, including experimental in vitro studies that used titanium or Ti-6Al-4V as a control group and performed bacterial assays. Meta-analysis was performed by using the standardized mean differences of antibacterial effects.
RESULTS
A total of 2519 articles were collected after duplicate removal. Then, eligibility criteria and a manual search were applied to select 20 studies for qualitative analysis and 16 studies for statistical analysis. The risk of bias revealed low-quality evidence. The meta-analysis showed that zinc positively affected the bactericidal activity of TiO coatings (-8.79, CI=-11.01 to -6.57, P<.001), with a high degree of heterogeneity (I=78%). Subgroup analysis with TiO nanotubes produced by anodization and ZnO nanoparticles by hydrothermal synthesis reduced heterogeneity to 43%, with the removal of outliers (I=46%), with a favorable antibacterial effect for zinc incorporation into TiO.
CONCLUSIONS
Bactericidal activity was identified for zinc incorporated into TiO coatings, making it an interesting option for titanium dental implants.
PubMed: 36270807
DOI: 10.1016/j.prosdent.2022.05.007