Frontiers in Bioengineering and... 2022Titanium and alloy osseointegrated implants are used to replace missing teeth; however, some fail and are removed. Modifications of the implant surface with biologically...
Titanium and alloy osseointegrated implants are used to replace missing teeth; however, some fail and are removed. Modifications of the implant surface with biologically active substances have been proposed. MEDLINE [via Pubmed], Embase and Web of Science were searched with the terms "titanium dental implants", "surface properties", "bioactive surface modifications", "biomolecules", "BMP", "antibacterial agent", "peptide", "collagen", "grown factor", "osseointegration", "bone apposition", "osteogenic", "osteogenesis", "new bone formation", "bone to implant contact", "bone regeneration" and " studies", until May 2022. A total of 10,697 references were iden-tified and 26 were included to analyze 1,109 implants, with follow-ups from 2 to 84 weeks. The ARRIVE guidelines and the SYRCLE tool were used to evaluate the methodology and scientific evidence. A meta-analysis was performed (RevMan 2020 software, Cochane Collaboration) with random effects that evaluated BIC at 4 weeks, with subgroups for the different coatings. The heterogeneity of the pooled studies was very high (95% CI, I2 = 99%). The subgroup of BMPs was the most favorable to coating. Surface modification of Ti implants by organic bioactive molecules seems to favor osseointegration in the early stages of healing, but long-term studies are necessary to corroborate the results of the experimental studies.
PubMed: 36225604
DOI: 10.3389/fbioe.2022.986112 -
The Journal of Arthroplasty Feb 2023Wear between the femoral head and acetabular liners continues to limit the longevity of total hip arthroplasty implants despite advances in implant materials. The... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Wear between the femoral head and acetabular liners continues to limit the longevity of total hip arthroplasty implants despite advances in implant materials. The purpose of this meta-analysis was to compare linear wear rates of cobalt-chromium (CoCr) and fourth-generation ceramic femoral heads on highly cross-linked polyethylene (XLPE) liners.
METHODS
A systematic review following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was conducted to identify all studies between 2003 and 2020 that examined in vivo wear rates of either fourth-generation ceramics or CoCr femoral heads on XLPE liners. Studies were analyzed in a weighted means analysis of wear rates and a random effects meta-analysis.
RESULTS
A total of 36 studies met inclusion criteria (1,657 CoCr and 659 ceramic patients). The pooled, weighted mean wear rate was 0.063 mm/year (standard deviation [SD]: 0.061, confidence interval [CI]: 0.049-0.077) for CoCr and 0.047 mm/year (SD: 0.057, CI: 0.033-0.062; P < .01) for ceramic (P < .01). A meta-analysis of 4 studies directly comparing ceramic and CoCr found that CoCr heads demonstrated 0.029 mm/year more wear than ceramic heads (95% CI: 0.026-0.059, P = .306). Mean wear for 32-mm heads was significantly higher for ceramic (P < .01), while mean wear for 36-mm heads was significantly higher for CoCr (P < .01).
CONCLUSION
Fourth-generation ceramic femoral heads were found to have significantly lower wear rates than CoCr heads. Unlike previous studies, this meta-analysis included only in vivo studies and those with the same generation of highly XLPE liners.
Topics: Humans; Femur Head; Prosthesis Design; Arthroplasty, Replacement, Hip; Hip Prosthesis; Polyethylene; Chromium Alloys; Ceramics; Prosthesis Failure; Cobalt
PubMed: 36108994
DOI: 10.1016/j.arth.2022.09.008 -
Materials (Basel, Switzerland) Aug 2022The toxicological risk of Co-Cr dental alloys is actually a sensitive subject with the European regulatory changes, namely regulation (EU) 2017/745 and annex VI to the... (Review)
Review
The toxicological risk of Co-Cr dental alloys is actually a sensitive subject with the European regulatory changes, namely regulation (EU) 2017/745 and annex VI to the CLP regulation (EC) 1972/2008. : The objective of this review is to conduct a rigorous analysis of the cytocompatibility of cobalt-chromium (Co-Cr) dental alloys. Considering various parameters such as cytotoxicity, type IV hypersensitivity reaction, sensitization, and irritation, we investigated evidence of toxicity of Co-Cr in human dental applications. : Specific search strategies were performed in three electronic databases, namely , , and , using a main restriction in the search regarding the publication date (1995-2022). : Out of a total of 836 articles, only 21 studies were selected and analyzed according to PRISMA methodology. : Among them, 10 in vitro studies using human samples and 11 in vivo studies on human patients were distinguished. Most of the in vitro studies confirmed that Co-Cr alloys have a good cytocompatibility compared to Ni alloys. Regarding the in vivo studies, it appeared that Co-Cr could rarely cause sensitization, irritation, and allergic reactions. Reactions were mainly observed for people allergic to Co or Cr. Nevertheless, titanium-based materials showed better results. : This study proposes a new state of the art on Co-Cr dental alloys and will thus be very useful for carrying out additional studies. : This review will help practitioners in their daily clinical choice.
PubMed: 36079183
DOI: 10.3390/ma15175801 -
International Journal of Dentistry 2022The objective of this work is to study galvanic corrosion of different couples of prosthetic and implant alloys through the realization of a systematic review. (Review)
Review
PURPOSE
The objective of this work is to study galvanic corrosion of different couples of prosthetic and implant alloys through the realization of a systematic review.
MATERIALS AND METHODS
An electronic search was performed on Pubmed, Google Scholar, Scopus, ScienceDirect, EbscoHost, and Web of Science for published studies related to electrogalvanism in oral implantology. The keywords used were "dental implants" and "galvanic corrosion." Two independent readers read the scientific articles.
RESULTS
From 65 articles initially identified, only 19 articles met the eligibility criteria. The evaluation of the selected articles allowed us to determine the parameters compared, such as the resistance to galvanic corrosion, the influence of fluorine and pH on the electrochemical behavior, and the release of metal ions and their cytotoxicity. Indeed, Ti6Al4V and precious alloys coupled to titanium were found to be the most resistant to galvanic corrosion, followed by cobalt-chromium alloys and nickel-chromium alloys which were least resistant. This resistance decreases with increasing fluorine concentration and with decreasing pH of the environment. . The implant-prosthetic system's galvanic resistance is influenced by many intrinsic factors: alloy composition and surface condition, as well as extrinsic factors such as pH variations and amount of fluorine. The effects of oral electrogalvanism are essentially the result of two main criteria: effects due to electric currents generated by corrosion and effects due to the release of metal ions by corrosion.
CONCLUSION
To avoid this phenomenon, it is wise to follow the proposed recommendations such as the use of the minimum of distinct metals as much as possible, favoring the commercially pure titanium implant of Ti6Al4V, opting for the choice of couples, titanium/titanium, favoring daily mouthwashes of 227 ppm of fluoride, and avoiding fluorinated acid solutions.
PubMed: 36034476
DOI: 10.1155/2022/4575416 -
The International Journal of Oral &... 2022This review aimed to summarize the current literature on the oral biofilm formation on alternative abutment materials compared with titanium (Ti) or Ti alloy in clinical...
PURPOSE
This review aimed to summarize the current literature on the oral biofilm formation on alternative abutment materials compared with titanium (Ti) or Ti alloy in clinical and in situ conditions.
MATERIALS AND METHODS
An electronic database search was conducted in PubMed, Cochrane Library, EMBASE, Scopus, Web of Science, LIVIVO, BVS, ProQuest, and OpenGrey up to November 2020. Clinical and in situ studies evaluating the biofilm formed on metallic, ceramic, or polymeric abutment materials compared with Ti or Ti alloy were included. Outcome measures were microbial counts/profile, cell viability, and biofilm coverage/thickness. Clinical parameters were deemed secondary outcomes. Risk of bias was assessed by RoB 2 and ROBINS-I tools.
RESULTS
A total of 10 clinical and 9 in situ studies were included. Meta-analysis was not performed due to heterogeneity across studies. The abutment materials polytetrafluoroethylene, gold alloy, gold-platinum alloy, cobalt-chromium, alumina, and zirconia were reported. Six out of ten clinical studies (60%) and four out of nine in situ studies (44%) found no qualitative or quantitative microbiologic differences between tested materials. When significant differences were detected, conflicting results were reported. Clinical outcomes were consistent with healthy conditions for all investigated materials.
CONCLUSION
There is not enough evidence to support the existence of relevant microbiologic differences in the biofilm formed on alternative abutment materials over Ti and its alloys in oral conditions. No evident relationship between microbiologic results and clinical outcomes were found. In situ studies and polymicrobial analyses showed a higher tendency to find significant differences between materials.
Topics: Alloys; Biofilms; Dental Abutments; Dental Implants; Dental Materials; Titanium; Zirconium
PubMed: 35904820
DOI: 10.11607/jomi.9352 -
Spine Deformity Nov 2022To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery.
METHODS
A systematic literature review and meta-analysis evaluated ASD surgery using pedicle screw fixation systems with rods of different materials and sizes. Postoperative outcomes (i.e., Cobb, sagittal vertical axis, and pelvic tilt angle) and complications (i.e., pseudarthrosis and rod breakage) were assessed. Random effects models (REMs) pooled data for outcomes reported in ≥ 2 studies.
RESULTS
Among 50 studies evaluating ASD surgery using pedicle screw fixation systems, 17 described rod material/diameter. Postoperative outcomes did not statistically differ between cobalt-chromium (CoCr) vs. titanium (Ti) rods (n = 2 studies; mean [95% confidence interval (CI)] sagittal vertical axis angle: CoCr 37.00° [18.58°-55.42°] and Ti 32.58° [24.62°-40.54°]; mean [95% CI] pelvic tilt angle: CoCr 26.20° [22.87°-29.53°] and Ti 20.15° [18.0°-22.31°]). The pooled proportion (95% CI) of pseudarthrosis was 15% (7-22%) for CoCr and 12% (- 8-32%) for stainless steel (SS) (n = 2 studies each; Chi = 0.07, p = 0.79). The pooled proportion (95% CI) of broken rods was 12% (1-22%) for Ti (n = 3 studies) and 10% (2-19) for CoCr (n = 1 study). Among 6.0-6.35 mm rods, the pooled (95% CI) postoperative Cobb angle (n = 2) was 12.01° (9.75°-14.28°), sagittal vertical axis angle (n = 4) was 35.32° (30.02°-40.62°), and pelvic tilt angle was 21.11° (18.35°-23.86°).
CONCLUSIONS
For ASD patients undergoing posterior fixation and fusion, there are no statistically significant differences in postoperative outcomes or complications among rods of varying materials and diameters. Benchmark postsurgical outcomes and complication rates by rod material and diameter are provided.
LEVEL OF EVIDENCE
III.
Topics: Adult; Humans; Spinal Fusion; Stainless Steel; Titanium; Chromium Alloys; Pseudarthrosis; Cobalt; Chromium
PubMed: 35904725
DOI: 10.1007/s43390-022-00556-y -
The Saudi Dental Journal Jul 2022A critical analysis of the existing literature to answer "What is the influence of electrical charge of titanium alloys in the electrical interaction with osteoblastic... (Review)
Review
OBJECTIVE
A critical analysis of the existing literature to answer "What is the influence of electrical charge of titanium alloys in the electrical interaction with osteoblastic cells for osseointegration?".
DESIGN
This systematic review followed PRISMA. The personalized search strategy was applied in PubMed, Science Direct, Embase, and Scopus databases, furthermore, in the grey literature in the Google Scholar and ProQuest. The selection process was carried out in two stages independently by two reviewers according to the eligibility criteria. The risk of bias was also analyzed.
RESULTS
When applying the search strategy, 306 articles were found, after removing duplicates 277 were analyzed by title and abstract, of which 33 were selected for full reading, of which 10 met the eligibility criteria. And one was included from the additional literature search. Of these, all had a low risk of bias.
CONCLUSIONS
1. The phenomenon of osseointegration is complex and, independent of the superficial electrical charge of the implant, it may occur. To understand osseointegration, attention must be paid to the synergistic action of the electrical potential; chemical composition, intrinsic to the alloy and from surface treatment; and topography, which will determine the speed of adhesion, proliferation, and osteoblast differentiation. 2. The presence of Ca2+ deposited on the surface acts as a driving force for biomineralization that induces osteoblastic attraction and differentiation; 3. For a better understanding of the current literature, more studies are needed to describe the osteogenic regulation process through protein mediation; 4. Topography and chemical composition act as decisive parameters for cell viability independent of the attractive electrical charge.
PubMed: 35814840
DOI: 10.1016/j.sdentj.2022.04.003 -
Dentistry Journal May 2022: Dental implant therapy is currently identified as the most effective treatment for edentulous patient. However, peri-implant inflammations were found to be one of the... (Review)
Review
: Dental implant therapy is currently identified as the most effective treatment for edentulous patient. However, peri-implant inflammations were found to be one of the most common complications that leads to the loss and failure of dental implantation. Ultraviolet (UV) radiation has been proposed to enhance bone integration and reduce bacterial attachment. In this study, we aimed to systematically review the current evidence regarding the antimicrobial effect of UV on different dental implant surfaces. Five databases including PubMed, Scopus, Web of science, VHL, and Cochran Library were searched to retrieve relevant articles. All original reports that examined the effect of the application of UV radiation on dental implants were included in our study. A total of 16 in vitro studies were included in this systematic review. Polymethyl methacrylate UV radiation has induced a significant decrease in bacterial survival in PMMA materials, with an increased effect by modification with 2.5% and 5% TiO nanotubes. UV-C showed a superior effect to UV-A in reducing bacterial attachment and accumulation. UV wavelength of 265 and 285 nm showed powerful bactericidal effects. UV of 365 nm for 24 h had the highest inhibition of bacterial growth in ZnO coated magnesium alloys. In UV-irradiated commercially pure titanium surfaces treated with plasma electrolytic oxidation, silver ion application, heat or alkali had shown significant higher bactericidal effect vs non-irradiated treated surfaces than the treatment with any of them alone. UVC and gamma-ray irradiation increased the hydrophilicity of zirconia surface, compared to the dry heat. UV radiation on Ti surfaces exhibited significant antibacterial effects demonstrated through the reduction in bacterial attachment and biofilm formation with suppression of bacterial cells growth. Combination of UV and treated surfaces with alkali, plasma electrolytic oxidation, silver ion application or heat enhance the overall photocatalytic antimicrobial effect.
PubMed: 35735635
DOI: 10.3390/dj10060093 -
Clinical and Experimental Dental... Aug 2022This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces. (Review)
Review
OBJECTIVES
This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces.
MATERIAL AND METHODS
An electronic search for literature was conducted on PubMed, Embase, Scopus, and Web of Science and a total of 14 studies were included. Neutrophil responses were assessed based on adhesion, cell number, surface coverage, cell structure, cytokine secretion, reactive oxygen species (ROS) production, neutrophil activation, receptor expression, and neutrophil extracellular traps (NETs) release. The method of assessing the risk of bias was done using the toxicological data reliability assessment tool (TOXRTOOL).
RESULTS
Ten studies have identified a significant increase in neutrophil functions, such as surface coverage, cell adhesion, ROS production, and NETs released when interacting with rough titanium surfaces. Moreover, neutrophil interaction with rough-hydrophilic surfaces seems to produce less proinflammatory cytokines and ROS when compared to naive smooth and rough titanium surfaces. Regarding membrane receptor expression, two studies have reported that the FcγIII receptor (CD16) is responsible for initial neutrophil adhesion to hydrophilic titanium surfaces. Only one study compared neutrophil interaction with titanium alloy and zirconia toughened alumina surfaces and reported no significant differences in neutrophil cell count, activation, receptor expression, and death.
CONCLUSIONS
There are not enough studies to conclude neutrophil interactions with titanium and zirconia surfaces. However, different topographic modifications such as roughness and hydrophilicity might influence neutrophil interactions with titanium implant surfaces.
Topics: Dental Implants; Neutrophils; Reactive Oxygen Species; Reproducibility of Results; Surface Properties; Titanium; Zirconium
PubMed: 35535662
DOI: 10.1002/cre2.582 -
Journal of Prosthodontics : Official... Feb 2023To perform a systematic review that provides an overview of the current literature on fatigue behavior of removable partial denture (RPD) clasp materials based on... (Review)
Review
PURPOSE
To perform a systematic review that provides an overview of the current literature on fatigue behavior of removable partial denture (RPD) clasp materials based on different retentive areas.
MATERIALS AND METHODS
The review followed the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines. Electronic searches were done via PubMed, Scopus, and OVID for studies reporting on RPD clasps and the fatigue failure of clasp materials. Inclusion criteria were English language with full text and in vitro studies only. Exclusion criteria were studies that did not assess the fatigue of RPD clasp materials. A quality assessment and selection of full-text articles were performed according to Consolidated Standards of Reporting Trials criteria.
RESULTS
A total of 182 articles were initially identified and screened. After applying inclusion and exclusion criteria, 15 articles were selected for the final analysis. Seven of the included studies utilized a vertical insertion/removal testing approach. Ten studies used the constant deflection test. Three studies used untapered specimens, and 12 studies used tapered specimens. Ten studies performed post-test analysis.
CONCLUSIONS
Cobalt-chromium (CoCr) is the strongest material in terms of fatigue in relation to the undercut depth and the modern, digitally manufactured RPD clasp materials also exhibit comparable fatigue behavior. Recent RPD clasp materials such as polyetheretherketone (PEEK) or laser sintered CoCr, however, require further study in terms of their fatigue behavior. In order to improve the quality of future studies, a standardized and calibrated fatigue testing method is needed with standardized specimen size and shape, which will reduce the risk of bias and enable meta-analysis for bulk comparison between studies.
Topics: Chromium Alloys; Dental Clasps; Denture Retention; Denture, Partial, Removable; Materials Testing
PubMed: 35405767
DOI: 10.1111/jopr.13519