-
Scientific Reports Apr 2024Optical coherence tomography angiography (OCTA) is widely used for non-invasive retinal vascular imaging, but the OCTA methods used to assess retinal perfusion vary. We... (Meta-Analysis)
Meta-Analysis
Optical coherence tomography angiography (OCTA) is widely used for non-invasive retinal vascular imaging, but the OCTA methods used to assess retinal perfusion vary. We evaluated the different methods used to assess retinal perfusion between OCTA studies. MEDLINE and Embase were searched from 2014 to August 2021. We included prospective studies including ≥ 50 participants using OCTA to assess retinal perfusion in either global retinal or systemic disorders. Risk of bias was assessed using the National Institute of Health quality assessment tool for observational cohort and cross-sectional studies. Heterogeneity of data was assessed by Q statistics, Chi-square test, and I index. Of the 5974 studies identified, 191 studies were included in this evaluation. The selected studies employed seven OCTA devices, six macula volume dimensions, four macula subregions, nine perfusion analyses, and five vessel layer definitions, totalling 197 distinct methods of assessing macula perfusion and over 7000 possible combinations. Meta-analysis was performed on 88 studies reporting vessel density and foveal avascular zone area, showing lower retinal perfusion in patients with diabetes mellitus than in healthy controls, but with high heterogeneity. Heterogeneity was lowest and reported vascular effects strongest in superficial capillary plexus assessments. Systematic review of OCTA studies revealed massive heterogeneity in the methods employed to assess retinal perfusion, supporting calls for standardisation of methodology.
Topics: Tomography, Optical Coherence; Humans; Retinal Vessels; Fluorescein Angiography; Angiography
PubMed: 38670997
DOI: 10.1038/s41598-024-54306-3 -
Spinal Cord Series and Cases Apr 2024Systematic review.
STUDY DESIGN
Systematic review.
OBJECTIVE
Contrast-enhanced ultrasound (CEUS) is an imaging modality that has only recently seen neurosurgical application. CEUS uses inert microbubbles to intraoperatively visualize vasculature and perfusion of the brain and spinal cord in real time. Observation and augmentation of spinal cord perfusion is vital component of the management of traumatic spinal cord injury, yet there are limited imaging modalities to evaluate spinal cord perfusion. CEUS provides an intraoperative imaging tool to evaluate spinal cord perfusion in real time. The objective of this review is to evaluate the current literature on the various applications and benefits of CEUS in traumatic spinal cord injury.
SETTING
South Carolina, USA.
METHODS
This review was written according to the PRISMA 2020 guidelines.
RESULTS
143 articles were found in our literature search, with 46 of them being unique. After excluding articles for relevance to CEUS and spinal cord injury, we were left with 10 papers. Studies in animal models have shown CEUS to be an effective non-invasive imaging modality that can detect perfusion changes of injured spinal cords in real time.
CONCLUSION
This imaging modality can provide object perfusion data of the nidus of injury, surrounding penumbra and healthy neural tissue in a traumatized spinal cord. Investigation in its use in humans is ongoing and remains promising to be an effective diagnostic and prognostic tool for those suffering from spinal cord injury.
Topics: Spinal Cord Injuries; Humans; Ultrasonography; Contrast Media; Animals; Spinal Cord
PubMed: 38664470
DOI: 10.1038/s41394-024-00644-3 -
European Journal of Surgical Oncology :... Apr 2024The neuro-surgical community is witnessing a rising interest for surgical application of multispectral/hyperspectral imaging. Several potential technical applications of... (Review)
Review
INTRODUCTION
The neuro-surgical community is witnessing a rising interest for surgical application of multispectral/hyperspectral imaging. Several potential technical applications of this optical imaging are reported, but the set-up is variable and so are the processing methods. We present a systematic review of the relevant literature on the topic.
MATERIALS AND METHODS
A literature search based on the PRISMA principles was performed on PubMed, SCOPUS, and Web of Science, using MESH terms and Boolean operators. Papers regarding intra-operative in-vivo application of multispectral and/or hyperspectral imaging in humans during neurosurgical procedures were included. Papers reporting technologies related to radiological applications were excluded. A meta-analysis on the performance metrics was also conducted.
RESULTS
Our search string retrieved 20 papers. The main applications of optical imaging during neurosurgery concern tumour detection and improvement of the extent of resection (15 papers) or visualization of perfusion changes during neuro-oncology or neuro-vascular surgery (5 papers). All the retrieved articles were pilot studies, proof of concepts, or case reports, with limited number of patients recruited. Sensitivity, specificity, and accuracy were promising in most of the reports, but the metanalysis showed heterogeneous approaches and results among studies.
CONCLUSIONS
The present review shows that several approaches are currently being tested to integrate hyperspectral imaging in neurosurgery, but most of the studies reported a limited pool of patients, with different approaches to data collection and analysis. Further studies on larger cohorts of patients are therefore desirable to fully explore the potential of this imaging technique.
PubMed: 38658267
DOI: 10.1016/j.ejso.2024.108293 -
Journal of Medical Economics 2024This systematic literature review (SLR) consolidated economic and healthcare resource utilization (HCRU) evidence for positron emission tomography (PET) and...
Economic and healthcare resource utilization assessments of PET imaging in Coronary Artery Disease diagnosis: a systematic review and discussion of opportunities for future economic evaluations.
AIMS
This systematic literature review (SLR) consolidated economic and healthcare resource utilization (HCRU) evidence for positron emission tomography (PET) and single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) to inform future economic evaluations.
MATERIALS AND METHODS
An electronic search was conducted in MEDLINE, Embase, and Cochrane databases from 2012-2022. Economic and HCRU studies in adults who underwent PET- or SPECT-MPI for coronary artery disease (CAD) diagnosis were eligible. A qualitative methodological assessment of existing economic evaluations, HCRU, and downstream cardiac outcomes was completed. Exploratory meta-analyses of clinical outcomes were performed.
RESULTS
The search yielded 13,439 results, with 71 records included. Economic evaluations and comparative clinical trials were limited in number and outcome types (HCRU, downstream cardiac outcomes, and diagnostic performance) assessed. No studies included all outcome types and only one economic evaluation linked diagnostic performance to HCRU. The meta-analyses of comparative studies demonstrated significantly higher rates of early- and late-invasive coronary angiography and revascularization for PET- compared to SPECT-MPI; however, the rate of repeat testing was lower with PET-MPI. The rate of acute myocardial infarction was lower, albeit non-significant with PET- vs. SPECT-MPI.
LIMITATIONS AND CONCLUSIONS
This SLR identified economic and HCRU evaluations following PET- and SPECT-MPI for CAD diagnosis and determined that existing studies do not capture all pertinent outcome parameters or link diagnostic performance to downstream HCRU and cardiac outcomes, thus, resulting in simplified assessments of CAD burden. A limitation of this work relates to heterogeneity in study designs, patient populations, and follow-up times of existing studies. Resultingly, it was challenging to pool data in meta-analyses. Overall, this work provides a foundation for the development of comprehensive economic models for PET- and SPECT-MPI in CAD diagnosis, which should link diagnostic outcomes to HCRU and downstream cardiac events to capture the full CAD scope.
Topics: Humans; Coronary Artery Disease; Positron-Emission Tomography; Tomography, Emission-Computed, Single-Photon; Cost-Benefit Analysis; Myocardial Perfusion Imaging; Patient Acceptance of Health Care
PubMed: 38650543
DOI: 10.1080/13696998.2024.2345507 -
Perfusion Apr 2024Most cardiac surgery clinical prediction models (CPMs) are developed using pre-operative variables to predict post-operative outcomes. Some CPMs are developed with... (Review)
Review
BACKGROUND
Most cardiac surgery clinical prediction models (CPMs) are developed using pre-operative variables to predict post-operative outcomes. Some CPMs are developed with intra-operative variables, but none are widely used. The objective of this systematic review was to identify CPMs with intra-operative variables that predict short-term outcomes following adult cardiac surgery.
METHODS
Ovid MEDLINE and EMBASE databases were searched from inception to December 2022, for studies developing a CPM with at least one intra-operative variable. Data were extracted using a critical appraisal framework and bias assessment tool. Model performance was analysed using discrimination and calibration measures.
RESULTS
A total of 24 models were identified. Frequent predicted outcomes were acute kidney injury (9/24 studies) and peri-operative mortality (6/24 studies). Frequent pre-operative variables were age (18/24 studies) and creatinine/eGFR (18/24 studies). Common intra-operative variables were cardiopulmonary bypass time (16/24 studies) and transfusion (13/24 studies). Model discrimination was acceptable for all internally validated models (AUC 0.69-0.91). Calibration was poor (15/24 studies) or unreported (8/24 studies). Most CPMs were at a high or indeterminate risk of bias (23/24 models). The added value of intra-operative variables was assessed in six studies with statistically significantly improved discrimination demonstrated in two.
CONCLUSION
Weak reporting and methodological limitations may restrict wider applicability and adoption of existing CPMs that include intra-operative variables. There is some evidence that CPM discrimination is improved with the addition of intra-operative variables. Further work is required to understand the role of intra-operative CPMs in the management of cardiac surgery patients.
PubMed: 38649154
DOI: 10.1177/02676591241237758 -
European Radiology Apr 2024To evaluate the diagnostic performance of quantitative magnetic resonance (MR) imaging biomarkers in distinguishing between inflammatory pancreatic masses (IPM) and... (Review)
Review
OBJECTIVES
To evaluate the diagnostic performance of quantitative magnetic resonance (MR) imaging biomarkers in distinguishing between inflammatory pancreatic masses (IPM) and pancreatic cancer (PC).
METHODS
A literature search was conducted using PubMed, Embase, the Cochrane Library, and Web of Science through August 2023. Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to evaluate the risk of bias and applicability of the studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated using the DerSimonian-Laird method. Univariate meta-regression analysis was used to identify the potential factors of heterogeneity.
RESULTS
Twenty-four studies were included in this meta-analysis. The two main types of IPM, mass-forming pancreatitis (MFP) and autoimmune pancreatitis (AIP), differ in their apparent diffusion coefficient (ADC) values. Compared with PC, the ADC value was higher in MFP but lower in AIP. The pooled sensitivity/specificity of ADC were 0.80/0.85 for distinguishing MFP from PC and 0.82/0.84 for distinguishing AIP from PC. The pooled sensitivity/specificity for the maximal diameter of the upstream main pancreatic duct (dMPD) was 0.86/0.74, with a cutoff of dMPD ≤ 4 mm, and 0.97/0.52, with a cutoff of dMPD ≤ 5 mm. The pooled sensitivity/specificity for perfusion fraction (f) was 0.82/0.68, and 0.82/0.77 for mass stiffness values.
CONCLUSIONS
Quantitative MR imaging biomarkers are useful in distinguishing between IPM and PC. ADC values differ between MFP and AIP, and they should be separated for consideration in future studies.
CLINICAL RELEVANCE STATEMENT
Quantitative MR parameters could serve as non-invasive imaging biomarkers for differentiating malignant pancreatic neoplasms from inflammatory masses of the pancreas, and hence help to avoid unnecessary surgery.
KEY POINTS
• Several quantitative MR imaging biomarkers performed well in differential diagnosis between inflammatory pancreatic mass and pancreatic cancer. • The ADC value could discern pancreatic cancer from mass-forming pancreatitis or autoimmune pancreatitis, if the two inflammatory mass types are not combined. • The diameter of main pancreatic duct had the highest specificity for differentiating autoimmune pancreatitis from pancreatic cancer.
PubMed: 38639911
DOI: 10.1007/s00330-024-10720-9 -
The British Journal of Surgery Apr 2024Machine perfusion is an organ preservation strategy used to improve function over simple storage in a cold environment. This article presents an updated systematic... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Machine perfusion is an organ preservation strategy used to improve function over simple storage in a cold environment. This article presents an updated systematic review and meta-analysis of machine perfusion in deceased donor kidneys.
METHODS
RCTs from November 2018 to July 2023 comparing machine perfusion versus static cold storage in kidney transplantation were evaluated for systematic review. The primary outcome in meta-analysis was delayed graft function.
RESULTS
A total 19 studies were included, and 16 comparing hypothermic machine perfusion with static cold storage were analysed. The risk of delayed graft function was lower with hypothermic machine perfusion (risk ratio (RR) 0.77, 95% c.i. 0.69 to 0.86), even in kidneys after circulatory death (RR 0.78, 0.68 to 0.90) or brain death (RR 0.73, 0.63 to 0.84). Full hypothermic machine perfusion decreased the risk of delayed graft function (RR 0.69, 0.60 to 0.79), whereas partial hypothermic machine perfusion did not (RR 0.92, 0.69 to 1.22). Normothermic machine perfusion or short-term oxygenated hypothermic machine perfusion preservation after static cold storage was equivalent to static cold storage in terms of delayed graft function and 1-year graft survival.
CONCLUSION
Hypothermic machine perfusion reduces delayed graft function risks and normothermic approaches show promise.
Topics: Humans; Delayed Graft Function; Graft Survival; Kidney; Kidney Transplantation; Organ Preservation; Perfusion; Randomized Controlled Trials as Topic
PubMed: 38637312
DOI: 10.1093/bjs/znae102 -
International Journal of Radiation... Apr 2024Our purpose was to provide an understanding of current functional lung imaging (FLI) techniques and their potential to improve dosimetry and outcomes for patients with... (Review)
Review
Our purpose was to provide an understanding of current functional lung imaging (FLI) techniques and their potential to improve dosimetry and outcomes for patients with lung cancer receiving radiation therapy (RT). Excerpta Medica dataBASE (EMBASE), PubMed, and Cochrane Library were searched from 1990 until April 2023. Articles were included if they reported on FLI in one of: techniques, incorporation into RT planning for lung cancer, or quantification of RT-related outcomes for patients with lung cancer. Studies involving all RT modalities, including stereotactic body RT and particle therapy, were included. Meta-analyses were conducted to investigate differences in dose-function parameters between anatomic and functional RT planning techniques, as well as to investigate correlations of dose-function parameters with grade 2+ radiation pneumonitis (RP). One hundred seventy-eight studies were included in the narrative synthesis. We report on FLI modalities, dose-response quantification, functional lung (FL) definitions, FL avoidance techniques, and correlations between FL irradiation and toxicity. Meta-analysis results show that FL avoidance planning gives statistically significant absolute reductions of 3.22% to the fraction of well-ventilated lung receiving 20 Gy or more, 3.52% to the fraction of well-perfused lung receiving 20 Gy or more, 1.3 Gy to the mean dose to the well-ventilated lung, and 2.41 Gy to the mean dose to the well-perfused lung. Increases in the threshold value for defining FL are associated with decreases in functional parameters. For intensity modulated RT and volumetric modulated arc therapy, avoidance planning results in a 13% rate of grade 2+ RP, which is reduced compared with results from conventional planning cohorts. A trend of increased predictive ability for grade 2+ RP was seen in models using FL information but was not statistically significant. FLI shows promise as a method to spare FL during thoracic RT, but interventional trials related to FL avoidance planning are sparse. Such trials are critical to understanding the effect of FL avoidance planning on toxicity reduction and patient outcomes.
PubMed: 38631538
DOI: 10.1016/j.ijrobp.2024.04.001 -
Reproductive Biology and Endocrinology... Apr 2024Intra-uterine infusion treatments were reported to be beneficial to embryo implantation and pregnancy outcomes, and considered as potential therapies for infertile... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Intra-uterine infusion treatments were reported to be beneficial to embryo implantation and pregnancy outcomes, and considered as potential therapies for infertile patients with recurrent implantation failure (RIF). Nevertheless, their efficiencies were controversial and there lack of consensus on which intrauterine treatment is the most effective.
METHODS
All prospective trials (in Chinese or English) were searched in Databases PubMed, Cochrane, Web of Science, and CNKI from July 2013 to July 2023. We included studies that investigated various uterine infusions, including chorionic gonadotropin, granulocyte colony-stimulating factor, monocytes, platelet-rich plasma, etc. during IVF treatment and reported subsequent pregnancy outcomes.
RESULTS
We finally included 56 researches, including 40 randomized controlled trials, 14 non-randomized controlled trials, and 3 prospective cohort studies. This study included a total of 11 uterine perfusion methods: Placebo, Human Chorionic Gonadotropin (HCG), Granulocyte Colony-Stimulating Factor (G-CSF), platelet-rich plasma (PRP), Peripheral Blood Mononuclear Cell (PBMC), Growth hormone (GH), dexamethasone (DEX), Embryo culture supernatant (ESC), PRP combined with G-CSF (PRP + G-CSF), RPR combined with subcutaneous injection of G-CSF (RPR + G-CSFsc), G-CSF combined with subcutaneous injection of AXaIU (G-CSF + AXaIUsc). Intrauterine infusion of HCG, PBMC, G-CSF, and PRP significantly improves pregnancy outcomes in patients with repeated implantation failure compared with blank controls or placebo, and PRP improved the clinical pregnancy and live birth most. GH and ESC infusion might improve the pregnancy outcomes, but uterine infusion of DEX was shown with high miscarriage. The combination therapy did not show a significant advantage over the mono-therapy.
CONCLUSIONS
Intrauterine infusion of HCG, PBMC, G-CSF, and PRP are promising strategies for improving pregnancy outcomes for infertile patients with recurrent implantation failure. Among these treatments, PRP may be the best. More researches are required to explore the effect of drug combinations and less commonly used drugs as well.
TRIAL REGISTRATION
Our study was registered in PROSPERO and the ID was CRD42023467188.
Topics: Pregnancy; Female; Humans; Prospective Studies; Leukocytes, Mononuclear; Network Meta-Analysis; Embryo Implantation; Chorionic Gonadotropin; Infertility, Female; Granulocyte Colony-Stimulating Factor; Pregnancy Rate
PubMed: 38627790
DOI: 10.1186/s12958-024-01221-x -
Disease Models & Mechanisms May 2024Preclinical and clinical studies on the administration of bone marrow-derived cells to restore perfusion show conflicting results. We conducted a systematic review and... (Meta-Analysis)
Meta-Analysis
Preclinical and clinical studies on the administration of bone marrow-derived cells to restore perfusion show conflicting results. We conducted a systematic review and meta-analysis on preclinical studies to assess the efficacy of bone marrow-derived cells in the hind limb ischemia model and identify possible determinants of therapeutic efficacy. In vivo animal studies were identified using a systematic search in PubMed and EMBASE on 10 January 2022. 85 studies were included for systematic review and meta-analysis. Study characteristics and outcome data on relative perfusion were extracted. The pooled mean difference was estimated using a random effects model. Risk of bias was assessed for all included studies. We found a significant increase in perfusion in the affected limb after administration of bone marrow-derived cells compared to that in the control groups. However, there was a high heterogeneity between studies, which could not be explained. There was a high degree of incomplete reporting across studies. We therefore conclude that the current quality of preclinical research is insufficient (low certainty level as per GRADE assessment) to identify specific factors that might improve human clinical trials.
Topics: Animals; Hindlimb; Ischemia; Bone Marrow Cells; Perfusion; Bone Marrow Transplantation; Humans; Publication Bias; Cell- and Tissue-Based Therapy
PubMed: 38616715
DOI: 10.1242/dmm.050632