BMC Medical Imaging Jul 2024The detection and management of intracranial aneurysms (IAs) are vital to prevent life-threatening complications like subarachnoid hemorrhage (SAH). Artificial...
BACKGROUND
The detection and management of intracranial aneurysms (IAs) are vital to prevent life-threatening complications like subarachnoid hemorrhage (SAH). Artificial Intelligence (AI) can analyze medical images, like CTA or MRA, spotting nuances possibly overlooked by humans. Early detection facilitates timely interventions and improved outcomes. Moreover, AI algorithms offer quantitative data on aneurysm attributes, aiding in long-term monitoring and assessing rupture risks.
METHODS
We screened four databases (PubMed, Web of Science, IEEE and Scopus) for studies using artificial intelligence algorithms to identify IA. Based on algorithmic methodologies, we categorized them into classification, segmentation, detection and combined, and then their merits and shortcomings are compared. Subsequently, we elucidate potential challenges that contemporary algorithms might encounter within real-world clinical diagnostic contexts. Then we outline prospective research trajectories and underscore key concerns in this evolving field.
RESULTS
Forty-seven studies of IA recognition based on AI were included based on search and screening criteria. The retrospective results represent that current studies can identify IA in different modal images and predict their risk of rupture and blockage. In clinical diagnosis, AI can effectively improve the diagnostic accuracy of IA and reduce missed detection and false positives.
CONCLUSIONS
The AI algorithm can detect unobtrusive IA more accurately in communicating arteries and cavernous sinus arteries to avoid further expansion. In addition, analyzing aneurysm rupture and blockage before and after surgery can help doctors plan treatment and reduce the uncertainties in the treatment process.
Topics: Intracranial Aneurysm; Humans; Artificial Intelligence; Algorithms; Magnetic Resonance Angiography
PubMed: 38956538
DOI: 10.1186/s12880-024-01347-9 -
Infection Jun 2024The landscape of Pseudomonas infective endocarditis (IE) is evolving with the widespread use of cardiac implantable devices and hospital-acquired infections. This... (Review)
Review
BACKGROUND
The landscape of Pseudomonas infective endocarditis (IE) is evolving with the widespread use of cardiac implantable devices and hospital-acquired infections. This systematic review aimed to evaluate the emerging risk factors and outcomes in Pseudomonas IE.
METHODS
A literature search was performed in major electronic databases (PubMed, Scopus, and Google Scholar) with appropriate keywords and combinations till November 2023. We recorded data for risk factors, diagnostic and treatment modalities. This study is registered with PROSPERO, CRD42023442807.
RESULTS
A total of 218 cases (131 articles) were included. Intravenous drug use (IDUs) and prosthetic valve endocarditis (PVE) were major risk factors for IE (37.6% and 22%). However, the prosthetic valve was the predominant risk factor in the last two decades (23.5%). Paravalvular complications (paravalvular leak, abscess, or pseudoaneurysm) were described in 40 cases (18%), and the vast majority belonged to the aortic valve (70%). The mean time from symptom onset to presentation was 14 days. The incidence of difficult-to-treat resistant (DTR) pseudomonas was 7.4%. Valve replacement was performed in 57.3% of cases. Combination antibiotics were used in most cases (77%), with the aminoglycosides-based combination being the most frequently used (66%). The overall mortality rate was 26.1%. The recurrence rate was 11.2%. Almost half of these patients were IDUs (47%), and most had aortic valve endocarditis (76%).
CONCLUSIONS
This review highlights the changing epidemiology of Pseudomonas endocarditis with the emergence of prosthetic valve infections. Acute presentation and associated high mortality are characteristic of Pseudomonas IE and require aggressive diagnostic and therapeutic approach.
PubMed: 38856808
DOI: 10.1007/s15010-024-02311-z -
World Journal of Surgery Jun 2024The aim of this systematic review was to assess the estimated incidence of pseudoaneurysm (PSA) with follow-up computed tomography (CT) for adult splenic injury with...
BACKGROUND
The aim of this systematic review was to assess the estimated incidence of pseudoaneurysm (PSA) with follow-up computed tomography (CT) for adult splenic injury with nonoperative management (NOM).
METHODS
A systematic literature search was conducted in MEDLINE, Central, CINAHL, Clinical Trials, and ICTRP databases between January 1, 2010, and December 31, 2023. Quality assessment was performed using the Risk of Bias in Non-randomized Studies of Exposures (ROBINS-E) tool. Adult splenic injury patients who were initially managed with NOM and followed-up by protocolized CT were included. The primary outcome was the incidence of delayed PSA. Secondary outcome measures were delayed angiography and delayed splenectomy. Subgroup analyses were performed between NOM patients without initial splenic angioembolization (SAE) and NOM patients with initial SAE.
RESULTS
Twelve studies were enrolled, including 11 retrospective studies and one prospective study, with 1746 patients in total. The follow-up CT rate in the included patients was 94.9%. The estimated incidence of PSA was 14% (95% confidence interval (CI), 8%-21%). The estimated delayed angiography and delayed splenectomy incidence rates were 7% (95% CI, 4%-12%) and 2% (95% CI, 1%-6%), respectively. Subgroup analyses showed that the estimated PSA incidence was 12% in NOM patients without initial SAE (95% CI, 7%-20%) and was also 12% in NOM patients with SAE (95% CI, 5%-24%).
CONCLUSIONS
The estimated incidence of delayed PSA after follow-up CT for adult splenic injury with NOM was 14%. The estimated incidence of PSA in NOM with initial SAE was similar to that in NOM without initial SAE.
PubMed: 38831256
DOI: 10.1002/wjs.12238 -
Cureus Apr 2024Modern neuroimaging methods do not completely rule out false diagnoses of intracranial aneurysms which can lead to an unwarranted operation associated with risks of... (Review)
Review
Modern neuroimaging methods do not completely rule out false diagnoses of intracranial aneurysms which can lead to an unwarranted operation associated with risks of complications. However, surgical interventions for falsely diagnosed aneurysms are quite rare. The purpose of this study is to demonstrate two clinical cases of false-positive aneurysms and a systematic review of the literature dedicated to the incidence and etiology of false-positive aneurysms, identifying risk factors associated with false-positive aneurysms. A literature search in two databases (PubMed and Web of Science) using keywords "mimicking an intracranial aneurysm", "presenting as an intracranial aneurysm", "false positive intracranial aneurysms", and "neurosurgery" was conducted. A total of 243 papers were found in the initial search in two databases. Sixteen papers (including 20 patients) were included in the final analysis. There were 10 women and 10 men. The most common location of false-positive aneurysms was the bifurcation of the middle cerebral artery (MCA). In the posterior circulation, false-positive aneurysms were identified either on the basilar artery, or at the vertebro-basilar junction. The main causes of false intracranial aneurysm diagnosis included artery occlusion with vascular stump formation, infundibular widening, fenestration, arterial dissection, contrast extravasation, and venous varix. In conclusion, summarizing the results of our analysis, we can say that surgical interventions for false-positive aneurysms are an underestimated problem in vascular neurosurgery. Despite extremely rare published clinical observations, the actual frequency of erroneous surgical interventions for false-positive aneurysms is unknown.
PubMed: 38807799
DOI: 10.7759/cureus.59185 -
Journal of Cardiothoracic Surgery May 2024A fistulous tract in the mitro-aortic intervalvular fibrosa (MAIVF) is a rare entity, which presents as a complication of endocarditis or surgical trauma. Generally, it...
BACKGROUND
A fistulous tract in the mitro-aortic intervalvular fibrosa (MAIVF) is a rare entity, which presents as a complication of endocarditis or surgical trauma. Generally, it is associated to a pseudoaneurysm of the MAIVF (p-MAIVF) or aortic abscesses. MAIVF fistulas could potentially lead to devastating complications and a high mortality rate. This condition is managed surgically, either by a percutaneous closure or an open surgical approach. Herein we report the complex case of a patient with a MAIVF fistula secondary to bacterial endocarditis. Further clinical deterioration was caused by severe aortic valve insufficiency and hemodynamic compromise, requiring surgical intervention.
CASE PRESENTATION
A 74-year-old male patient was admitted to a primary care center with complaints of malaise, asthenia, adynamia, hyporexia, and lower limb edema over the past eight days. His past medical history is positive for arterial hypertension and being monorenal. A transesophageal echocardiogram (TEE) was performed, exhibiting a 56% left ventricle ejection fraction (LVEF) and complicated aortic valve endocarditis. Surgical management through an open approach included vegetation resection, valve replacement, and closure of the MAIVF fistula. After completing antibiotic therapy, the patient was discharged without complications. During postoperative follow-up, the patient remained asymptomatic, and the control echocardiogram showed no signs of MAIVF fistula.4.
CONCLUSIONS
The clinical case of a patient with a MAIVF fistula secondary to endocarditis by Streptococcus Anginous was presented. The fistulous tract was not associated to p-MAIVF or aortic abscess, findings which further deteriorate the patient's condition and increase the likelihood of fatality. This case reinforces the importance of a prompt diagnosis through cardiac imaging and timely surgical closure of the defect.
Topics: Humans; Male; Aged; Endocarditis, Bacterial; Aortic Valve; Mitral Valve; Echocardiography, Transesophageal; Fistula
PubMed: 38807242
DOI: 10.1186/s13019-024-02736-5 -
Vascular May 2024Blunt thoracic aortic injuries (BTAIs) involving the aortic arch are a challenging condition. Thoracic endovascular aortic repair (TEVAR) with fenestration, which...
OBJECTIVES
Blunt thoracic aortic injuries (BTAIs) involving the aortic arch are a challenging condition. Thoracic endovascular aortic repair (TEVAR) with fenestration, which expands the proximal landing zone, is able to exclude the injury while preserving blood flow in supra-aortic branches.
METHODS
Here we report a case of TEVAR with fenestrations of all supra-aortic branches for traumatic aortic pseudoaneurysm and perform a systematic review.
RESULTS
A 24-year-old man suffering a blunt thoracic injury and a left femoral fracture was sent to our hospital. A pseudoaneurysm was found in the aortic arch between the brachiocephalic artery and the left common carotid artery. The patient underwent emergent TEVAR with fenestrations of all supra-aortic branches, which excluded the pseudoaneurysm and preserved the patency of all branches. The orthopedic team then treated the femoral fracture. The patient's recovery was unremarkable. We performed a systematic review on TEVAR with fenestrations for BTAI. Six patients (75%) received TEVAR with single fenestration, 1 patient (12.5%) received TEVAR with two fenestrations, and 1 patient (12.5%) had fenestrations of all supra-aortic branches. Except one patient died in the perioperative, other patients survived without stent-related complications in the short-term follow-up.
CONCLUSIONS
TEVAR with fenestration is feasible for treating BTAI involving the aortic arch in selected patients.
PubMed: 38739928
DOI: 10.1177/17085381241254427 -
Artificial Organs Jun 2024LVAD outflow graft stenosis continues to remain prevalent with a high complication rate. We sought to pool the existing evidence on indications, utilization patterns,... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
LVAD outflow graft stenosis continues to remain prevalent with a high complication rate. We sought to pool the existing evidence on indications, utilization patterns, and outcomes of transcatheter interventions for outflow graft stenosis in the HeartMate 3 LVAD.
METHODS
An electronic search was performed to identify all studies in the English literature reporting on HeartMate 3 LVAD outflow graft stenting. Patient-level data were extracted for analysis.
RESULTS
Thirteen published reports and one unpublished case comprising a total of 28 patients were included. Median patient age was 68.5 years [Interquartile range: 58, 71] and 25.9% (7/27) were female. Dyspnea [60.7% (17/28)] was the most common presenting symptom. Low flow alarms were present in 60% (15/25) of patients. Findings included external compression [35.7% (10/28)], graft twist [21.4% (6/28)], graft twist and external compression [14.3% (4.28)], intraluminal thrombus [10.7% (3/28)], graft twist and intraluminal thrombus [3.6% (1/28)], and pseudoaneurysm of outflow graft [3.6% (1/28)]. Median time from LVAD implantation to stenting was 2.1 years [1.4, 3]. Immediate flow normalization after stenting was observed in 85.7% (24/28). The 30-day mortality was 12% (3/25). Overall mortality was 12% (3/25) at a median follow-up of 3.9 months [1, 17].
CONCLUSION
Outflow graft stenting in the HeartMate 3 LVAD appears to be a reasonable treatment option for outflow graft stenosis, with low overall rates of complications and mortality. Further refinement of indications and approaches may improve outcomes.
Topics: Humans; Heart-Assist Devices; Stents; Treatment Outcome; Heart Failure; Female; Middle Aged; Aged; Male
PubMed: 38577853
DOI: 10.1111/aor.14736 -
Clinical Case Reports Apr 2024This is a case of 83 years old male who had radial artery pseudoaneurysm after cardiac catheterization. The diagnosis was through Doppler ultrasound and the patient...
This is a case of 83 years old male who had radial artery pseudoaneurysm after cardiac catheterization. The diagnosis was through Doppler ultrasound and the patient was treated with thrombin injection and reported good outcomes. The literature also included 41 cases of pseudoaneurysm after catheterization. The mean age of patients was 68.5 years with a male prevalence of 49%. Onset of pseudoaneurysm ranged from 0 days (directly after the catheterization) to 150 days with a median of 5 days. The treatment of patients was mainly surgical (19 cases) followed by compression (either manual or TR band) (12 cases), thrombin injection (four cases), compression then surgery (three cases), compression then thrombin injection (one case), percutaneous endovascular repair using a covered stent (one case) and not reported in one case. All cases recovered well.
PubMed: 38560282
DOI: 10.1002/ccr3.8725 -
World Neurosurgery Apr 2024The optimal stenting approach for traumatic pseudoaneurysms (PSA) of the extracranial internal carotid artery (ICA) remains underinvestigated. We present a case of a...
BACKGROUND
The optimal stenting approach for traumatic pseudoaneurysms (PSA) of the extracranial internal carotid artery (ICA) remains underinvestigated. We present a case of a traumatic pseudoaneurysm of the extracranial ICA managed with stenting and review of prior published similar cases.
METHODS
The systematic review followed PRISMA-S guidelines and included studies that investigated traumatic pseudoaneurysms of the extracranial ICA managed by stent placement. Statistical analysis assessed the association between the type of injury and stent type, dual antiplatelet therapy (DAPT) duration, and clinical presentation, and the association between stent type and DAPT duration.
RESULTS
Our search yielded 82 publications with 135 patients with extracranial ICA PSA treated with stenting. The odds of neck hematoma presentation was 12.2 times greater for patients with penetrating rather than blunt injuries (P = 0.000002). Covered stents had 2.02 times higher odds of use for penetrating rather than blunt injuries compared to bare metal stents. (P = 0.0029). Shorter duration DAPT was seen with bare metal stents having 1.25 higher odds of DAPT duration less than one month compared to covered (P = 0.001).
CONCLUSIONS
In traumatic extracranial ICA pseudoaneurysms, covered stents are used more commonly for penetrating injuries compared to blunt injuries. Penetrating injuries are more strongly associated with the presentation of a hematoma compared to blunt injuries. Stent type may influence the recommended DAPT duration. Surgeons should consider these findings when selecting stent type and DAPT duration with patients presenting with traumatic extracranial ICA pseudoaneurysm.
Topics: Humans; Aneurysm, False; Carotid Artery, Internal; Carotid Artery Injuries; Platelet Aggregation Inhibitors; Stents; Wounds, Nonpenetrating; Hematoma; Treatment Outcome; Endovascular Procedures
PubMed: 38336211
DOI: 10.1016/j.wneu.2024.02.002 -
Vascular and Endovascular Surgery Jul 2024Median Arcuate Ligament Syndrome (MALS) is associated with true aneurysms, mainly of both the pancreaticoduodenal artery (PDA) and gastroduodenal artery (GDA). Although... (Review)
Review
Median Arcuate Ligament Syndrome (MALS) is associated with true aneurysms, mainly of both the pancreaticoduodenal artery (PDA) and gastroduodenal artery (GDA). Although rare, their potential for rupture and adverse clinical outcomes warrants analysis. Prior studies suggest high rupture rates even for smaller aneurysms under 2 cm in this setting. We performed a systematic literature review, synthesising the evidence on visceral artery aneurysms related to MAL syndrome, with a focus on descriptive analyses of aneurysm size, presentation, rupture rates, and management. Literature search was performed using (Medline, EMBASE, Emcare and CINAHL). Inclusion criteria included true aneurysms secondary to MALS with or without rupture. The cases with pseudoaneurysms, concomitant pathologies eg, pancreatitis, conservatively managed aneurysms and articles with non-granular pooled data were excluded. Cases were assessed according to demographics, clinical presentation, aneurysm diameter, aneurysm rupture and management technique. 39 articles describing 72 patients were identified. Aneurysm diameter in symptomatic patients was not significantly different from asymptomatic patients {21.0 and 22.3 mm respectively, = .84}. Ruptured aneurysms were overall smaller than non-ruptured at presentation {12.3 mm v 30.8 mm respectively, = .02}. Patients presented with abdominal pain (75.6%), nausea/vomiting (15.6%), hypotension (33.9%), shock (20.0%) and haemodynamic collapse (8.9%). 56.9% of all cases were managed with an endovascular approach, 19.4% were managed with an open surgical approach, and 23.6% were managed hybrid. This review suggests visceral artery aneurysms associated with median arcuate ligament rupture at variable sizes. Despite inability to clearly correlate size and rupture risk, our data supports prompt intervention irrespective of size, given the adverse outcomes. Further research is critically needed to clarify size thresholds or other predictors to guide management.
Topics: Humans; Median Arcuate Ligament Syndrome; Aneurysm; Treatment Outcome; Risk Factors; Aneurysm, Ruptured; Female; Middle Aged; Male; Aged; Adult; Arteries; Endovascular Procedures; Aged, 80 and over; Viscera; Risk Assessment
PubMed: 38271562
DOI: 10.1177/15385744241229842