-
The Journal of Thoracic and... Jun 2024Aortic root replacement requires construction of a composite valve-graft and reimplantation of coronary arteries. This study assessed the feasibility of valve-in-valve...
OBJECTIVE
Aortic root replacement requires construction of a composite valve-graft and reimplantation of coronary arteries. This study assessed the feasibility of valve-in-valve transcatheter aortic valve implantation after aortic root replacement.
METHODS
A retrospective review was conducted on 74 consecutive patients who received a composite valve-graft at a single institution from 2019 to 2021. Forty patients had bioprosthetic valves with adequate postoperative gated computed tomographic angiography scans. Computational simulations of balloon and self-expanding transcatheter valve deployments were performed. The modeled coronary distances were compared to traditional, manually measured valve-to-coronary distances.
RESULTS
There was a statistically significant difference in the modeled versus manual measurements of valve to coronary distances were for all patients regardless of valve type or coronary artery analyzed (p <0. 05). Most patients are low risk for coronary obstruction per three-dimensional modeling including those with a valve-to-coronary distance <4 millimeters. Only one patient (2.5%) was at risk for coronary obstruction for the left coronary artery using a ballonvalve. No other valve combination was considered high risk of coronary obstruction. Five patients (12.5%) were at risk for possible valve stent deformation at the outflow, due to angulation at the graft anastomosis.
CONCLUSIONS
Following aortic root replacement, all patients were candidates for Valve-in-Valve using one or both types of transcatheter heart valves. Self-expanding valves may be at higher risk for stent frame deformation at graft anastomotic lines and balloon-expandable valves may be at higher risk of coronary obstruction.
PubMed: 38950772
DOI: 10.1016/j.jtcvs.2024.06.024 -
IEEE Transactions on Bio-medical... Jul 2024Total artificial heart (TAH) using dual rotary blood pumps (RBPs) is a potential treatment for end-stage heart failure. A well-noted challenge with RBPs is their low...
OBJECTIVE
Total artificial heart (TAH) using dual rotary blood pumps (RBPs) is a potential treatment for end-stage heart failure. A well-noted challenge with RBPs is their low sensitivity to preload, which can lead to venous congestion and ventricular suction. To address this issue, we have developed an innovative closed-loop control system of dual RBPs in TAH. This system emulates the Frank-Starling law of the heart in controlling RBPs while monitoring stressed blood volume (V) based on the circulatory equilibrium framework. We validated the system in in-vivo experiments.
METHODS
In 9 anesthetized dogs, we prepared a TAH circuit using 2 centrifugal-type RBPs. We first investigated whether the flow and inlet atrial pressure in each RBP adhered to a logarithmic Frank-Starling curve. We then examined whether the RBP flows and atrial pressures were maintained stably during aortic occlusion (AO) and pulmonary cannula stenosis (PS), whether averaged flow of dual RBPs and bilateral atrial pressures were controlled to their predefined target values for a specific V, and whether this system could maintain the atrial pressures within predefined control ranges under significant changes in V.
RESULTS
This system effectively emulated the logarithmic Frank-Starling curve. It robustly stabilized the flow and atrial pressures during AO and PS without venous congestion or ventricular suction, accurately achieved target values in averaged flow and atrial pressures, and efficaciously maintained these pressures within the control ranges.
CONCLUSION
This system controls dual RBPs in TAH accurately and stably.
SIGNIFICANCE
This system may accelerate clinical application of TAH with dual RBPs.
PubMed: 38949936
DOI: 10.1109/TBME.2024.3420907 -
ASAIO Journal (American Society For... Jul 2024We report the largest pediatric multicenter experience with Impella pump use and peripheral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support....
We report the largest pediatric multicenter experience with Impella pump use and peripheral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support. Utilizing the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) collaborative database, we conducted a retrospective, multicenter study of all patients with cardiogenic shock requiring VA-ECMO support with subsequent Impella implant between October 2014 and December 2021. The primary outcome was defined as death while on Impella support. Secondary outcomes were recovery, transplantation, and transition to durable ventricular assist device (VAD) at the time of Impella explantation. Adverse events were defined according to the ACTION registry criteria. Twenty subjects were supported with Impella; Impella 2.5 (n = 3), CP (n = 12), 5.0/5.5 (n = 5). The median Interquartile range (IQR) age, weight, and body surface area at implantation were 15.6 years (IQR = 13.9-17.2), 65.7 kg (IQR = 53.1-80.7), and 1.74 m2 (IQR = 1.58-1.98). Primary cardiac diagnoses were dilated cardiomyopathy/myocarditis in nine (45%), congenital heart disease in four (20%), graft failure/rejection in four (20%), and three (15%) others. Most common adverse events included hemolysis (50%) and bleeding (20%). There were two deaths (10%) in the cohort. Nine patients (45%) were explanted for recovery, eight (40%) were transitioned to a durable VAD, and one (5%) underwent heart transplantation. Impella percutaneous pump support should be considered in the older pediatric population supported with peripheral VA-ECMO, as a means of left heart decompression, and a strategy to come off ECMO to achieve endpoints of myocardial recovery, transition to a durable VAD, or transplantation.
Topics: Humans; Extracorporeal Membrane Oxygenation; Heart-Assist Devices; Retrospective Studies; Male; Female; Adolescent; Shock, Cardiogenic; Child; Child, Preschool; Treatment Outcome
PubMed: 38949774
DOI: 10.1097/MAT.0000000000002150 -
ASAIO Journal (American Society For... Jul 2024National trends show rapid increases in the use of mechanical circulatory support devices (MCSD) over the last 20 years. While current literature has not proven a...
National trends show rapid increases in the use of mechanical circulatory support devices (MCSD) over the last 20 years. While current literature has not proven a mortality benefit in cardiogenic shock as a complication of acute myocardial infarction (AMI-CS) with percutaneous MCSD, these devices are vital to maximizing cardiopulmonary parameters for definitive therapy. To minimize complications, many different techniques have been described including a novel off-pump direct apical cannulation for venoarterial-extracorporeal membrane oxygenation (VA-ECMO). This technique allows early ambulation and avoids peripheral artery access complications but has only been described in small case series. Our case series represents the largest summary of patients (50) using this technique and contains the only comparison data to date. Fifty-four percentage of our patients were Society for Cardiovascular Angiography and Interventions (SCAI) stage D and 22% were arrested before cannulation. We achieved flows on average >5 L/min and most patients required biventricular drainage (86%) and an oxygenator (92%). Thirty day survival was 56% and most survivors were bridged to heart transplant (30%). Our most common complication was bleeding (16%). This technique showed significant improvement in ejection fraction (EF), cardiac output/index (CO/CI), and pulmonary artery pressures. This case series demonstrates the safety and efficacy of this novel technique for central cannulation in cardiogenic shock at large scale within a single institution.
Topics: Humans; Extracorporeal Membrane Oxygenation; Middle Aged; Male; Female; Shock, Cardiogenic; Cannula; Aged; Thoracotomy; Catheterization; Adult; Myocardial Infarction; Heart-Assist Devices
PubMed: 38949771
DOI: 10.1097/MAT.0000000000002157 -
Ultrasound in Obstetrics & Gynecology :... Jul 2024
Topics: Humans; Female; Pregnancy; Ultrasonography, Prenatal; Artificial Intelligence; Heart Defects, Congenital; Fetal Heart
PubMed: 38949769
DOI: 10.1002/uog.27703 -
Clinical and Translational Science Jul 2024Physiological determinants of drug dosing (PDODD) are a promising approach for precision dosing. This study investigates the alterations of PDODD in diseases and...
Physiological determinants of drug dosing (PDODD) are a promising approach for precision dosing. This study investigates the alterations of PDODD in diseases and evaluates a variational autoencoder (VAE) artificial intelligence model for PDODD. The PDODD panel contained 20 biomarkers, and 13 renal, hepatic, diabetes, and cardiac disease status variables. Demographic characteristics, anthropometric measurements (body weight, body surface area, waist circumference), blood (plasma volume, albumin), renal (creatinine, glomerular filtration rate, urine flow, and urine albumin to creatinine ratio), and hepatic (R-value, hepatic steatosis index, drug-induced liver injury index), blood cell (systemic inflammation index, red cell, lymphocyte, neutrophils, and platelet counts) biomarkers, and medical questionnaire responses from the National Health and Nutrition Examination Survey (NHANES) were included. The tabular VAE (TVAE) generative model was implemented with the Synthetic Data Vault Python library. The joint distributions of the generated data vs. test data were compared using graphical univariate, bivariate, and multidimensional projection methods and distribution proximity measures. The PDODD biomarkers related to disease progression were altered as expected in renal, hepatic, diabetes, and cardiac diseases. The continuous PDODD panel variables generated by the TVAE satisfactorily approximated the distribution in the test data. The TVAE-generated distributions of some discrete variables deviated from the test data distribution. The age distribution of TVAE-generated continuous variables was similar to the test data. The TVAE algorithm demonstrated potential as an AI model for continuous PDODD and could be useful for generating virtual populations for clinical trial simulations.
Topics: Humans; Male; Female; Middle Aged; Heart Diseases; Kidney Diseases; Biomarkers; Adult; Liver Diseases; Aged; Metabolic Diseases; Artificial Intelligence; Nutrition Surveys; Drug Dosage Calculations; Models, Biological
PubMed: 38949489
DOI: 10.1111/cts.13872 -
Journal of Cardiovascular Medicine... Aug 2024
Topics: Humans; Shock, Cardiogenic; Heart-Assist Devices; Treatment Outcome; Male; Intra-Aortic Balloon Pumping; Recovery of Function
PubMed: 38949148
DOI: 10.2459/JCM.0000000000001640 -
Journal of Magnetic Resonance Imaging :... Jul 2024Myocardial T1-rho (T1ρ) mapping is a promising method for identifying and quantifying myocardial injuries without contrast agents, but its clinical use is hindered by...
BACKGROUND
Myocardial T1-rho (T1ρ) mapping is a promising method for identifying and quantifying myocardial injuries without contrast agents, but its clinical use is hindered by the lack of dedicated analysis tools.
PURPOSE
To explore the feasibility of clinically integrated artificial intelligence-driven analysis for efficient and automated myocardial T1ρ mapping.
STUDY TYPE
Retrospective.
POPULATION
Five hundred seventy-three patients divided into a training (N = 500) and a test set (N = 73) including ischemic and nonischemic cases.
FIELD STRENGTH/SEQUENCE
Single-shot bSSFP T1ρ mapping sequence at 1.5 T.
ASSESSMENT
The automated process included: left ventricular (LV) wall segmentation, right ventricular insertion point detection and creation of a 16-segment model for segmental T1ρ value analysis. Two radiologists (20 and 7 years of MRI experience) provided ground truth annotations. Interobserver variability and segmentation quality were assessed using the Dice coefficient with manual segmentation as reference standard. Global and segmental T1ρ values were compared. Processing times were measured.
STATISTICAL TESTS
Intraclass correlation coefficients (ICCs) and Bland-Altman analysis (bias ±2SD); Paired Student's t-tests and one-way ANOVA. A P value <0.05 was considered significant.
RESULTS
The automated approach significantly reduced processing time (3 seconds vs. 1 minute 51 seconds ± 22 seconds). In the test set, automated LV wall segmentation closely matched manual results (Dice 81.9% ± 9.0) and closely aligned with interobserver segmentation (Dice 82.2% ± 6.5). Excellent ICCs were achieved on a patient basis (0.94 [95% CI: 0.91 to 0.96]) with bias of -0.93 cm ± 6.60. There was no significant difference in global T1ρ values between manual (54.9 msec ± 4.6; 95% CI: 53.8 to 56.0 msec, range: 46.6-70.9 msec) and automated processing (55.4 msec ± 5.1; 95% CI: 54.2 to 56.6 msec; range: 46.4-75.1 msec; P = 0.099). The pipeline demonstrated a high level of agreement with manual-derived T1ρ values at the patient level (ICC = 0.85; bias +0.52 msec ± 5.18). No significant differences in myocardial T1ρ values were found between methods across the 16 segments (P = 0.75).
DATA CONCLUSION
Automated myocardial T1ρ mapping shows promise for the rapid and noninvasive assessment of heart disease.
EVIDENCE LEVEL
3 TECHNICAL EFFICACY: Stage 1.
PubMed: 38949101
DOI: 10.1002/jmri.29502 -
JPMA. the Journal of the Pakistan... Jun 2024This communication defines and describes the novel concept of endocrine entropy. The authors share insights regarding the various facets of entropy in endocrine...
This communication defines and describes the novel concept of endocrine entropy. The authors share insights regarding the various facets of entropy in endocrine epidemiology, physiology, clinical presentation and management. The discussion opens up a new way of approaching endocrinology. Recent advances in artificial intelligence, assessment and addressal of entropy may become integral part of endocrine diagnostics and therapeutics.
Topics: Humans; Entropy; Endocrine System Diseases; Endocrinology; Artificial Intelligence
PubMed: 38948999
DOI: 10.47391/JPMA.24-43 -
JPMA. the Journal of the Pakistan... Jun 2024This communication defines and describes the novel concept of endocrine entropy. The authors share insights regarding the various facets of entropy in endocrine...
This communication defines and describes the novel concept of endocrine entropy. The authors share insights regarding the various facets of entropy in endocrine epidemiology, physiology, clinical presentation and management. The discussion opens up a new way of approaching endocrinology. Recent advances in artificial intelligence, assessment and addressal of entropy may become integral part of endocrine diagnostics and therapeutics.
Topics: Humans; Entropy; Endocrine System Diseases; Endocrinology; Artificial Intelligence
PubMed: 38948998
DOI: 10.47391/JPMA.24-39