-
Journal of Parkinson's Disease Jun 2024Reduced spontaneous blinking is a recognized Parkinson's disease (PD) feature. In contrast, voluntary blinking has been less studied and might serve as a measurable...
Reduced spontaneous blinking is a recognized Parkinson's disease (PD) feature. In contrast, voluntary blinking has been less studied and might serve as a measurable marker of facial bradykinesia. We tested 31 PD patients and 31 controls. Participants were filmed during conversation and a rapid blinking task. Both tasks were videorecorded to count the number of blinks per second. PD patients had lower blink rates. Rapid blinking accurately discriminated between groups with 77% sensitivity and 71% specificity. To conclude, rapid blinking may be a simple and quantifiable task of facial bradykinesia.
PubMed: 38943397
DOI: 10.3233/JPD-240005 -
Nigerian Journal of Clinical Practice Jun 2024
Topics: Humans; Ameloblastoma; Jaw Neoplasms
PubMed: 38943308
DOI: 10.4103/njcp.njcp_63_24 -
Nigerian Journal of Clinical Practice Jun 2024Apically extruded debris can be affected by some features of the file systems such as kinematics or metallurgic properties.
BACKGROUND
Apically extruded debris can be affected by some features of the file systems such as kinematics or metallurgic properties.
AIMS
This in vitro study aimed to evaluate the effect of movement kinematics (reciprocation or rotation) and heat-treated alloys (C.Wire) on the amount of debris extrusion.
METHODS
Seventy-two mesiobuccal root canals were assigned into three experimental groups related to the single-file system used (n = 24): two rotational; One Shape (Conventional Ni-Ti), One Curve (C.Wire), and one reciprocating; and One Reci (C.Wire). The file systems were used according to the advisable speed and torque according to the manufacturers' suggestion. The weight of debris was calculated by subtracting the preweights from postweights of Eppendorf tubes. Kruskall-Wallis and Mann-Whitney U tests were used to analyze the data (P = 0.05).
RESULTS
One Shape produced the greatest amount of extruded debris compared with One Curve (P < 0.001) and One Reci (P < 0.001), respectively. No statistical difference was found between One Curve and One Reci concerning amount of apical debris extrusion (P = 0.489).
CONCLUSION
Metallurgical properties of files may affect apical debris extrusion. Alloy type is an important factor in the amount of debris extrusion. File kinematics does not affect apical debris extrusion.
Topics: Humans; Alloys; Root Canal Preparation; Hot Temperature; Biomechanical Phenomena; In Vitro Techniques; Materials Testing; Equipment Design; Nickel; Dental Pulp Cavity
PubMed: 38943303
DOI: 10.4103/njcp.njcp_889_23 -
Nigerian Journal of Clinical Practice Jun 2024This study aims to assess the diagnostic accuracy of an artificial intelligence (AI) system employing deep learning for identifying dental plaque, utilizing a dataset...
OBJECTIVES
This study aims to assess the diagnostic accuracy of an artificial intelligence (AI) system employing deep learning for identifying dental plaque, utilizing a dataset comprising photographs of permanent teeth.
MATERIALS AND METHODS
In this study, photographs of 168 teeth belonging to 20 patients aged between 10 and 15 years, who met our criteria, were included. Intraoral photographs were taken of the patients in two stages, before and after the application of the plaque staining agent. To train the AI system to identify plaque on teeth with dental plaque that is not discolored, plaque and teeth were marked on photos with exposed dental plaque. One hundred forty teeth were used to construct the training group, while 28 teeth were used to create the test group. Another dentist reviewed images of teeth with dental plaque that was not discolored, and the effectiveness of AI in detecting plaque was evaluated using pertinent performance indicators. To compare the AI model and the dentist's evaluation outcomes, the mean intersection over union (IoU) values were evaluated by the Wilcoxon test.
RESULTS
The AI system showed higher performance in our study with a precision of 82% accuracy, 84% sensitivity, 83% F1 score, 87% accuracy, and 89% specificity in plaque detection. The area under the curve (AUC) value was found to be 0.922, and the IoU value was 76%. Subsequently, the dentist's plaque diagnosis performance was also evaluated. The IoU value was 0.71, and the AUC was 0.833. The AI model showed statistically significantly higher performance than the dentist (P < 0.05).
CONCLUSIONS
The AI algorithm that we developed has achieved promising results and demonstrated clinically acceptable performance in detecting dental plaque compared to a dentist.
Topics: Humans; Artificial Intelligence; Adolescent; Child; Dental Plaque; Female; Male; Sensitivity and Specificity; Deep Learning
PubMed: 38943301
DOI: 10.4103/njcp.njcp_862_23 -
Nigerian Journal of Clinical Practice Jun 2024Sex determination from the bones is of great importance for forensic medicine and anthropology. The mandible is highly valued because it is the strongest, largest and...
BACKGROUND
Sex determination from the bones is of great importance for forensic medicine and anthropology. The mandible is highly valued because it is the strongest, largest and most dimorphic bone in the skull.
AIM
Our aim in this study is gender estimation with morphometric measurements taken from mandibular lingula, an important structure on the mandible, by using machine learning algorithms and artificial neural networks.
METHODS
Cone beam computed tomography images of the mandibular lingula were obtained by retrospective scanning from the Picture Archiving Communication Systems of the Department of Oral, Dental and Maxillofacial Radiology, Faculty of Dentistry, İnönü University. Images scanned in Digital Imaging and Communications in Medicine (DICOM) format were transferred to RadiAnt DICOM Viewer (Version: 2020.2). The images were converted to 3-D format by using the 3D Volume Rendering console of the program. Eight anthropometric parameters were measured bilaterally from these 3-D images based on the mandibular lingula.
RESULTS
The results of the machine learning algorithms analyzed showed that the highest accuracy was 0.88 with Random Forest and Gaussian Naive Bayes algorithm. Accuracy rates of other parameters ranged between 0.78 and 0.88.
CONCLUSIONS
As a result of the study, it is thought that mandibular lingula-centered morphometric measurements can be used for gender determination as well as bones such as the pelvis and skull as they were found to be highly accurate. This study also provides information on the anatomical position of the lingula according to gender in Turkish society. The results can be important for oral-dental surgeons, anthropologists, and forensic experts.
Topics: Humans; Neural Networks, Computer; Male; Female; Mandible; Machine Learning; Retrospective Studies; Adult; Cone-Beam Computed Tomography; Sex Determination by Skeleton; Imaging, Three-Dimensional; Algorithms; Young Adult; Adolescent; Middle Aged
PubMed: 38943297
DOI: 10.4103/njcp.njcp_787_23 -
Nigerian Journal of Clinical Practice Jun 2024Studies have been conducted to evaluate changes in hemodynamics, postoperative bleeding, and pain in pediatric dental patients receiving general anesthesia (GA)....
Retrospective Evaluation of the Effects of Local Anesthesia Before Tooth Extraction Procedures under General Anesthesia on Physiologic Parameters and Postoperative Bleeding in Children.
BACKGROUND
Studies have been conducted to evaluate changes in hemodynamics, postoperative bleeding, and pain in pediatric dental patients receiving general anesthesia (GA). However, a limited number of studies have evaluated the effects of local anesthetics (LA) on tooth extraction procedures during GA. There is no consensus in the literature regarding LA application in the perioperative period for dental treatments performed within the scope of GA.
AIM
This study aimed to determine the retrospective physiologic effects of fluctuations in vital signs and postoperative bleeding in children who did or did not receive LA for tooth extraction under GA.
METHODS
A retrospective evaluation of 77 patients aged 5.16 ± 1.85 years who had the extraction of primary posterior teeth with or without LA under GA were reviewed in the post-anaesthesia care unit (PACU) for postoperative bleeding and the effects of intraoperative LA on fluctuations in postoperative parameters such as mean arterial pressure (MAP), heart rate (HR), peripheral oxygen saturation (SpO2), respiratory rate (RR), and the end-tidal carbon dioxide (EtCO2). These were compiled from the patient records of the procedures.
RESULTS
Significant differences between the baseline and peak MAP (P < 0.001), HR (P = 0.011), and EtCO2 (P = 0.002) were noted in children without LA compared to those who had LA. In addition, substantial variations were observed between the baseline and peak values for MAP (P < 0.001) and HR (P = 0.037) in children who had tooth extraction in the mandibular region. Statistically significant differences were noted between the baseline and peak values for patients who did not receive LA before the extraction of the first primary molar in terms of MAP (P < 0.02) and EtCO2 (P = 0.032). Similarly, significant differences in MAP (P < 0.02) and EtCO2 (P = 0.034) were noted in the extraction of the second primary molar. In addition, there was a significant difference in bleeding based on the number of tooth extractions in those who did not receive LA (P = 0.020).
CONCLUSION
This study showed that in children who underwent tooth extraction under GA, additional LA application minimized changes in HR, MAP, and EtCO2, whereas a lack of LA application produced significant fluctuations from baseline to peak values of HR, MAP, and EtCO2. In addition, LA application reduced postoperative bleeding.
Topics: Humans; Tooth Extraction; Retrospective Studies; Female; Male; Anesthesia, General; Child; Child, Preschool; Anesthesia, Local; Postoperative Hemorrhage; Anesthetics, Local; Heart Rate
PubMed: 38943296
DOI: 10.4103/njcp.njcp_708_23 -
Nigerian Journal of Clinical Practice Jun 2024Genioplasty, a key technique for dentofacial abnormalities, is essential for establishing facial harmony. This surgical procedure entails an osteotomy of the chin, which... (Review)
Review
Genioplasty, a key technique for dentofacial abnormalities, is essential for establishing facial harmony. This surgical procedure entails an osteotomy of the chin, which alters its three-dimensional location to restore overall face equilibrium. Modern genioplasty, which is frequently performed alone or in combination with rhinoplasty, facelifts, and orthognathic surgery, employs a variety of materials for chin augmentation, ranging from autologous to alloplastic. Recent improvements include porous graft materials such as high-density polyethylene. Despite the need for secure osteotomy segments, soft tissues around the mandible have a natural propensity to return to their original anatomical position. In the discipline of genioplasty, face esthetics and facial evaluation have been a prominent emphasis, with historical evidence emphasizing the relevance of the chin in harmony, balance, and character perception. Customized implants provide a single therapy for rare anatomical defects, generally with lower morbidity, making them critical for patients undergoing many procedures or suffering from syndromic disorders. Virtual surgical planning advances will continue to give dependable solutions for small and complex chin position issues. Modern surgeons will continue to combine history, anatomy, rigorous evaluation, excellent execution, and technological breakthroughs to achieve the best possible outcomes for their patients, raising their social standing.
Topics: Humans; Genioplasty; Chin; Osteotomy; Prostheses and Implants; Esthetics
PubMed: 38943291
DOI: 10.4103/njcp.njcp_24_24 -
Journal of Oral Rehabilitation Jun 2024Occlusal contacts can be stained and thereby visualised employing occlusal indicators. Qualitative and quantitative indicators are differentiated. The hybrid system...
BACKGROUND
Occlusal contacts can be stained and thereby visualised employing occlusal indicators. Qualitative and quantitative indicators are differentiated. The hybrid system OccluSense supposedly combines analogue contact marking and digital registration of contacts. The reliability and validity of its contact marking have not yet been validated.
OBJECTIVES
The aim of this controlled randomised in-vitro study was to examine the reliability and validity of analogue contact staining with OccluSense compared to Arti-Fol and the reference standard Gnatho-Film.
MATERIALS AND METHODS
An experimental apparatus was designed to simulate static occlusion. The occlusal contacts were stained 50 times with Gnatho-Film to determine the average number and location of contacts registered. For comparison, the contacts were pre-stained with Gnatho-Film and then registered with Arti-Fol or OccluSense 50 times each. Every staining was statistically evaluated and compared to Gnatho-Film alone, regarding the number and location of contacts. Based on the observed characteristic staining behaviour of OccluSense, a modified evaluation strategy was developed for its colour markings (OccluSense (mod.)).
RESULTS
Both evaluations of OccluSense determine that the same number of contacts was registered in over 94% of all cases. Neither OccluSense nor Arti-Fol stain the exact same number of contacts as Gnatho-Film, but the modified evaluation OccluSense (mod.) did improve the results for validity.
CONCLUSION
When employing the modified evaluation strategy, OccluSense staining achieves similar reliability and validity as the reference standard. Pre-colouring of occlusal contacts with Gnatho-Film and the modified evaluation strategy, might become standard for analysing occlusal contacts stained by OccluSense in the future.
PubMed: 38943246
DOI: 10.1111/joor.13774 -
Journal of Dental Education Jun 2024
PubMed: 38943245
DOI: 10.1002/jdd.13633 -
Medical Science Monitor : International... Jun 2024BACKGROUND This study aimed to evaluate the morphological characteristics of the anterior maxillary nasopalatine canal and the width of the buccal bone using cone-beam...
BACKGROUND This study aimed to evaluate the morphological characteristics of the anterior maxillary nasopalatine canal and the width of the buccal bone using cone-beam computed tomography (CBCT) in 150 adults in Northern Cyprus. MATERIAL AND METHODS The study included 150 participants, and their anterior maxillary morphometric measurements (eg, length of the nasopalatine canal and anteroposterior diameter of the nasal foramen) were taken using CBCT with the scanning parameters of 90 kvP, 24 s, 4 mA, voxel size 0.3 mm, and field of view 10×6 cm. The shapes of the nasopalatine canal (NPC) were categorized into 4 types: cylindrical, hourglass, funnel-shaped, and banana (54%, 20.6%, 18.6%, and 4%, respectively). RESULTS The findings showed a clear link between the shape of the NPC and the horizontal dimensions of the anterior maxilla's morphometric properties. In general, decreased horizontal bone dimensions were found in the premaxilla at the banana- and funnel-shaped type for the nasopalatine canal. Also, the anteroposterior diameter of a nasal foramen in the hourglass shape was significantly larger in diameter than all other shapes. Additionally, the morphology of the nasopalatine canal is influenced by its shape. The sagittal cross-section has shown significant correlations with the sizes of the incisive foramen, nasal foramen, and the length of the nasopalatine canal. CONCLUSIONS The study found a correlation between the shape of the NPC and the horizontal dimensions of the anterior maxilla's anatomy. The measurements of NPC in a North Cyprus population slightly differ from the established standards found in the existing literature. Conducting more extensive studies with a larger number of CBCT images will offer additional insights.
Topics: Humans; Cone-Beam Computed Tomography; Cyprus; Male; Female; Adult; Maxilla; Middle Aged; Palate
PubMed: 38943242
DOI: 10.12659/MSM.944868