Indian Journal of Dental Research :... Jan 2024The application of direct current can have a significant impact on the rate of tooth movement and surrounding periodontal ligament collagen turnover. This study aims to... (Comparative Study)
Comparative Study
An Immunohistochemical and Histological Study of the Animal Periodontal Ligament During Orthodontic Force Application with Concomitant Application of Electric Current - An Animal Study.
INTRODUCTION
The application of direct current can have a significant impact on the rate of tooth movement and surrounding periodontal ligament collagen turnover. This study aims to provide insight into the optimal characteristics of applied current to achieve enhanced tissue response.
METHOD
Eighteen male Wistar rats were divided into three groups (I, II, and III). Split mouth design was used, and each side was allocated into an experimental group or control group. Experimental sides of groups I, II, and III received 20, 10, and 15 μA of current (15 min, twice daily for 3 days). Both the experimental and control groups receive an orthodontic force via the NiTi closed coil spring. The amount of tooth movement was determined daily. Immunohistochemistry slides were scored using the immunoreactive scoring (IRS) system for collagen types I and III. One-way Analysis of Variance (ANOVA) and Tukey post hoc test were used to analyse the rate of tooth movement, while Mann-Whitney test was used to analyse IRS distribution between control and experimental groups.
RESULTS
Compared with the control group, there was a statistically significant difference in tooth movement in all the experimental groups, with group 3 showing the maximum rate on days 2 and 3. This was supported by immunoreactive scores for both collagen types I and III.
CONCLUSIONS
After 72 hours, the expression of collagen types 1 and 3 increased significantly for group III. This finding was in harmony with the rate of tooth movement, which was maximum for group 3 (15 μA) as compared to other groups.
Topics: Periodontal Ligament; Animals; Rats, Wistar; Tooth Movement Techniques; Male; Rats; Collagen Type I; Immunohistochemistry; Collagen Type III; Orthodontic Wires; Dental Alloys; Nickel; Stress, Mechanical; Titanium
PubMed: 38934753
DOI: 10.4103/ijdr.ijdr_905_22 -
Journal of Clinical Orthodontics : JCO May 2024
Topics: Humans; Orthodontic Wires; Orthodontic Appliance Design; Female; Tooth Movement Techniques; Dental Alloys; Malocclusion; Male; Adolescent
PubMed: 38917040
DOI: No ID Found -
Journal of Pharmacy & Bioallied Sciences Apr 2024Tooth movement in orthodontic therapy is connected to the frictional force that is created as the wire passes over the bracket. It is possible for teeth to move quickly...
Tooth movement in orthodontic therapy is connected to the frictional force that is created as the wire passes over the bracket. It is possible for teeth to move quickly when friction is at a minimum. Wires coated with nanoparticles have been found to reduce friction as a result of current developments in the orthodontics sector. Having an antimicrobial property is an added benefit. To reduce the friction generated by brackets, wires, and bands by lessening their cytotoxicity, this study examines the potential use of TiO2 nanoparticles in orthodontics. A monolayer of L929 was utilized in an indirect cytotoxicity test to evaluate the cytotoxicity of the coated orthodontic wire. The absence of reactive zones in our sample data demonstrates that TiO2 is not cytotoxic. Considering the results of our study, we conclude that TiO2 is secure for use as a coating for orthodontic devices.
PubMed: 38882869
DOI: 10.4103/jpbs.jpbs_824_23 -
Dento Maxillo Facial Radiology Jun 2024To evaluate magnetic susceptibility artefacts produced by orthodontic wires on MRI and the influence of wire properties and MRI image sequences on the magnitude of the...
OBJECTIVES
To evaluate magnetic susceptibility artefacts produced by orthodontic wires on MRI and the influence of wire properties and MRI image sequences on the magnitude of the artefact.
METHODS
Arch form orthodontic wires [four stainless steels (SS), one cobalt chromium (CC) alloy, 13 titanium (Ti) alloys] were embedded in a polyester phantom, and scanned using a 1.5-T superconducting magnet scanner with an eight-channel phased-array coil. All wires were scanned with T1-weighted spin echo (SE) and gradient echo (GRE) sequences according to the American Society for Testing and Materials (ASTM) F2119-07 standard. The phantom was also scanned other eight sequences. Artefacts were measured using the ASTM F2119-07 definition and OsiriX software. Artefact volume was analyzed according to metal composition, wire length, number of wires, wire thickness, and imaging sequence as factors.
RESULTS
With SE/GRE, black/white artefacts volumes from all SS wires were significantly larger than those produced by CC and Ti wires (P < 0.01). With the GRE, the black artefacts volume was highest with the SS wires. With the SE, the black artefacts volume was small, whereas white artefacts were noticeable. The cranio-caudal extent of the artefacts was significantly longer with SS wires (P < 0.01). Although a direct relationship of wire length, number of wires and wire thickness with artefact volume was noted, these factors did not influence artefact extension in the cranio-caudal direction.
CONCLUSIONS
Ferromagnetic/paramagnetic orthodontic wires create artefacts due to local alteration of magnetic field homogeneity. The SS-type wires produced the largest artefacts followed by CC and Ti.
PubMed: 38870528
DOI: 10.1093/dmfr/twae023 -
Medical Science Monitor : International... Jun 2024Orthodontic treatments, while essential for achieving optimal oral health, present challenges in infection control due to the propensity for bacterial adhesion and...
Orthodontic treatments, while essential for achieving optimal oral health, present challenges in infection control due to the propensity for bacterial adhesion and biofilm formation on orthodontic appliances. Silver-coated orthodontic materials have emerged as a promising solution, leveraging the potent antimicrobial properties of silver nanoparticles (AgNPs). Antibacterial coatings are used in orthodontics to prevent the formation of bacterial biofilms. This systematic review evaluated the literature on antimicrobial silver coatings on fixed orthodontic appliances, including archwires, brackets, and microimplants. Two evaluators, working independently, rigorously conducted a comprehensive search of various databases, including PubMed, PubMed Central, Embase, Scopus and Web of Science. This systematic review comprehensively examined in vitro studies investigating the antimicrobial efficacy of silver-coated orthodontic archwires, brackets, and microimplants. The review registered in PROSPERO CRD42024509189 synthesized findings from 18 diverse studies, revealing consistent and significant reductions in bacterial adhesion, biofilm formation, and colony counts with the incorporation of AgNPs. Key studies demonstrated the effectiveness of silver-coated archwires and brackets against common oral bacteria, such as Streptococcus mutans and Staphylococcus aureus. Microimplants coated with AgNPs also exhibited notable antimicrobial activity against a range of microorganisms. The systematic review revealed potential mechanisms underlying these antimicrobial effects, highlighted implications for infection prevention in orthodontic practice, and suggested future research avenues. Despite some study heterogeneity and limitations, the collective evidence supports the potential of silver-coated orthodontic materials in mitigating bacterial complications, emphasizing their relevance in advancing infection control measures in orthodontics.
Topics: Silver; Humans; Biofilms; Orthodontic Brackets; Metal Nanoparticles; Orthodontic Wires; Orthodontic Appliances, Fixed; Anti-Infective Agents; Coated Materials, Biocompatible; Anti-Bacterial Agents; Streptococcus mutans; Bacterial Adhesion; Staphylococcus aureus
PubMed: 38843112
DOI: 10.12659/MSM.944255 -
Clinical Oral Investigations May 2024To clinically compare the effects of broader archwires to standard archwires, using conventional brackets in both cases, on the transverse and incisor changes in... (Randomized Controlled Trial)
Randomized Controlled Trial Comparative Study
OBJECTIVES
To clinically compare the effects of broader archwires to standard archwires, using conventional brackets in both cases, on the transverse and incisor changes in maxillary and mandibular arches during leveling and alignment.
MATERIALS AND METHODS
Fifty-two patients presenting with crowding were allocated into two groups; one group received the broad Damon archwires while the other received standard 3M OrthoForm III Ovoid archwires. All participants were treated with conventional brackets using similar archwire sequences (0.014, 0.018, 0.016 × 0.022/0.016 × 0.025, 0.019 × 0.025 NiTi/CuNiTi archwires). Digital casts were obtained from alginate impressions before treatment (T0) and six weeks after inserting 0.019 × 0.025 NiTi archwires (T1). Pretreatment (T0) and post-alignment (T1) lateral cephalograms were obtained for each patient. The primary outcomes were the changes in the transverse arch dimensions and incisor inclination. The secondary outcomes were the horizontal and vertical linear changes in incisor position.
RESULTS
Complete data were collected for 47 patients. There was a significant increase in arch width during treatment within each group, except for upper inter-molar width in 3M group (P = 0.071). Damon wire induced a statistically significant increase in maxillary inter-second premolar width (P = 0.042), and mandibular inter-first premolar (P = 0.043), inter-second premolar (P = 0.008) and inter-molar widths (P = 0.033) compared to 3M group. The increase in incisor proclination and the linear change in incisor position were significant within each group, with less mandibular incisor proclination (P = 0.004) and horizontal advancement (P = 0.038) in the Damon group.
CONCLUSIONS
Damon archwires created a comparatively greater increase in the maxillary inter-second premolar width and the mandibular inter-first premolar, inter-second premolar, and inter-molar widths, and less proclination and horizontal advancement in mandibular incisors. The study provides invaluable evidence that using broad archwires with self-ligating brackets is the reason behind any greater expansion observed in this system rather than the unique mechanical and biological features exerted by the self-ligating system.
CLINICAL RELEVANCE
Our results suggest that Damon archwire might be a better alternative compared to the narrower standard archwires that are usually used with conventional brackets, especially in the mandibular arch, in cases where mild to moderate crowding is planned to be resolved with a non-extraction approach. However, as arch expansion in the absence of posterior crossbites raises the question of long-term stability, the reported advantage of the use of wide wires should be interpreted with caution and should be considered in the retention phase, bearing in mind that achieving a good post-treatment occlusion is important for enhancing post-treatment stability.
Topics: Humans; Orthodontic Wires; Female; Male; Incisor; Cephalometry; Malocclusion; Orthodontic Appliance Design; Adolescent; Orthodontic Brackets; Nickel; Dental Arch; Titanium; Treatment Outcome; Tooth Movement Techniques; Copper
PubMed: 38797781
DOI: 10.1007/s00784-024-05724-0 -
Journal of Orthodontic Science 2024White spot lesions (WSLs) refer to localized areas of hypo-mineralization limited to the enamel of the teeth surface, which is noticeable clinically to the naked eye on... (Review)
Review
White spot lesions (WSLs) refer to localized areas of hypo-mineralization limited to the enamel of the teeth surface, which is noticeable clinically to the naked eye on drying of the teeth. During fixed orthodontic treatment, it is very hard for the patient to maintain excellent oral hygiene as the brackets, bands, wires, elastics, and other appliances and attachments worn intra-orally provide a platform for food retention, plaque formation, and then colonization by acidogenic bacteria like and . This review aims to elaborate and focus on etiology, pathophysiology, diagnosis, treatment aspect, and future scope for research about the WSLs occurring due to fixed orthodontic treatment.
PubMed: 38784071
DOI: 10.4103/jos.jos_205_23 -
Cureus Apr 2024Robotics has various applications in dentistry, particularly in orthodontics, although the potential use of these technologies is not yet clear. This review aims to... (Review)
Review
Robotics has various applications in dentistry, particularly in orthodontics, although the potential use of these technologies is not yet clear. This review aims to summarize the application of robotics in orthodontics and clarify its function and scope in clinical practice. Original articles addressing the application of robotics in any area of orthodontic practice were included, and review articles were excluded. PubMed, Google Scholar, Scopus, and DOAJ were searched from June to August 2023. The risk of bias was established using the risk of bias in non-randomized studies (ROBINS) and certainty assessment tools following the grading of recommendations, assessment, development, and evaluation (GRADE) guidelines. A narrative synthesis of the data was generated and presented according to its application in surgical and non-surgical orthodontics. The search retrieved 2,106 articles, of which 16 articles were selected for final data synthesis of research conducted between 2011 and 2023 in Asia, Europe, and North America. The application of robotics in surgical orthodontics helps guide orthognathic surgeries by reducing the margin of error, but it does not replace the work of a clinician. In non-surgical orthodontics, robotics assists in performing customized bending of orthodontic wires and simulating orthodontic movements, but its application is expensive. The articles collected for this synthesis exhibited a low risk of bias and high certainty, and the results indicated that the advantages of the application of robotics in orthodontics outweigh the disadvantages. This project was self-financed, and a previous protocol was registered at the PROSPERO site (registration number: CRD42023463531).
PubMed: 38765377
DOI: 10.7759/cureus.58555 -
Journal of Clinical Orthodontics : JCO Apr 2024
Topics: Orthodontic Brackets; Humans; Orthodontic Appliance Design; Orthodontic Wires
PubMed: 38754443
DOI: No ID Found -
BMC Oral Health May 2024Alterations in the mechanical properties of the materials utilized in orthodontic appliances could affect the working properties of the appliances, thereby affecting... (Randomized Controlled Trial)
Randomized Controlled Trial Comparative Study
BACKGROUND
Alterations in the mechanical properties of the materials utilized in orthodontic appliances could affect the working properties of the appliances, thereby affecting clinical progress and outcome. Numerous studies have confirmed the correlation between alloy corrosion and raised surface roughness, which has a direct impact on the working characteristics of orthodontic archwires.
METHODS
Thirty nickel-titanium (NiTi) orthodontic archwires were utilized in this study. Patients were randomly selected and allocated into three groups according to the randomization plan; (The control group): subjects practiced regular oral hygiene; (The fluoride group): subjects used fluoride for intensive prophylaxis; (The chlorhexidine group): subjects used chlorhexidine. Representative samples were evaluated by SEM, and then SEM images with high resolution were examined using Image J software to determine the surface roughness and obtain the results for further statistical analysis.
RESULTS
Our findings indicated a significant difference was found between the three groups regarding the anterior and posterior parts between the control and the two other groups and a non-significant difference between NaF and CHX groups. Overall, the p-value for group comparisons was 0.000 for both parts, indicating a highly significant difference especially between the control and NaF groups.
CONCLUSION
Mouthwashes containing sodium fluoride demonstrated more significant surface alterations than the control and CHX groups and should be prescribed in accordance with orthodontic materials to reduce side effects.
Topics: Humans; Sodium Fluoride; Chlorhexidine; Corrosion; Surface Properties; Orthodontic Wires; Dental Alloys; Nickel; Alloys; Microscopy, Electron, Scanning; Titanium; Cariostatic Agents; Male; Female; Young Adult; Mouthwashes; Image Processing, Computer-Assisted; Adolescent; Adult; Oral Hygiene
PubMed: 38745154