Annals of the Academy of Medicine,... May 2024
Topics: Humans; Bioprosthesis; Transcatheter Aortic Valve Replacement; Heart Valve Prosthesis; Prosthesis Failure; Aortic Valve Stenosis; Aortic Valve; Male; Aged; Female; Aged, 80 and over
PubMed: 38920226
DOI: 10.47102/annals-acadmedsg.2023413 -
Indian Journal of Thoracic and... Jul 2024A 79-year-old man underwent bioprosthetic valve replacement for aortic regurgitation 10 years previously (Carpentier-Edwards PERIMOUNT Magna Ease, 21 mm; Edwards...
A 79-year-old man underwent bioprosthetic valve replacement for aortic regurgitation 10 years previously (Carpentier-Edwards PERIMOUNT Magna Ease, 21 mm; Edwards Lifesciences, Irvine, CA, USA). The indexed effective orifice area decreased to 0.422 cm/m, and heart failure symptoms appeared. The patient underwent aortic valve replacement through a redo median sternotomy. A perivalvular leak was observed on transesophageal echocardiography at the time of weaning from cardiopulmonary bypass. The patient was judged to have a leak characteristic of bioprosthetic valves and was monitored closely. Postoperative echocardiography showed that the perivalvular leak had decreased to a trivial level, indicating that the intraoperative decision had been correct. We report this case because such intraoperative judgments are difficult to make.
PubMed: 38919181
DOI: 10.1007/s12055-023-01681-7 -
Journal of Cardiothoracic Surgery Jun 2024Alkaptonuria is a rare congenital metabolic disorder characterized by homogentisic acid accumulation in body cartilage and connective tissues due to a deficient...
BACKGROUND
Alkaptonuria is a rare congenital metabolic disorder characterized by homogentisic acid accumulation in body cartilage and connective tissues due to a deficient homogentisic acid dioxygenase enzyme. This disorder manifests in various clinical symptoms, including spondyloarthropathy, ocular and dermal pigmentation, genitourinary tract obstruction by ochronosis stones, and cardiovascular system involvement. Cardiac ochronosis is a rare manifestation of alkaptonuria that may present as aortic stenosis, sometimes accompanied by other cardiovascular complications.
CASE PRESENTATION
We report an unexpected case of ochronosis diagnosed during cardiac surgery. Due to the fragile, thin, and atheromatous nature of the ascending aorta in patients with ochronosis, we opted for a sutureless aortic valve replacement procedure. This approach appears to be more suitable for patients with ochronosis.
CONCLUSIONS
Although cardiac ochronosis is rare, surgeons should remain vigilant and consider the possibility of this condition when examining patients with aortic valve stenosis, paying close attention to the clinical manifestations of alkaptonuria.
Topics: Humans; Ochronosis; Aortic Valve Stenosis; Alkaptonuria; Heart Valve Prosthesis Implantation; Aortic Valve; Male; Sutureless Surgical Procedures; Female; Aged
PubMed: 38918861
DOI: 10.1186/s13019-024-02834-4 -
European Journal of Cardio-thoracic... Jun 2024Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain.
OBJECTIVES
Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain.
METHODS
A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed.
RESULTS
The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20-0.94, P = 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60-1.09, P = 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63-1.07, P = 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47-1.45, P = 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P = 0.032).
CONCLUSIONS
Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis.
Topics: Humans; Male; Titanium; Female; Heart Valve Prosthesis Implantation; Aged; Aortic Valve; Endocarditis; Suture Techniques; Retrospective Studies; Middle Aged; Heart Valve Prosthesis
PubMed: 38913864
DOI: 10.1093/ejcts/ezae236 -
JACC. Case Reports Jul 2024An 82-year-old patient experienced symptomatic intra-prosthetic aortic regurgitation 5 years after self-expandable transcatheter heart valve (THV) implantation....
An 82-year-old patient experienced symptomatic intra-prosthetic aortic regurgitation 5 years after self-expandable transcatheter heart valve (THV) implantation. Redo-transcatheter aortic valve replacement was initially considered at high risk of coronary obstruction. Using a systematic computed tomography-based approach planning a low implantation with a SAPIEN 3 Ultra THV, we effectively mitigated risks.
PubMed: 38912321
DOI: 10.1016/j.jaccas.2024.102388 -
PeerJ 2024The incidence of perioperative neurocognitive disorders (PND) is high, especially after cardiac surgeries, and the underlying mechanisms remain elusive. Here, we... (Observational Study)
Observational Study
OBJECTIVE
The incidence of perioperative neurocognitive disorders (PND) is high, especially after cardiac surgeries, and the underlying mechanisms remain elusive. Here, we conducted a prospective observational study to observe serum proteomics differences in PND patients after cardiac valve replacement surgery.
METHODS
Two hundred and twenty-six patients who underwent cardiac valve surgery were included. They were categorized based on scoring into non-PND group (group non-P) and PND group (group P'). The risk factors associated with PND were analyzed. These patients were further divided into group C and group P by propensity score matching (PSM) to investigate the serum proteome related to the PND by serum proteomics.
RESULTS
The postoperative 6-week incidence of PND was 16.8%. Risk factors for PND include age, chronic illness, sufentanil dosage, and time of cardiopulmonary bypass (CPB). Proteomics identified 31 down-regulated proteins and six up-regulated proteins. Finally, GSTO1, IDH1, CAT, and PFN1 were found to be associated with PND.
CONCLUSION
The occurrence of PND can impact some oxidative stress proteins. This study provided data for future studies about PND to general anaesthesia and surgeries.
Topics: Humans; Male; Prospective Studies; Female; Proteomics; Middle Aged; Heart Valve Prosthesis Implantation; Risk Factors; Cognitive Dysfunction; Aged; Postoperative Complications; Postoperative Cognitive Complications; Incidence; Propensity Score; Adult
PubMed: 38912047
DOI: 10.7717/peerj.17536 -
Cardiology Clinics Aug 2024Atrioventricular (AV) valve disease is a major burden in our Indian subcontinent, where rheumatic heart disease is still prevalent, when compared to the Western world,... (Review)
Review
Atrioventricular (AV) valve disease is a major burden in our Indian subcontinent, where rheumatic heart disease is still prevalent, when compared to the Western world, where degenerative heart disease is more prevalent. Worldwide, nearly 300,000 valve replacements are done every year but not without complications. These challenges can be multidimensional and multiscalar with the macroscopic and microscopic properties of the native patient tissue interacting with the mechanical and bioprosthetic heart valves and rings. Understanding the complex and variable anatomy of the AV valves is essential to know the exact pathophysiology of the disease and to decide the treatment of choice.
Topics: Humans; Heart Valve Prosthesis Implantation; Heart Valve Prosthesis; Prosthesis Design; Heart Valve Diseases; Bioprosthesis; Tricuspid Valve; Mitral Valve
PubMed: 38910024
DOI: 10.1016/j.ccl.2024.04.001 -
Cardiology Clinics Aug 2024Self-expanding valves (SEV) and balloon-expandable valves (BEV) for transcatheter aortic valve implantation (TAVI) have their own features. There is a growing interest... (Meta-Analysis)
Meta-Analysis Review
Self-expanding valves (SEV) and balloon-expandable valves (BEV) for transcatheter aortic valve implantation (TAVI) have their own features. There is a growing interest in long-term outcomes with the adoption of lifetime management in younger patients. To evaluate late outcomes in TAVI with SEV versus BEV, we performed a study-level meta-analysis of reconstructed time-to-event data published by May 31, 2023. We found no statistically significant difference in all-cause death after TAVI with SEV versus BEV. Randomized controlled trials are warranted to validate our results.
Topics: Humans; Transcatheter Aortic Valve Replacement; Aortic Valve Stenosis; Heart Valve Prosthesis; Prosthesis Design; Aortic Valve; Treatment Outcome; Time Factors
PubMed: 38910022
DOI: 10.1016/j.ccl.2024.02.017 -
Journal of Cardiothoracic Surgery Jun 2024Pseudoaneurysm of the mitral-aortic intervalvular fibrosa (PMAIF) is a rare complication of infective endocarditis or aortic valve surgery. Surgical treatment is... (Review)
Review
BACKGROUND
Pseudoaneurysm of the mitral-aortic intervalvular fibrosa (PMAIF) is a rare complication of infective endocarditis or aortic valve surgery. Surgical treatment is suggested, but the long-term follow-up of conservative management remains unclear.
CASE PRESENTATION
A 33-year follow-up of a patient who developed PMAIF six years after aortic valve replacement is reported. The patient presented to our center with dyspnea, and the echocardiography revealed an ejection fraction of 20% and a PMAIF measuring 7 × 10 mm. Despite being advised to undergo surgery, the patient declined due to fear of surgical outcomes. Consequently, conservative treatment with close observation but without surgery was initiated. During the 33-year follow-up period, the patient did not experience any adverse health effects.
CONCLUSION
Surgical intervention should be considered whenever the PMAIF is diagnosed. However, in any case that the surgery was not applicable, conservative management might lead to long-term survival, based on this and similar case reports in the literature.
Topics: Humans; Aneurysm, False; Mitral Valve; Aortic Valve; Male; Follow-Up Studies; Heart Aneurysm; Echocardiography; Heart Valve Prosthesis Implantation; Middle Aged
PubMed: 38907323
DOI: 10.1186/s13019-024-02885-7 -
Journal of Cardiothoracic Surgery Jun 2024Observational studies have shown reduced perioperative bleeding in patients undergoing minimally invasive, compared with full sternotomy, aortic valve replacement. Data... (Randomized Controlled Trial)
Randomized Controlled Trial Comparative Study
BACKGROUND
Observational studies have shown reduced perioperative bleeding in patients undergoing minimally invasive, compared with full sternotomy, aortic valve replacement. Data from randomized trials are conflicting.
METHODS
This was a Swedish single center study where adult patients with aortic stenosis, 100 patients were randomly assigned in a 1:1 ratio to undergo either minimally invasive (ministernotomy) or full sternotomy aortic valve replacement. The primary outcome was severe or massive bleeding defined by the Universal Definition of Perioperative Bleeding in adult cardiac surgery (UDPB). Secondary outcomes included blood product transfusions, chest tube output, re-exploration for bleeding, and several other clinically relevant events.
RESULTS
Out of 100 patients, three patients randomized to ministernotomy were intraoperatively converted to full sternotomy (none was bleeding-related). Three patients (6%) in the full sternotomy group and 3 patients (6%) in the ministernotomy group suffered severe or massive postoperative bleeding according to the UDPB definition (p = 1.00). Mean chest tube output during the first 12 postoperative hours was 350 (standard deviation (SD) 220) ml in the full sternotomy group and 270 (SD 190) ml in the ministernotomy group (p = 0.08). 28% of patients in the full sternotomy group and 36% of patients in the ministernotomy group received at least one packed red blood cells transfusion (p = 0.39). Two patients in each group (4%) underwent re-exploration for bleeding.
CONCLUSIONS
Minimally invasive aortic valve replacement did not result in less bleeding-related outcomes compared to full sternotomy.
CLINICAL TRIAL REGISTRATION
http://www.
CLINICALTRIALS
gov . Unique identifier: NCT02272621.
Topics: Humans; Male; Female; Minimally Invasive Surgical Procedures; Heart Valve Prosthesis Implantation; Aged; Sternotomy; Aortic Valve Stenosis; Aortic Valve; Postoperative Hemorrhage; Aged, 80 and over; Sweden; Middle Aged; Treatment Outcome; Blood Loss, Surgical
PubMed: 38907320
DOI: 10.1186/s13019-024-02667-1