JACC. Cardiovascular Interventions Jun 2024
Topics: Humans; Transcatheter Aortic Valve Replacement; Cardiac Pacing, Artificial; Pacemaker, Artificial; Treatment Outcome; Time Factors; Aortic Valve Stenosis; Risk Factors; Heart Rate; Aortic Valve; Heart Valve Prosthesis; Arrhythmias, Cardiac
PubMed: 38866456
DOI: 10.1016/j.jcin.2024.04.018 -
JACC. Cardiovascular Interventions Jun 2024Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates,... (Observational Study)
Observational Study
BACKGROUND
Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV).
OBJECTIVES
The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV.
METHODS
The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR.
RESULTS
Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02).
CONCLUSIONS
PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.
Topics: Humans; Registries; Male; Female; Transcatheter Aortic Valve Replacement; Pacemaker, Artificial; Risk Factors; Aged; Time Factors; Aged, 80 and over; Treatment Outcome; Cardiac Pacing, Artificial; Heart Valve Prosthesis; Aortic Valve Stenosis; Aortic Valve; Prosthesis Design; Risk Assessment; Arrhythmias, Cardiac; United States
PubMed: 38866455
DOI: 10.1016/j.jcin.2024.03.034 -
Catheterization and Cardiovascular... Jun 2024Challenging anatomies and comorbidities have impact on success in transcatheter aortic valve replacement (TAVR). There is controversy whether the extent of the aortic...
BACKGROUND
Challenging anatomies and comorbidities have impact on success in transcatheter aortic valve replacement (TAVR). There is controversy whether the extent of the aortic angle (AA) has an impact on procedural outcomes. Matched comparative outcome data of new generation transcatheter heart valves (THVs) in horizontal aorta (HA) are scarce.
METHODS
A total of 1582 patients with severe native aortic stenosis (AS) treated with the SAPIEN3 Ultra (Ultra; n = 526) or ACURATE Neo2 (Neo2; n = 1056) THVs from January 2017 to January 2023 were analyzed. Patients with non-horizontal aortas (AA < 51.7°, n = 841) were excluded. The population was matched by 1-to-1 nearest-neighbor matching (Ultra, n = 246; Neo2, n = 246). Clinical and procedural outcome were evaluated according to VARC-3 recommendations.
RESULTS
Technical success (93.1% vs. 94.7%, p = 0.572) was high after Ultra and Neo2. Device success (80.5% vs. 89.8%, p = 0.05) was inferior with Ultra. Neo2 reveals superior hemodynamic properties with lower rate of severe prosthesis patient mismatch (12.0% vs. 3.7%, p = 0.001) and elevated gradients ( 20 mmHg: 11.9% vs. 1.7%, p < 0.001). Ultra showed a lower rate of relevant paravalvular regurgitation ( mild paravalvular regurgitation or Valve-in-Valve due to paravalvular regurgitation: 0.0% vs. 3.7%, p = 0.004). The rate of procedural bailout maneuvers (0.8% vs. 0.4%, p = 1.000) and thirty-day all-cause mortality (1.3% vs. 2.2%, p = 0.496) was similar.
CONCLUSION
Transfemoral TAVR in patients with severe aortic stenosis and HA, using the balloon expandable Sapien3 Ultra and self-expanding ACURATE Neo2 prosthesis, is feasible and safe. Therefore, valve selection between these platforms should be made irrespective of the aortic angle by a team experienced with both valves based on their specific advantages. Large, randomized trials in this sub-group of patients would be necessary to compare long term outcomes.
PubMed: 38860614
DOI: 10.1002/ccd.31094 -
BMJ Open Jun 2024Aortic stenosis (AS) is common affecting >13% of adults over the age of 75 years. In people who develop symptoms, without valve replacement, prognosis is dismal with...
Pilot study to evaluate the use of remote patient monitoring to guide the timing of valve intervention in patients with severe asymptomatic aortic stenosis (APRAISE-AS): study protocol for a randomised controlled trial delivered in two tertiary cardiac centres in the UK.
INTRODUCTION
Aortic stenosis (AS) is common affecting >13% of adults over the age of 75 years. In people who develop symptoms, without valve replacement, prognosis is dismal with mortality as high as 50% at 1 year. In asymptomatic patients, the timing of valve intervention is less well defined and a strategy of watchful waiting is recommended. Many, however, may develop symptoms and attribute this to age related decline, rather than worsening AS. Timely intervention in asymptomatic severe AS is critical, since delayed intervention often results in poor outcomes. Proactive surveillance of symptoms, quality of life and functional capacity should enable timely identification of people who will benefit from aortic valve replacement. There are no data however, to support the clinical and cost effectiveness of such an approach in a healthcare setting in the UK. The aim of this pilot trial is to test the feasibility of a full-scale randomised controlled trial (RCT) to determine the utility of proactive surveillance in people with asymptomatic severe AS to guide the timing of intervention.
METHODS AND ANALYSIS
APRAISE-AS is a multi-centre, non-blinded, two-arm, parallel group randomised controlled trial of up to 66 participants aged >18 years with asymptomatic severe AS. Participants will be randomised to either standard care or standard care supplemented with the APRAISE-AS intervention. Primary outcomes will capture; adherence to and participant acceptability of the intervention, recruitment and retention rates, and completeness of data collection. The findings will be used to inform the sample size and most appropriate outcome measure(s) for a full-scale RCT and health economic evaluation.
ETHICS AND DISSEMINATION
Ethical approval was granted by the Black Country REC, reference: 22/WM/0214. Results will be submitted for publication in peer-reviewed journals and disseminated at local, regional and national meetings where appropriate.
TRIAL REGISTRATION NUMBER
ISRCTN19413194 registered on 14.07.2023.
Topics: Humans; Aortic Valve Stenosis; Pilot Projects; United Kingdom; Quality of Life; Randomized Controlled Trials as Topic; Asymptomatic Diseases; Multicenter Studies as Topic; Aged; Tertiary Care Centers; Telemedicine; Heart Valve Prosthesis Implantation; Watchful Waiting; Time-to-Treatment; Cost-Benefit Analysis
PubMed: 38858149
DOI: 10.1136/bmjopen-2024-086587 -
BJR Case Reports May 2024Q fever is an epidemic disease caused by the infection. It can manifest clinically as an acute or chronic disease, with chronic infections being more common. Q fever...
Q fever is an epidemic disease caused by the infection. It can manifest clinically as an acute or chronic disease, with chronic infections being more common. Q fever endocarditis is the most common manifestation of chronic infection and usually occurs in patients with previous valvular heart disease like in our present study, a case of Q fever endocarditis that occurred in background of tetralogy of Fallot surgical repair. However, Q fever endocarditis is difficult to diagnose clinically and may lead to very serious or even life-threatening outcomes if not diagnosed promptly. In the present study, accurate diagnosis and treatment were achieved by 18F-FDG PET/CT combined with detection of the Q fever serological antibodies.
PubMed: 38854890
DOI: 10.1093/bjrcr/uaae017 -
International Journal of Cardiology Jun 2024Patients with a small aortic annulus (SAA) undergoing aortic valve replacement are at increased risk of patient-prosthesis mismatch (PPM), which adversely affects...
INTRODUCTION
Patients with a small aortic annulus (SAA) undergoing aortic valve replacement are at increased risk of patient-prosthesis mismatch (PPM), which adversely affects outcomes. Transcatheter aortic valve replacement (TAVR) has shown promise in mitigating PPM compared to surgical aortic valve replacement (SAVR).
METHODS
We conducted a systematic review and meta-analysis following PRISMA guidelines to compare clinical outcomes, mortality, and PPM between SAA patients undergoing TAVR and SAVR. Eligible studies were identified through comprehensive literature searches and assessed for quality and relevance.
RESULTS
Nine studies with a total of 2476 patients were included. There was no significant difference in 30-day Mortality between TAVR vs SAVR groups (OR = 0.65, 95% CI [ 0.09-4.61], P = 0.22). There was no difference between both groups regarding myocardial infarction at 30 days (OR = 0.63, 95% CI [0.1-3.89], P = 0.62). TAVR was associated with a significantly lower 30-day major bleeding and 2-year major bleeding, Pooled studies were homogeneous (OR = 0.44, 95% CI [0.31-0.64], P < 0.01, I2 = 0, P = 0.89), (OR = 0.4 ,95% CI [0.21-0.77], P = 0.03, I2 = 0%, P = 0.62) respectively. TAVR was associated with a lower rate of moderate PPM (OR = 0.6, 95% CI [ 0.44-0.84], p value = 0.01, i2 = 0%, p value = 0.44). The overall effect estimate did not favor any of the two groups regarding short-term Mild AR (OR = 5.44, 95% CI [1.02-28.91], P = 0.05) and Moderate/severe AR (OR = 4.08, 95% CI [ 0.79-21.02], P = 0.08, I2 = 0%, P = 0.59).
CONCLUSION
Our findings suggest that both TAVR and SAVR are viable options for treating AS in patients with a small aortic annulus. TAVR offers advantages in reducing PPM and major bleeding, while SAVR performs better in terms of pacemaker implantation. Future studies should focus on comparing newer generation TAVR techniques and devices with SAVR. Consideration of patient characteristics is crucial in selecting the optimal treatment approach for AS.
PubMed: 38851542
DOI: 10.1016/j.ijcard.2024.132243 -
The Annals of Thoracic Surgery Jun 2024Patient-prosthesis mismatch (PPM) after aortic valve replacement potentially affects the outcome after the operation. This study sought to determine whether PPM has an...
BACKGROUND
Patient-prosthesis mismatch (PPM) after aortic valve replacement potentially affects the outcome after the operation. This study sought to determine whether PPM has an impact on long-term mortality and reoperation rates.
METHODS
We included 645 patients who underwent biologic aortic valve replacement between 2000 and 2007. Based on echocardiographic examinations at postoperative month 6, the incidence of PPM was determined according to an indexed effective orifice area <0.85 cm/m. Survival and reoperation status were analyzed during 15 years of follow-up.
RESULTS
PPM was present in 256 patients (40%), of whom 175 had moderate PPM and 81 had severe PPM. In multivariable adjusted analysis, survival was not statistically significantly impaired in patients with moderate PPM compared with patients with no PPM, whereas patients with severe PPM showed a marginally significant impairment of survival (hazard ratio [HR], 1.40; 95% CI, 0.99-1.97; P = .054). Risk factors for survival were higher age (HR, 1.12; 95% CI, 1.10-1.14; P < .001), arterial hypertension (HR, 1.78; 95% CI, 1.38-2.31; P < .001), and diabetes mellitus (HR, 1.67; 95% CI, 1.31-2.14; P < .001). In patients with no, moderate, and severe PPM, there were 10.1, 8.5, and 14.8 events of reoperation/1000 patient-years, respectively. The corresponding 10-year cumulative incidence of reoperation was 8.3%, 6.7%, and 12.1%, respectively. In multivariable adjusted analysis, PPM category was not significantly associated with the risk of reoperation (P > .2).
CONCLUSIONS
In our study with directly measured effective orifice area, PPM was only marginally related to long-term survival and was not statistically significantly associated with the risk of reintervention.
PubMed: 38851414
DOI: 10.1016/j.athoracsur.2024.05.025 -
American Heart Journal Jun 2024It remains unclear today whether risk scores created specifically to predict early mortality after cardiac operations for infective endocarditis (IE) outperform or not...
BACKGROUND
It remains unclear today whether risk scores created specifically to predict early mortality after cardiac operations for infective endocarditis (IE) outperform or not the European System for Cardiac Operative Risk Evaluation II (EuroSCORE II).
METHODS
Perioperative data and outcomes from a European multicenter series of patients undergoing surgery for definite IE were retrospectively reviewed. Only the cases with known pathogen and without missing values for all considered variables were retained for analyses. A comparative validation of EuroSCORE II and five specific risk scores for early mortality after surgery for IE - (1) STS-IE (Society of Thoracic Surgeons for IE); (2) PALSUSE (Prosthetic valve, Age ≥70, Large intra-cardiac destruction, Staphylococcus spp, Urgent surgery, Sex (female), EuroSCORE ≥10); (3) ANCLA (Anemia, New York Heart Association class IV, Critical state, Large intra-cardiac destruction, surgery on thoracic Aorta); (4) AEPEI II (Association pour l'Étude et la Prévention de l'Endocardite Infectieuse II); (5) APORTEI (Análisis de los factores PROnósticos en el Tratamiento quirúrgico de la Endocarditis Infecciosa) - was carried out using calibration plot and receiver-operating characteristic curve analysis. Areas under the curve (AUCs) were compared 1:1 according to the Hanley-McNeil's method. The agreement between APORTEI score and EuroSCORE II of the 30-day mortality prediction after surgery was also appraised.
RESULTS
A total of 1,012 patients from five European university-affiliated centers underwent 1,036 cardiac operations, with a 30-day mortality after surgery of 9.7%. All IE-specific risk scores considered achieved better results than EuroSCORE II in terms of calibration; AEPEI II and APORTEI score showed the best performances. Despite poor calibration, EuroSCORE II overcame in discrimination every specific risk score (AUC, 0.751 vs. 0.693 or less, p=0.01 or less). For a higher/lesser than 20% expected mortality, the agreement of prediction between APORTEI score and EuroSCORE II was 86%.
CONCLUSION
EuroSCORE II discrimination for 30-day mortality after surgery for IE was higher than five established IE-specific risk scores. AEPEI II and APORTEI score showed the best results in terms of calibration.
PubMed: 38848985
DOI: 10.1016/j.ahj.2024.05.021 -
Cardiology in ReviewCalcified aortic stenosis (AS) is one of the most common valvular heart diseases worldwide, characterized by progressive fibrocalcific remodeling and thickening of the... (Review)
Review
Calcified aortic stenosis (AS) is one of the most common valvular heart diseases worldwide, characterized by progressive fibrocalcific remodeling and thickening of the leaflets, which ultimately leads to obstruction of blood flow. Its pathobiology is an active and complicated process, involving endothelial cell dysfunction, lipoprotein deposition and oxidation, chronic inflammation, phenotypic transformation of valve interstitial cells, neovascularization, and intravalvular hemorrhage. To date, no targeted drug has been proven to slow down or prevent disease progression. Aortic valve replacement is still the optimal treatment of AS. This article reviews the etiology, diagnosis, and management of calcified aortic stenosis and proposes novel potential therapeutic targets.
Topics: Humans; Aortic Valve Stenosis; Calcinosis; Aortic Valve; Heart Valve Prosthesis Implantation
PubMed: 38848535
DOI: 10.1097/CRD.0000000000000510