-
Surgical and Radiologic Anatomy : SRA Jun 2024Ultrasonography (US) has become an essential tool for guiding botulinum neurotoxin (BoNT) injections in facial muscles, enhancing precision and safety. This narrative... (Review)
Review
INTRODUCTION
Ultrasonography (US) has become an essential tool for guiding botulinum neurotoxin (BoNT) injections in facial muscles, enhancing precision and safety. This narrative review explores the role of US in BoNT administration, particularly in complex anatomical regions, highlighting its impact on treatment customization, real-time visualization, and complication reduction.
MATERIALS AND METHODS
A comprehensive literature search was conducted using PubMed, MEDLINE, Embase, and Cochrane Library for articles published from January 2018 to December 2023. Search terms included "Botulinum neurotoxin," "facial anatomy," "ultrasonography guided injection," and "facial muscle sonoanatomy." Studies focusing on US-guided BoNT injections in facial muscles were included. Data extraction and synthesis were performed independently by two reviewers, focusing on study design, ultrasonography techniques, outcomes, and conclusions.
RESULTS
The review found that US guidance significantly enhances the precision of BoNT injections by providing real-time visualization of facial muscles and blood vessels, thereby reducing the risk of adverse events. US enables tailored injection strategies, ensuring symmetrical facial expressions and minimizing over-treatment. The technique also offers immediate feedback, allowing for on-the-spot adjustments to improve treatment efficacy and safety. However, the review identified limitations, including potential selection bias and variability in US techniques across different studies.
CONCLUSION
US guidance for BoNT injections into facial muscles offers substantial benefits in terms of precision, safety, and treatment customization. Despite the identified limitations, the integration of US into clinical practice is poised to enhance patient outcomes in aesthetic and therapeutic procedures. Further research is needed to standardize US techniques and broaden the inclusivity of studies to validate these findings comprehensively.
PubMed: 38942935
DOI: 10.1007/s00276-024-03429-3 -
Scientific Reports Jun 2024Self-reported shorter/longer sleep duration, insomnia, and evening preference are associated with hyperglycaemia in observational analyses, with similar observations in...
Self-reported shorter/longer sleep duration, insomnia, and evening preference are associated with hyperglycaemia in observational analyses, with similar observations in small studies using accelerometer-derived sleep traits. Mendelian randomization (MR) studies support an effect of self-reported insomnia, but not others, on glycated haemoglobin (HbA1c). To explore potential effects, we used MR methods to assess effects of accelerometer-derived sleep traits (duration, mid-point least active 5-h, mid-point most active 10-h, sleep fragmentation, and efficiency) on HbA1c/glucose in European adults from the UK Biobank (UKB) (n = 73,797) and the MAGIC consortium (n = 146,806). Cross-trait linkage disequilibrium score regression was applied to determine genetic correlations across accelerometer-derived, self-reported sleep traits, and HbA1c/glucose. We found no causal effect of any accelerometer-derived sleep trait on HbA1c or glucose. Similar MR results for self-reported sleep traits in the UKB sub-sample with accelerometer-derived measures suggested our results were not explained by selection bias. Phenotypic and genetic correlation analyses suggested complex relationships between self-reported and accelerometer-derived traits indicating that they may reflect different types of exposure. These findings suggested accelerometer-derived sleep traits do not affect HbA1c. Accelerometer-derived measures of sleep duration and quality might not simply be 'objective' measures of self-reported sleep duration and insomnia, but rather captured different sleep characteristics.
Topics: Humans; Mendelian Randomization Analysis; Glycated Hemoglobin; Accelerometry; Sleep; Blood Glucose; Male; Female; Middle Aged; Adult; Self Report; Aged; Sleep Initiation and Maintenance Disorders
PubMed: 38942746
DOI: 10.1038/s41598-024-58007-9 -
Integrative and Comparative Biology Jun 2024To humans, the diverse array of display behaviors that animals use for communication can easily seem peculiar or bizarre. While ample research delves into the...
To humans, the diverse array of display behaviors that animals use for communication can easily seem peculiar or bizarre. While ample research delves into the evolutionary principles that shape these signals' effectiveness, little attention is paid to evolutionary patterning of signal design across taxa, particularly when it comes to the potential convergent evolution of many elaborate behavioral displays. By taking a mechanistic perspective, we explore the physiological and neurobiological mechanisms that likely influence the evolution of communication signals, emphasizing the utilization of pre-existing structures over novel adaptations. Central to this investigation are the concepts of perceptual bias and ritualization, which we propose contribute to the convergence of elaborate display designs across species. Perceptual bias explains a phenomenon where pre-existing perceptual systems of receivers, used for innate behaviors such as food and predator recognition, select for certain traits of a communication signal from a signaler. Ritualization occurs when traits with no functional role in communication are co-opted through selection and transformed into a new communicative signal. Importantly, susceptibility for ritualization can be brought about through physiological modifications that occurred early in evolutionary time. In this way, perceptual bias can be a selective force that causes the co-option of non-communicative traits into a new communication signal through ritualization involving pre-existing modifications to physiological systems. If the perceptual bias, non-communicative signal, and physiological modifications that increase susceptibility to ritualization are highly conserved, then we may see the convergent evolution of the new communication signal with unrelated taxa facing similar sensory constraints. We explore this idea here using the foot-flagging frog system as a theoretical case study.
PubMed: 38942486
DOI: 10.1093/icb/icae091 -
Archives of Physical Medicine and... Jun 2024This study aimed to assess the effectiveness of exercise therapy for Axial spondyloarthritis (axSpA) patients. (Review)
Review
OBJECTIVE
This study aimed to assess the effectiveness of exercise therapy for Axial spondyloarthritis (axSpA) patients.
DATA SOURCES
From the database inception to March 2024, we searched PubMed (via Medline), Cochrane Library, Embase, Web of Science, Scopus, and SPORTDiscus for all relevant publications without any language restriction.
STUDY SELECTION
We included randomized controlled trials (RCTs) for axSpA patients in which at least one group received exercise therapy.
DATA EXTRACTION
Two independent reviewers assessed the quality of the literature using the Cochrane Collaboration Risk of Bias Tool 2.0. The outcomes were ankylosing spondylitis (AS) disease activity score (ASDAS), Bath AS disease activity index (BASDAI), Bath AS functional index (BASFI), Bath AS metrology index (BASMI), 6-minute walk distance (6MWT), Chest expansion capacity, Peak oxygen consumption (VOpeak), pain, fatigue, C-reactive protein (CRP), and Eythrocyte sedimentation rate (ESR).
DATA SYNTHESIS
A total of 20 RCTs, including 1,670 patients, were included in this study. Compared with the control group, exercise therapy improved BASFI (weighted mean difference [WMD]: -0.49, 95% confidence interval [CI]: -0.65 to -0.32, I= 3.4%, P=0.414), BASMI (WMD: -0.49, 95% CI: -0.87 to -0.11, I= 71.9%, P=0.679), BASDAI (WMD: -0.78, 95% CI: -1.08, -0.47, I=55.9%, P=0.021), ASDAS (WMD: -0.44, 95% CI: -0.64 to -0.24, I =0.0%, P=0.424), VOpeak (WMD: 3.16, 95% CI: 1.37 to 4.94, I=0.0%, P=0.873), 6MWT (WMD: 27.64, 95% CI: 12.04 to 43.24, I= 0.0%, P=0.922), Pain (standardized mean difference [SMD]: -0.47, 95% CI: -0.74 to -0.21, I= 66.0%, P=0.046) and Fatigue (SMD: -0.49, 95% CI: -0.71 to -0.27, I= 0.0%, P=0.446). However, no significant benefit was found in Chest expansion, CRP, and ESR outcomes.
CONCLUSIONS
Exercise therapy is an effective strategy for improving disease control and symptom relief in axSpA.
PubMed: 38942347
DOI: 10.1016/j.apmr.2024.06.005 -
Clinical Neurology and Neurosurgery Jun 2024
Letter to the editor. "Surgical evacuation of spontaneous cerebellar hemorrhage: Comparison of safety and efficacy of suboccipital craniotomy and robotic-assisted stereotactic hematoma drainage".
PubMed: 38941710
DOI: 10.1016/j.clineuro.2024.108384 -
Emergency Radiology Jun 2024Pleural effusion is a very common clinical finding. Quantifying pleural effusion volume and its response to treatment over time has become increasingly important for... (Review)
Review
Pleural effusion is a very common clinical finding. Quantifying pleural effusion volume and its response to treatment over time has become increasingly important for clinicians, which is currently performed via computed tomography (CT) or drainage. To determine and compare ultrasonography (US), CT, and drainage agreements in pleural effusion volumetry. Protocol pre-registration was performed a priori at ( https://osf.io/rnugd/ ). We searched PubMed, Web of Science, Embase, and Cochrane Library for studies up to January 7, 2024. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2), QUADAS-C, and Consensus-based Standards for the selection of health Measurement Instruments (COSMIN). Volumetric performances of CT, US, and drainage in assessment of pleural effusion volume were evaluated through both aggregated data (AD) and individual participant data (IPD) analyses. Certainty of evidence was evaluated using Grading of Recommendations, Assessment, Development, and Evaluations (GRADE). Six studies were included with 446 pleural effusion lesions. AD results showed a perfect level of agreement with pooled Pearson correlation and intraclass correlation coefficient (ICC) of 0.933 and 0.948 between US and CT. IPD results demonstrated a high level of agreement between US and CT, with Finn's coefficient, ICC, concordance correlation coefficient (CCC), and Pearson correlation coefficient values of 0.856, 0.855, 0.854, and 0.860, respectively. Also, both results showed an overall perfect level of agreement between US and drainage. As for comparing the three combinations, US vs. CT and US vs. drainage were both superior to CT vs. drainage, suggesting the US is a good option for pleural effusion volumetric assessment. Ultrasound provides a highly reliable, to-the-point, cost-effective, and noninvasive method for the assessment of pleural effusion volume and is a great alternative to CT or drainage.
PubMed: 38941026
DOI: 10.1007/s10140-024-02252-y -
The Cochrane Database of Systematic... Jun 2024Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems.
OBJECTIVES
To assess the effectiveness of PICC material and design in reducing catheter failure and complications.
SEARCH METHODS
The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) evaluating PICC design and materials.
DATA COLLECTION AND ANALYSIS
We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE.
MAIN RESULTS
We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence).
AUTHORS' CONCLUSIONS
There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.
Topics: Humans; Randomized Controlled Trials as Topic; Catheterization, Peripheral; Catheter-Related Infections; Equipment Failure; Equipment Design; Venous Thromboembolism; Catheter Obstruction; Central Venous Catheters; Cause of Death; Bias; Catheterization, Central Venous; Bacteremia
PubMed: 38940297
DOI: 10.1002/14651858.CD013366.pub2 -
The Annals of Applied Statistics Dec 2023Coronavirus case-count data has influenced government policies and drives most epidemiological forecasts. Limited testing is cited as the key driver behind minimal...
Coronavirus case-count data has influenced government policies and drives most epidemiological forecasts. Limited testing is cited as the key driver behind minimal information on the COVID-19 pandemic. While expanded testing is laudable, measurement error and selection bias are the two greatest problems limiting our understanding of the COVID-19 pandemic; neither can be fully addressed by increased testing capacity. In this paper, we demonstrate their impact on estimation of point prevalence and the effective reproduction number. We show that estimates based on the millions of molecular tests in the US has the same mean square error as a small simple random sample. To address this, a procedure is presented that combines case-count data and random samples over time to estimate selection propensities based on key covariate information. We then combine these selection propensities with epidemiological forecast models to construct a estimation method that accounts for both measurement-error and selection bias. This method is then applied to estimate Indiana's active infection prevalence using case-count, hospitalization, and death data with demographic information, a statewide random molecular sample collected from April 25-29th, and Delphi's COVID-19 Trends and Impact Survey. We end with a series of recommendations based on the proposed methodology.
PubMed: 38939875
DOI: 10.1214/23-aoas1744 -
Frontiers in Psychiatry 2024Individuals with anxiety disorders (ADs) often display hypervigilance to threat information, although this response may be less pronounced following psychotherapy. This...
BACKGROUND
Individuals with anxiety disorders (ADs) often display hypervigilance to threat information, although this response may be less pronounced following psychotherapy. This study aims to investigate the unconscious recognition performance of facial expressions in patients with panic disorder (PD) post-treatment, shedding light on alterations in their emotional processing biases.
METHODS
Patients with PD (n=34) after (exposure-based) cognitive behavior therapy and healthy controls (n=43) performed a subliminal affective recognition task. Emotional facial expressions (fearful, happy, or mirrored) were displayed for 33 ms and backwardly masked by a neutral face. Participants completed a forced choice task to discriminate the briefly presented facial stimulus and an uncovered condition where only the neutral mask was shown. We conducted a secondary analysis to compare groups based on their four possible response types under the four stimulus conditions and examined the correlation of the false alarm rate for fear responses to non-fearful (happy, mirrored, and uncovered) stimuli with clinical anxiety symptoms.
RESULTS
The patient group showed a unique selection pattern in response to happy expressions, with significantly more correct "happy" responses compared to controls. Additionally, lower severity of anxiety symptoms after psychotherapy was associated with a decreased false fear response rate with non-threat presentations.
CONCLUSION
These data suggest that patients with PD exhibited a "happy-face recognition advantage" after psychotherapy. Less symptoms after treatment were related to a reduced fear bias. Thus, a differential facial emotion detection task could be a suitable tool to monitor response patterns and biases in individuals with ADs in the context of psychotherapy.
PubMed: 38938460
DOI: 10.3389/fpsyt.2024.1375751 -
Psychiatric Services (Washington, D.C.) Jun 2024Algorithms for guiding health care decisions have come under increasing scrutiny for being unfair to certain racial and ethnic groups. The authors describe their...
Algorithms for guiding health care decisions have come under increasing scrutiny for being unfair to certain racial and ethnic groups. The authors describe their multistep process, using data from 3,465 individuals, to reduce racial and ethnic bias in an algorithm developed to identify state Medicaid beneficiaries experiencing homelessness and chronic health needs who were eligible for coordinated health care and housing supports. Through an iterative process of adjusting inputs, reviewing outputs with diverse stakeholders, and performing quality assurance, the authors developed an algorithm that achieved racial and ethnic parity in the selection of eligible Medicaid beneficiaries.
PubMed: 38938093
DOI: 10.1176/appi.ps.20230359