Journal of Orthopaedic Science :... Jun 2024The aim of this study was to compare outcomes and complications in patients with and without a history of prior rotator cuff surgery who underwent reverse total shoulder...
Does prior rotator cuff surgery influence the outcomes and complications after reverse total shoulder arthroplasty in patients with cuff tear arthropathy or massive rotator cuff tear? A propensity score-matched study.
BACKGROUND
The aim of this study was to compare outcomes and complications in patients with and without a history of prior rotator cuff surgery who underwent reverse total shoulder arthroplasty (RTSA).
METHODS
Two-hundred and nine consecutive patients who had undergone RTSA for rotator cuff insufficiency with a minimum 12-months follow-up period were reviewed. A total of 35 patients with a history of prior rotator cuff surgery were made the study group (PS group). Using propensity score matching for age and sex, these patients were matched 1:3 with a control group of 105 patients with no history of prior surgery (NPS group). The mean follow-up period was 41.4 months.
RESULTS
Both groups showed a significant improvement of clinical scores and range of motion after RTSA. The PS group showed a significantly higher final visual analog scale (VAS) pain score compared with the NPS group (P = 0.020). The PS group showed a significantly higher incidence of acromial stress fracture compared with the NPS group (17.1% vs 4.8%, P = 0.018), but no significant difference in the overall complication rate was observed (25.7% vs 13.3%, P > 0.05). The PS group showed a significantly higher reoperation rate compared with the NPS group (14.3% vs 1.9%, P = 0.004).
CONCLUSIONS
Our study demonstrated that a history of prior rotator cuff surgery was associated with a high incidence of acromial stress fracture and reoperation after RTSA as well as a high final VAS pain score, although satisfactory clinical outcomes after RTSA were achieved in both groups.
PubMed: 38942650
DOI: 10.1016/j.jos.2024.06.010 -
Journal of Shoulder and Elbow Surgery Jun 2024Coronal shear fractures of the capitellum are rare injuries which can be challenging to treat. The aim of this study was to compare the biomechanical properties of...
OBJECTIVE
Coronal shear fractures of the capitellum are rare injuries which can be challenging to treat. The aim of this study was to compare the biomechanical properties of different internal screw fixation techniques for Dubberley type IA fractures of the capitellum.
METHODS
In this biomechanical study, Dubberley type IA fractures of the capitellum were created in 30 human fresh-frozen humeri. The specimens were then divided into three groups: fixation was either performed with 3 x 3.0 mm headless cannulated compression screws (HCCSs) in anteroposterior (AP) orientation (AP group), 3 x 3.0 mm HCCSs in posteroanterior (PA) orientation (PA group) or with 2 x 3.0 mm HCCSs in PA orientation and 1 x 3.0 mm HCCS in lateral orientation (LAT group). Displacement under cyclic loading and ultimate load-to-failure were evaluated in all specimens.
RESULTS
There was no significant difference in fragment displacement after 2000 cycles between AP and PA groups (0.8 ± 0.5 mm vs. 0.8 ± 0.6 mm; p = 0.987) or PA and LAT groups (0.8 ± 0.6 mm vs. 0.8 ± 0.3 mm; p = 0.966). LAT group showed the highest load-to-failure (548 ± 250 N) without reaching statistically significant difference to AP group (388 ± 173 N; p = 0.101). There was also no significant difference between AP and PA groups (388 ± 173 N vs. 422 ± 114 N; p = 0.649).
CONCLUSIONS
Variations in screw placement had no statistically significant influence on cyclic displacement or load-to-failure in Dubberley Type IA fractures. However, fracture fixation in two planes - both the coronal and the sagittal plane - by adding a screw in a lateral to medial direction may be beneficial to increase primary stability.
PubMed: 38942223
DOI: 10.1016/j.jse.2024.05.007 -
The Journal of Hand Surgery Jun 2024Trapeziometacarpal (TMC) joint replacement has become a valid option in the therapeutic arsenal of TMC joint osteoarthritis in Europe. Good mid-term results of the MAÏA...
PURPOSE
Trapeziometacarpal (TMC) joint replacement has become a valid option in the therapeutic arsenal of TMC joint osteoarthritis in Europe. Good mid-term results of the MAÏA TMC joint prosthesis suggested that it is a reliable procedure. This study aimed to assess the long-term results of this modular uncemented ball-and-socket hydroxyapatite-coated implant.
METHODS
This single-center retrospective study evaluated 92 MAÏA TMC joint prostheses in 76 patients with a minimum of 10 years of follow-up. Indications for the procedure were painful TMC joint osteoarthritis both at rest and during activity, despite nonsurgical treatment for more than six months. Pre- and postoperative clinical and radiographic outcomes were compared.
RESULTS
Mean follow-up was 134 months (range: 120-158 months). Mean age at the time of surgery was 67 years (range: 53-84 years). The cohort comprised 86.8% of women (n = 66). The mean Quick Disabilities of the Arm, Shoulder, and Hand score improved from 61.3 ± 17.1 to 19.6 ± 16. Range of motion was restored, and postoperative mobility was comparable with that of the contralateral side. Final Kapandji opposition score was almost normal (9.2 ± 0.7). Final key pinch and grip strength improved by 26% and 39%, respectively. Eight implants were surgically revised, six for trapezium cup loosening and two for instability because of polyethylene wear. Three cases of traumatic fracture of the trapezium in older patients were successfully treated with a cast for eight weeks. Five of 26 (20.8%) cases of preoperative-reducible z-deformity were not totally corrected after surgery. The Kaplan-Meier survival over 10 years was 88% (95% confidence interval: 84-93) versus 93% (95% confidence interval: 87-98) over 5 years.
CONCLUSIONS
MAÏA TMC joint prosthesis is a reliable long-term surgical procedure for TMC joint osteoarthritis, improving overall function beyond 10 years.
TYPE OF STUDY/LEVEL OF EVIDENCE
Therapeutic IV.
PubMed: 38935000
DOI: 10.1016/j.jhsa.2024.03.019 -
Journal of Clinical Medicine Jun 2024: The aim of the study was to investigate the clinical, functional, and radiographic results of patients affected by three- or four-part proximal humeral fractures...
: The aim of the study was to investigate the clinical, functional, and radiographic results of patients affected by three- or four-part proximal humeral fractures treated with reverse total shoulder arthroplasty, to investigate whether a prosthetic stem nonspecifically designed for fractures (i.e., the Bigliani-Flatow stem) promotes tuberosities' healing, and to evaluate the impact of tuberosity fixation and healing on the outcomes. : Patients' data such as gender, age, side and dominancy, comorbidities, complications during or after surgery, and time lapse between trauma and surgery were prospectively collected. The type of fixation of the stem, the thickness and type of liner, and whether the tuberosities were fixed or not were also recorded. The Constant score weighted on the contralateral limb, QuickDASH, Oxford Shoulder Score, and Subjective Shoulder Value were collected. Tuberosities' healing was assessed with X-rays (anteroposterior, Grashey, and axillary views). : Overall, 34 patients were included, with an average follow-up of 42 months. Tuberosities were reinserted in 24 cases and their healing rate was 83%. The mean values were the following: a Constant score of 64, Oxford Shoulder Score of 39, Subjective Shoulder Value of 71, and QuickDASH score of 27. There were no significant differences in the scores or range of motion between patients with tuberosities healed, reabsorbed, or not reattached. There was a better external rotation in the group with healed tuberosities and a longer duration of surgery to reattach tuberosities. : The treatment of proximal humerus fractures with the Bigliani-Flatow stem is associated with good clinical and functional results. The healing rate of the tuberosities was high and comparable, if not even better, than the mean rates reported for the stems dedicated to fractures of the proximal humerus and was, therefore, also appropriate for this indication.
PubMed: 38929917
DOI: 10.3390/jcm13123388 -
Cureus May 2024Introduction Fixed prosthodontic treatment involves the replacement of missing tooth structures with a variety of materials. Several newer metal-free ceramics have been...
Introduction Fixed prosthodontic treatment involves the replacement of missing tooth structures with a variety of materials. Several newer metal-free ceramics have been developed in recent years to meet patients' aesthetic needs. The long-term performance of all ceramics, however, is unknown, necessitating a continuous evaluation of the materials' strength. Aim The aim of this study was to compare and evaluate the fracture resistance of IPS E max pressable crowns and graphene crowns, which are luted with Rely X U200 self-adhesive resin cement on the respective dies, as well as thermocycling of IPS E max pressable crowns and thermocycling of graphene crowns. The current review was conducted as an in vitro examination at the Division of Prosthodontics, GSL Dental School, Rajahmundry, Andhra Pradesh, India. Materials and methods On a typodont tooth, a shoulder finish line design was prepared and incisal reduction was performed. The tooth was scanned, designed, and milled to produce 18 metal dies made of cobalt-chrome alloy. These metal dies produced a total of (n=36) all-ceramic crowns, which were divided into two groups based on crown type: 18 IPS E max crowns and 18 graphene crowns. The participants were once again divided into two subgroups within each group, with the purpose of assessing fracture resistance. This evaluation was conducted using a universal testing machine both before and after subjecting the specimens to thermocycling. The obtained data were sent for statistical analysis. Results Fracture resistance values were reduced after thermocycling of both IPS E max and Graphene crowns. Without thermocycling, the fracture resistance values of IPS E max crowns were higher than those of graphene crowns. Conclusions The fracture resistance of IPS E max crowns exhibited a statistically significant increase when compared to graphene crowns. Additionally, it was shown that the fracture resistance of both materials was reduced upon exposure to thermocycling.
PubMed: 38919249
DOI: 10.7759/cureus.61097 -
Zhongguo Xiu Fu Chong Jian Wai Ke Za... Jun 2024To summarize the surgical accidents and postoperative complications of the treatment of recurrent shoulder dislocation by suture button fixation and bone occlusion, and...
OBJECTIVE
To summarize the surgical accidents and postoperative complications of the treatment of recurrent shoulder dislocation by suture button fixation and bone occlusion, and to provide clinical reference.
METHODS
The clinical data of 16 patients with recurrent shoulder dislocation treated with modified arthroscopic Latarjet suture button fixation and bone occlusion between July 2017 and April 2023 were retrospectively analyzed. Among them, 15 were male and 1 was female. The age ranged from 16 to 45 years, with an average of 26 years. Admission examination showed the range of motion of shoulder joint was normal; the shoulder joint fear test was positive; En-face CT scan measured 10%-20% of the glenoid defects, averaging 13.4%; and MRI examination revealed bone Bankart injury. The disease duration ranged from 2 to 20 years, with an average of 7.1 years. The shoulder joint was dislocated 8- 45 times, with an average of 17.4 times, and the shoulder joint was unstable. The occurrence of surgical accidents and postoperative complications as well as corresponding measures and outcomes were recorded.
RESULTS
All the incisions healed by first intention without any complications such as incision infection or vascular injury. All 16 cases were followed up for an average of 3.6 years (range, 1-7 years), and no shoulder redislocation occurred. Four types of intraoperative surgical accidents and two types of postoperative complications occurred in the early stage of implementation of the technique. Intraoperative surgical accidents included 1 case of difficulty in passing subscapular muscle through coracotomy with large size, which was treated with exchange rod or finger through subscapular muscle split; 2 cases of coracoidal process fracture, of which 1 case was treated conservatively, and the other case was sutured to the base of tendon and fixed through tunnel; 1 case of glenoid fracture occurred in the glenoid tunnel, which was fixed with knot-free anchors; the posterior loop plate fixation was abnormal in 2 cases, of which 1 case was re-fixed and the other case was renovated. Postoperative complications included coracoid bone mass displacement in 1 case, conservative biceps rehabilitation was given to avoid premature external rotation; 1 case of radial nerve injury of healthy upper limb and musculocutaneous nerve injury of affected side was given oral medication and physiotherapy. The above conditions recovered well after corresponding treatment.
CONCLUSION
Suture button fixation with bone occlusion is a safe method for the treatment of recurrent shoulder dislocation. Careful operation should be performed during coracoid interception and glenoid tunnel drilling, especially in the fixation process.
Topics: Humans; Male; Shoulder Dislocation; Female; Adult; Adolescent; Postoperative Complications; Young Adult; Arthroscopy; Middle Aged; Range of Motion, Articular; Shoulder Joint; Recurrence; Treatment Outcome; Suture Techniques
PubMed: 38918188
DOI: 10.7507/1002-1892.202404050 -
Zhongguo Xiu Fu Chong Jian Wai Ke Za... Jun 2024To assess the effectiveness of suture button fixation Latarjet procedure under total arthroscopy for anterior shoulder instability with severe bone defects.
OBJECTIVE
To assess the effectiveness of suture button fixation Latarjet procedure under total arthroscopy for anterior shoulder instability with severe bone defects.
METHODS
The clinical data of 15 patients with severe bone defects and anterior shoulder instability treated with suture button fixation Latarjet procedure under total arthroscopy between June 2020 and February 2023 was retrospectively analyzed, including 11 males and 4 females, with an average age of 31.1 years (range, 20-54 years). Three-dimensional CT showed that the average glenoid bone defect was 24.4% (range, 16.3%-35.2%). The average number of shoulder dislocation was 4.2 times (range, 3-8 times). The disease duration ranged from 6 to 21 months with an average of 10.6 months. The operation time and intraoperative blood loss were recorded. The pain relief was evaluated by visual analogue scale (VAS) score, and the functional recovery of shoulder joint was evaluated by Rowe score, Walch-Duplay score, and American Association for Shoulder and Elbow Surgery (ASES) score before and after operation. The range of motion (ROM) of the shoulder joint was assessed, including active flexion, lateral external rotation, abduction 90° external rotation, and internal rotation. Three-dimensional CT was performed at 6 months after operation and at last follow-up to observe the absorption of bone graft, the position of bone graft and glenoid, and the healing of bone graft.
RESULTS
The operation was successfully completed in all patients. The operation time was 85-195 minutes, with an average of 123.0 minutes. The intraoperative blood loss was 20-75 mL, with an average of 26.5 mL. All patients were followed up 13-32 months, with an average of 18.7 months. During the follow-up, there was no serious complication such as shoulder joint infection, joint stiffness, or vascular and nerve injury. One patient had partial absorption of the transplanted bone and bone nonunion at 3 months after operation, but the pain of the shoulder joint relieved at last follow-up, and no redislocation of the shoulder joint occurred; no obvious bone fracture or dislocation of the shoulder joint was found in the other patients. Bone union was achieved at 6 months during follow-up. At last follow-up, the VAS score, Rowe score, Walch-Duplay score, and ASES score significantly improved when compared with those before operation ( <0.05), while the ROM of active flexion, lateral external rotation, abduction 90° external rotation, and internal rotation of the shoulder joint was not significantly different from those before operation ( >0.05).
CONCLUSION
Suture button fixation Latarjet procedure under total arthroscopy can improve shoulder joint function in patients with severe anterior shoulder instability caused by bone defects, and imaging also indicates satisfactory placement of transplanted bone blocks.
Topics: Humans; Male; Female; Arthroscopy; Adult; Joint Instability; Shoulder Joint; Young Adult; Middle Aged; Range of Motion, Articular; Shoulder Dislocation; Treatment Outcome; Tomography, X-Ray Computed
PubMed: 38918185
DOI: 10.7507/1002-1892.202403121 -
BMC Musculoskeletal Disorders Jun 2024Most studies infer increasing incidence of proximal humeral fractures (PHF) from the 1950´s until the 1990´s. Recent time trends are less clear.
BACKGROUND
Most studies infer increasing incidence of proximal humeral fractures (PHF) from the 1950´s until the 1990´s. Recent time trends are less clear.
OBJECTIVES
Our primary objective was to identify time trends in the age- and sex-adjusted adult incidence of PHF in Malmö, Sweden, from year 1944 until 2020. Our secondary objectives were to describe the variation in incidence according to age, the monthly distribution, and to compare data from the two most recent decades with earlier.
STUDY DESIGN AND METHODS
Malmö has one emergency hospital where acute fractures are treated. We identified PHF in adult patients (≥ 18 years) by reviewing relevant radiology examinations during 17 sample years from year 1944 to 2020. We used jointpoint analyses to estimate time trends.
RESULTS
We identified 3 031 PHF during the study period (3 231 161 person years), 73% were sustained by women with mean age of 69 years (mean age in men 59). Joinpoint analyses indicated an increase in the age- and sex-adjusted incidence of PHF from year 1944 (52 per 100 000 person years) until 1977 (120 per 100 000) and thereafter a decrease until 2020 (85 per 100 000). A seasonal variation with more fractures during winter months, was apparent in earlier but not recent decades.
CONCLUSIONS
The age- and sex-adjusted incidence of PHF increased in Malmö, Sweden, from the 1940´s until year 1977 and thereafter decreased until 2020. More fractures were seen during winter months in earlier but not recent decades.
Topics: Humans; Sweden; Female; Male; Aged; Middle Aged; Shoulder Fractures; Incidence; Adult; Aged, 80 and over; Time Factors; Young Adult; Cohort Studies; Seasons; Adolescent
PubMed: 38914972
DOI: 10.1186/s12891-024-07602-y -
Journal of Pediatric Orthopedics Jun 2024Proximal humerus fractures (PHFx) constitute around 2% of all pediatric fractures. Although younger children with displaced fractures often undergo nonoperative...
BACKGROUND
Proximal humerus fractures (PHFx) constitute around 2% of all pediatric fractures. Although younger children with displaced fractures often undergo nonoperative treatments, optimal treatment for adolescents is not well defined. The study aimed to assess the outcomes of operative versus nonoperative treatment of displaced proximal humerus fractures in adolescents via a prospective multicenter study.
METHODS
This prospective study assessed adolescents aged 10 to 16 years with displaced PHFx from 2018 to 2022 at 6 level 1 trauma centers. Displacement criteria for inclusion were >50% shaft diameter or angulation >30 degrees on AP/lateral shoulder X-rays. Operative versus nonoperative treatment was decided by the treating physician. Radiographic and clinical data were collected at 6 weeks, 3, and 6 months. Patient-reported outcomes (PROs) included: Patient Reported Outcome Measures (PROMIS), Shoulder Pain and Disability Index (SPADI), and QuickDASH questionnaires. Patients were further grouped into a severe displacement cohort, defined as angulation >40° or displacement >75%. Clinical and radiographic data were compared between the 2 treatment cohorts.
RESULTS
Out of 78 enrolled patients, 36 (46%) underwent operative treatment. Patients treated operatively were significantly older (13.5 vs. 12.2 y, P<0.001) and exhibited greater mean angulation on AP shoulder view at presentation (31.1° vs. 23.5°, P<0.05). All PROs improved over time. At 6 weeks, operative patients demonstrated superior PROMIS upper extremity scores based on the minimally clinically important difference (MCID) (46.4 vs. 34.3, P=0.027); however, this distinction disappeared by 3 months. In a subanalysis of 35 patients with severe displacement, 21 (60.1%) underwent surgical intervention. No metrics showed significant differences between treatment modalities, with all PROs achieving population norm values by 3 months. Range of motion showed no difference between operative and nonoperative treatments, irrespective of fracture displacement.
CONCLUSION
We found no differences in PROs and ROM between operative and nonoperative treatments of PHFx. If not contraindicated, nonoperative treatment may reduce healthcare costs and risks associated with surgery and should be considered for displaced adolescent proximal humerus fractures, irrespective of fracture displacement.
LEVEL OF EVIDENCE
II.
PubMed: 38912592
DOI: 10.1097/BPO.0000000000002755 -
Orthopaedic Journal of Sports Medicine Jun 2024While prevention protocols have been implemented, skiing-related musculoskeletal injuries and concussions continue to present to emergency departments in the United...
BACKGROUND
While prevention protocols have been implemented, skiing-related musculoskeletal injuries and concussions continue to present to emergency departments in the United States. Previous literature has suggested the pediatric population may constitute up to 40% of skiing-related injuries.
PURPOSE
To assess injury trends and the underlying mechanisms of skiing injuries in pediatric patients seen at emergency departments in the United States.
STUDY DESIGN
Descriptive epidemiology study.
METHODS
The National Electronic Injury Surveillance System (NEISS) was queried for pediatric (age ≤18 years) skiing injuries between January 1, 2012, and December 31, 2022. Injury mechanism, location, disposition, and diagnosis were recorded, and the statistical sample weight assigned by NEISS by hospital was used to calculate national estimates (NEs). Injury trends were evaluated with linear regression analysis.
RESULTS
Overall, 2951 pediatric skiing injuries were included (NE = 123,386). The mean age of the patients was 12.4 ± 3.5 years, with 61.3% of the injuries occurring in male patients. Impact with the ground was the most common injury mechanism (NE = 87,407; 70.8%). Fractures were the most common diagnosis (NE = 38,527, 31.2%), followed by strains/sprains (NE = 22,562, 18.3%), contusions/abrasions (NE = 16,257, 13.2%), and concussions (NE = 12,449, 10.1%). The lower leg was the most common fracture site (NE = 9509, 24.7%), followed by the shoulder (NE = 7131, 18.5%) and lower arm (NE = 5876, 15.3%). Analysis of annual injuries revealed no significant trend between 2012 and 2022 ( = .17), with fluctuations apparent throughout the study period. Significant decreases were seen in strains/sprains ( < .01) and contusions/abrasions ( < .01), but not in concussions ( = .57) or fractures ( = .70).
CONCLUSION
Impacts with the snow/ground made up 70.8% of all injuries. Fractures were the most common injury diagnosis, followed by strains/sprains, with the lower leg being most frequently fractured. While strains/sprains and contusions/abrasions showed a significant decline, there were no significant trends in fractures and concussions between 2012 and 2022.
PubMed: 38911123
DOI: 10.1177/23259671241255704