-
Genes Jun 2024The ring finger protein 213 gene (RNF213) is involved in several vascular diseases, both intracranial and systemic ones. Some variants are common in the Asian population...
The ring finger protein 213 gene (RNF213) is involved in several vascular diseases, both intracranial and systemic ones. Some variants are common in the Asian population and are reported as a risk factor for moyamoya disease, intracranial stenosis and intracranial aneurysms. Among intracranial vascular diseases, both moyamoya disease and intracranial artery dissection are more prevalent in the Asian population. We performed a systematic review of the literature, aiming to assess the rate of RNF213 variants in patients with spontaneous intracranial dissections. Four papers were identified, providing data on 53 patients with intracranial artery dissection. The rate of RNF213 variants is 10/53 (18.9%) and it increases to 10/29 (34.5%), excluding patients with vertebral artery dissection. All patients had the RNF213 p.Arg4810Lys variant. RNF213 variants seems to be involved in intracranial dissections in Asian cohorts. The small number of patients, the inclusion of only patients of Asian descent and the small but non-negligible coexistence with moyamoya disease familiarity might be limiting factors, requiring further studies to confirm these preliminary findings and the embryological interpretation.
Topics: Humans; Adenosine Triphosphatases; Aortic Dissection; Asian People; Genetic Predisposition to Disease; Intracranial Aneurysm; Moyamoya Disease; Polymorphism, Single Nucleotide; Ubiquitin-Protein Ligases
PubMed: 38927660
DOI: 10.3390/genes15060725 -
PloS One 2024To evaluate the diagnostic accuracy of the aortic dissection detection risk score (ADD-RS) used alone or in combination with D-dimer for detecting acute aortic syndrome... (Meta-Analysis)
Meta-Analysis
OBJECTIVES
To evaluate the diagnostic accuracy of the aortic dissection detection risk score (ADD-RS) used alone or in combination with D-dimer for detecting acute aortic syndrome (AAS) in patients presenting with symptoms suggestive of AAS.
METHODS
We searched MEDLINE, EMBASE, and the Cochrane Library from inception to February 2024. Additionally, the reference lists of included studies and other systematic reviews were thoroughly searched. All diagnostic accuracy studies that assessed the use of ADD-RS alone or with D-Dimer for diagnosing AAS compared with a reference standard test (e.g. computer tomographic angiography (CTA), ECG-gated CTA, echocardiography, magnetic resonance angiography, operation, or autopsy) were included. Two reviewers independently selected and extracted data. Risk of bias was appraised using QUADAS-2 tool. Data were synthesised using hierarchical meta-analysis models.
RESULTS
We selected 13 studies from the 2017 citations identified, including six studies evaluating combinations of ADD-RS alongside D-dimer>500ng/L. Summary sensitivities and specificities (95% credible interval) were: ADD-RS>0 94.6% (90%, 97.5%) and 34.7% (20.7%, 51.2%), ADD-RS>1 43.4% (31.2%, 57.1%) and 89.3% (80.4%, 94.8%); ADD RS>0 or D-Dimer>500ng/L 99.8% (98.7%, 100%) and 21.8% (12.1%, 32.6%); ADD RS>1 or D-Dimer>500ng/L 98.3% (94.9%, 99.5%) and 51.4% (38.7%, 64.1%); ADD RS>1 or ADD RS = 1 with D-dimer>500ng/L 93.1% (87.1%, 96.3%) and 67.1% (54.4%, 77.7%).
CONCLUSIONS
Combinations of ADD-RS and D-dimer can be used to select patients with suspected AAS for imaging with a range of trade-offs between sensitivity (93.1% to 99.8%) and specificity (21.8% to 67.1%).
Topics: Humans; Fibrin Fibrinogen Degradation Products; Aortic Dissection; Syndrome; Sensitivity and Specificity; Acute Disease; Computed Tomography Angiography; Acute Aortic Syndrome
PubMed: 38905181
DOI: 10.1371/journal.pone.0304401 -
Journal of Clinical Medicine May 2024: The right-sided aortic arch (RAA) is an uncommon variation of the aortic arch (AA), characterized by the aorta crossing over the right main bronchus. In the RAA, the... (Review)
Review
: The right-sided aortic arch (RAA) is an uncommon variation of the aortic arch (AA), characterized by the aorta crossing over the right main bronchus. In the RAA, the descending aorta can be found on either the right or left side of the spine. The current study comprises a comprehensive retrospective computed tomography angiography (CTA) investigation into the prevalence of the RAA within the Greek population. Additionally, we will conduct a systematic review and meta-analysis to elucidate both common and rare morphological variants of the RAA. This research is significant as it sheds light on the prevalence and characteristics of the RAA in a specific population, providing valuable insights for clinical practice. : Two hundred CTAs were meticulously investigated for the presence of a RAA. In addition, the PubMed, Google Scholar, and Scopus online databases were thoroughly searched for studies referring to the AA morphology. The R programming language and RStudio were used for the pooled prevalence meta-analysis, while several subgroup analyses were conducted. : A unique case of 200 CTAs (0.5%) was identified with an uncommon morphology. The following branches emanated from the RAA under the sequence: the right subclavian artery (RSA), the right common carotid artery (RCCA), the left common carotid artery (LCCA), and the left vertebral artery (LVA) in common origin with the aberrant left subclavian artery (ALSA). The ALSA originated from a diverticulum (of Kommerell) and followed a retroesophageal course. : Sixty-two studies (72,187 total cases) met the inclusion criteria. The pooled prevalence of the RAA with a mirror-image morphology was estimated at 0.07%, and the RAA with an ALSA was estimated at <0.01%. AA anomalies, specifically the RAA, raise clinical interest due to their coexistence with developmental heart anomalies and possible interventional complications. Congenital heart anomalies, such as the Tetralogy of Fallot and patent foramen ovale, coexisted with RAA mirror-image morphology.
PubMed: 38892815
DOI: 10.3390/jcm13113105 -
Annals of Emergency Medicine Jun 2024Acute aortic syndrome is a life-threatening emergency condition. Previous systematic reviews of D-dimer diagnostic accuracy for acute aortic syndrome have been...
STUDY OBJECTIVE
Acute aortic syndrome is a life-threatening emergency condition. Previous systematic reviews of D-dimer diagnostic accuracy for acute aortic syndrome have been contradictory and based on limited data, but recently published studies offer potential for a more definitive overview. We aimed to perform a systematic review and meta-analysis to determine the diagnostic accuracy of D-dimer for diagnosing acute aortic syndrome.
METHODS
We searched MEDLINE, EMBASE, and the Cochrane Library from inception to February 2024. Additionally, the reference lists of included studies and other systematic reviews were thoroughly searched. All diagnostic cohort studies (prospective or retrospective) that assessed the use of D-dimer for diagnosing acute aortic syndrome compared with a reference standard test (eg, computed tomographic angiography (CTA), ECG-gated CTA, echocardiography, magnetic resonance angiography, operation, or autopsy) were included. Two independent reviewers completed study selection, data extractions and quality assessment using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Data were synthesized using a bivariate meta-analysis model.
RESULTS
Of 2017 potentially relevant citations, 25 cohort studies met the inclusion criteria, and 18 reporting the 500 ng/mL threshold were included in the primary meta-analysis. Risk of bias domains were mostly unclear due to limited study reporting. The summary sensitivity was 96.5% (95% credible interval [CrI] 94.8% to 98%) and summary specificity was 56.2% (95% CrI, 48.3% to 63.9%). Study specificity varied markedly from 33% to 86%, indicating substantial heterogeneity. Sensitivity analysis including the 7 studies reporting other thresholds showed summary sensitivity of 95.7% (95% CrI, 93.2% to 97.5%) and summary specificity of 57.5% (95% CrI, 50.1% to 64.6%).
CONCLUSION
D-dimer concentration has high sensitivity (96.5%) and moderate specificity (56.2%) for acute aortic syndrome, with some uncertainty around estimates due to risk of bias and heterogeneity. Previous meta-analysis reporting higher specificity may be explained by inclusion of case-control studies that may overestimate accuracy.
PubMed: 38888529
DOI: 10.1016/j.annemergmed.2024.05.001 -
Frontiers in Cardiovascular Medicine 2024Optical coherence tomography (OCT) and intravascular ultrasound (IVUS) are superior to coronary angiography for guiding percutaneous coronary intervention (PCI)....
Optical coherence tomography-guided vs. intravascular ultrasound-guided percutaneous coronary intervention: a systematic review and meta-analysis of randomized controlled trials.
BACKGROUND
Optical coherence tomography (OCT) and intravascular ultrasound (IVUS) are superior to coronary angiography for guiding percutaneous coronary intervention (PCI). However, whether one technique is superior to the other is inconclusive.
METHODS
We searched PubMed, Embase, the Cochrane Library, and ClinicalTrials.gov from inception to November 2023 for randomized controlled trials (RCTs) comparing OCT and IVUS in patients undergoing PCI. RevMan 5.4 was used to pool outcomes with risk ratio (RR) as the effect measure.
RESULTS
Six RCTs (4,402 patients) were included in this meta-analysis. There was no significant difference between the OCT- and IVUS-guided PCI groups in the risk of major adverse cardiovascular events (RR 0.87, 95% CI: 0.65, 1.16; I= 0%) and cardiac mortality (RR 0.73, 95% CI: 0.24, 2.21; I= 0%). The results were consistent across the subgroups of the presence or absence of left main disease (P >0.1). There were no significant differences between OCT and IVUS in the risk of target lesion revascularization (RR 0.78, 95% CI: 0.47, 1.30; I= 0%), target vessel revascularization (RR 1.06, 95% CI: 0.69, 1.62; I= 0%), target-vessel myocardial infarction (RR 0.79, 95% CI: 0.40, 1.53; I= 0%), stent thrombosis (RR 0.59, 95% CI: 0.12, 2.97; I= 0%), and all-cause mortality (RR 1.01, 95% CI: 0.53, 1.90; I= 0%).
CONCLUSIONS
Our meta-analysis demonstrated similar clinical outcomes in OCT- and IVUS-guided PCI. New large-scale multicenter RCTs with long-term follow-up are required to confirm or refute our findings and provide more reliable results.
SYSTEMATIC REVIEW REGISTRATION
PROSPERO, identifier, CRD42023486933.
PubMed: 38883988
DOI: 10.3389/fcvm.2024.1395606 -
Journal of Pharmacy & Bioallied Sciences Apr 2024May-Thurner syndrome (MTS) is an anatomical condition of external luminal compression of common iliac vein due to a partial obstruction of the common iliac vein between... (Review)
Review
May-Thurner syndrome (MTS) is an anatomical condition of external luminal compression of common iliac vein due to a partial obstruction of the common iliac vein between common iliac artery and lumbar vertebra causes deep-vein thrombosis, venous hypertension, and chronic venous insufficiencies. In this article, we review present evidence of the clinical diagnosis and management of MTS. Here, we conducted a literature review of studies on MTS. We also reviewed different clinical features, presentation, diagnostic methods, and therapeutic procedure for this condition. Most studies mentioned the diagnosis of this condition is performed by color Doppler, computed tomographic angiography, venography, and problem-solving cases by intravascular ultrasound technique. Nonsurgical methods of management are first line, and vascular surgery is reserved for refractory cases. Multiple modalities are required to reach the diagnosis of MTS, and noninvasive intervention radiology methods are the first line of management. This review highlights the presentations of MTS and outlines diagnostic procedure and management.
PubMed: 38882842
DOI: 10.4103/jpbs.jpbs_1135_23 -
Archives of Medical Sciences.... 2024
Intravascular ultrasound-guided versus angiography-guided percutaneous coronary intervention in patients with unprotected left main coronary artery disease: a systematic review and meta-analysis of randomized controlled trials and propensity score-matched studies.
PubMed: 38846052
DOI: 10.5114/amsad/188269 -
Stroke and Vascular Neurology May 2024Recently, computational fluid dynamics (CFD) has been used to simulate blood flow of symptomatic intracranial atherosclerotic stenosis (sICAS) and investigate the...
BACKGROUND
Recently, computational fluid dynamics (CFD) has been used to simulate blood flow of symptomatic intracranial atherosclerotic stenosis (sICAS) and investigate the clinical implications of its haemodynamic features, which were systematically reviewed in this study.
METHODS
Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses and Meta-analysis of Observational Studies in Epidemiology statements, we searched PubMed and Embase up to March 2024 and screened for articles reporting clinical implications of haemodynamic parameters in sICAS derived from CFD models.
RESULTS
19 articles met the inclusion criteria, all studies recruiting patients from China. Most studies used CT angiography (CTA) as the source image for vessel segmentation, and generic boundary conditions, rigid vessel wall and Newtonian fluid assumptions for CFD modelling, in patients with 50%-99% sICAS. Pressure and wall shear stress (WSS) were quantified in almost all studies, and the translesional changes in pressure and WSS were usually quantified with a poststenotic to prestenotic pressure ratio (PR) and stenotic-throat to prestenotic WSS ratio (WSSR). Lower PR was associated with more severe stenosis, better leptomeningeal collaterals, prolonged perfusion time and internal borderzone infarcts. Higher WSSR and other WSS measures were associated with positive vessel wall remodelling, regression of luminal stenosis and artery-to-artery embolism. Lower PR and higher WSSR were both associated with the presence and severity of cerebral small vessel disease. Moreover, translesional PR and WSSR were promising predictors for stroke recurrence in medically treated patients with sICAS and outcomes after acute reperfusion therapy, which also provided indicators to assess the effects of stenting treatment on focal haemodynamics.
CONCLUSIONS
CFD is a promising tool in investigating the pathophysiology of ICAS and in risk stratification of patients with sICAS. Future studies are warranted for standardisation of the modelling methods and validation of the simulation results in sICAS, for its wider applications in clinical research and practice.
PubMed: 38806205
DOI: 10.1136/svn-2024-003202 -
CVIR Endovascular May 2024The purpose of this systematic review and meta-analysis was to evaluate the safety, technical, and clinical effectiveness of percutaneous Transarterial Embolization... (Review)
Review
PURPOSE
The purpose of this systematic review and meta-analysis was to evaluate the safety, technical, and clinical effectiveness of percutaneous Transarterial Embolization (TAE) in treating spontaneous retroperitoneal hematomas as well as assess treatment outcomes in patients who underwent target or empirical embolization.
MATERIALS AND METHODS
Through the PubMed, Embase, and Google Scholar databases, an extensive search was performed in the fields of spontaneous retroperitoneal hematomas treated with transcatheter arterial embolization. We collected pooled data on 141 patients from 6 separate articles selected according to the inclusion and exclusion criteria.
RESULTS
Technical success rate was 100% in all six studies, for both targeted and empirical embolization. The clinical success rate varied from 56.3 to 89.5%. The total number of complications related to the embolization procedure was 10 events out of 116 procedures analyzed. Empirical or empirical embolization was performed in three studies, where the source of active bleeding was not evident during DSA. A meta-analysis compared the rebleeding rates between targeted and empirical embolization groups. The odds ratio from pooled data from the three assessed studies (72 patients) showed no significant difference in rebleeding rates after empirical TAE compared with targeted TAE.
CONCLUSIONS
TAE is a safe, effective, and potentially life-saving procedure for the treatment of life-threatening spontaneous retroperitoneal hematomas. Empirical and targeted TAE procedures demonstrate a relatively low risk of complications, compared to the high technical and relatively high clinical success rates.
PubMed: 38789727
DOI: 10.1186/s42155-024-00462-6 -
BMC Cardiovascular Disorders May 2024Optical coherence tomography (OCT) guidance in percutaneous coronary intervention (PCI) has been shown to improve procedural outcomes. However, evidence supporting its... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Optical coherence tomography (OCT) guidance in percutaneous coronary intervention (PCI) has been shown to improve procedural outcomes. However, evidence supporting its superiority over angiography-guided PCI in terms of clinical outcomes is still emerging and limited. This study aimed to compare the efficacy and safety of OCT-guided PCI versus angiography-guided PCI in patients with coronary artery disease (CAD).
METHODS
A systematic search of electronic databases was conducted to identify randomized control trials (RCTs) comparing the clinical outcomes of OCT-guided and angiography-guided PCI in patients with CAD. Clinical endpoints including all-cause mortality, myocardial infarction (MI), target lesion revascularization (TLR), stent thrombosis and major adverse cardiac events (MACE) were assessed.
RESULTS
Eleven RCTs, comprising 2,699 patients in the OCT-guided group and 2,968 patients in the angiography-guided group met inclusion criteria. OCT-guided PCI was associated with significantly lower rates of cardiovascular death(RR 0.56; 95%CI: 0.32-0.98; p = 0.04; I = 0%), stent thrombosis(RR 0.56; 95%CI: 0.33-0.95; p = 0.03; I = 0%), and MACE (RR 0.79; 95%CI: 0.66-0.95; p = 0.01; I = 5%). The incidence of all-cause death (RR 0.71; 95%CI: 0.49-1.02; p = 0.06; I = 0%), myocardial infarction (RR 0.86; 95%CI: 0.67-1.10; p = 0.22; I = 0%) and TLR (RR 0.98; 95%CI: 0.73-1.33; p = 0.91; I = 0%) was non-significantly lower in the OCT-guided group.
CONCLUSIONS
Among patients undergoing PCI, OCT-guided PCI was associated with lower incidences of cardiovascular death, stent thrombosis and MACE compared to angiography-guided PCI.
TRIAL REGISTRATION
PROSPERO registration number: CRD42023484342.
Topics: Humans; Tomography, Optical Coherence; Percutaneous Coronary Intervention; Randomized Controlled Trials as Topic; Coronary Angiography; Coronary Artery Disease; Treatment Outcome; Risk Factors; Predictive Value of Tests; Male; Female; Middle Aged; Aged; Coronary Vessels; Coronary Thrombosis
PubMed: 38769510
DOI: 10.1186/s12872-024-03930-y