-
Molecular Psychiatry Feb 2024Abnormal findings on optical coherence tomography (OCT) and electroretinography (ERG) have been reported in participants with schizophrenia spectrum disorders (SSDs).... (Meta-Analysis)
Meta-Analysis
INTRODUCTION
Abnormal findings on optical coherence tomography (OCT) and electroretinography (ERG) have been reported in participants with schizophrenia spectrum disorders (SSDs). This study aims to reveal the pooled standard mean difference (SMD) in retinal parameters on OCT and ERG among participants with SSDs and healthy controls and their association with demographic characteristics, clinical symptoms, smoking, diabetes mellitus, and hypertension.
METHODS
Using PubMed, Scopus, Web of Science, and PSYNDEX, we searched the literature from inception to March 31, 2023, using specific search terms. This study was registered with PROSPERO (CRD4202235795) and conducted according to PRISMA 2020.
RESULTS
We included 65 studies in the systematic review and 44 in the meta-analysis. Participants with SSDs showed thinning of the peripapillary retinal nerve fiber layer (pRNFL), macular ganglion cell layer- inner plexiform cell layer, and retinal thickness in all other segments of the macula. A meta-analysis of studies that excluded SSD participants with diabetes and hypertension showed no change in results, except for pRNFL inferior and nasal thickness. Furthermore, a significant difference was found in the pooled SMD of pRNFL temporal thickness between the left and right eyes. Meta-regression analysis revealed an association between retinal thinning and duration of illness, positive and negative symptoms. In OCT angiography, no differences were found in the foveal avascular zone and superficial layer foveal vessel density between SSD participants and controls. In flash ERG, the meta-analysis showed reduced amplitude of both a- and b-waves under photopic and scotopic conditions in SSD participants. Furthermore, the latency of photopic a-wave was significantly shorter in SSD participants in comparison with HCs.
DISCUSSION
Considering the prior report of retinal thinning in unaffected first-degree relatives and the results of the meta-analysis, the findings suggest that retinal changes in SSDs have both trait and state aspects. Future longitudinal multimodal retinal imaging studies are needed to clarify the pathophysiological mechanisms of these changes and to clarify their utility in individual patient monitoring efforts.
Topics: Humans; Tomography, Optical Coherence; Electroretinography; Schizophrenia; Retina; Biomarkers; Male; Adult; Female; Nerve Fibers
PubMed: 38081943
DOI: 10.1038/s41380-023-02340-4 -
Neurosurgical Review Dec 2023Spinal dural arteriovenous fistulas (SDAVFs) constitute the most common type of spinal vascular malformations. Their diagnosis requires spinal digital subtraction... (Meta-Analysis)
Meta-Analysis Review
Spinal dural arteriovenous fistulas (SDAVFs) constitute the most common type of spinal vascular malformations. Their diagnosis requires spinal digital subtraction angiography (DSA), which is time-consuming, requires catheterizing many vessels, and exposes patient to a high radiation and contrast doses. This study aims to evaluate the usefulness of time-resolved MR angiography (TR-MRA) in SDAVF diagnosis. We performed a systematic review of the PubMed and EMBASE databases followed by a meta-analysis. TR-MRA was an index test, and spinal DSA was a reference. Of the initial 324 records, we included 4 studies describing 71 patients with SDAVFs. In 42 cases, TR-MRA was true positive, and in 21 cases, it was true negative. We found 7 false-positive cases and 1 false negative. TR-MRA allowed for shunt level identification in 39 cases. Of these, the predicted level was correct in 23 cases (59%), to within 1 level in 38 cases (97.4%) and to within 2 levels in 39 cases (100%). The diagnostic odds ratio was 72.73 (95% CI [10.30; 513.35]), z = 4.30, p value < 0.0001. The pooled sensitivity was 0.98 (95% CI [0.64; 1.00]), and the pooled specificity was 0.79 (95% CI [0.10; 0.99]). The AUC of the SROC curve was 0.9. TR-MRA may serve as a preliminary study to detect SDAVFs and localize the shunt level with sensitivity and specificity as high as 98% and 79%, respectively. Unless the TR-MRA result is unequivocal, it should be followed by a limited spinal DSA.
Topics: Humans; Contrast Media; Magnetic Resonance Angiography; Spine; Angiography, Digital Subtraction; Central Nervous System Vascular Malformations
PubMed: 38072856
DOI: 10.1007/s10143-023-02242-7 -
Vascular Medicine (London, England) Apr 2024This study aimed to review the current literature exploring the utility of noninvasive ocular imaging for the diagnosis of peripheral artery disease (PAD). Our search... (Review)
Review
This study aimed to review the current literature exploring the utility of noninvasive ocular imaging for the diagnosis of peripheral artery disease (PAD). Our search was conducted in early April 2022 and included the databases Medline, Scopus, Embase, Cochrane, and others. Five articles were included in the final review. Of the five studies that used ocular imaging in PAD, two studies used retinal color fundus photography, one used optical coherence tomography (OCT), and two used optical coherence tomography angiography (OCTA) to assess the ocular changes in PAD. PAD was associated with both structural and functional changes in the retina. Structural alterations around the optic disc and temporal retinal vascular arcades were seen in color fundus photography of patients with PAD compared to healthy individuals. The presence of retinal hemorrhages, exudates, and microaneurysms in color fundus photography was associated with an increased future risk of PAD, especially the severe form of the disease. The retinal nerve fiber layer (RNFL) was significantly thinner in the nasal quadrant in patients with PAD compared to age-matched healthy individuals in OCT. Similarly, the choroidal thickness in the subfoveal region was significantly thinner in patients with PAD compared to controls. Patients with PAD also had a significant reduction in the retinal and choroidal circulation in OCTA compared to healthy controls. As PAD causes thinning and ischemic changes in retinal vessels, examination of the retinal vessels using retinal imaging techniques can provide useful information about early microvascular damage in PAD. Ocular imaging could potentially serve as a biomarker for PAD. .
Topics: Humans; Optic Disk; Tomography, Optical Coherence; Photography; Peripheral Arterial Disease; Biomarkers; Retinal Vessels
PubMed: 38054219
DOI: 10.1177/1358863X231210866 -
Acta Ortopedica Mexicana 2023aneurysms are focal and permanent dilations of an artery; in pseudoaneurysms, the normal layers of the blood vessel are replaced by fibrous tissue. Due to their low...
INTRODUCTION
aneurysms are focal and permanent dilations of an artery; in pseudoaneurysms, the normal layers of the blood vessel are replaced by fibrous tissue. Due to their low incidence, as well as the diagnostic and therapeutic challenge they represent; our objective is to present the clinical case of a pseudoaneurysm of a digital artery of the hand and to carry out a systematic review of this pathology.
MATERIAL AND METHODS
literature search in Medline, using the terms "digital artery" and "aneurysm." Studies of vascular dilation pathology affecting the hand and fingers were incorporated. Studies with pathology of proximal involvement of the hand were excluded.
CASE PRESENTATION
a 79-year-old female patient who, after a sharp force trauma to the fifth finger of the left hand, develops a rapidly growing necrotic tumor. She had ultrasound and angiography that suggested hematoma. Surgical management was decided, during which it was observed that the tumor involved ulnar collateral digital artery of the fifth finger. The lesion and the arterial segment involved were resected. Post-surgical course without complications. The histopathological diagnosis of pseudoaneurysm of the lesion was confirmed.
DISCUSSION
traumatic etiology is the most frequent cause of digital aneurysms. Risk factors for pseudoaneurysms include sharp force trauma and alterations of the coagulation pathways, as in the case presented.
CONCLUSION
the pseudoaneurysm of a digital artery is a rare pathology with great variability of therapeutic management. Surgical resection of the lesion with vascular flow reconstruction is the recommended treatment.
Topics: Female; Humans; Aged; Aneurysm, False; Arteries; Aneurysm; Ultrasonography; Neoplasms
PubMed: 38052440
DOI: No ID Found -
Journal of Alzheimer's Disease Reports 2023Traditional methods for diagnosing dementia are costly, time-consuming, and somewhat invasive. Since the retina shares significant anatomical similarities with the...
BACKGROUND
Traditional methods for diagnosing dementia are costly, time-consuming, and somewhat invasive. Since the retina shares significant anatomical similarities with the brain, retinal abnormalities detected via optical coherence tomography (OCT) and OCT angiography (OCTA) have been studied as a potential non-invasive diagnostic tool for neurodegenerative disorders; however, the most effective retinal changes remain a mystery to be unraveled in this review.
OBJECTIVE
This study aims to explore the relationship between retinal abnormalities in OCT/OCTA images and cognitive decline as well as evaluating biomarkers' effectiveness in detecting neurodegenerative diseases.
METHODS
A systematic search was conducted on PubMed, Web of Science, and Scopus until December 2022, resulted in 64 papers using agreed search keywords, and inclusion/exclusion criteria.
RESULTS
The superior peripapillary retinal nerve fiber layer (pRNFL) is a trustworthy biomarker to identify most Alzheimer's disease (AD) cases; however, it is inefficient when dealing with mild AD and mild cognitive impairment (MCI). The global pRNFL (pRNFL-G) is another reliable biomarker to discriminate frontotemporal dementia from mild AD and healthy controls (HCs), moderate AD and MCI from HCs, as well as identifing pathological Aβ/tau in cognitively healthy individuals. Conversely, pRNFL-G fails to realize mild AD and the progression of AD. The average pRNFL thickness variation is considered a viable biomarker to monitor the progression of AD. Finally, the superior and average pRNFL thicknesses are considered consistent for advanced AD but not for early/mild AD.
CONCLUSIONS
Retinal changes may indicate dementia, but further research is needed to confirm the most effective biomarkers for early and mild AD.
PubMed: 38025800
DOI: 10.3233/ADR-230042 -
Acta Cardiologica Sinica Nov 2023The optimal strategy of percutaneous coronary intervention (PCI) for acute myocardial infarction (MI) complicated with cardiogenic shock (CS) remains controversial. We...
BACKGROUND
The optimal strategy of percutaneous coronary intervention (PCI) for acute myocardial infarction (MI) complicated with cardiogenic shock (CS) remains controversial. We aimed to elucidate the renal and cardiovascular impact of culprit-only (C) revascularization versus additional interventions on non-infarct-related arteries.
METHODS
PubMed, Embase, MEDLINE, and Cochrane Library were searched for relevant literature. A total of 96,812 subjects [C-PCI: 69,986; multi-vessel (MV)-PCI: 26,826] in nine studies (one randomized control trial; eight observational cohort studies) were enrolled.
RESULTS
MV-PCI was associated with a higher kidney event rate [relative risk (RR): 1.29, 95% confidence interval (CI): 1.12-1.49; p < 0.001]. However, the all-cause mortality rate was comparable both during admission (RR: 1.07, 95% CI: 0.94-1.22; p = 0.30) and at one year (RR: 0.96, 95% CI: 0.79-1.16; p = 0.65). MV-PCI was associated with a greater risk of stroke (RR: 1.19, 95% CI: 1.08-1.32; p < 0.001) and bleeding events (RR: 1.27, 95% CI: 1.07-1.51; p = 0.006), but reduced risk of recurrent MI (RR: 0.89, 95% CI: 0.82-0.97; p = 0.009) and repeat revascularization (RR: 0.34, 95% CI: 0.16-0.71; p = 0.004). No increased risk of coronary artery bypass grafting was present (RR: 1.09, 95% CI: 0.38-3.17; p = 0.87).
CONCLUSIONS
C-PCI was associated with a lower rate of renal dysfunction but not all-cause mortality in patients with CS complicating acute MI.
PubMed: 38022428
DOI: 10.6515/ACS.202311_39(6).20230307A -
Journal of the American Heart... Dec 2023Complex aortic plaque (CAP) is a potential embolic source in patients with cryptogenic stroke (CS). We review CAP imaging criteria for transesophageal echocardiogram...
BACKGROUND
Complex aortic plaque (CAP) is a potential embolic source in patients with cryptogenic stroke (CS). We review CAP imaging criteria for transesophageal echocardiogram (TEE), computed tomography angiography (CTA), and magnetic resonance imaging and calculate CAP prevalence in patients with acute CS.
METHODS AND RESULTS
PubMed and EMBASE databases were searched up to December 2022 in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guideline. Two independent reviewers extracted data on study design, imaging techniques, CAP criteria, and prevalence. The Cochrane Collaboration tool and Guideline for Reporting Reliability and Agreement Studies were used to assess risk of bias and reporting completeness, respectively. From 2293 studies, 45 were reviewed for CAP imaging biomarker criteria in patients with acute CS (N=37 TEE; N=9 CTA; N=6 magnetic resonance imaging). Most studies (74%) used ≥4 mm plaque thickness as the imaging criterion for CAP although ≥1 mm (N=1, CTA), ≥5 mm (N=5, TEE), and ≥6 mm (N=2, CTA) were also reported. Additional features included mobility, ulceration, thrombus, protrusions, and assessment of plaque composition. From 23 prospective studies, CAP was detected in 960 of 2778 patients with CS (0.32 [95% CI, 0.24-0.41], =94%). By modality, prevalence estimates were 0.29 (95% CI, 0.20-0.40; =95%) for TEE; 0.23 (95% CI, 0.15-0.34; =87%) for CTA and 0.22 (95% CI, 0.06-0.54; =92%) for magnetic resonance imaging.
CONCLUSIONS
TEE was commonly used to assess CAP in patients with CS. The most common CAP imaging biomarker was ≥4 mm plaque thickness. CAP was observed in one-third of patients with acute CS. However, high study heterogeneity suggests a need for reproducible imaging methods.
Topics: Humans; Brain Ischemia; Prevalence; Prospective Studies; Reproducibility of Results; Stroke; Plaque, Atherosclerotic; Ischemic Stroke; Biomarkers
PubMed: 38014682
DOI: 10.1161/JAHA.123.031797 -
Biomedicines Oct 2023Subarachnoid hemorrhage resulting from cerebral aneurysm rupture is a significant cause of morbidity and mortality. Early identification of aneurysms on Computed... (Review)
Review
Subarachnoid hemorrhage resulting from cerebral aneurysm rupture is a significant cause of morbidity and mortality. Early identification of aneurysms on Computed Tomography Angiography (CTA), a frequently used modality for this purpose, is crucial, and artificial intelligence (AI)-based algorithms can improve the detection rate and minimize the intra- and inter-rater variability. Thus, a systematic review and meta-analysis were conducted to assess the diagnostic accuracy of deep-learning-based AI algorithms in detecting cerebral aneurysms using CTA. PubMed (MEDLINE), Embase, and the Cochrane Library were searched from January 2015 to July 2023. Eligibility criteria involved studies using fully automated and semi-automatic deep-learning algorithms for detecting cerebral aneurysms on the CTA modality. Eligible studies were assessed using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines and the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. A diagnostic accuracy meta-analysis was conducted to estimate pooled lesion-level sensitivity, size-dependent lesion-level sensitivity, patient-level specificity, and the number of false positives per image. An enhanced FROC curve was utilized to facilitate comparisons between the studies. Fifteen eligible studies were assessed. The findings indicated that the methods exhibited high pooled sensitivity (0.87, 95% confidence interval: 0.835 to 0.91) in detecting intracranial aneurysms at the lesion level. Patient-level sensitivity was not reported due to the lack of a unified patient-level sensitivity definition. Only five studies involved a control group (healthy subjects), whereas two provided information on detection specificity. Moreover, the analysis of size-dependent sensitivity reported in eight studies revealed that the average sensitivity for small aneurysms (<3 mm) was rather low (0.56). The studies included in the analysis exhibited a high level of accuracy in detecting intracranial aneurysms larger than 3 mm in size. Nonetheless, there is a notable gap that necessitates increased attention and research focus on the detection of smaller aneurysms, the use of a common test dataset, and an evaluation of a consistent set of performance metrics.
PubMed: 38001922
DOI: 10.3390/biomedicines11112921 -
BMJ Open Ophthalmology Nov 2023To explore the current research about the role of optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA) in dysthyroid optic neuropathy... (Meta-Analysis)
Meta-Analysis
PURPOSE
To explore the current research about the role of optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA) in dysthyroid optic neuropathy (DON).
METHODS
Studies in the literature that focused on OCT, OCTA and DON were retrieved by searching PubMed, EMBASE, Cochrane databases and Clinical Trial before 20 June 2023. The methodological quality was assessed using the Newcastle-Ottawa scale. The quantitative calculation was performed using Review Manager V.5.3.
RESULTS
Twelve studies met the eligibility criteria and were included. DON group presented lower macular ganglion cell complex in the overall, superior and inferior hemifields compared with the non-DON group. Furthermore, the ganglion cell layer and inner plexiform layer in DON group was thinner in contrast to the non-DON group. The optic nerve head vessel density was lower in the DON group than that in the non-DON group. A reduction of radial peripapillary capillary vessel density could be seen in the DON group than the non-DON group in overall, inside disc, peripapillary, superior-hemifield, temporal and nasal. Besides, the macular superficial retinal capillary layer of non-DON and DON is lower than the healthy control group.
CONCLUSIONS
This study supported the potential value of OCT and OCTA metrics as novel biomarkers of DON. Ophthalmologists should comprehensively consider the retinal structure and microvasculature in dealing with DON.
ETHICS AND DISSEMINATION
This systematic review included data from published literature and was exempt from ethics approval. Results would be disseminated through peer-reviewed publication and presented at academic conferences engaging clinicians.
PROSPERO REGISTRATION NUMBER
CRD42023414907.
Topics: Humans; Tomography, Optical Coherence; Optic Disk; Angiography; Retinal Ganglion Cells; Optic Nerve Diseases
PubMed: 37996119
DOI: 10.1136/bmjophth-2023-001379 -
The Journal of Invasive Cardiology Nov 2023Previous studies show that the distal transradial approach (dTRA) is safe and effective for coronary angiography and percutaneous coronary intervention. However, the... (Meta-Analysis)
Meta-Analysis
OBJECTIVES
Previous studies show that the distal transradial approach (dTRA) is safe and effective for coronary angiography and percutaneous coronary intervention. However, the effect of dTRA on radiation exposure in the catheterization laboratory has not been characterized. The authors analyzed the available literature to compare the radiation exposure associated with dTRA vs the traditional radial approach (TRA).
METHODS
A systematic review and meta-analysis of the scientific literature was conducted by using relevant terms to search the PubMed, Embase, and Cochrane Library databases from their inception until October 13, 2022, to identify randomized controlled trials (RCTs) comparing dTRA with TRA. The primary outcome was radiation exposure reported as fluoroscopy time, air kerma, or kerma-dose product. The standard mean difference (SMD) and its 95% confidence interval were used to summarize continuous variables. Random effect and meta-regression also were used for analyses.
RESULTS
Among 484 studies identified, 7 were RCTs, with a total of 3427 patients (1712 dTRA, 1715 TRA). No difference was found between dTRA and TRA in radiation exposure quantified as fluoroscopy time (SMD -0.10 [-0.36, 0.15], P=.43) or air kerma (SMD -0.31 [-0.74, 0.13], P=.17). The overall estimate favored lower kerma-area product in the TRA (SMD 0.19 [0.08, 0.30], P=.0006). Meta-regression showed no correlation between fluoroscopy time and year of publication.
CONCLUSIONS
Compared with TRA, dTRA was associated with significantly greater radiation exposure per the kerma-area product during interventional cardiology procedures, with no differences in fluoroscopy time and air kerma.
Topics: Humans; Coronary Angiography; Cardiac Catheterization; Randomized Controlled Trials as Topic; Percutaneous Coronary Intervention; Radiation Exposure; Radial Artery
PubMed: 37992334
DOI: 10.25270/jic/23.00206