European Journal of Nuclear Medicine... Feb 2024Molecular imaging is pivotal in staging and response assessment of children with neuroblastoma (NB). [I]-metaiodobenzylguanidine (mIBG) is the standard imaging method;...
BACKGROUND
Molecular imaging is pivotal in staging and response assessment of children with neuroblastoma (NB). [I]-metaiodobenzylguanidine (mIBG) is the standard imaging method; however, it is characterised by low spatial resolution, time-consuming acquisition procedures and difficult interpretation. Many PET catecholaminergic radiotracers have been proposed as a replacement for [I]-mIBG, however they have not yet made it into clinical practice. We aimed to review the available literature comparing head-to-head [I]-mIBG with the most common PET catecholaminergic radiopharmaceuticals.
METHODS
We searched the PubMed database for studies performing a head-to-head comparison between [I]-mIBG and PET radiopharmaceuticals including meta-hydroxyephedrine ([C]C-HED), F-18F-3,4-dihydroxyphenylalanine ([F]DOPA) [I]mIBG and Meta-[18F]fluorobenzylguanidine ([F]mFBG). Review articles, preclinical studies, small case series (< 5 subjects), case reports, and articles not in English were excluded. From each study, the following characteristics were extracted: bibliographic information, technical parameters, and the sensitivity of the procedure according to a patient-based analysis (PBA) and a lesion-based analysis (LBA).
RESULTS
Ten studies were selected: two regarding [C]C-HED, four [F]DOPA, one [I]mIBG, and three [F]mFBG. These studies included 181 patients (range 5-46). For the PBA, the superiority of the PET method was reported in two out of ten studies (both using [F]DOPA). For LBA, PET detected significantly more lesions than scintigraphy in seven out of ten studies.
CONCLUSIONS
PET/CT using catecholaminergic tracers shows superior diagnostic performance than mIBG scintigraphy. However, it is still unknown if such superiority can influence clinical decision-making. Nonetheless, the PET examination appears promising for clinical practice as it offers faster image acquisition, less need for sedation, and a single-day examination.
Topics: Child; Humans; 3-Iodobenzylguanidine; Dihydroxyphenylalanine; Neuroblastoma; Positron Emission Tomography Computed Tomography; Positron-Emission Tomography; Radiopharmaceuticals
PubMed: 37962616
DOI: 10.1007/s00259-023-06486-9 -
Journal of Clinical Imaging Science 2023Young adults presenting with non-traumatic hip pain may suffer from acetabular retroversion (AR). The previous studies have suggested that patient positioning during the... (Review)
Review
Young adults presenting with non-traumatic hip pain may suffer from acetabular retroversion (AR). The previous studies have suggested that patient positioning during the radiographic procedure, that is, pelvic tilt and/or rotation may alter the appearance of the acetabulum. The purpose of this systematic review was to explore and collate existing literature on the correlation between pelvic positioning in weight-bearing anterior-posterior radiographs and the radiographic signs of AR, namely, the ischial spine sign (ISS) the cross-over sign (COS) and posterior wall sign (PWS). The preferred reporting items for systematic reviews and meta-analysis guidelines were followed. MEDLINE, EMBASE, PubMed, The Cochrane Library, and CINAHL were searched. The search string included the following keywords: Pelvic, tilt, rotation, positioning, inclination, incidence, AR, ISS, COS, PWS, and acetabular version. Two authors independently screened the studies identified in the search, extracted data, and critically assessed included studies for quality using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. In total, 2289 publications were screened. Fifteen articles were found eligible for full-text screening, and four articles met the inclusion criteria. Although the studies varied methodologically, all reported that pelvic positioning impacted radiographic signs of AR investigated. One study suggested that more than 9° of pelvic inclination would result in positive COS. No other benchmark values on the degree of pelvic tilt and rotation that would compromise the diagnosis of AR, that is, the detection of ISS, COS, and PWS were reported. At present, literature reporting on the correlation between patient positioning and AR is sparse. Four studies met the inclusion criteria, and they all reported a link between pelvic positioning and the radiographic appearance of AR.
PubMed: 37941923
DOI: 10.25259/JCIS_82_2023 -
Cureus Oct 2023Due to the clear depiction of facial aesthetics and other craniofacial parameters, portraiture photography (PP) is becoming more and more necessary in modern clinical... (Review)
Review
Due to the clear depiction of facial aesthetics and other craniofacial parameters, portraiture photography (PP) is becoming more and more necessary in modern clinical practice. The studies chosen for this review's inclusion looked at how PP affected the orthodontic treatment and diagnostic procedure on the subjects who were watched in the studies. Studies published within the last decade precisely from 2013 were searched for across major online databases after devising a proper search strategy. Multiple reviewers created a specific data extraction form that was used for the investigation, followed by the evaluation of bias and the variables found in each of the chosen papers. This form was meant for the assessment for various variables encountered in this study. According to the meta-analysis, using PP was related with a statistically significant decrease in the risk of orthodontic treatment and diagnostic modalities, with odds ratios (OR) of 0.52 with a 95% confidence interval (CI) of (0.28, 0.96), and a relative risk (RR) of 0.66 with a CI of (0.45, 0.96). In orthodontics, PP is an important tool that offers useful data for diagnosis, treatment planning, and tracking treatment success. To validate the results of studies like ours, a sizable evidence sample is required due to the limited number of trials that have been performed in this area.
PubMed: 37933372
DOI: 10.7759/cureus.48054 -
JSES Reviews, Reports, and Techniques Nov 2023Peripheral neuropathies after shoulder arthroscopy are rare, though likely under-reported. Many resolve spontaneously, but some patients are left with permanent... (Review)
Review
PURPOSE
Peripheral neuropathies after shoulder arthroscopy are rare, though likely under-reported. Many resolve spontaneously, but some patients are left with permanent neurological deficits. The purpose of this study was to review the literature to better characterize this patient population, diagnostic tests performed, the timing and type of surgical intervention, and report clinical outcomes.
METHODS
A systematic literature review was performed. Articles in English were identified from PubMed, EMBASE, and CINAHL in August 2021. Article titles and abstracts were screened for relevance by two authors and discordant abstracts were resolved by the senior author. Data were subsequently extracted from the included articles.
RESULTS
Seventeen articles were identified yielding a total of 91 patients. The average age was 53 ± 12 years, and most patients were male (72%). Rotator cuff repair (62%) was the most common procedure performed. A peripheral neuropathy was identified an average of 80 ± 81 days from the index procedure (range, 0-240 days). Most commonly, peripheral nerve injury presented as a mononeuropathy, with the median nerve (39%) and ulnar nerve (17%) affected predominantly. Seventeen percent of patients underwent a secondary surgery at an average of 232 ± 157 days after the index procedure. At the final follow-up, 55% of neuropathies had resolved, 14% partially improved, and 22% showed no clinical improvement. The most proposed etiologies were postoperative immobilization (29%) and intraoperative positioning (20%), but several possible etiologies have been suggested.
CONCLUSIONS
Peripheral neuropathies after arthroscopic shoulder procedures are rare. While most spontaneously resolve, up to 1 in 5 patients may have persistent neuropathic symptoms. A high index of suspicion should be maintained throughout the postoperative period. When neurologic deficits are identified, patients should undergo a thorough diagnostic workup and be referred to a subspecialist in a timely manner.
PubMed: 37928987
DOI: 10.1016/j.xrrt.2023.07.001 -
Medicine Oct 2023Medical infrared thermal imaging (IRT) has been applied to research blood flow, breast cancer detection, and human body muscle performance. The benefits of IRT include...
BACKGROUND
Medical infrared thermal imaging (IRT) has been applied to research blood flow, breast cancer detection, and human body muscle performance. The benefits of IRT include the fact that it is noninvasive, quick, dependable, non-contact, capable of creating several recordings in a short period of time, and secure for both patients and medical professionals. We aimed to determine the predictive value of IRT for identifying and evaluating any interventional procedure in patients affected by peripheral artery disease (PAD) of any severity.
METHODS
We searched the Cochrane Library, EMBASE, and PubMed on the topic of IRT and PAD until January 20,2023. We excluded gray literature as it is lacking credibility for not undergoing a peer-reviewed process. The search strategy includes the medical topic headings for "infrared thermal imaging" and "peripheral vascular disorders." The primary outcome of this systematic review was the variation in tissue perfusion in PAD patients. Each technique's technical characteristics and therapeutic use within PAD must be described in each included study.
RESULTS
This systematic review included 2 case reports and 3 observational studies. By comparing the temperatures of PAD patients hands, legs, and feet, IRT might prove to be an unduly valuable tool for treating vascular illnesses, especially in light of the knowledge gained from the temperature distribution maps.
CONCLUSION
This noninvasive method demonstrated encouraging results in the detection of various areas of foot perfusion and the screening of PAD, and it gave good findings in gauging the effects of any type of intervention.
Topics: Humans; Peripheral Arterial Disease; Lower Extremity; Foot; Hemodynamics; Thermography
PubMed: 37904481
DOI: 10.1097/MD.0000000000035639 -
The Medical Journal of Australia Dec 2023To review evaluations of the diagnostic accuracy of coronavirus disease 2019 (COVID-19) rapid antigen tests (RATs) approved by the Therapeutic Goods Administration (TGA)... (Review)
Review
COVID-19 rapid antigen tests approved for self-testing in Australia: published diagnostic test accuracy studies and manufacturer-supplied information. A systematic review.
OBJECTIVES
To review evaluations of the diagnostic accuracy of coronavirus disease 2019 (COVID-19) rapid antigen tests (RATs) approved by the Therapeutic Goods Administration (TGA) for self-testing by ambulatory people in Australia; to compare these estimates with values reported by test manufacturers.
STUDY DESIGN
Systematic review of publications in any language that reported cross-sectional, case-control, or cohort studies in which the participants were ambulatory people in the community or health care workers in hospitals in whom severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection was suspected, and the results of testing self-collected biological samples with a TGA-approved COVID-19 RAT were compared with those of reverse transcription-polymerase chain reaction (RT-PCR) testing for SARS-CoV-2. Estimates of diagnostic accuracy (sensitivity, specificity) were checked and compared with manufacturer estimates published on the TGA website.
DATA SOURCES
Publications (to 1 September 2022) identified in the Cochrane COVID-19 Study Register and the World Health Organization COVID-19 research database. Information on manufacturer diagnostic accuracy evaluations was obtained from the TGA website.
DATA SYNTHESIS
Twelve publications that reported a total of eighteen evaluations of eight RATs approved by the TGA for self-testing (manufacturers: All Test, Roche, Flowflex, MP Biomedicals, Clungene, Panbio, V-Chek, Whistling) were identified. Five studies were undertaken in the Netherlands, two each in Germany and the United States, and one each in Denmark, Belgium, and Canada; test sample collection was unsupervised in twelve studies, and supervised by health care workers or researchers in six. Estimated sensitivity with unsupervised sample collection ranged from 20.9% (MP Biomedicals) to 74.3% (Roche), and with supervised collection from 7.7% (V-Chek) to 84.4% (Panbio); the estimates were between 8.2 and 88 percentage points lower than the values reported by the manufacturers. Test specificity was high for all RATs (97.9-100%).
CONCLUSIONS
The risk of false negative results when using COVID-19 RATs for self-testing may be considerably higher than apparent in manufacturer reports on the TGA website, with implications for the reliability of these tests for ruling out infection.
Topics: Humans; COVID-19; SARS-CoV-2; Self-Testing; Cross-Sectional Studies; Reproducibility of Results; Sensitivity and Specificity; Diagnostic Tests, Routine; COVID-19 Testing
PubMed: 37903650
DOI: 10.5694/mja2.52151 -
Journal of Craniovertebral Junction &... 2023Extraskeletal chondromas (EC) are uncommon, benign cartilaginous tumours. Most common locations are upper and lower extremities. Location in the neck is extremely rare...
Extraskeletal chondromas (EC) are uncommon, benign cartilaginous tumours. Most common locations are upper and lower extremities. Location in the neck is extremely rare and reported only within the anterior compartment. Data are limited to just four case reports in the paediatric population. The first case of EC in neck's posterior compartment is described herein. EC present peculiar features on imaging. Aetiology is unclear; however, trauma has been suggested as possible causative mechanism. Treatment of choice is surgical excision; recurrence is not uncommon, but additional removal seems to be resolutive. All cases in literature were asymptomatic, except for one presenting respiratory stridor. The present patient suffered from neck functional limitation and upper limb hypoesthesia. Symptoms improved after surgery in both cases. Imaging follow-up at 6 months in the present case showed no sign of recurrence. ECs are rare, benign lesions. However, they may be preoperatively misinterpreted as more malignant counterparts (both radiologically or histologically), so accurate diagnostic work-up and planning of the surgical procedure are essential.
PubMed: 37860026
DOI: 10.4103/jcvjs.jcvjs_65_23 -
European Review For Medical and... Oct 2023There is an abundance of information on facelifts, blepharoplasties, rhinoplasty, and other cosmetic surgical procedures for the upper third of the face, but little is...
OBJECTIVE
There is an abundance of information on facelifts, blepharoplasties, rhinoplasty, and other cosmetic surgical procedures for the upper third of the face, but little is known about perioral lip rejuvenation. The aim of this article is to examine the existing literature on lip rejuvenation and perioral procedures related to lip rejuvenation. Additionally, this article aims to highlight the importance of addressing perioral areas alongside lip rejuvenation procedures, rather than solely focusing on lip rejuvenation. We also discussed the extensive procedures and materials used for lip rejuvenation, such as hyaluronic acid, botulinum toxin A, abobotulinum, onabotulinum, incobotulinum, prabobotulinum, fat grafts, silicone fillers, human collagen, collagen stimulating procedures such as derma pens and derma rolls, radiation frequency, stem cells, and plasma therapy, as well as the underlying factors that contribute to varying success rates.
MATERIALS AND METHODS
A thorough literature search was done using PubMed, Cochrane, Ebsco search, Google Scholar, Scopus, and Web of Science for the articles pertaining to facial and lip cosmetic surgeries 1995-2020. Keywords for the search included anatomy of the face, facial aging, perioral areas, lip rejuvenation, botox, grafts, facelift, plastic surgery, stem cell therapy, plasma treatment, and cosmetic surgery.
RESULTS
37 articles met the study criteria. 14 out of 37 studies included procedures for lip and perioral region rejuvenation. The remaining 23 studies either involved lip procedures alone or lip procedures in conjunction with facial cosmetic procedures. Lip rejuvenation with perioral enhancement with hyaluronic acid gel demonstrated a 94.3% improvement on the lip fullness scale (LFS) one month after re-treatment. The amalgamation of lip and perioral region rejuvenation produces a synergistic effect. Whereas, sole lip rejuvenation procedures showed short-term results with less patient satisfaction, calling for secondary lip rejuvenation procedures. It was also observed that hyaluronic acid was the most commonly used agent for lip rejuvenation procedures with minimal or no side effects.
CONCLUSIONS
In conjunction with perioral rejuvenation, lip rejuvenation procedures produce more aesthetically appealing results. However, any cosmetic surgical or non-surgical procedure is limited by the nature and composition of the products used. The use of FDA-approved products for rejuvenation is strongly advised to avoid undesirable side effects. Further extensive research is required on the long-term outcomes and adverse effects of stem cell transplants, such as tumor development.
Topics: Humans; Lip; Hyaluronic Acid; Cosmetic Techniques; Rejuvenation; Skin Aging; Collagen
PubMed: 37843317
DOI: 10.26355/eurrev_202310_33929 -
Health Technology Assessment... Jul 2023Magnetic resonance imaging-based technologies are non-invasive diagnostic tests that can be used to assess non-alcoholic fatty liver disease.
BACKGROUND
Magnetic resonance imaging-based technologies are non-invasive diagnostic tests that can be used to assess non-alcoholic fatty liver disease.
OBJECTIVES
The study objectives were to assess the diagnostic test accuracy, clinical impact and cost-effectiveness of two magnetic resonance imaging-based technologies (LiverMultiScan and magnetic resonance elastography) for patients with non-alcoholic fatty liver disease for whom advanced fibrosis or cirrhosis had not been diagnosed and who had indeterminate results from fibrosis testing, or for whom transient elastography or acoustic radiation force impulse was unsuitable, or who had discordant results from fibrosis testing.
DATA SOURCES
The data sources searched were MEDLINE, MEDLINE Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects and the Health Technology Assessment.
METHODS
A systematic review was conducted using established methods. Diagnostic test accuracy estimates were calculated using bivariate models and a summary receiver operating characteristic curve was calculated using a hierarchical model. A simple decision-tree model was developed to generate cost-effectiveness results.
RESULTS
The diagnostic test accuracy review (13 studies) and the clinical impact review (11 studies) only included one study that provided evidence for patients who had indeterminate or discordant results from fibrosis testing. No studies of patients for whom transient elastography or acoustic radiation force impulse were unsuitable were identified. Depending on fibrosis level, relevant published LiverMultiScan diagnostic test accuracy results ranged from 50% to 88% (sensitivity) and from 42% to 75% (specificity). No magnetic resonance elastography diagnostic test accuracy data were available for the specific population of interest. Results from the clinical impact review suggested that acceptability of LiverMultiScan was generally positive. To explore how the decision to proceed to biopsy is influenced by magnetic resonance imaging-based technologies, the External Assessment Group presented cost-effectiveness analyses for LiverMultiScan plus biopsy versus biopsy only. Base-case incremental cost-effectiveness ratio per quality-adjusted life year gained results for seven of the eight diagnostic test strategies considered showed that LiverMultiScan plus biopsy was dominated by biopsy only; for the remaining strategy (Brunt grade ≥2), the incremental cost-effectiveness ratio per quality-adjusted life year gained was £1,266,511. Results from threshold and scenario analyses demonstrated that External Assessment Group base-case results were robust to plausible variations in the magnitude of key parameters.
LIMITATIONS
Diagnostic test accuracy, clinical impact and cost-effectiveness data for magnetic resonance imaging-based technologies for the population that is the focus of this assessment were limited.
CONCLUSIONS
Magnetic resonance imaging-based technologies may be useful to identify patients who may benefit from additional testing in the form of liver biopsy and those for whom this additional testing may not be necessary. However, there is a paucity of diagnostic test accuracy and clinical impact data for patients who have indeterminate results from fibrosis testing, for whom transient elastography or acoustic radiation force impulse are unsuitable or who had discordant results from fibrosis testing. Given the External Assessment Group cost-effectiveness analyses assumptions, the use of LiverMultiScan and magnetic resonance elastography for assessing non-alcoholic fatty liver disease for patients with inconclusive results from previous fibrosis testing is unlikely to be a cost-effective use of National Health Service resources compared with liver biopsy only.
STUDY REGISTRATION
This study is registered as PROSPERO CRD42021286891.
FUNDING
Funding for this study was provided by the Evidence Synthesis Programme of the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme and will be published in full in ; Vol. 27, No. 10. See the NIHR Journals Library website for further project information.
Topics: Humans; Cost-Benefit Analysis; Liver Cirrhosis; Magnetic Resonance Imaging; Non-alcoholic Fatty Liver Disease; State Medicine
PubMed: 37839810
DOI: 10.3310/KGJU3398 -
International Journal of Surgery... Feb 2024Good nutritional screening tests can triage malnourished patients for further assessment and management by dietitians before surgery to reduce the risk of postoperative... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Good nutritional screening tests can triage malnourished patients for further assessment and management by dietitians before surgery to reduce the risk of postoperative complications. The authors assessed the diagnostic test accuracy of common nutritional screening tools for preoperative malnutrition in adults undergoing surgery and determined which test had the highest accuracy.
METHODS
MEDLINE, EMBASE, CINAHL, and Web of Science were searched for relevant titles with no language restriction from inception till 1 January 2023. Studies reporting on the diagnostic test accuracy of preoperative malnutrition in adults using one or more of the following index nutritional screening tools were included: Malnutrition Screening Tool (MST), Malnutrition Universal Screening Tool (MUST), Mini Nutritional Assessment (MNA), short-form Mini Nutritional Assessment (MNA-SF), Nutritional Risk Index (NRI), Nutrition Risk Screening Tool 2002 (NRS-2002), and Preoperative Nutrition Screening (PONS). The reference standard was the Subjective Global Assessment (SGA) before surgery. Random-effects bivariate binomial model meta-analyses, meta-regressions, and a network meta-analysis were used to estimate the pooled and relative sensitivities and specificities.
RESULTS
Of the 16 included studies (5695 participants with an 11 957 index and 11 957 SGA tests), all were conducted after hospital admission before surgery. Eleven studies ( n =3896) were at high risk of bias using the Quality Assessment of Diagnostic Accuracy Studies tool due to a lack of blinded assessments. MUST had the highest overall test accuracy performance (sensitivity 86%, 95% CI: 75-93%; specificity 89%, 95% CI: 83-93%). Network meta-analysis showed NRI had similar relative sensitivity (0.93, 95% CI: 0.77-1.13) but lower relative specificity (0.75, 95% CI: 0.61-0.92) than MUST.
CONCLUSIONS
Of all easy-to-use tests applicable at the bedside, MUST had the highest test accuracy performance for screening preoperative malnutrition. However, its predictive accuracy is likely insufficient to justify the application of nutritional optimization interventions without additional assessments.
Topics: Adult; Humans; Nutritional Status; Nutrition Assessment; Network Meta-Analysis; Malnutrition; Mass Screening; Diagnostic Tests, Routine
PubMed: 37830947
DOI: 10.1097/JS9.0000000000000845