Chinese Journal of Traumatology =... Apr 2024To methodically assess the effectiveness of augmentative plating (AP) and exchange nailing (EN) in managing nonunion following intramedullary nailing for long bone...
Effectiveness and safety of augmentative plating technique in managing nonunion following intramedullary nailing of long bones in the lower extremity: A systematic review and meta-analysis.
PURPOSE
To methodically assess the effectiveness of augmentative plating (AP) and exchange nailing (EN) in managing nonunion following intramedullary nailing for long bone fractures of the lower extremity.
METHODS
PubMed, EMBASE, Web of Science, and the Cochrane Library were searched to gather clinical studies regarding the use of AP and EN techniques in the treatment of nonunion following intramedullary nailing of lower extremity long bones. The search was conducted up until May 2023. The original studies underwent an independent assessment of their quality, a process conducted utilizing the Newcastle-Ottawa scale. Data were retrieved from these studies, and meta-analysis was executed utilizing Review Manager 5.3.
RESULTS
This meta-analysis included 8 studies involving 661 participants, with 305 in the AP group and 356 in the EN group. The results of the meta-analysis demonstrated that the AP group exhibited a higher rate of union (odds ratio: 8.61, 95% confidence intervals (CI): 4.12 - 17.99, p < 0.001), shorter union time (standardized mean difference (SMD): -1.08, 95 % CI: -1.79 - -0.37, p = 0.003), reduced duration of the surgical procedure (SMD: -0.56, 95 % CI: -0.93 - -0.19, p = 0.003), less bleeding (SMD: -1.5, 95 % CI: -2.81 - -0.18), p = 0.03), and a lower incidence of complications (relative risk: -0.17, 95 % CI: -0.27 - -0.06, p = 0.001). In the subgroup analysis, the time for union in the AP group in nonisthmal and isthmal nonunion of lower extremity long bones was shorter compared to the EN group (nonisthmal SMD: -1.94, 95 % CI: -3.28 - -0.61, p < 0.001; isthmal SMD: -1.08, 95 % CI: -1.64 - -0.52, p = 0.002).
CONCLUSION
In the treatment of nonunion in diaphyseal fractures of the long bones in the lower extremity, the AP approach is superior to EN, both intraoperatively (with reduced duration of the surgical procedure and diminished blood loss) and postoperatively (with an elevated union rate, shorter union time, and lower incidence of complications). Specifically, in the management of nonunion of lower extremity long bones with non-isthmal and isthmal intramedullary nails, AP demonstrated shorter union time in comparison to EN.
PubMed: 38762419
DOI: 10.1016/j.cjtee.2024.04.004 -
Journal of Orthopaedics and... Apr 2024The purpose of this systematic review is to examine the outcomes, complications, and potential advantages of using anatomical interlocking intramedullary nails (IMN) in... (Meta-Analysis)
Meta-Analysis
PURPOSE
The purpose of this systematic review is to examine the outcomes, complications, and potential advantages of using anatomical interlocking intramedullary nails (IMN) in the treatment of radius and ulnar shaft diaphyseal fractures in adults.
METHODS
Medline, Embase, Web of Science, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases were searched between January 2000 and January 2023. Studies meeting criteria were observational or randomized controlled trials evaluating outcomes in IMN for adult diaphyseal forearm fractures. Standardized data extraction was performed and a quality assessment tool was used to evaluate individual study methodology. Descriptive statistics for interventions, functional outcomes, and complications were reported. Meta-analysis was performed for patient-reported outcome measures and operative time.
RESULTS
A total of 29 studies involving 1268 patients were included with 764 (60%) undergoing IMN, 21% open reduction and internal fixation (ORIF), and 9% hybrid fixation. There was no significant difference between groups in DASH and Grace-Eversmann scores. Operative time was significantly shorter in IMN compared with ORIF. The DASH scores were: 13.1 ± 6.04 for IMN, 10.17 ± 3.98 for ORIF, and 15.5 ± 0.63 in hybrids. Mean operative time was 65.3 ± 28.7 in ORIF and 50.8 ± 17.7 in IMN. Complication rates were 16.7% in the IMN group, 14.9% in ORIF, and 6.3% in hybrid constructs. There were 11 cases of extensor pollicis rupture in the IMN group. Average IMN pronation and supination were 78.3° ± 7.9° and 73° ± 5.0°, respectively. Average ORIF pronation and supination was 82.15° ± 1.9° and 79.7° ± 4.5°, respectively.
CONCLUSIONS
Similar functional outcomes and complication rates along with shorter operative times can be achieved with IMN compared with ORIF. The use of IMN is promising, however, higher quality evidence is required to assess appropriate indications, subtle differences in range of motion, implant-related complications, and cost-effectiveness. Trail Registration PROSPERO (International Prospective Register of Systematic Reviews) (ID: CRD42022362353).
Topics: Adult; Humans; Forearm; Internal Fixators; Fractures, Bone; Fracture Fixation, Intramedullary; Ulna Fractures; Forearm Injuries; Postoperative Complications
PubMed: 38615140
DOI: 10.1186/s10195-024-00761-7 -
Medicine Apr 2024Blocking screw technique has been widely applied in the treatment of long shaft fractures. However, the evidence with regard to whether intramedullary nail combined with... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Blocking screw technique has been widely applied in the treatment of long shaft fractures. However, the evidence with regard to whether intramedullary nail combined with blocking screw technique has better clinical efficacy over other is not clear. The aim of the study was to explore the clinical efficacy and complications of intramedullary nail combined with blocking screw technique in the treatment of femoral or tibial shaft fractures.
METHODS
The PuMed, Embase, OVID, Cochrane library, Web of Science, Wanfang, CNKI and Weipu data were searched for studies of intramedullary nail combined with blocking screw in treatment of femoral or tibial shaft fracture published up to Aug 31 2023. Methodological quality of the trials was assessed, relevant data were extracted, and RevMan 5.3 and Stata 15.0 software were used to perform the meta-analysis of parameters related to the consequences.
RESULT
Twenty articles were included, including 1267 patients. Meta-analysis results showed that compared with the non-blocking screw group, the blocking screw group had longer operation time (WMD = 13.24; 95% CI = 5.68-20.79, P = .0006) and more intraoperative fluoroscopy times (WMD = 57.62; 95% CI = 25.82-89.42, P = .0002). However, the postoperative therapeutic response rate was higher (OR = 5.60; 95% CI = 2.10-14.93, P = .0006), postoperative ankle joint function was better (OR = 3.48; 95% CI = 1.20-10.13, P = .02), and fracture healing rate was higher (OR = 3.56; 95% CI = 1.43-8.89, P = .006), fracture healing time was shorter (WMD = -3.59; 95% CI = -4.96 to -2.22, P < .00001), intraoperative blood loss was less (WMD = -54.80; 95% CI = -88.77 to -20.83, P = .002), hospitalization time was shorter (WMD = -1.66; 95% CI = -2.08 to -1.24, P < .00001), and complications were less (OR = 0.38; 95% CI = 0.16-0.89, P = .01). There was no statistical significance in the range of motion of knee joint between the 2 groups (WMD = 10.04; 95% CI = -1.51 to 21.59, P = .09).
CONCLUSIONS
Current evidence shows that intramedullary nail combined with blocking screw technique in the treatment of lower limb long bone fracture has the advantages of good clinical efficacy, high fracture healing rate, short fracture healing time, good joint function, less complications and so on, which is worthy of clinical recommendation.
Topics: Humans; Fracture Fixation, Intramedullary; Bone Screws; Treatment Outcome; Tibial Fractures; Lower Extremity; Bone Nails
PubMed: 38579094
DOI: 10.1097/MD.0000000000037647 -
BMC Musculoskeletal Disorders Mar 2024To compare the postoperative rehabilitation of femoral neck fractures treated with robot-assisted nailing and freehand nailing. (Meta-Analysis)
Meta-Analysis
PURPOSE
To compare the postoperative rehabilitation of femoral neck fractures treated with robot-assisted nailing and freehand nailing.
METHODS
We systematically searched the PubMed, EMBASE, Cochrane, China National Knowledge Infrastructure(CNKI), WanFang database, China Science and Technology Journal Database (VIP) and Web of Science databases to identify potentially eligible articles. Indispensable data such as the year of publication, country, study type, robot type, age, number of patients, sex distribution, study design, and outcome indicators were extracted. The outcome indicators of interest included healing rate, length of healing time, Harris score, operation time, frequency of X-ray fluoroscopy, frequency of guide pin insertion, and intraoperative blood loss. RevMan 5.4.1 was used for the meta-analysis.
RESULTS
Fourteen studies with 908 participants were included in this meta-analysis. The results showed that in terms of healing rate (SMD = 2.75, 95% CI, 1.03 to 7.32, P = 0.04) and Harris score (SMD = 2.27, 95% CI, 0.79 to 3.75, P = 0.003), robot-assisted screw placement technique scores were higher than the traditional freehand technique. Additionally, operative time (SMD = -12.72, 95% CI, -19.74 to -5.70, P = 0.0004), healing time (SMD = -13.63, 95% CI, -20.18 to -7.08, P < 0.0001), frequency of X-ray fluoroscopy (SMD = - 13.64, 95% CI, - 18.32 to - 8.95, P < 0.00001), frequency of guide pin insertion (SMD = - 7.95, 95% CI, - 10.13 to - 5.76, P < 0.00001), and intraoperative blood loss (SMD = - 17.33, 95% CI, - 23.66 to - 11.00, P < 0.00001) were lower for patients who underwent robotic-assisted screw placement than those for patients who underwent the conventional freehand technique.
CONCLUSION
Compared to the freehand nailing technique, robot-assisted nailing helps improve postoperative healing rates in patients with femoral neck fractures; shortens healing times; better restores hip function; reduces the number of intraoperative fluoroscopies, guides pin placements; reduces intraoperative bleeding; and increases perioperative safety.
Topics: Humans; Blood Loss, Surgical; Bone Screws; Femoral Neck Fractures; Retrospective Studies; Robotic Surgical Procedures; Treatment Outcome
PubMed: 38459524
DOI: 10.1186/s12891-024-07325-0 -
Journal of the Mechanical Behavior of... May 2024This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation...
INTRODUCTION
This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation constructs.
METHODS
A systematic literature search was conducted to include biomechanical studies and to exclude clinical trials.
RESULTS
Of an initial 4666 studies found, 38 met the inclusion criteria. 84% of the included studies were retrieved from PubMed, Scopus, and Web of Science. The studies analysed 106 postmortem specimens, 154 synthetic bones, and 103 computational models. Most specimens were male (97% synthetic, 70% postmortem specimens). Both the type of injury and the classification system employed varied across studies. About 82% of the injuries assessed were of type C. Two different fixators were tested for FFPII and type A injury, five for type B injury, and fifteen for type C injury. Large variability was observed for external fixation constructs concerning device type and configuration, pin size, and geometry. Biomechanical studies deployed various methods to assess injury displacement, deformation, stiffness, and motion. Thereby, loading protocols differed and inconsistent definitions of failure were determined. Measurement techniques applied in biomechanical test setups included strain gauges, force transducers, and motion tracking techniques.
DISCUSSION AND CONCLUSION
An ideal fixation method should be safe, stable, non-obstructive, and have low complication rates. Although biomechanical testing should ensure that the load applied during testing is representative of a physiological load, a high degree of variability was found in the current literature in both the loading and measurement equipment. The lack of a standardised test design for fixation constructs in pelvic injuries across the studies challenges comparisons between them. When interpreting the results of biomechanical studies, it seems crucial to consider the limitations in cross-study comparability, with implications on their applicability to the clinical setting.
Topics: Humans; Biomechanical Phenomena; External Fixators; Fracture Fixation; Fractures, Bone; Pelvic Bones
PubMed: 38437754
DOI: 10.1016/j.jmbbm.2024.106488 -
Archives of Orthopaedic and Trauma... Mar 2024The aim of this systematic review was to compare extramedullary fixation and intramedullary fixation for AO type 31-A2 trochanteric fractures in the elderly, with regard... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
The aim of this systematic review was to compare extramedullary fixation and intramedullary fixation for AO type 31-A2 trochanteric fractures in the elderly, with regard to functional outcomes, complications, surgical outcomes, and costs.
METHODS
Embase, Medline, Web of Science, Cochrane Central Register of Controlled Trials, and Google Scholar were searched for randomized controlled trials (RCTs) and observational studies. Effect estimates were pooled across studies using random effects models. Results are presented as weighted risk ratio (RR) or weighted mean difference (MD) with corresponding 95% confidence interval (95% CI).
RESULTS
Fourteen RCTs (2039 patients) and 13 observational studies (22,123 patients) were included. Statistically superior results in favor of intramedullary fixation were found for Harris Hip Score (MD 4.09, 95% CI 0.91-7.26, p = 0.04), Parker mobility score (MD - 0.67 95% CI - 1.2 to - 0.17, p = 0.009), lower extremity measure (MD - 4.07 95% CI - 7.4 to - 0.8, p = 0.02), time to full weight bearing (MD 1.14 weeks CI 0.92-1.35, p < 0.001), superficial infection (RR 2.06, 95% CI 1.18-3.58, p = 0.01), nonunion (RR 3.67, 95% CI 1.03-13.10, p = 0.05), fixation failure (RR 2.26, 95% CI 1.16-4.44, p = 0.02), leg shortening (MD 2.23 mm, 95% CI 0.81-3.65, p = 0.002), time to radiological bone healing (MD 2.19 months, 95% CI 0.56-3.83, p = 0.009), surgery duration (MD 11.63 min, 95% CI 2.63-20.62, p = 0.01), operative blood loss (MD 134.5 mL, 95% CI 51-218, p = 0.002), and tip-apex distance > 25 mm (RR 1.73, 95% CI 1.10-2.74, p = 0.02). No comparable cost/costs-effectiveness data were available.
CONCLUSION
Current literature shows that several functional outcomes, complications, and surgical outcomes were statistically in favor of intramedullary fixation when compared with extramedullary fixation of AO/OTA 31-A2 fractures. However, as several of the differences found appear not to be clinically relevant and for many outcomes data remains sparse or heterogeneous, complete superiority of IM fixation for AO type 31-A2 fractures remains to be confirmed in a detailed cost-effectiveness analysis.
Topics: Humans; Aged; Bone Nails; Fracture Fixation, Intramedullary; Hip Fractures; Fracture Fixation, Internal
PubMed: 38175213
DOI: 10.1007/s00402-023-05138-9 -
Journal of Back and Musculoskeletal... 2024Central sensitization cannot be demonstrated directly in humans. Therefore, studies used different proxy markers (signs, symptoms and tools) to identify factors assumed... (Review)
Review
BACKGROUND
Central sensitization cannot be demonstrated directly in humans. Therefore, studies used different proxy markers (signs, symptoms and tools) to identify factors assumed to relate to central sensitization in humans, that is, Human Assumed Central Sensitization (HACS). The aims of this systematic review were to identify non-invasive objective markers of HACS and the instruments to assess these markers in patients with fibromyalgia (FM).
METHODS
A systematic review was conducted with the following inclusion criteria: (1) adults, (2) diagnosed with FM, and (3) markers and instruments for HACS had to be non-invasive. Data were subsequently extracted, and studies were assessed for risk of bias using the quality assessment tools developed by the National Institute of Health.
RESULTS
78 studies (n= 5234 participants) were included and the findings were categorized in markers identified to assess peripheral and central manifestations of HACS. The identified markers for peripheral manifestations of HACS, with at least moderate evidence, were pain after-sensation decline rates, mechanical pain thresholds, pressure pain threshold, sound 'pressure' pain threshold, cutaneous silent period, slowly repeated evoked pain sensitization and nociceptive flexion reflex threshold. The identified markers for central manifestations of HACS were efficacy of conditioned pain modulation with pressure pain conditioning and brain perfusion analysis. Instruments to assess these markers are: pin-prick stimulators, cuff-algometry, repetitive pressure stimulation using a pressure algometer, sound, electrodes and neuroimaging techniques.
CONCLUSIONS
This review provides an overview of non-invasive markers and instruments for the assessment of HACS in patients with FM. Implementing these findings into clinical settings may help to identify HACS in patients with FM.
Topics: Fibromyalgia; Humans; Central Nervous System Sensitization; Pain Threshold; Biomarkers; Pain Measurement
PubMed: 38073369
DOI: 10.3233/BMR-220430 -
BMC Musculoskeletal Disorders Nov 2023Ilizarov method has become one of primary methods for treating bone defects. Currently, there is growing trend in the application of modified Ilizarov methods (e.g.,... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Ilizarov method has become one of primary methods for treating bone defects. Currently, there is growing trend in the application of modified Ilizarov methods (e.g., applying unilateral external fixators or with flap tissue) and its combined methods (e.g., Ilizarov method with antibiotic spacer or internal fixation) to manage bone defects. However, there is a lack of studies with systematical evaluation of the clinical effects of these evolving methods. This study aimed to conduct a systematic review and meta-analysis for overall evaluating the clinical effects on long bone defects of lower extremity in Ilizarov methods and its combined methods.
METHODS
Studies were identified in three electronic databases (Pubmed, Embase and Cochrane Library) from the earliest indexing year through November 01, 2022, and relevant data were extracted subsequently. The total number of participants, number of participants with bone unions, bone result or functional result, and related complications including pin infection, pin loosening, pain, refracture, limb discrepancy, malalignment, joint stiffness, recurrent infection, and amputation were extracted in this study. Then, union rate (defined as the proportion of patients who achieved bone unions) and specific complication incidence rate (defined as the proportion of patients who experienced specific complication) were pooled estimated respectively. Relative risk (RR) was used for comparing the clinical effects among various Ilizarov technique.
RESULTS
Sixty-eight case series studies, 29 comparative studies, and 3 randomized clinical trials were finally included. The union rate of Ilizarov methods was 99.29% (95% CI: 98.67% ~ 99.86%) in tibial defects and 98.81% (95% CI: 98.81% ~ 100.00%) in femoral defects. The union rate of Ilizarov method with antibiotic spacer and intramedullary nail in tibial defects was 99.58% (95% CI: 98.05% ~ 100.00%) and 95.02% (95% CI: 87.28% ~ 100.00%), respectively. Compared to the Ilizarov methods, the union rate of the Ilizarov method with antibiotic spacer in tibial defects increased slightly (RR = 1.02, 95% CI: 1.01 ~ 1.04). Meanwhile, compared to Ilizarov methods, we found lower excellent rate in bone result in Ilizarov method with antibiotic spacer, with the moderate to high heterogeneity. Compared to the Ilizarov method, lower rate of pin infection, higher rate of recurrent infection and amputation were observed in Ilizarov method with intramedullary nail, however, the findings about the comparison of pin infection and recurrent infection between the two groups were presented with high degree of statistical heterogeneity.
CONCLUSION
Our study confirmed the reliable treatment of Ilizarov methods and its combined technique on long bone defects, and founded there were significant differences on some complications rate between Ilizarov methods and its combined technique. However, the findings need to be confirmed by further studies.
Topics: Humans; Ilizarov Technique; Reinfection; Treatment Outcome; Tibia; External Fixators; Lower Extremity; Anti-Bacterial Agents; Retrospective Studies; Tibial Fractures
PubMed: 37968675
DOI: 10.1186/s12891-023-07001-9 -
BMC Musculoskeletal Disorders Oct 2023There is no consensus on the optimal treatment for ipsilateral femoral neck and shaft fractures. This meta-analysis aims to assess the effectiveness of reconstruction... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
There is no consensus on the optimal treatment for ipsilateral femoral neck and shaft fractures. This meta-analysis aims to assess the effectiveness of reconstruction nails and dual implants in treating ipsilateral femoral neck and shaft fractures to provide a basis for decision-making when selecting the optimal approach.
METHODS
Relevant articles were retrieved from Pubmed, Embase, and Cochrane databases using the keywords "neck of femur", "shaft" and "fracture fixation" from inception until November 17, 2022. The screening process of the studies was conducted independently by two assessors, who assessed each study's eligibility and two assessors assessed the quality. Then compared differences in outcome measures using RevMan 5.3 software.
RESULTS
A total of ten retrospective cohort studies were included. There were no significant differences in union time, union rate, union-related complications (malunion, nonunion, delayed union) of femoral neck and shaft fractures, osteonecrosis of the femoral head, and functional outcomes (Friedman-Wyman scoring system) (P > 0.05).
CONCLUSION
Our pooled estimates indicated that reconstruction nails and dual implants for ipsilateral femoral neck and shaft fractures could yield satisfactory surgical results, and that there is no difference between the two treatment methods.
TRIAL REGISTRATION
This meta-analysis was registered on the PROSPERO website (registration number: CRD42022379606).
Topics: Adult; Humans; Femoral Neck Fractures; Femur Neck; Femoral Fractures; Retrospective Studies; Nails; Fracture Fixation, Intramedullary; Bone Nails; Treatment Outcome
PubMed: 37814281
DOI: 10.1186/s12891-023-06933-6 -
Medicine Sep 2023Studies of clinical outcomes that compare the elastic stable intramedullary nail (ESIN) with the submuscular plate (SMP) were controversial. The meta-analysis was... (Meta-Analysis)
Meta-Analysis
Elastic stable intramedullary nail fixation versus submuscular plate fixation of pediatric femur shaft fractures in school age patients: A PRISMA-compliant systematic review and meta-analysis.
BACKGROUND
Studies of clinical outcomes that compare the elastic stable intramedullary nail (ESIN) with the submuscular plate (SMP) were controversial. The meta-analysis was performed to summarize existing evidence, aiming to determine whether ESIN was superior to SMP in pediatric femur shaft fractures.
METHODS
Search strategies followed the recommendations of the Cochrane collaboration. Electronic searches such as PubMed, Embase, Web of Science, Cochrane were systematically searched for publications concerning ESIN and SMP from the inception date to March 2023. Two investigators independently searched, screened, and reviewed the full text of the article. Disagreements generated throughout the process were resolved by consensus, and if divergences remain, they were arbitrated by a third author.
RESULTS
This study included 8 articles, comprising a total of 561 patients with a similar baseline. Compared to the SMP, the ESIN had shorter operation time (mean difference = -16.16; 95% CI = -22.83 to -9.48, P < .00001), and less intraoperative blood loss (mean difference = -53.62; 95% CI = -58.89 to -48.36, P < .00001), but had a higher incidence of implant irritation (odds ratio [OR] = 6.49; 95% CI = 3.01 to 13.98, P < .0001), lower limb malalignment (OR = 2.60; 95% CI = 1.12 to 6.04, P = .96) and overall complications(OR = 4.14; 95% CI = 2.51 to 6.84, P < .0001). And there was no significant difference in radiation time, length of hospital stay, limb length discrepancy, infection rate, delayed union rate and unplanned revised surgery rate (P > .05).
CONCLUSIONS
Compared to the SMP, the ESIN offers shorter operative time, and less blood loss. However, the SMP is superior to ESINs in complication rates, especially regarding implant irritation and malalignment. Both methods could achieve excellent satisfactory functional outcomes. Thus, the SMP is an alternative choice in the pediatric femur shaft fracture.
Topics: Humans; Child; Femoral Fractures; Fracture Fixation, Intramedullary; Bone Plates; Blood Loss, Surgical; Femur; Bone Nails; Treatment Outcome
PubMed: 37773849
DOI: 10.1097/MD.0000000000035287