-
Acta Cirurgica Brasileira 2023To conduct a systematic review of nanoparticles' use in the treatment of prostate cancer in animals.
PURPOSE
To conduct a systematic review of nanoparticles' use in the treatment of prostate cancer in animals.
METHODS
A systematic review was conducted in the databases PubMed, Scientific Electronic Library Online (SciELO), Latin American and Caribbean Health Sciences Literature (LILACS), Cochrane Library, and EMBASE, and the descriptors were chosen based on terms indexed in Health Sciences Descriptors (DeCS)/Medical Subject Headings (MESH), which are: nanoparticles, nanomedicine, and prostate cancer. The systematic review protocol was registered in the International Prospective Register of Systematic Reviews (PROSPERO) with ID CRD42021271008.
RESULTS
A total of 3,897 articles was chosen; after reading the inclusion and exclusion criteria, six scientific articles with themes involving nanoparticles carrying medications were reached. Among the nanoparticles found, there were carboxymethylcellulose polymer, micellar casein nanoparticles, liquid crystal nanoparticles, serum albumin nanoparticles, and poly(ethylene glycol)-block-polylactide (mPEG-PLA) conjugated nanoparticles encapsulating cabazitaxel, docetaxel, and flutamide, which were nanoparticles used to treat prostate cancer in animals.
CONCLUSIONS
Through using nanoparticles to encapsulate medications for treating prostate cancer in animals, studies show a decrease in weight and tumor reduction, with nanoparticles resulting in greater survival time than free medications. The improved permeability and retention effect of nanoparticles in the bloodstream contribute to their effectiveness.
Topics: Animals; Humans; Male; Docetaxel; Models, Animal; Nanoparticles; Prostatic Neoplasms
PubMed: 37909596
DOI: 10.1590/acb385923 -
Journal of Environmental Health Science... Dec 2023Pollution of the environment with all kinds of plastics has become a growing problem. The problem of microplastics is mainly due to the absorption of stable organic...
PURPOSE
Pollution of the environment with all kinds of plastics has become a growing problem. The problem of microplastics is mainly due to the absorption of stable organic pollutants and metals into them, and as a result, their environmental toxicity increases. The main purpose of this study is to investigate the appropriate and efficient methods of removing microplastics from aqueous environments through a systematic review.
METHODS
Present study designed according to PRISMA guidelines. Two independent researchers followed all process from search to final analysis, for the relevant studies using international databases of PubMed, Scopus and ISI/WOS (Web of Science), without time limit. The search strategy developed based on the main axis of "microplastics", "aqueous environments" and "removal". This research was carried out from 2017 until the March of 2022. All relevant observational, analytical studies, review articles, and a meta-analysis were included.
RESULTS
Through a comprehensive systematic search we found 2974 papers, after running the proses of refining, 80 eligible papers included to the study. According to the results of the review, the methods of removing microplastics from aquatic environments were divided to physical (12), chemical (18), physicochemical (27), biological (12) and integrated (11) methods. In different removal methods, the most dominant group of studied microplastics belonged to the four groups of polyethylene (PE), polystyrene (PS), polypropylene (PP) and polyethylene tetra phthalate (PET). Average removal efficiency of microplastics in different processes in each method was as: physical method (73.76%), chemical method (74.38%), physicochemical method (80.44%), biological method (75.23%) and integrated method (88.63%). The highest removal efficiency occurred in the processes based on the integrated method and the lowest efficiency occurred in the physical method. In total, 80% of the studies were conducted on a laboratory scale, 18.75% on a full scale and 1.25% on a pilot scale.
CONCLUSION
According to the findings; different processes based on physical, chemical, physicochemical, biological and integrated methods are able to remove microplastics with high efficiency from aqueous environments and in order to reduce their hazardous effects on health and environment, these processes can be easily used.
PubMed: 37869596
DOI: 10.1007/s40201-023-00872-z -
Digestive Diseases and Sciences Dec 2023The rate of adequate cleansing (ACR) and complete examinations (CR) are key quality indicators in capsule colonoscopy (CC) and pan-intestinal capsule endoscopy (PCE). (Meta-Analysis)
Meta-Analysis
BACKGROUND
The rate of adequate cleansing (ACR) and complete examinations (CR) are key quality indicators in capsule colonoscopy (CC) and pan-intestinal capsule endoscopy (PCE).
AIMS
To evaluate the efficacy of bowel preparation protocols regarding ACR and CR.
METHODS
We conducted a systematic review and meta-analysis, search terms regarding colon capsule preparation, publication date from 2006/01, and date of search 2021/12, in six bibliographic databases. Multiple steps of the cleansing protocol were assessed: diet, adjunctive laxatives, purgative solution, use of prokinetic agents, and "booster". The meta-analytical frequency of ACR and CR was estimated, and subgroup analyses performed. Strategies associated with higher ACR and CR were explored using meta-analytical univariable and multivariable regression models.
RESULTS
Twenty-six observational studies and five RCTs included (n = 4072 patients). The pooled rate of ACR was 72.5% (95% C.I. 67.8-77.5%; I = 92.4%), and the pooled rate of CR was 83.0% (95% C.I. 78.7-87.7%; I = 96.5%). The highest ACR were obtained using a low-fibre diet [78.5% (95% C.I. 72.0-85.6%); I = 57.0%], adjunctive laxatives [74.7% (95% C.I. 69.8-80.1%); I = 85.3%], and split dose < 4L polyethylene glycol (PEG) as purgative [77.5% (95% C.I. 68.4-87.8%); I = 47.3%]. The highest CR were observed using routine prokinetics prior to capsule ingestion [84.4% (95% C.I. 79.9-89.2%); I = 89.8%], and sodium phosphate (NaP) as "booster" [86.2% (95% C.I. 82.3-90.2%); I = 86.8%]. In univariable models, adjunctive laxatives were associated with higher ACR [OR 1.81 (95% C.I. 1.13; 2.90); p = 0.014]. CR was higher with routine prokinetics [OR 1.86 (95% C.I. 1.13; 3.05); p = 0.015] and split-dose PEG purgative [OR 2.03 (95% C.I. 1.01; 4.09), p = 0.048].
CONCLUSIONS
Main quality outcomes (ACR, CR) remain suboptimal for CC and PCE. Despite considerable heterogeneity, our results support low-fibre diet, use of adjunctive sennosides, split dose < 4L PEG, and routine prokinetics, while NaP remains the most consistent option as booster.
Topics: Humans; Cathartics; Laxatives; Capsule Endoscopy; Colonoscopy; Polyethylene Glycols
PubMed: 37833441
DOI: 10.1007/s10620-023-08133-7 -
Alternative Therapies in Health and... Nov 2023An intertrochanteric fracture can cause ischemic necrosis in the femoral head, leading to negative effects. There are many types of implants for this fracture procedure,... (Meta-Analysis)
Meta-Analysis
BACKGROUND
An intertrochanteric fracture can cause ischemic necrosis in the femoral head, leading to negative effects. There are many types of implants for this fracture procedure, including metal-on-metal, metal-on-polyethylene, ceramic-on-ceramic, and ceramic-on-polyethylene, that are currently in use. The current modification is a hybrid prosthetic implant with high functional capacity compared with predecessors. This study aims to determine the procedure's efficacy in recovery, function restoration, complications, and cost-effectiveness.
METHODS
Our study used a total of 200 patients undergoing total hip arthroplasty and 135 patients undergoing semi-hip arthroplasty to determine the effectiveness of total hip arthroplasty and femoral head arthroplasty From May 2022 to May 2023. Using the RAOSOFT sampling technique, 132 and 101 in the observation and control group, respectively, the sample is obtained with a confidence interval of 95%, an error margin of 1%, and response interval confidence of 50%. This is a descriptive type of research that relies on a meta-analysis of the available data from PubMed, scholarly articles, and the Chinese biomedical database to gather the fundamental data needed to conduct the research. Data obtained is analyzed using SSPS and STATA and presented in tables showing a summary of the objective measured value.
RESULT
In this study, the Harris joint score of patients in the total hip arthroplasty group was significantly higher than that of the control group, indicating that total hip arthroplasty can restore femoral head function, but still lacks absolute strength like half hip arthroplasty.
CONCLUSIONS
Femoral head replacement is a complex procedure, but the efficacy in restoring the function is better. In conclusion, despite slow healing and regeneration, the efficacy of complete artificial femoral head replacement is higher in restoring function for various fractures.
Topics: Humans; Hip Prosthesis; Femur Head; Arthroplasty, Replacement, Hip; Hip Fractures; Polyethylene; Treatment Outcome; Retrospective Studies
PubMed: 37820651
DOI: No ID Found -
Sensors (Basel, Switzerland) Sep 2023This research presents a dual-pronged bibliometric and systematic review of the integration of phase change materials (PCM) in asphalt pavements to counteract the urban... (Review)
Review
This research presents a dual-pronged bibliometric and systematic review of the integration of phase change materials (PCM) in asphalt pavements to counteract the urban heat island (UHI) effect. The bibliometric approach discerns the evolution of PCM-inclusion asphalt research, highlighting a marked rise in the number of publications between 2019 and 2022. Notably, Chang'an University in China has emerged as a leading contributor. The systematic review addresses key questions like optimal PCM types for UHI effect mitigation, strategies for PCM leakage prevention in asphalt, and effects on mechanical properties. The findings identify polyethylene glycols (PEGs), especially PEG2000 and PEG4000, as prevailing PCM due to their wide phase-change temperature range and significant enthalpy during phase transitions. While including PCM can modify asphalt's mechanical attributes, such mixtures typically stay within performance norms. This review emphasises the potential of PCM in urban heat management and the need for further research to achieve optimal thermal and mechanical balance.
PubMed: 37765798
DOI: 10.3390/s23187741 -
Polymers Sep 2023Composite resin is universally used for posterior teeth restorations. Fibers have been suggested for the mechanical improvement of the restorations. This study assessed... (Review)
Review
Composite resin is universally used for posterior teeth restorations. Fibers have been suggested for the mechanical improvement of the restorations. This study assessed the fracture resistance of class II fiber-reinforced composite restorations and compared it with the fracture resistance of three control groups: (1) healthy teeth, (2) non-fiber-reinforced restorations and (3) unrestored cavities. A search was performed using PubMed, Web of Science and Google Scholar from 15 May to 12 June 2023. Only in vitro studies from the last 10 years were included for this systematic analysis. This study was registered in the PROSPERO database, it followed PRISMA guidelines and the risk of bias was assessed using the QUIN tool. Fracture resistance median values, in Newtons (N), were calculated for the experimental and control groups (95% confidence interval). For pairwise comparison, nonparametric tests ( < 0.05) were applied. Twenty-four in vitro studies met the inclusion criteria. The fracture resistance of the experimental group was 976.0 N and differed ( < 0.05) from all controls. The experimental group showed lower values of fracture resistance than healthy teeth (1459.9 N; = 0.048) but higher values than non-fiber-reinforced restorations (771.0 N; = 0.008) and unrestored cavities (386.6 N; < 0.001). In vitro systematic outcomes evidenced that glass and/or polyethylene fibers improved the fracture resistance of composite restorations.
PubMed: 37765654
DOI: 10.3390/polym15183802 -
Scientific Reports Sep 2023Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing...
Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing polyethylene and ceramics has led to improved wear parameters and contributed to improved long-term outcomes. The present systematic review investigated whether time span from implantation, patient characteristics and performance status exert an influence on liner wear and head migration in THA. This study was conducted in conformity to the 2020 PRISMA guidelines. All the clinical investigations which reported quantitative data on the amount of liner wear and head migration in THA were considered. Only studies which reported quantitative data at least on one of the following patient characteristics were suitable: mean age, mean BMI (kg/m), sex, side, time span between the index THA and the last follow-up (months) were eligible. A multiple linear model regression analysis was employed to verify the association between patient characteristics and the amount of liner wear and/or head migration. The Pearson Product-Moment Correlation Coefficient was used to assess the association between variables. Data from 12,629 patients were considered. The mean length of the follow-up was 90.5 ± 50.9 months. The mean age of patients at surgery was 58.4 ± 9.4 years, and the mean BMI was 27.2 ± 2.5 kg/m. 57% (7199 of 12,629 patients) were women, and in 44% (5557 of 12,629 patients) THAs were performed on the left. The mean pre-operative Harris hip score was 46.5 ± 6.0 points. There was evidence of a moderate positive association between the amount of liner wear and the time elapsed between the index surgery to the follow-up (P = 0.02). There was evidence of a moderate positive association between the amount of head migration and the time elapsed between the index surgery to the follow-up (P = 0.01). No further statistically significant association was found. The time elapsed between the index surgery to the follow-up was the most important factor which influence the head migration and liner wear in THA. Patients' characteristics and preoperative physical activity did not influence the amount of head migration and liner wear.
Topics: Humans; Female; Middle Aged; Aged; Male; Arthroplasty, Replacement, Hip; Risk Factors; Ceramics; Correlation of Data; Polyethylene
PubMed: 37730762
DOI: 10.1038/s41598-023-42809-4 -
Journal of Gastrointestinal Oncology Aug 2023Although both high- and low-volume polyethylene glycol (PEG) are widely used in intestinal preparation before colonoscopy, there is still controversy over the...
The safety and effects of high- and low-volume polyethylene glycol bowel preparation methods before colonoscopy on bowel cleanliness: a systematic review and meta-analysis.
BACKGROUND
Although both high- and low-volume polyethylene glycol (PEG) are widely used in intestinal preparation before colonoscopy, there is still controversy over the superiority of their cleaning effects. This meta-analysis sought to explore the safety and effects of high-volume PEG solution and low-volume PEG mixed solution on intestinal cleanliness before colonoscopy.
METHODS
The PubMed, EMBASE, and Cochrane Library databases were searched to retrieve relevant articles on the effects of high- and low-volume PEG mixture solutions on intestinal cleanliness from the inception of the databases to October 15, 2022. Two independent researchers screened the literature according to the predetermined inclusion and exclusion criteria, and extracted the required data separately. A bias risk assessment was conducted for each study using the relevant tools in the Cochrane Handbook. The included data were subjected to a meta-analysis using R 4.2.1 software.
RESULTS
This article includes a total of 15 studies involving a total of 5,847 patients. There was no difference in the cleanliness score, qualified rate of intestinal cleanliness and patient compliance between the high- and low-volume group. The patients in the low-volume PEG mixed solution group had a higher repeat willingness bowel cleansing rate than those in the high-volume PEG group [risk ratio (RR) =0.71, 95% confidence interval (CI): 0.62-0.82, P<0.01]. Compared with the low-volume group, the incidence of adverse reactions such as nausea, vomiting, and abdominal pain increased in the high-volume group (RR =1.38, 95% CI: 1.22-1.56, P<0.01; RR =1.79, 95% CI: 1.41-2.27, P<0.01; RR =1.05, 95% CI: 1.01-1.08, P<0.01).
CONCLUSIONS
In the pre-colonoscopy preparation method for patients, although the high-volume PEG and low-volume PEG mixed regimen have similar effects on intestinal cleanliness, the low-volume mixed regimen has a higher willingness to repeat and a lower incidence of adverse reactions. In clinical practice, considering patient compliance and safety, a low-volume mixed regimen may be a more optimal option.
PubMed: 37720457
DOI: 10.21037/jgo-23-581 -
Frontiers in Endocrinology 2023This study aimed to perform a network meta-analysis to objectively evaluate the efficacy and safety of 10 Glucagon-like peptide-1 receptor agonists (GLP-1RAs) in... (Comparative Study)
Comparative Study Meta-Analysis Review
PURPOSE
This study aimed to perform a network meta-analysis to objectively evaluate the efficacy and safety of 10 Glucagon-like peptide-1 receptor agonists (GLP-1RAs) in combination with metformin that is approved for use worldwide in patients with type 2 diabetes and to provide evidence-based support and reference for the selection of clinical treatment.
METHODS
Three databases (PubMed, Embase, and Cochrane Library) were searched from their respective inception until September 30, 2022. Only randomized controlled trials comparing the efficacy and safety of GLP-1RAs for treating type 2 diabetes (T2D) were included. The 10 GLP-1RAs are exenatide (including exenatide twice daily and once weekly), liraglutide, lixisenatide, dulaglutide, PEX168, semaglutide (subcutaneous and oral semaglutide), tirzepatide and albiglutide.
RESULTS
34 RCTs with 10 GLP-1RAs and 12993 patients were included in the Network Meta-Analysis (NMA). According to the NMA, tirzepatide 15 mg, semaglutide 1.0 mg, PEX168-200μg, oral semaglutide 14 and dulaglutide 1.5 mg reduced HbA1c by -2.23%, -1.57%, -1.12%, -1.10%, -1.09% and body weight by -11.33 kg, -5.99 kg, +0.40 kg, -3.95 kg, -1.87 kg, respectively. There was no significant difference in the rate of adverse events for tirzepatide 15 mg, oral-semaglutide 14 mg, and semaglutide 1.0 mg. PEX168-200μg, tirzepatide 15mg, and oral semaglutide 14mg had Surface Under the Cumulative Ranking (SUCRA) values greater than placebo, and only tirzepatide 15mg and oral semaglutide 14mg were significantly different from placebo in the rate of serious adverse events. All GLP-1RA did not lead to increased incidence of hypoglycemia. Albiglutide 30mg and semaglutide 1.0mg significantly differed from placebo in Adverse Event (AE) withdrawal. Finally, the sensitivity analysis and publication bias analysis results indicate that the study results are reliable.
CONCLUSION
This study's results showed that GLP-1RAs were effective in lowering HbA1c and reducing body weight without increased incidence of hypoglycemic reactions. In addition, this study may provide reference and evidence-based medical evidence for clinicians to select GLP-1RAs in patients with T2D and high body mass index (BMI). Based on the NMA results, tirzepatide 15mg and semaglutide 1.0mg may be preferred.
Topics: Humans; Body Weight; Diabetes Mellitus, Type 2; Exenatide; Glucagon-Like Peptide-1 Receptor; Glycated Hemoglobin; Metformin
PubMed: 37701904
DOI: 10.3389/fendo.2023.1244432 -
Journal of Orthopaedic Surgery and... Aug 2023The positioning of implant components for total hip arthroplasty (THA) is essential for joint stability, polyethylene liner wear, and range of motion. One potential... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The positioning of implant components for total hip arthroplasty (THA) is essential for joint stability, polyethylene liner wear, and range of motion. One potential benefit of the direct anterior approach (DAA) for THA is the ability to use intraoperative fluoroscopy for acetabular cup positioning and limb-length evaluation. Previous studies comparing intraoperative fluoroscopy with no fluoroscopy during DAA have reported conflicting results. This meta-analysis aimed to evaluate whether intraoperative fluoroscopy improves component positioning compared to no fluoroscopy during direct anterior total hip arthroplasty.
METHODS
A systematic review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was conducted. We searched Web of Science, EMBASE, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database in May 2023 to identify studies involving intraoperative fluoroscopy versus no fluoroscopy during direct anterior total hip arthroplasty. Finally, we identified 1262 hips assessed in seven studies.
RESULTS
There were no significant differences in terms of acetabular cup inclination angle (ACIA, P = 0.21), ACIA within safe zone rate (P = 0.97), acetabular cup anteversion angle (ACAA, P = 0.26); ACAA within safe zone rate (P = 0.07), combined safe zone rate (P = 0.33), and limb-length discrepancy (LLD, P = 0.21) between two groups.
CONCLUSION
Even though intraoperative fluoroscopy was not related to an improvement in cup location or LDD. With fewer experienced surgeons, the benefit of intraoperative fluoroscopy might become more evident. More adequately powered and well-designed long-term follow-up studies were required to determine whether the application of the intraoperative fluoroscopy for direct anterior total hip arthroplasty will have clinical benefits and improve the survival of prostheses.
Topics: Arthroplasty, Replacement, Hip; Hip Joint; Hip Prosthesis; Retrospective Studies; Acetabulum
PubMed: 37553600
DOI: 10.1186/s13018-023-04023-w