Neuropathology and Applied Neurobiology Feb 2023Muscle biopsy techniques range from needle muscle biopsy (NMB) and conchotome biopsy to open surgical biopsy. It is unknown whether specific biopsy techniques offer...
AIMS
Muscle biopsy techniques range from needle muscle biopsy (NMB) and conchotome biopsy to open surgical biopsy. It is unknown whether specific biopsy techniques offer superior diagnostic yield or differ in procedural complication rates. Therefore, we aimed to compare the diagnostic utility of NMB, conchotome and open muscle biopsies in the assessment of neuromuscular disorders.
METHODS
A systematic literature review of the EMBASE and Medline (Ovid) databases was performed to identify original, full-length research articles that described the muscle biopsy technique used to diagnose neuromuscular disease in both adult and paediatric patient populations. Studies of any design, excluding case reports, were eligible for inclusion. Data pertaining to biopsy technique, biopsy yield and procedural complications were extracted.
RESULTS
Sixty-four studies reporting the yield of a specific muscle biopsy technique and, or procedural complications were identified. Open surgical biopsies provided a larger tissue sample than any type of percutaneous muscle biopsy. Where anaesthetic details were reported, general anaesthesia was required in 60% of studies that reported open surgical biopsies. Percutaneous biopsies were most commonly performed under local anaesthesia and despite the smaller tissue yield, moderate- to large-gauge needle and conchotome muscle biopsies had an equivalent diagnostic utility to that of open surgical muscle biopsy. All types of muscle biopsy procedures were well tolerated with few adverse events and no scarring complications were reported with percutaneous sampling.
CONCLUSIONS
When a histological diagnosis of myopathy is required, moderate- to large-gauge NMB and the conchotome technique appear to have an equivalent diagnostic yield to that of an open surgical biopsy.
Topics: Adult; Child; Humans; Biopsy; Neuromuscular Diseases; Biopsy, Needle; Muscular Diseases; Muscles; Retrospective Studies
PubMed: 36734037
DOI: 10.1111/nan.12888 -
Diagnostics (Basel, Switzerland) Nov 2022One of the most effective diagnostic tools for pancreatic cancer is endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) or biopsy (EUS-FNB). Several randomized... (Review)
Review
Endoscopic Ultrasound Guided Fine Needle Aspiration versus Endoscopic Ultrasound Guided Fine Needle Biopsy for Pancreatic Cancer Diagnosis: A Systematic Review and Meta-Analysis.
INTRODUCTION
One of the most effective diagnostic tools for pancreatic cancer is endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) or biopsy (EUS-FNB). Several randomized clinical trials have compared different EUS tissue sampling needles for the diagnosis of pancreatic cancer.
OBJECTIVE
To compare the diagnostic accuracy of EUS-guided FNA as EUS-FNB needles for the diagnosis of pancreatic cancer using a systematic review and meta-analysis.
METHOD
A literature review with a meta-analysis was performed according to the PRISMA guide. The databases of PubMed, Cochrane and Google Scholar were used, including studies published between 2011-2021 comparing the diagnostic yield (diagnostic accuracy or probability of positivity, sensitivity, specificity, predictive value) of EUS-FNA and EUS-FNB for the diagnosis of pancreatic cancer. The primary outcome was diagnostic accuracy. Random effect models allowed estimation of the pooled odds ratio with a confidence interval (CI) of 95%.
RESULTS
Nine randomized control trials were selected out of 5802 articles identified. Among these, five studies found no statistically significant difference between the EUS-FNA and EUS-FNB, whereas the other four did. The meta-analysis found EUS-FNB accuracy superior to EUS-FNA for the diagnosis of pancreatic cancer with a pooled odds ratio of 1.87 (IC 95%: 1.33-2.63).
CONCLUSION
As compared to EUS-FNA, EUS-FNB seems to improve diagnostic accuracy when applied to suspicious pancreatic lesions.
PubMed: 36552957
DOI: 10.3390/diagnostics12122951 -
Endoscopic Ultrasound 2022The benefit of rapid on-site evaluation (ROSE) on the diagnostic accuracy of EUS-guided fine-needle biopsy (EUS-FNB) in patients with pancreatic masses is still matter... (Review)
Review
Comparison between EUS-guided fine-needle biopsy with or without rapid on-site evaluation for tissue sampling of solid pancreatic lesions: A systematic review and meta-analysis.
The benefit of rapid on-site evaluation (ROSE) on the diagnostic accuracy of EUS-guided fine-needle biopsy (EUS-FNB) in patients with pancreatic masses is still matter of debate. Aim of our meta-analysis is to compare the diagnostic outcomes of these two tissue acquisition strategies. Computerized bibliographic search on the main databases was performed through December 2021 and 8 studies were identified (2147 patients). The primary outcome was sample adequacy. Pooled effects were calculated using a random-effects model by means of DerSimonian and Laird test and summary estimates were expressed in terms of odds ratio (OR) or mean difference and 95% confidence Interval (CI). There was no difference in terms of baseline variables between the two groups. Pooled sample adequacy was 95.5% (95% CI 93.2%-97.8%) and 88.9% (83.4%-94.5%) in the EUS-FNB + ROSE and EUS-FNB groups, respectively (OR = 2.05, 0.94-4.49; P = 0.07). Diagnostic accuracy resulted significantly superior in the EUS-FNB + ROSE group (OR = 2.49, 1.08-5.73; P = 0.03), particularly when the analysis was restricted to reverse bevel needle (OR = 3.24, 1.19-8.82, P = 0.02), whereas no statistical difference was observed when newer end-cutting needles were used (OR = 0.71, 0.29-3.61, P = 0.56). Diagnostic sensitivity was not significantly different between the two groups (OR = 1.94, 0.84-4.49; P = 0.12), whereas pooled specificity was 100% with both approaches. The number of needle passes needed to obtain diagnostic samples was not significantly different (mean difference 0.07,-0.22 to 0.37; P = 0.62). Our meta-analysis stands for a non-superiority of EUS-FNB + ROSE over EUS-FNB with newer end-cutting needles, whereas ROSE could have still a role when reverse bevel needles are used.
PubMed: 36537383
DOI: 10.4103/EUS-D-22-00026 -
Cancers Dec 2022(1) Background: To determine the optimal cut-off values of two risk stratification systems to discriminate malignant thyroid nodules and to compare the diagnostic... (Review)
Review
(1) Background: To determine the optimal cut-off values of two risk stratification systems to discriminate malignant thyroid nodules and to compare the diagnostic performance; (2) Methods: True and false positive and negative data were collected, and methodological quality was assessed for forty-six studies involving 39,085 patients; (3) Results: The highest area under the receiver operating characteristic (ROC) curve (AUC) of ACR and Kwak TI-RADS were 0.875 and 0.884. Based on the optimal sensitivity and specificity, the highest accuracy values of ROC curves or diagnostic odds ratios (DOR) were taken as the cut-off values for TR4 (moderate suspicious) and 4B. The sensitivity, specificity, DOR, and AUC by ACR (TR4) and Kwak TI-RADS (4B) for malignancy risk stratification of thyroid nodules were 94.3% and 96.4%; 52.2% and 53.7%; 17.5185 and 31.8051; 0.786 and 0.884, respectively. There were no significant differences in diagnostic accuracy in any of the direction comparisons of the two systems; (4) Conclusions: ACR and Kwak TI-RADS had good diagnostic performances (AUCs > 85%). Although we determined the best cut-off values in individual risk stratification systems based on statistical assessment, clinicians can adjust the optimal cut-off value according to the clinical purpose of the ultrasonography because raising or lowering cut-points leads to reciprocal changes in sensitivity and specificity.
PubMed: 36497443
DOI: 10.3390/cancers14235961 -
Pathogens (Basel, Switzerland) Nov 2022Schistosomiasis is an endemic parasitic infection found in many tropical countries and is highly prevalent in sub-Saharan Africa. It can follow different and atypical... (Review)
Review
BACKGROUND
Schistosomiasis is an endemic parasitic infection found in many tropical countries and is highly prevalent in sub-Saharan Africa. It can follow different and atypical clinical patterns. In these unusual cases, diagnosis may be difficult, as symptoms are unspecific. Arthropathy can appear in parasitic infections, but making a connection between arthritis and parasitic aetiology is difficult. This review aims to summarise all cases that have reported schistosomiasis associated with arthropathy, and the different ways authors have diagnosed this disease.
METHOD
We present a systematic literature review of schistosomiasis associated with joint impairments, with a focus on the difficulty of differentiating between reactive arthritis and its parasitic presence in situ.
RESULTS
Joint impairments mimicking polyarthropathy are not rare in parasitic infections. Diagnosis is difficult. On the one hand, some patients have arthritis with parasite eggs found in situ, particularly in synovial biopsy. These situations are less common and antiparasitic treatment is straightforward. On the other hand, arthritis can be associated with parasitic infections in the form of reactive arthritis due to an immunological reaction. In such cases, pathogenicity due to circulating immune complex should be suspected. Anti-inflammatory treatments such as corticosteroids or immunosuppressive therapies are ineffective in cases of schistosomal arthropathy. A joint fluid puncture appears to be necessary and parasitic examination as well as in situ immunological techniques appear to be important in order to confirm the diagnosis of schistosomal arthropathy.
CONCLUSIONS
The frequency of articular schistosomiasis is probably underestimated and should be sought when patients have unexplained polyarthropathy, as it can be an alternative diagnosis when patients have concomitant parasitic infections. These situations are common, whereas the association between unexplained inflammatory arthritis and a concomitant parasitic infection is rarely made. Unspecific rheumatism can lead to probabilistic treatments with many side effects, and looking for a parasitic aetiology could lead to repeated antiparasitic treatments and may avoid other immunosuppressive or corticosteroid therapies. With increasing travel and global migration, physicians need to be more aware of nonspecific symptoms that may reveal an atypical presentation of a tropical disease that can be treated easily, thus avoiding inappropriate immunosuppressive treatments.
PubMed: 36422620
DOI: 10.3390/pathogens11111369 -
Acta Cytologica 2023The primary objective is to determine the accuracy of fine-needle aspiration biopsy (FNAB) in breast lesions reported according to the International Academy of Cytology... (Meta-Analysis)
Meta-Analysis
Systematic Review and Meta-Analysis of the Diagnostic Accuracy of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Biopsy in Diagnosing Breast Cancer.
OBJECTIVES
The primary objective is to determine the accuracy of fine-needle aspiration biopsy (FNAB) in breast lesions reported according to the International Academy of Cytology (IAC) Yokohama system for reporting breast FNAB. The participants include any patient presenting with any breast lesion found suitable for FNAB. The target condition was breast cancer. The secondary objective was to study the proportion of inadequate FNAB in the selected studies.
METHODS
PubMed/MEDLINE and Embase were searched for studies having all the following key search terms: Breast AND FNAB AND Diagnostic Accuracy published in the time frame of 2017 to May 16, 2022. The Cochrane and PROSPERO databases, citations of selected articles and articles citing the selected articles were also searched. Studies assessing the diagnostic accuracy of breast FNAB in diagnosing breast cancer, which had at least 75 subjects (and at least 20 subjects each in the benign and malignant FNAB groups), were selected. The reference standard was histopathology (or adequate clinical follow-up for benign disease). Studies were screened independently by two researchers, with a consensus reached among the authors in cases of conflict. The risk of bias and applicability were assessed using the QUADAS-2 tool. Sensitivity and specificity at each diagnostic cut-off were assessed by bivariate generalized linear mixed-model meta-analysis. The area under the receiver operating characteristics curve (AUC) and inadequacy rate were assessed by random-effects meta-analysis. The confidence intervals of sensitivity, specificity, and AUC were examined against a value of 0.95.
RESULTS
Twenty-two studies, all of which were cross-sectional single-gate studies, were selected with a total of 10,886 subjects with a primary breast lesion having concurrent FNAB and reference standard reports. Sensitivity and specificity, with 95% confidence intervals, were 0.978 [0.968, 0.985] and 0.832 [0.76, 0.886] for the diagnostic cut-off of "Atypical considered positive for malignancy," 0.916 [0.892, 0.935] and 0.983 [0.97, 0.99] for the cut-off of "Suspicious of Malignancy considered positive," and 0.763 [0.706, 0.812] and 0.999 [0.994, 1] for the cut-off of "Malignant considered positive." The overall AUC was 0.975 [0.962, 0.984]. FNAB sampling without imaging guidance was associated with lower inadequacy.
DISCUSSION
There is strong evidence that the overall accuracy, sensitivity for "Atypical category considered positive" and specificity when "Suspicious or Malignant categories are considered positive" of FNAB are high when using the categories of the IAC Yokohama Reporting System, demonstrating the usefulness of FNAB in diagnosing breast cancer.
Topics: Humans; Female; Breast Neoplasms; Biopsy, Fine-Needle; Breast; Cytodiagnosis; Cytological Techniques; Sensitivity and Specificity
PubMed: 36412573
DOI: 10.1159/000527346 -
Gastroenterology Report 2022Endoscopic ultrasound (EUS)-guided tissue acquisition represents the choice of methods for suspected lymph nodes (LNs) located next to the gastrointestinal tract. This...
BACKGROUND
Endoscopic ultrasound (EUS)-guided tissue acquisition represents the choice of methods for suspected lymph nodes (LNs) located next to the gastrointestinal tract. This study aimed to compare the pooled diagnostic performance of EUS-guided fine-needle biopsy (EUS-FNB) and fine-needle aspiration (EUS-FNA) for LNs sampling.
METHODS
We searched PubMed/MedLine and Embase databases through August 2021. Primary outcome was diagnostic accuracy; secondary outcomes were sensitivity, specificity, sample adequacy, optimal histological core procurement, number of passes, and adverse events. We performed a pairwise meta-analysis using a random-effects model. The results are presented as odds ratio (OR) or mean difference along with 95% confidence interval (CI).
RESULTS
We identified nine studies (1,276 patients) in this meta-analysis. Among these patients, 66.4% were male; the median age was 67 years. Diagnostic accuracy was not significantly different between the two approaches (OR, 1.31; 95% CI, 0.81-2.10; =0.270). The accuracy of EUS-FNB was significantly higher when being performed with newer end-cutting needles (OR, 1.87; 95% CI, 1.17-3.00; =0.009) and in abdominal LNs (OR, 2.48; 95% CI, 1.52-4.05; <0.001) than that of EUS-FNA. No difference in terms of sample adequacy was observed between the two approaches (OR, 1.40; 95% CI, 0.46-4.26; =0.550); however, histological core procurement and diagnostic sensitivity with EUS-FNB were significantly higher than those with EUS-FNA (OR, 6.15; 95% CI, 1.51-25.07; =0.010 and OR, 1.87; 95% CI, 1.27-2.74, =0.001). The number of needle passes needed was significantly lower in the EUS-FNB group than in the EUS-FNA group (mean difference, -0.54; 95% CI, -0.97 to -0.12; =0.010).
CONCLUSIONS
EUS-FNA and EUS-FNB perform similarly in LN sampling; however, FNB performed with end-cutting needles outperformed FNA in terms of diagnostic accuracy.
PubMed: 36340808
DOI: 10.1093/gastro/goac062 -
Journal of Clinical Medicine Oct 2022Background: To assess the diagnostic utility of middle meatal culture (MMC) in patients with acute and chronic sinusitis; Methods: Six databases were thoroughly reviewed... (Review)
Review
Background: To assess the diagnostic utility of middle meatal culture (MMC) in patients with acute and chronic sinusitis; Methods: Six databases were thoroughly reviewed up to March 2022. Sensitivity, specificity, and negative and positive predictive values were extracted. Methodological quality was evaluated using the QUADAS-2 instrument; Results: Fifteen reports were analyzed. MMC results exhibited a significant correlation (r = 0.7590, 95% confidence interval [CI] [0.6855; 0.8172], p < 0.0001) with those of maxillary sinus puncture. The diagnostic odds ratio (DOR) of MMC (reference = maxillary sinus culture) was 8.5475 [3.9238; 18.6199]. The area under the summary receiver operating characteristic curve was 0.761. The sensitivity and specificity of MMC were 0.7759 [0.6744; 0.8526] and 0.7514 [0.6110; 0.8534], respectively. We performed subgroup analysis based on age (children vs. adults), duration of disease (acute vs. chronic), and specimen collection method (biopsy, swabs, suction tips). The DORs, specificities, and negative and positive predictive values varied significantly. Diagnostic accuracy was highest for children and individuals with chronic disease, and when samples were collected via suction.; Conclusions: MMC provided fair diagnostic accuracy in patients with acute or chronic sinusitis. Although some institutional differences were evident, the middle meatal and maxillary sinus culture results were similar.
PubMed: 36294389
DOI: 10.3390/jcm11206069 -
PloS One 2022At present, it is difficult and risky to diagnose splenic lesions by conventional needle biopsy using computed tomography (CT) or ultrasound (US). Endoscopic ultrasound... (Meta-Analysis)
Meta-Analysis
BACKGROUND AND AIMS
At present, it is difficult and risky to diagnose splenic lesions by conventional needle biopsy using computed tomography (CT) or ultrasound (US). Endoscopic ultrasound (EUS)-guided tissue acquisition is increasingly being used as a new technique to determine the tissue diagnosis of splenic lesions. Therefore, our goal was to determine the efficacy and safety of EUS-guided tissue acquisition for splenic lesions.
METHODS
We performed a systematic review and meta-analysis to evaluate the pooled sensitivity and specificity of EUS-guided tissue acquisition for the diagnosis of splenic lesions using Metadisc. The Quality Assessment of Diagnostic Accuracy Studies Questionnaire, a quality assessment tool, was used to scrutinize the quality of the studies.
RESULTS
Six eligible studies between January 2000 and June 2022 were identified, and a total number of 62 patients (aged range from 19 to 84) were enrolled. One patient was excluded because of insufficient specimens. The pooled sensitivity and specificity of included studies were 0.85 [95% confidence interval (CI), 0.73-0.93] and 0.77 (95% CI, 0.46-0.95), respectively. The pooled positive likelihood ratio (LR) was 2.38 (95% CI, 1.24-4.57), the pooled negative LR was 0.31 (95% CI, 0.17-0.55), the pooled diagnostic odds ratio (DOR) was 8.67 (95% CI, 2.80-26.82), the area under the summary receiver operating characteristic (SROC) curve was 0.8100 (Standard Error 0.0813).
CONCLUSION
EUS-guided tissue acquisition is a safe technique with high sensitivity in the diagnosis of splenic lesions. However, because of the small sample sizes, more studies with more cases are needed to further validate these results.
Topics: Humans; Endoscopic Ultrasound-Guided Fine Needle Aspiration; Pancreatic Neoplasms; Diagnostic Tests, Routine; Endosonography; Sensitivity and Specificity; Splenic Diseases
PubMed: 36264978
DOI: 10.1371/journal.pone.0276529 -
JAMA Surgery Dec 2022Fine-needle biopsy (FNB) became a critical part of thyroid nodule evaluation in the 1970s. It is not clear how diagnostic accuracy of FNB has changed over time. (Meta-Analysis)
Meta-Analysis
IMPORTANCE
Fine-needle biopsy (FNB) became a critical part of thyroid nodule evaluation in the 1970s. It is not clear how diagnostic accuracy of FNB has changed over time.
OBJECTIVE
To conduct a systematic review and meta-analysis estimating the accuracy of thyroid FNB for diagnosis of malignancy in adults with a newly diagnosed thyroid nodule and to characterize changes in accuracy over time.
DATA SOURCES
PubMed, SCOPUS, and Cochrane Central Register of Controlled Trials were searched from 1975 to 2020 using search terms related to FNB accuracy in the thyroid.
STUDY SELECTION
English-language reports of cohort studies or randomized trials of adult patients undergoing thyroid FNB with sample size of 20 or greater and using a reference standard of surgical histopathology or clinical follow-up were included. Articles that examined only patients with known thyroid disease or focused on accuracy of novel adjuncts, such as molecular tests, were excluded. Two investigators screened each article and resolved conflicts by consensus. A total of 36 of 1023 studies met selection criteria.
DATA EXTRACTION AND SYNTHESIS
The MOOSE guidelines were used for data abstraction and assessing data quality and validity. Two investigators abstracted data using a standard form. Studies were grouped into epochs by median data collection year (1975 to 1990, 1990 to 2000, 2000 to 2010, and 2010 to 2020). Data were pooled using a bivariate mixed-effects model.
MAIN OUTCOMES AND MEASURES
The primary outcome was accuracy of FNB for diagnosis of malignancy. Accuracy was hypothesized to increase in later time periods, a hypothesis formulated prior to data collection.
RESULTS
Of 16 597 included patients, 12 974 (79.2%) were female, and the mean (SD) age was 47.3 (12.9) years. The sensitivity of FNB was 85.6% (95% CI, 79.9-89.5), the specificity was 71.4% (95% CI, 61.1-79.8), the positive likelihood ratio was 3.0 (95% CI, 2.3-4.1), and the negative likelihood ratio was 0.2 (95% CI, 0.2-0.3). The area under the receiver operating characteristic curve was 86.1%. Epoch was not significantly associated with accuracy. None of the available covariates could explain observed heterogeneity.
CONCLUSIONS AND RELEVANCE
Accuracy of thyroid FNB has not significantly changed over time. Important developments in technique, preparation, and interpretation may have occurred too heterogeneously to capture a consistent uptrend over time. FNB remains a reliable test for thyroid cancer diagnosis.
Topics: Female; Male; Humans; Thyroid Nodule; Biopsy, Fine-Needle; Thyroid Neoplasms
PubMed: 36223097
DOI: 10.1001/jamasurg.2022.4989