International Journal of Molecular... May 2024This review article focuses on the role of adenosine in coronary artery disease (CAD) diagnosis and treatment. Adenosine, an endogenous purine nucleoside, plays crucial... (Review)
Review
This review article focuses on the role of adenosine in coronary artery disease (CAD) diagnosis and treatment. Adenosine, an endogenous purine nucleoside, plays crucial roles in cardiovascular physiology and pathology. Its release and effects, mediated by specific receptors, influence vasomotor function, blood pressure regulation, heart rate, and platelet activity. Adenosine therapeutic effects include treatment of the no-reflow phenomenon and paroxysmal supraventricular tachycardia. The production of adenosine involves complex cellular pathways, with extracellular and intracellular synthesis mechanisms. Adenosine's rapid metabolism underscores its short half-life and physiological turnover. Furthermore, adenosine's involvement in side effects of antiplatelet therapy, particularly ticagrelor and cangrelor, highlights its clinical significance. Moreover, adenosine serves as a valuable tool in CAD diagnosis, aiding stress testing modalities and guiding intracoronary physiological assessments. Its use in assessing epicardial stenosis and microvascular dysfunction is pivotal for treatment decisions. Overall, understanding adenosine's mechanisms and clinical implications is essential for optimizing CAD management strategies, encompassing both therapeutic interventions and diagnostic approaches.
Topics: Humans; Adenosine; Coronary Artery Disease; Animals; Adenosine Monophosphate; Platelet Aggregation Inhibitors
PubMed: 38892037
DOI: 10.3390/ijms25115852 -
Circulation. Cardiovascular Imaging Jun 2024This study aimed to develop and validate a computed tomography angiography based machine learning model that uses plaque composition data and degree of carotid stenosis...
BACKGROUND
This study aimed to develop and validate a computed tomography angiography based machine learning model that uses plaque composition data and degree of carotid stenosis to detect symptomatic carotid plaques in patients with carotid atherosclerosis.
METHODS
The machine learning based model was trained using degree of stenosis and the volumes of 13 computed tomography angiography derived intracarotid plaque subcomponents (eg, lipid, intraplaque hemorrhage, calcium) to identify plaques associated with cerebrovascular events. The model was internally validated through repeated 10-fold cross-validation and tested on a dedicated testing cohort according to discrimination and calibration.
RESULTS
This retrospective, single-center study evaluated computed tomography angiography scans of 268 patients with both symptomatic and asymptomatic carotid atherosclerosis (163 for the derivation set and 106 for the testing set) performed between March 2013 and October 2019. The area-under-receiver-operating characteristics curve by machine learning on the testing cohort (0.89) was significantly higher than the areas under the curve of traditional logit analysis based on the degree of stenosis (0.51, <0.001), presence of intraplaque hemorrhage (0.69, <0.001), and plaque composition (0.78, <0.001), respectively. Comparable performance was obtained on internal validation. The identified plaque components and associated cutoff values that were significantly associated with a higher likelihood of symptomatic status after adjustment were the ratio of intraplaque hemorrhage to lipid volume (≥50%, 38.5 [10.1-205.1]; odds ratio, 95% CI) and percentage of intraplaque hemorrhage volume (≥10%, 18.5 [5.7-69.4]; odds ratio, 95% CI).
CONCLUSIONS
This study presented an interpretable machine learning model that accurately identifies symptomatic carotid plaques using computed tomography angiography derived plaque composition features, aiding clinical decision-making.
Topics: Humans; Computed Tomography Angiography; Male; Machine Learning; Female; Retrospective Studies; Plaque, Atherosclerotic; Aged; Middle Aged; Carotid Artery Diseases; Carotid Stenosis; Predictive Value of Tests; Reproducibility of Results; Carotid Arteries; Severity of Illness Index
PubMed: 38889214
DOI: 10.1161/CIRCIMAGING.123.016274 -
EuroIntervention : Journal of EuroPCR... Jun 2024Coronary access (CA) is a major concern in redo-transcatheter aortic valve implantation (TAVI) for failing supra-annular self-expanding transcatheter aortic valves...
BACKGROUND
Coronary access (CA) is a major concern in redo-transcatheter aortic valve implantation (TAVI) for failing supra-annular self-expanding transcatheter aortic valves (TAVs).
AIMS
This ex vivo study evaluated the benefit of leaflet splitting (LS) on subsequent CA after redo-TAVI in anatomies deemed at high risk of unfeasible CA.
METHODS
Ex vivo, patient-specific models were printed three-dimensionally. Index TAVI was performed using ACURATE neo2 or Evolut PRO (TAV-1) at the standard implant depth and with different degrees of commissural misalignment (CMA). Redo-TAVI was performed using the balloon-expandable SAPIEN 3 Ultra (TAV-2) at different implant depths with commissural alignment. Selective CA was attempted for each configuration before and after LS in a pulsatile flow simulator. The leaflet splay area was assessed on the bench.
RESULTS
In matched comparisons of 128 coronary cannulations across 64 redo-TAVI configurations, the overall feasibility of CA significantly increased after LS (60.9% vs 18.7%; p<0.001). The effect of LS varied according to the sinotubular junction height, TAV-1 design, TAV-1 CMA, and TAV-2 implant depth, given TAV-2 alignment. LS enabled CA for up to CMA 45° with the ACURATE neo2 TAV-1 and up to CMA 30° with the Evolut PRO TAV-1. The combination of LS and a low TAV-2 implant provided the highest feasibility of CA after redo-TAVI. The leaflet splay area ranged from 25.60 mm2 to 37.86 mm2 depending on the TAV-1 platform and TAV-2 implant depth.
CONCLUSIONS
In high-risk anatomies, LS significantly improves CA feasibility after redo-TAVI for degenerated supra-annular self-expanding platforms. Decisions on redo-TAVI feasibility should be carefully individualised, taking into account the expected benefit of LS on CA for each scenario.
Topics: Humans; Transcatheter Aortic Valve Replacement; Aortic Valve; Heart Valve Prosthesis; Prosthesis Design; Printing, Three-Dimensional; Aortic Valve Stenosis; Coronary Vessels; Prosthesis Failure; Reoperation
PubMed: 38887883
DOI: 10.4244/EIJ-D-24-00107 -
Frontiers in Cardiovascular Medicine 2024Microvascular resistance reserve (MRR) is a recently introduced specific index of coronary microcirculation. MRR calculation can utilize parameters deriving from...
BACKGROUND
Microvascular resistance reserve (MRR) is a recently introduced specific index of coronary microcirculation. MRR calculation can utilize parameters deriving from coronary flow reserve (CFR) assessment, provided that intracoronary pressure data are also available. The previously proposed pressure-bounded CFR (CFRpb) defines the possible CFR interval on the basis of resting and hyperemic pressure gradients in the epicardial vessel, however, its correlation to the Doppler wire measurement was reported to be rather poor without the correction for hydrostatic pressure.
PURPOSE
We aimed to determine the pressure-bounded coronary MRR interval with hydrostatic pressure correction according to the previously established equations of CFRpb adapted for the MRR concept. Furthermore, we also aimed to design a prediction model using the actual MRR value within the pressure-bounded interval and validate the results against the gold-standard Doppler wire technique.
METHODS
Hydrostatic pressure between the tip of the catheter and the sensor of the pressure wire was calculated by height difference measurement from a lateral angiographic view. In the derivation cohort the pressure-bounded MRR interval (between MRRpb and MRRpb) was determined solely from hydrostatic pressure-corrected intracoronary pressure data. The actual MRR was calculated by simple hemodynamic equations incorporating the anatomical data of the three-dimensionally reconstructed coronary artery (MRR). These results were analyzed by regression analyses to find relations between the MRRpb bounds and the actual MRR.
RESULTS
In the derivation cohort of 23 measurements, linear regression analysis showed a tight relation between MRRpb and MRR ( = 0.74, < 0.0001). Using this relation (MRR = 1.04 + 0.51 × MRRpb), the linear prediction of the MRR was tested in the validation cohort of 19 measurements against the gold standard Doppler wire technique. A significant correlation was found between the linearly predicted and the measured values ( = 0.54, = 0.01). If the area stenosis (AS%) was included to a quadratic prediction model, the correlation was improved ( = 0.63, = 0.004).
CONCLUSIONS
The MRR can be predicted reliably to assess microvascular function by our simple model. After the correction for hydrostatic pressure error, the pressure data during routine FFR measurement provides a simultaneous physiological assessment of the macro- and microvasculature.
PubMed: 38887446
DOI: 10.3389/fcvm.2024.1322161 -
Clinical Cardiology Jun 2024The coronary artery disease-reporting and data system (CAD-RADS) 2.0 is used to standardize the reporting of coronary computed tomography angiography (CCTA) results....
The Plaque Analysis Classifies the Coronary Artery Disease-Reporting and Data System (CAD-RADS) Stenosis and Plaque Burden Categories: Association of the Plaque Features, Fat Attenuation Index, Coronary Computed Tomography Fractional Flow Reserve, and the Combination of Stenosis and Calcification.
BACKGROUND
The coronary artery disease-reporting and data system (CAD-RADS) 2.0 is used to standardize the reporting of coronary computed tomography angiography (CCTA) results. Artificial intelligence software can quantify the plaque composition, fat attenuation index, and fractional flow reserve.
OBJECTIVE
To analyze plaque features of varying severity in patients with a combination of CAD-RADS stenosis and plaque burden categorization and establish a random forest classification model.
METHODS
The data of 100 patients treated between April 2021 and February 2022 were retrospectively collected. The most severe plaque observed in each patient was the target lesion. Patients were categorized into three groups according to CAD-RADS: CAD-RADS 1-2 + P0-2, CAD-RADS 3-4B + P0-2, and CAD-RADS 3-4B + P3-4. Differences and correlations between variables were assessed between groups. AUC, accuracy, precision, recall, and F1 score were used to evaluate the diagnostic performance.
RESULTS
A total of 100 patients and 178 arteries were included. The differences of computed tomography fractional flow reserve (CT-FFR) (H = 23.921, p < 0.001), the volume of lipid component (H = 12.996, p = 0.002), the volume of fibro-lipid component (H = 8.692, p = 0.013), the proportion of lipid component volume (H = 22.038, p < 0.001), the proportion of fibro-lipid component volume (H = 11.731, p = 0.003), the proportion of calcification component volume (H = 11.049, p = 0.004), and plaque type (χ = 18.110, p = 0.001) was statistically significant.
CONCLUSION
CT-FFR, volume and proportion of lipid and fibro-lipid components of plaques, the proportion of calcified components, and plaque type were valuable for CAD-RADS stenosis + plaque burden classification, especially CT-FFR, volume, and proportion of lipid and fibro-lipid components. The model built using the random forest was better than the clinical model (AUC: 0.874 vs. 0.647).
Topics: Humans; Male; Female; Fractional Flow Reserve, Myocardial; Plaque, Atherosclerotic; Retrospective Studies; Computed Tomography Angiography; Middle Aged; Coronary Angiography; Coronary Stenosis; Severity of Illness Index; Coronary Artery Disease; Coronary Vessels; Vascular Calcification; Aged
PubMed: 38884449
DOI: 10.1002/clc.24305 -
EJVES Vascular Forum 2024Acute limb ischaemia resulting from foreign body embolisation is an infrequent yet critical complication associated with vascular closure devices (VCDs). Despite the...
INTRODUCTION
Acute limb ischaemia resulting from foreign body embolisation is an infrequent yet critical complication associated with vascular closure devices (VCDs). Despite the widespread use of VCDs, rare complications such as fragment emboli pose unique challenges, necessitating heightened clinical awareness. This case report presents a case of acute limb ischaemia caused by a VCD malfunction following an endovascular procedure.
REPORT
A 70 year old male who was diagnosed with a severe claudication of the lower extremity (Rutherford III) due to right common iliac stenosis, underwent angioplasty using a FemoSeal (Terumo Ltd., Surrey, UK) to close the right femoral artery access. Two weeks later, the patient presented with acute lower limb ischaemia due to a right popliteal-tibial occlusion. Emergency surgical thrombo-embolectomy was successfully performed from a medial popliteal approach, and the thrombus, which contained a polymer disc from the VCD at its distal end, was completely removed.
DISCUSSION
Despite VCDs being proven safe and efficient, rare complications such as fragment emboli can occur, and physicians should be aware of the possible delayed onset of symptoms. Moreover, the radiolucent nature of the polymer disc in a FemoSeal complicates diagnostic imaging. While endovascular approaches exist, open surgery is a safe and effective strategy for retrieving fragments and treating the patient in acute limb ischaemia cases.
CONCLUSION
Physicians should remain vigilant for embolic risks associated with vascular closure devices, even with suitable anatomy and following guidelines, especially considering the trend toward early ambulation and discharge.
PubMed: 38884075
DOI: 10.1016/j.ejvsvf.2024.05.006 -
ARYA Atherosclerosis 2023This study aimed to investigate the frequency of asymptomatic intracranial and extracranial artery stenosis in healthy volunteers in Kerman, Iran, in 2019 using Doppler...
INTRODUCTION
This study aimed to investigate the frequency of asymptomatic intracranial and extracranial artery stenosis in healthy volunteers in Kerman, Iran, in 2019 using Doppler ultrasound imaging.
METHOD
This cross-sectional study was conducted on healthy volunteers in Kerman in 2019 following a public elicitation. After the general examination, 138 healthy volunteers who had no history of any disease and were not treated with any medication underwent cerebrovascular evaluation with Doppler ultrasound. Demographic information, history of addiction, and sonographic findings were recorded in a checklist and then analyzed using SPSS 22.
RESULTS
Stenosis was found in 14.4% of volunteers. The mean age of participants was 45.8±10.12 years, and 74 (54%) of them were male. In volunteers with stenosis, a significant correlation was found between age (P = 0.03) and addiction (P = 0.04) with the involved artery. There was also a significant correlation between addiction and intracranial and extracranial artery stenosis (P = 0.04). Logistic regression analysis showed a significant relationship between being female, addiction, and age with stenosis, as well as between addiction and intracranial artery stenosis (P <0.05).
CONCLUSION
The majority of healthy residents of Kerman have asymptomatic cerebrovascular stenosis, and this is more prevalent in the elderly, addicts, and women.
PubMed: 38883853
DOI: 10.48305/arya.2023.11800.2455 -
Journal of Thoracic Disease May 2024Although aortic aneurysm is associated with vascular aging and atherosclerosis, carotid and intracranial vascular disease prevalence in patients with aortic arch...
Prevalence of carotid artery stenosis and intra-cranial lesions in patients with aortic arch aneurysm and its association with intraoperative regional cerebral oxygen saturation and postoperative neurological outcomes.
BACKGROUND
Although aortic aneurysm is associated with vascular aging and atherosclerosis, carotid and intracranial vascular disease prevalence in patients with aortic arch aneurysm remains unclear. Similarly, the effect of carotid and intracranial lesions on postoperative outcomes is unknown. This study aimed to investigate the prevalence of carotid artery stenosis and intracranial lesions in patients with aortic arch aneurysm and its association with intraoperative regional cerebral oxygen saturation (rScO2) and postoperative neurological outcomes, including delirium and cerebral infarction.
METHODS
This retrospective observational study included 133 patients with true aortic arch aneurysm who underwent preoperative magnetic resonance imaging (MRI). We evaluated the prevalence of carotid and intracranial arterial lesions. Symptomatic cerebral infarction and delirium, defined by the confusion assessment method for the intensive care unit, were evaluated for their association with preoperative cerebrovascular lesions. Additionally, changes in regional saturation of the cerebral tissue at different surgical phases were evaluated for patients with and without cerebrovascular lesions.
RESULTS
Fifteen (11.3%) patients experienced symptomatic cerebral infarction, and 64 (48.1%) had postoperative delirium. Preoperative MRI showed old infarction, microbleeds, significant carotid artery stenosis, and intracranial lesions in 21.1%, 14.3%, 10.5%, and 7.5% of the patients, respectively. White matter hyperintensities with Fazekas scale 2 were observed in 40.6% of the patients, while Fazekas scale 3 were observed in 18.8% of the patients. Preoperative MRI findings and postoperative neurological outcomes were not significantly different. Seventy-six patients underwent rScO2 monitoring intraoperatively. Changes in rScO2 in patients with and without carotid/cerebrovascular lesions were not significantly different. However, rScO2 was significantly lower in patients who developed cerebral infarction.
CONCLUSIONS
Significant carotid artery stenosis and intracranial lesions were observed in 10.5% and 7.5% of the patients, respectively. Although preoperative MRI findings and changes in rScO2 or postoperative outcomes showed no significant association, patients with postoperative cerebral infarction showed significantly lower rScO2 intraoperatively.
PubMed: 38883627
DOI: 10.21037/jtd-24-78 -
Cureus May 2024The no-reflow phenomenon is defined as the failure to restore coronary flow demonstrated by the reduced or missing flow in angiography despite the patent artery. There...
The no-reflow phenomenon is defined as the failure to restore coronary flow demonstrated by the reduced or missing flow in angiography despite the patent artery. There are pharmacological strategies proposed and studied to manage the no-reflow phenomenon. The medication groups used are purine nucleoside (adenosine), calcium channel blockers (verapamil, nicardipine), beta 2 receptor agonists (adrenaline, nitroprusside), fibrinolytic agents (streptokinase, tissue plasminogen activators), glycoprotein IIb/IIIa inhibitors (abciximab, tirofiban). We present a case of a woman hospitalized in non-ST elevation myocardial infarction (NSTEMI) conditions. The patient underwent coronary angiography, in which a single vessel coronary artery disease (CAD); left anterior descending (LAD) stenosis of 90% was found. In this condition, the patient underwent percutaneous coronary intervention (PCI) of LAD. The no-reflow phenomenon occurred with thrombolysis in myocardial infarction (TIMI) flow grade of 0 during the procedure. As a consequence, the patient presented chest pain and important hypotension (BP of 70/45). Because of the hypotensive state of the patient, we decided to administer intracoronary (IC) adrenaline directly. In our case, we used adrenaline as a first-line treatment for the no-flow phenomenon due to the hypotensive state during the PCI procedure. Generally, we initially use IC nitrate or IC adenosine to resolve the phenomenon, and when the no-reflow persists we use IC adrenaline because of its side effects mentioned above. Anyway, we believe that in specific cases of hypotension and bradycardia, the use of adrenaline as the first line of therapy should be considered.
PubMed: 38883139
DOI: 10.7759/cureus.60338 -
Cureus May 2024The Amplatzer Vascular Plug (AVP) series enables precise positioning and high migration resistance, allowing embolization in short segments; however, inadequate...
INTRODUCTION
The Amplatzer Vascular Plug (AVP) series enables precise positioning and high migration resistance, allowing embolization in short segments; however, inadequate embolization or recanalization may occasionally occur. We hypothesized that leaks may occur when AVPs are implanted in vessels with irregular lumen due to insufficient adherence to the vessel. This hypothesis was tested by experiments with a vascular model. We employed a coil packing technique between the AVP lobes to embolize internal iliac arteries with an irregular lumen.
METHODS
Saline was injected through the Y-shaped glass tubes of the stenotic and the smooth model (without stenotic lesion), and the amount of leakage was measured when the AVP was deployed. The feasibility and effectiveness of filling coils between the lobes of AVP II were evaluated. A total of 11 cases were retrospectively reviewed using this technique for internal iliac artery embolization prior to endovascular aortic repair.
RESULTS
The amount of leakage was significantly higher in the presence of stenotic lesions. Insertion of a 2.2 F microcatheter from the side of the proximal lobe of AVP II and filling of coils was achieved in all 11 cases. Follow-up contrast-enhanced CT showed no recanalization, leakage, or other obvious complications.
CONCLUSION
Coil packing technique around Amplatzer Vascular Plugs could be an effective method and a reliable option for arterial embolization, especially in vessels with irregular lumens.
PubMed: 38883083
DOI: 10.7759/cureus.60469