Cureus Jun 2024The purpose of this in vitro study was to evaluate the potential remineralization of enamel and dentine erosion lesions after the application of five different...
OBJECTIVE
The purpose of this in vitro study was to evaluate the potential remineralization of enamel and dentine erosion lesions after the application of five different toothpastes.
METHODOLOGY
A total of 104 enamel and dentine samples were prepared from maxillary third molars. Each group was divided according to the toothpaste application mode (topical = 56; brushing = 48) and the toothpaste used seven topical groups and six brushing groups (n = 8). The groups included negative control (NC), positive control (PC), Sensodyne Pronamel (SP), Regenerate (R), Regenerate with boosting serum (R+), Colgate Duraphat 5000 (CD), and tooth mousse (TM).
RESULTS
The statistical analysis showed significant surface microhardness (SMH) change. All enamel groups showed a significant decrease in SMH compared to NC for both application modes. However, no significance was recorded between test groups. Similar results were observed between dentine groups and their relevant controls for both application modes, except brushed R and R+ groups, which were insignificant to their NC. For topical groups, TM showed a significant increase in SMH. While R and R+ showed lower loss than SP and CD.
CONCLUSIONS
All tested agents offered a degree of remineralization in both enamel and dentine with no significant difference between agents in enamel groups while R, R+, and TM offered better results in dentine groups.
CLINICAL SIGNIFICANCE
For dentine groups, similar findings were observed with superior tooth surface protection with the application of TM over other agents. Tooth surface remineralization was achieved when agents were either applied topically or brushed over the surface.
PubMed: 38912082
DOI: 10.7759/cureus.62921 -
Scientific Reports Jun 2024This split-mouth blinded randomized controlled study compared the efficacy of a desensitizing agent with oxalate/resin polymer and a universal adhesive containing... (Randomized Controlled Trial)
Randomized Controlled Trial
Desensitizing efficacy of a universal dentin adhesive containing mesoporous bioactive glass on dentin hypersensitivity: a randomized clinical trial with a split-mouth model.
This split-mouth blinded randomized controlled study compared the efficacy of a desensitizing agent with oxalate/resin polymer and a universal adhesive containing mesoporous bioactive glass (MBG) for dentin hypersensitivity (DH) relief, using Schiff sensitivity score (SSS) and visual analog scale (VAS). Split quadrants containing teeth with DH were treated with either MS Coat ONE or Hi-Bond Universal with MBG as the functional additive. Assessments at baseline, immediately post-application, and at 1- and 2-week follow-ups used standardized stimulus protocols (air, cold, and acid). The SSS difference was the primary outcome, while the VAS difference was the secondary outcome. A mixed linear effect model performed statistical analysis. Immediate DH reduction occurred in response to air stimuli, with a significant decrease in Group HB than in Group MS (p = 0.0178). Cold stimulus reduction exhibited a gradual cumulative effect, with consistently greater reductions in Group HB than in Group MS (p ≤ 0.0377). Both groups effectively managed acidic stimuli, with no significant differences (p > 0.05). The VAS scores decreased gradually over the follow-up period (p < 0.0001). This study highlights the differential efficacy of treatments for various DH triggers and recommends specific approaches based on different stimulus types. The universal adhesive containing MBG demonstrated DH relief potential, promising efficacy identical to or superior to that of a dedicated desensitizing agent. Further research exploring the long-term efficacy and underlying mechanisms is warranted. The universal adhesive containing MBG can be adopted as an in-office desensitizing agent for DH relief. The desensitizing efficacy of universal adhesive matches or surpasses dedicated agents for air and cold stimuli.
Topics: Humans; Dentin Sensitivity; Female; Male; Dentin Desensitizing Agents; Adult; Glass; Treatment Outcome; Ceramics; Dental Cements; Young Adult; Middle Aged; Porosity
PubMed: 38886498
DOI: 10.1038/s41598-024-64404-x -
Journal of Pharmacy & Bioallied Sciences Apr 2024Complex anatomy of the root canal system results in incomplete debridement with mechanical instrumentation, leaving some areas or root canal walls untouched. There comes...
INTRODUCTION
Complex anatomy of the root canal system results in incomplete debridement with mechanical instrumentation, leaving some areas or root canal walls untouched. There comes the significance of endodontic irrigants with residual antibacterial substantivity which prolongs the post-antibiotic effect, thereby improving the success and predictability of endodontic treatment.
AIM
To comparatively evaluate the residual antibacterial substantivity of 2% chlorhexidine, Biopure MTAD and 2% chitosan against at intervals of 1, 14 and 28 days.
MATERIALS AND METHODS
Seventy-five therapeutically extracted permanent single rooted mandibular premolars teeth were selected. Dentin blocks of 4 mm thickness were prepared and enlarged to 1.6 mm. The autoclaved blocks were inoculated with 24-hour colonies of pure cultures of for 14 days. After the contamination period, canals of each dentin block were irrigated with 5 ml of sterile saline and dried with sterile paper points. A total of 75 dentin blocks were randomly divided into five groups as follows: Group A (21 specimens): 2% chlorhexidine, Group B (21 specimens): Biopure MTAD, Group C (21 specimens): 2% chitosan, Group D (6 specimens): positive control (infected dentin tubes) and Group E (six specimens): negative control (sterile dentin tubes). Then, the lumens of dentin blocks were irrigated with the respective irrigants for 10 mins and were dried using sterile paper points. The specimens were then incubated at 37°C for 28 days to maintain humidity. At experimental intervals of 1, 14 and 28 days, dentin shavings were removed from the canals of respective groups by circumferential filing with sterile no. 35 Hedstrom files. The powdered dentin samples obtained with each dentin block were observed for colony forming units (CFUs) using a Digital Colony counter and were expressed as CFUs/mL.
RESULT
All the irrigants in the study showed a significant decrease in CFUs from day 1 to day 28 indicating that they have residual antibacterial substantivity against . Group B (Biopure MTAD) showed significantly least mean CFUs compared to Group A (2% CHX) and Group C (2% chitosan) against at B1(day 1), B2(day 14) and B3(day 28). Group A (2% CHX) showed significantly higher mean CFUs than Group C (2% chitosan) at A1(day 1). Group C (2% chitosan) showed significantly higher mean CFUs compared to Group A (2% CHX) at C2(day 14) and C3 (day 28).
CONCLUSION
MTAD showed statistically higher residual antibacterial substantivity against at experimental periods of 1, 14 and 28 days. The residual antibacterial effect of 2% chitosan was better compared to 2% CHX at day 1. The residual antimicrobial substantivity of 2% CHX was higher compared to 2% chitosan at intervals of 14 and 28 days.
PubMed: 38882860
DOI: 10.4103/jpbs.jpbs_693_23 -
Journal of Pharmacy & Bioallied Sciences Apr 2024The electrochemical dissolution method of instrument retrieval emphasizes on the dissolution of the instrument rather than sacrificing dentine. Most of the studies...
OBJECTIVE
The electrochemical dissolution method of instrument retrieval emphasizes on the dissolution of the instrument rather than sacrificing dentine. Most of the studies conducted for electrochemical dissolution used fluoride-containing electrolytes and were performed inside a beaker. In this study, we used chloride-based fluids as electrolytes.
MATERIALS AND METHODS
Fifty extracted mandibular first premolars were divided into five groups based on the electrolytes used. Canals were enlarged to ProTaper Universal F2, and files were intentionally broken inside the canal. These specimens were subjected to electrochemical characterization by applying the potential of 9V for 20 min. Optical images were taken to assess the change in surface topography. The results were analyzed statistically by one-way analysis of variance (analysis of variance [ANOVA]).
RESULTS
The rate of dissolution based on the electrolyte used decreased in the following order, viz. Tyrode's solution>artificial saliva>normal saline>Ringer's lactate/physiological serum.
CONCLUSION
Apart from fluoride, chloride-based electrolytes could be an efficient alternative.
PubMed: 38882790
DOI: 10.4103/jpbs.jpbs_1225_23 -
Clinical Oral Investigations Jun 2024Fixed orthodontic appliances may increase the risk for caries and white spot lesions. The aim of this retrospective study was to determine the long-term associations...
OBJECTIVES
Fixed orthodontic appliances may increase the risk for caries and white spot lesions. The aim of this retrospective study was to determine the long-term associations between both in orthodontic patients.
MATERIALS AND METHODS
103 patients aged 36.6 ± 6.5 years whose fixed appliance orthodontic treatment had finished at least 15 years ago were included. Current clinical data and photographs (T3), panoramic x-ray and photographs from before treatment (T0), after debonding (T1) and at 2-year follow-up (T2) were available. Parameters of interest were dentine caries, "Missing/Filled Teeth" (MFT), "White Spot Lesion" (WSL) index and "Periodontal Screening and Recording" index (PSR; T3 only).
RESULTS
At T0, 30.4% had no caries experience decreasing to 25.6%, 22.4% and 6.8% at T1, T2 and T3 resp. The median MFT (95% CI) at T0, T1, T2 and T3 was 2 (1;3), 3 (2;4), 3 (2;4) and 7 (6;9) resp. increasing significantly at each time point (p < 0.001 each); 30.1% had WSL at debonding. Patients with caries experience at T0 had a 2.4-fold increased risk of WSL at debonding. Dentine caries, caries experience and WSL at T1 were significantly associated with incident caries at T2, but not at T3. PSR at T3 had a significant association with previous caries incidence and WSL.
CONCLUSIONS
Caries experience prior to orthodontic treatment may constitute a risk indicator for WSL, and caries experience and WSL at its end for caries incidence in the near term.
CLINICAL RELEVANCE
Present caries and WSL may help identifying orthodontic patients with special need for prevention and counselling.
Topics: Humans; Dental Caries; Retrospective Studies; Male; Female; Adult; Radiography, Panoramic; Risk Factors; Orthodontic Appliances, Fixed; DMF Index
PubMed: 38861170
DOI: 10.1007/s00784-024-05752-w -
BMC Oral Health Jun 2024This study investigated the effect of carbodiimide (EDC) combined with Clearfil SE self-etch adhesive on the shear bond strength (SBS), crosslinking degree, denaturation...
BACKGROUND
This study investigated the effect of carbodiimide (EDC) combined with Clearfil SE self-etch adhesive on the shear bond strength (SBS), crosslinking degree, denaturation temperature, and enzyme activity of dentin in vitro.
MATERIALS AND METHODS
Collected human sound third molars were randomly divided into different groups with or without EDC treatment (0.01-1 M). The specimens (n = 16)were stored for 24 h (immediate) or 12 months (aging) before testing the SBS. Fine dentin powder was obtained and treated with the same solutions. Then the crosslinking degree, denaturation temperature (Td), and enzyme activity were tested. Statistical analysis was performed using a one-way analysis of variance (ANOVA) to compare the differences of data between groups (α = 0.05).
RESULTS
There was a significant drop in immediate SBS and more adhesive fracture of 1.0 M EDC group, while there were no significant differences among the other groups. SEM showed a homogeneous interface under all treatments. After 12 months of aging, the SBS significantly decreased. Less decreases of SBS in the 0.3 and 0.5 M groups were found. Due to thermal and enzymatical properties consideration, the 0.3 and 0.5 M treatments also showed higher cross-link degree and Td with lower enzyme activity.
CONCLUSION
0.3 and 0.5 M EDC may be favorable for delaying the aging of self-etch bond strength for 12 months. But it is still needed thoroughly study.
Topics: Humans; Carbodiimides; Resin Cements; Shear Strength; Materials Testing; Dentin; Microscopy, Electron, Scanning; Dentin-Bonding Agents; Dental Stress Analysis; Cross-Linking Reagents; Dental Bonding; In Vitro Techniques; Acid Etching, Dental; Molar, Third; Temperature; Time Factors; Surface Properties
PubMed: 38849778
DOI: 10.1186/s12903-024-04415-2 -
Materials (Basel, Switzerland) May 2024This study investigated the effect of 3 s light-curing with a high-power LED curing unit on the shear bond strength of bulk-fill composites. Four bulk-fill composites...
This study investigated the effect of 3 s light-curing with a high-power LED curing unit on the shear bond strength of bulk-fill composites. Four bulk-fill composites were bonded to dentin with a universal adhesive (Scotchbond Universal Plus): two materials designed for rapid curing (Tetric PowerFill and Tetric PowerFlow) and two controls (Filtek One Bulk Fill Restorative and SDR Plus Bulk Fill Flowable). The 4 mm composite layer was light-cured with Bluephase PowerCure for 20 s at 1000 mW/cm ("20 s") or for 3 s at 3000 mW/cm ("3 s"). The samples were stored at 37 °C in distilled water and tested after 1, 6 and 12 months. The samples polymerised in the "3 s" mode had statistically similar or higher bond strength than the samples cured in "20 s" mode, except for the Tetric PowerFlow (1 month) and SDR+ (6 month). The flowable materials Tetric PowerFlow and SDR Plus initially showed the highest values in the "3 s" and "20 s" groups, which decreased after 12 months. The bond strength was statistically similar for all materials and curing protocols after 12 months, except for Tetric PowerFill cured with the "3 s" protocol (21.22 ± 5.0 MPa), which showed the highest value. Tetric PowerFill showed the highest long-term bond strength. While "3 s" curing resulted in equal or better shear bond strength, its use can only be recommended for a material with an AFCT agent such as Tetric PowerFill.
PubMed: 38793364
DOI: 10.3390/ma17102297 -
Journal of Functional Biomaterials May 2024The aim of this study was to evaluate the effect of different irrigating solutions as well as their combination and activation modes on root canal dentin microhardness.... (Review)
Review
The aim of this study was to evaluate the effect of different irrigating solutions as well as their combination and activation modes on root canal dentin microhardness. The protocol was registered in PROSPERO and PRISMA guidelines were followed. The structured question was as follows: "Which type of irrigating solution used in endodontic treatment causes more change in dentin microhardness?" The literature was screened via PubMed, Google Scholar, Scopus, and Science Direct. The last search was carried out in February 2023 with English language restriction. Two reviewers independently performed screening and evaluation of articles. A total of 470 articles were retrieved from all the databases, whereas only 114 articles were selected for full-text analysis. After applying eligibility criteria, 44 studies were evaluated and included in this review. The results showed that with increased contact time with irrigants, dentin microhardness decreases. Increased contact time with sodium hypochlorite (NaOCl) was associated with more reduction in dentin microhardness compared with other irrigants. Other irrigants, with the exception of distilled water, including EDTA, citric acid, herbal irrigants, glycolic acid, phytic acid, etc., in this study significantly decreased dentin microhardness. The maximum reduction in dentin microhardness was seen with 2.5% NaOCl after 15 min of contact time. The use of irrigating solutions alters the chemical composition of dentin, thereby decreasing its microhardness, which affects the clinical performance of endodontically treated teeth.
PubMed: 38786643
DOI: 10.3390/jfb15050132 -
Journal of Functional Biomaterials May 2024There is a vast amount of published literature concerning dental veneers; however, the effects of tooth preparation, aging, veneer type, and resin cement type on the... (Review)
Review
There is a vast amount of published literature concerning dental veneers; however, the effects of tooth preparation, aging, veneer type, and resin cement type on the failure of dental veneers in laboratory versus clinical scenarios are not clear. The purpose of the present narrative review was to determine the principal factors associated with failures of dental veneers in laboratory tests and to understand how these factors translate into clinical successes/failures. Articles were identified and screened by the lead author in January 2024 using the keywords ''dental veneer", "complication", "survival rate", "failure", and "success rate" using PubMed/Medline, Scopus, Google Scholar, and Science Direct. The inclusion criteria included articles published between January 1999 and January 2024 on the topics of preparation of a tooth, aging processes of the resin cement and veneer, translucency, thickness, fabrication technique of the veneer; shade, and thickness of the resin cement. The exclusion criteria included articles that discussed marginal and internal fit, microhardness, water sorption, solubility, polishability, occlusal veneers, retention, surface treatments, and wear. The results of the present review indicated that dental veneers generally have a high survival rate (>90% for more than 10 years). The amount of preserved enamel layer plays a paramount role in the survival and success rates of veneers, and glass-ceramic veneers with minimal/no preparation showed the highest survival rates. Fracture was the primary failure mechanism associated with decreased survival rate, followed by debonding and color change. Fractures increased in the presence of parafunctional activities. Fewer endodontic complications were associated with veneer restorations. No difference was observed between the maxillary and mandibular teeth. Fractures can be reduced by evaluation of occlusion immediately after cementation and through the use of high-strength veneer materials, resin cements with low moduli, and thin layers of highly polished veneers. Debonding failures can be reduced with minimal/no preparation, and immediate dentin sealing should be considered when dentin is exposed. Debonding can also be reduced by preventing contamination from blood, saliva, handpiece oil, or fluoride-containing polishing paste; through proper surface treatment (20 s of hydrofluoric acid etching for glass ceramic followed by silane for 60 s); and through use of light-cured polymerization for thin veneers. Long-term color stability may be maintained using resin cements with UDMA-based resin, glass ceramic materials, and light-cure polymerization with thin veneers.
PubMed: 38786642
DOI: 10.3390/jfb15050131 -
JPMA. the Journal of the Pakistan... May 2024To compare the effect of propolis and gluma desensitisers on the management of dentin hypersensitivity. (Randomized Controlled Trial)
Randomized Controlled Trial Comparative Study
OBJECTIVE
To compare the effect of propolis and gluma desensitisers on the management of dentin hypersensitivity.
METHODS
The single-blind, randomised controlled trial was conducted at the Department of Operative Dentistry, Dr Ishrat ul Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, Karachi, from October 2020 to September 2021, and comprised patients with dentin hypersensitivity who had pain scores of at least 2 on the visual analogue scale. The teeth were randomised into propolis group A and Gluma group B. Baseline pain scores were assessed using visual analogue scale and Schiff's sensitivity scores and compared with scores immediately after the intervention, and then after one week and one month of the intervention. Data was analysed using SPSS 23.
RESULTS
Of the 22 patients, 12(54.5%) were females and 10(45.4%) were males. Of the 80 teeth, there were 40(50%) in each of the 2 groups. Significant reduction was observed in dentin hypersensitivity immediately after the application of the desensitising agents (p<0.05). However, after one month, Gluma was more effective than propolis (p<0.05).
CONCLUSIONS
Both Gluma and propolis were found to be effective desensitising agents, but the effectiveness of propolis decreased over one month.
CLINICAL TRIAL NUMBER
Clinical Trials.gov: NCT04819867.
Topics: Humans; Propolis; Dentin Sensitivity; Female; Male; Adult; Dentin Desensitizing Agents; Single-Blind Method; Methacrylates; Pain Measurement; Young Adult; Middle Aged; Glutaral
PubMed: 38783427
DOI: 10.47391/JPMA.9924