Materials (Basel, Switzerland) Jun 2024This research aims to investigate the influence of model height employed in the deep drawing of orthodontic aligner sheets on force transmission and aligner thickness....
This research aims to investigate the influence of model height employed in the deep drawing of orthodontic aligner sheets on force transmission and aligner thickness. Forty aligner sheets (Zendura FLX) were thermoformed over four models of varying heights (15, 20, 25, and 30 mm). Normal contact force generated on the facial surface of the upper right central incisor (Tooth 11) was measured using pressure-sensitive films. Aligner thickness around Tooth 11 was measured at five points. A digital caliper and a micro-computed tomography (µ-CT) were employed for thickness measurements. The normal contact force exhibited an uneven distribution across the facial surface of Tooth 11. Model 15 displayed the highest force (88.9 ± 23.2 N), while Model 30 exhibited the lowest (45.7 ± 15.8 N). The force distribution was more favorable for bodily movement with Model 15. Thickness measurements revealed substantial thinning of the aligner after thermoforming. This thinning was most pronounced at the incisal edge (50% of the original thickness) and least at the gingivo-facial part (85%). Additionally, there was a progressive reduction in aligner thickness with increasing model height, which was most significant on the facial tooth surfaces. We conclude that the thermoplastic aligner sheets undergo substantial thinning during the thermoforming process, which becomes more pronounced as the height of the model increases. As a result, there is a decrease in both overall and localized force transmission, which could lead to increased tipping by the aligner and a diminished ability to achieve bodily movement.
PubMed: 38930391
DOI: 10.3390/ma17123019 -
Materials (Basel, Switzerland) Jun 2024Barium zirconate (BaZrO, BZO), which exhibits superior mechanical, thermal, and chemical stability, has been widely used in many applications. In dentistry, BZO is used...
Barium zirconate (BaZrO, BZO), which exhibits superior mechanical, thermal, and chemical stability, has been widely used in many applications. In dentistry, BZO is used as a radiopacifier in mineral trioxide aggregates (MTAs) for endodontic filling applications. In the present study, BZO was prepared using the sol-gel process, followed by calcination at 700-1000 °C. The calcined BZO powders were investigated using X-ray diffraction and scanning electron microscopy. Thereafter, MTA-like cements with the addition of calcined BZO powder were evaluated to determine the optimal composition based on radiopacity, diametral tensile strength (DTS), and setting times. The experimental results showed that calcined BZO exhibited a majority BZO phase with minor zirconia crystals. The crystallinity, the percentage, and the average crystalline size of BZO increased with the increasing calcination temperature. The optimal MTA-like cement was obtained by adding 20% of the 700 °C-calcined BZO powder. The initial and final setting times were 25 and 32 min, respectively. They were significantly shorter than those (70 and 56 min, respectively) prepared with commercial BZO powder. It exhibited a radiopacity of 3.60 ± 0.22 mmAl and a DTS of 3.02 ± 0.18 MPa. After 28 days of simulated oral environment storage, the radiopacity and DTS decreased to 3.36 ± 0.53 mmAl and 2.84 ± 0.27 MPa, respectively. This suggests that 700 °C-calcined BZO powder has potential as a novel radiopacifier for MTAs.
PubMed: 38930384
DOI: 10.3390/ma17123015 -
Materials (Basel, Switzerland) Jun 2024Although advancements in CAD/CAM technology allow for more personalized treatments, it is not clear how modifications in the CAD/CAM milling process could affect the...
Although advancements in CAD/CAM technology allow for more personalized treatments, it is not clear how modifications in the CAD/CAM milling process could affect the restoration surface conditions and their mechanical behavior. The objective of this study was to evaluate the effect of different CAD/CAM milling protocols on the topography and fracture behavior of zirconia monolithic crowns (3Y-PSZ) subjected to a chewing simulation. Monolithic 3Y-PSZ premolar crowns were milled using three protocols ( = 13) (slow (S), normal (N), and fast (F)). Crowns were cemented on a dentin analog abutment and subjected to mechanical aging (200 N, 2 Hz, 1,500,000 cycles, 37 °C water). Surviving crowns were subjected to compressive load test and analyzed using fractography. Fracture load data were analyzed with two-parameter Weibull analysis. The surface topography of the crowns was examined with a stereomicroscope and a 3D non-contact profiler. All crowns survived the chewing simulation. Crowns milled using the F protocol had the greatest characteristic fracture load, while crowns produced with the S protocol showed high Weibull modulus. Groups N and S had a more uniform surface and detailed occlusal anatomy than group F. The CAD/CAM milling protocol affected the topography and mechanical behavior of 3Y-PSZ monolithic crowns.
PubMed: 38930350
DOI: 10.3390/ma17122981 -
Materials (Basel, Switzerland) Jun 2024Fluorescence-aided identification technique (FIT) studies for orthodontic resins are relatively new, using an arbitrary selection of resins, lights, and work parameters....
BACKGROUND
Fluorescence-aided identification technique (FIT) studies for orthodontic resins are relatively new, using an arbitrary selection of resins, lights, and work parameters. In order to provide FIT guidelines for optimal visualization, the objectives of this study were to describe the electromagnetic characteristics of fluorescent orthodontic resins, determine appropriate light specification, and describe light and work parameter effects on resin fluorescence.
METHODS
This in vitro study assessed five fluorescent orthodontic resins and a non-fluorescent control resin using spectrophotometry, a scaled image analysis of 25 μm thick resins to compare intensities, and a visual assessment. Light sources varied by flashlight lens (narrow [N], average [X], and magnified [Z]) and UV intensity (X and X High). Work parameters included distance (20-300 mm) and angulation (15-70°). Visual scores were assigned to determine discernibility.
RESULTS
The average excitation maxima was 384 nm. Fluorescence increased with more direct UV light exposure. The highest intensity was recorded with Light X High at 50 mm and 70°. Visual assessment followed image analysis trends, and fluorescence was clinically discernable for all 25 μm thick samples.
CONCLUSIONS
Excitation wavelength range of 395-405 nm is appropriate for FIT illumination. All resins were anisotropic and showed greater fluorescence with greater angle, higher UV intensity, and closer proximity.
PubMed: 38930329
DOI: 10.3390/ma17122961 -
Materials (Basel, Switzerland) Jun 2024Implantoplasty is a technique increasingly used to remove the biofilm that causes peri-implantitis on dental implants. This technique of mechanization of the titanium...
Implantoplasty is a technique increasingly used to remove the biofilm that causes peri-implantitis on dental implants. This technique of mechanization of the titanium surface makes it possible to eliminate bacterial colonies, but it can generate variations in the properties of the implant. These variations, especially those in fatigue resistance and electrochemical corrosion behavior, have not been studied much. In this work, fatigue tests were performed on 60 dental implants without implantoplasty, namely 30 in air and 30 in Hank's solution at 37 °C, and 60 with implatoplasty, namely 30 in air and 30 in Hank's solution at 37 °C, using triaxial tension-compression and torsion stresses simulating human chewing. Mechanical tests were performed with a Bionix servo-hydraulic testing machine and fracture surfaces were studied by scanning electron microcopyElectrochemical corrosion tests were performed on 20 dental implants to determine the corrosion potentials and corrosion intensity for control implants and implantoplasty implants. Studies of titanium ion release to the physiological medium were carried out for each type of dental implants by Inductively Coupled-Plasma Mass Spectrometry at different immersion times at 37 °C. The results show a loss of fatigue caused by the implantoplasty of 30%, observing that the nucleation points of the cracks are in the areas of high deformation in the areas of the implant neck where the mechanization produced in the treatment of the implantoplasty causes an exaltation of fatigue cracks. It has been observed that tests performed in Hank's solution reduce the fatigue life due to the incorporation of hydrogen in the titanium causing the formation of hydrides that embrittle the dental implant. Likewise, the implantoplasty causes a reduction of the corrosion resistance with some pitting on the machined surface. Ion release analyses are slightly higher in the implantoplasted samples but do not show statistically significant differences. It has been observed that the physiological environment reduces the fatigue life of the implants due to the penetration of hydrogen into the titanium forming titanium hydrides which embrittle the implant. These results should be taken into account by clinicians to determine the convenience of performing a treatment such as implantoplasty that reduces the mechanical behavior and increases the chemical degradation of the titanium dental implant.
PubMed: 38930312
DOI: 10.3390/ma17122944 -
Materials (Basel, Switzerland) Jun 2024Direct scanning of silicone impressions is a valid technique. However, studies in implant-supported rehabilitations are lacking. This in vitro study aims to compare the...
Direct scanning of silicone impressions is a valid technique. However, studies in implant-supported rehabilitations are lacking. This in vitro study aims to compare the trueness of impressions obtained with two types of silicone and their corresponding stone casts, using two laboratory scanners in a full-arch implant rehabilitation. A master cast with six dental implants was scanned with a 12-megapixel scanner to obtain a digital master cast. Ten implant impressions were made using two silicones (Zhermack and Coltene) with the open-tray technique. The impressions and stone casts were scanned by two extraoral scanners (Identica T500, Medit; and S600 ARTI, Zirkonzhan). Trueness was assessed by comparing linear and angular distances in digital casts with the master cast. A < 0.05 significance level was considered. The results showed that for the linear measurements, 72% were higher than the master cast measurements, and no consistent pattern was observed in the angular measurements. The greatest deviations were detected between the most posterior implants, with mean values ranging between 173 and 314 µm. No significant differences were found between scanners. However, differences were observed in the distances between silicones (46.7%) and between impressions and stone casts (73.3%). This work demonstrates that the direct scanning of silicone impressions yields results comparable to those obtained from scanning gypsum casts in full-arch implant-supported rehabilitation.
PubMed: 38930301
DOI: 10.3390/ma17122932 -
Materials (Basel, Switzerland) Jun 2024This paper reports the results of our study on electrochemical polishing of titanium and a Ti-based alloy using non-aqueous electrolyte. It was shown that...
This paper reports the results of our study on electrochemical polishing of titanium and a Ti-based alloy using non-aqueous electrolyte. It was shown that electropolishing ensured the removal of surface defects, thereby providing surface smoothing and decreasing surface roughness. The research was conducted using samples made of titanium and TiAlV alloy, as well as implant system elements: implant analog, multiunit, and healing screw. Electropolishing was carried out under a constant voltage (10-15 V) with a specified current density. The electrolyte used contained methanol and sulfuric acid. The modified surface was subjected to a thorough analysis regarding its surface morphology, chemical composition, and physicochemical properties. Scanning electron microscope images and profilometer tests of roughness confirmed significantly smoother surfaces after electropolishing. The surface profile analysis of processed samples also yielded satisfactory results, showing less imperfections than before modification. The EDX spectra showed that electropolishing does not have significant influence on the chemical composition of the samples.
PubMed: 38930203
DOI: 10.3390/ma17122832 -
Journal of Clinical Medicine Jun 2024Dental implants have always played an important role in dentistry and have been used to replace missing teeth since around 600 AD. They can be classified into three... (Review)
Review
Dental implants have always played an important role in dentistry and have been used to replace missing teeth since around 600 AD. They can be classified into three groups: endosteal, subperiosteal, and transosteal. Over time, different materials have been used to manufacture dental implants and these, in turn, can be divided into three groups: metals, ceramics, and polymers. Today, the most commonly used treatment for edentulism is the use of endosteal implants. However, such an approach cannot be used in patients with severe alveolar ridge atrophy and, in such cases, custom subperiosteal implants are an alternative. This review article focuses on historical developments and improvements that have been made over recent years in treatment options for patients suffering from edentulism and significant resorption of the alveolar ridge. These treatment options involve the utilization of custom subperiosteal implants. This paper looks at the historical evolution of these implants, the significance of diagnostic imaging, and the application of the contemporary methods of production, such as CAD-CAM and additive manufacturing. The research emphasizes the importance of accuracy and personalization provided by these emerging technologies that have rendered subperiosteal implants a more feasible and less intrusive alternative for patients suffering from significant bone loss.
PubMed: 38930111
DOI: 10.3390/jcm13123582 -
Journal of Clinical Medicine Jun 2024Mandibular defects resulting from oncological treatment pose significant aesthetic and functional challenges due to the involvement of bone and soft tissues. Immediate... (Review)
Review
Mandibular defects resulting from oncological treatment pose significant aesthetic and functional challenges due to the involvement of bone and soft tissues. Immediate reconstruction is crucial to address complications such as malocclusion, mandibular deviation, temporomandibular joint (TMJ) changes, and soft tissue retraction. These issues can lead to functional impairments, including difficulties in chewing, swallowing, and speech. The fibula flap is widely used for mandibular reconstruction due to its long bone segment and robust vascular supply, though it may not always provide adequate bone height for optimal dental rehabilitation. This systematic review aims to determine if the double-barreled fibula flap (DBFF) configuration is a viable alternative for mandibular reconstruction and to evaluate the outcomes of dental implants placed in this type of flap. This study adhered to the Cochrane Collaboration criteria and PRISMA guidelines and was registered on the International Platform of Registered Systematic Review and Meta-Analysis Protocols Database (INPLASY2023120026). We included clinical studies published in English, Spanish, or French that focused on adult patients undergoing segmental mandibulectomy followed by DBFF reconstruction and dental rehabilitation. Data sources included Medline/PubMed, the Cochrane Library, EMBASE, Scopus, and manual searches. Two reviewers independently screened and selected studies, with discrepancies resolved by a third reviewer. Data extraction captured variables such as publication year, patient demographics, number of implants, follow-up duration, flap survival, implant failure, and aesthetic outcomes. The risk of bias was assessed using the JBI appraisal tool, and the certainty of evidence was evaluated using the GRADE approach. A total of 17 clinical studies were included, evaluating 245 patients and 402 dental implants. The average patient age was 43.7 years, with a mean follow-up period of 34.3 months. Flap survival was high, with a 98.3% success rate and only four flap losses. The implant failure rate was low at 1.74%. Esthetic outcomes were varied, with only three studies using standardized protocols for evaluation. The overall certainty of evidence for flap survival was moderate, low for implant failure, and very low for aesthetics due to the subjective nature of assessments and variability in reporting. The primary limitations of the evidence included in this review are the observational design of the studies, leading to an inherent risk of bias, inconsistency in reporting methods, and imprecision in outcome measures. Additionally, the subjective nature of aesthetic evaluations and the variability in assessment tools further limit the reliability of the findings. The DBFF technique demonstrates excellent outcomes for mandibular reconstruction, with high flap survival and low implant failure rates, making it a viable option for dental rehabilitation. However, the evidence for aesthetic outcomes is less certain, highlighting the need for more rigorous and standardized research. This review supports the DBFF as a good alternative for mandibular reconstruction with successful dental implant integration, although further studies are needed to enhance the reliability of aesthetic evaluations.
PubMed: 38930078
DOI: 10.3390/jcm13123547 -
Journal of Clinical Medicine Jun 2024The purpose of this preliminary study was to evaluate the diagnostic performance of an AI-driven platform, Diagnocat (Diagnocat Ltd., San Francisco, CA, USA), for...
The purpose of this preliminary study was to evaluate the diagnostic performance of an AI-driven platform, Diagnocat (Diagnocat Ltd., San Francisco, CA, USA), for assessing endodontic treatment outcomes using panoramic radiographs (PANs). The study included 55 PAN images of 55 patients (15 males and 40 females, aged 12-70) who underwent imaging at a private dental center. All images were acquired using a Hyperion X9 PRO digital cephalometer and were evaluated using Diagnocat, a cloud-based AI platform. The AI system assessed the following endodontic treatment features: filling probability, obturation adequacy, density, overfilling, voids in filling, and short filling. Two human observers independently evaluated the images, and their consensus served as the reference standard. The diagnostic accuracy metrics were calculated. The AI system demonstrated high accuracy (90.72%) and a strong F1 score (95.12%) in detecting the probability of endodontic filling. However, the system showed variable performance in other categories, with lower accuracy metrics and unacceptable F1 scores for short filling and voids in filling assessments (8.33% and 14.29%, respectively). The accuracy for detecting adequate obturation and density was 55.81% and 62.79%, respectively. The AI-based system showed very high accuracy in identifying endodontically treated teeth but exhibited variable diagnostic accuracy for other qualitative features of endodontic treatment.
PubMed: 38929931
DOI: 10.3390/jcm13123401