-
Journal of Clinical Medicine Jun 2024: Patients with liver pathology benefit from image-guided interventions. Training for interventional procedures is recommended to be performed on liver phantoms until a...
: Patients with liver pathology benefit from image-guided interventions. Training for interventional procedures is recommended to be performed on liver phantoms until a basic proficiency is reached. In the last 40 years, several attempts have been made to develop materials to mimic the imaging characteristics of the human liver in order to create liver phantoms. There is still a lack of accessible, reproducible and cost-effective soft liver phantoms for image-guided procedure training. : Starting from a CT-scan DICOM file, we created a 3D-printed liver mold using InVesalius (Centro de Tecnologia da informação Renato Archer CTI, InVesalius 3 open-source software, Campinas, Brazil) for segmentation, Autodesk Fusion 360 with Netfabb (Autodesk software company, Fusion 360 2.0.19426 with Autodesk Netfabb Premium 2023.0 64-Bit Edition, San Francisco, CA, USA) for 3D modeling and Stratasys Fortus 380 mc 3D printer (Stratasys 3D printing company, Fortus 380 mc 3D printer, Minneapolis, MN, USA). Using the 3D-printed mold, we created 14 gelatin-based liver phantoms with 14 different recipes, using water, cast sugar and dehydrated gelatin, 32% fat bovine milk cream with intravenous lipid solution and technical alcohol in different amounts. We tested all these phantoms as well as ex vivo pig liver and human normal, fatty and cirrhotic liver by measuring the elasticity, shear wave speed, ultrasound attenuation, CT-scan density, MRI signal intensity and fracture force. We assessed the results of the testing performed, as well as the optical appearance on ultrasound, CT and MRI, in order to find the best recipe for gelatin-based phantoms for image-guided procedure training. : After the assessment of all phantom recipes, we selected as the best recipe for transparent phantoms one with 14 g of gelatin/100 mL water and for opaque phantom, the recipes with 25% cream. : These liver gelatin-based phantom recipes are an inexpensive, reproducible and accessible alternative for training in image-guided and diagnostic procedures and will meet most requirements for valuable training.
PubMed: 38929969
DOI: 10.3390/jcm13123440 -
Journal of Personalized Medicine May 2024Chest pain is a prevalent reason for emergency room referrals and presents diagnostic challenges. The physician must carefully differentiate between cardiac and...
BACKGROUND
Chest pain is a prevalent reason for emergency room referrals and presents diagnostic challenges. The physician must carefully differentiate between cardiac and noncardiac causes, including various vascular and extracardiovascular conditions. However, it is crucial not to overlook serious conditions such as acute coronary syndrome (ACS). Diagnosis of acute myocardial infarction (AMI) and early discharge management become difficult when traditional clinical criteria, ECG, and troponin values are insufficient. Recently, the focus has shifted to a "multi-marker" approach to improve diagnostic accuracy and prognosis in patients with chest pain.
METHODS
This observational, prospective, single-center study involved, with informed consent, 360 patients presenting to the emergency department with typical chest pain and included a control group of 120 healthy subjects. In addition to routine examinations, including tests for hsTnI (Siemens TNIH kit), according to the 0-1 h algorithm, biochemical markers sST2 (tumorigenicity suppression-2) and suPAR (soluble urokinase plasminogen activator receptor) were also evaluated for each patient. A 12-month follow-up was conducted to monitor outcomes and adverse events.
RESULTS
We identified two groups of patients: a positive one (112 patients) with high levels of hsTnI, sST2 > 24.19 ng/mL, and suPAR > 2.9 ng/mL, diagnosed with ACS; and a negative one (136 patients) with low levels of hsTnI, suPAR < 2.9 ng/mL, and sST2 < 24.19 ng/mL. During the 12-month follow-up, no adverse events were observed in the negative group. In the intermediate group, patients with hsTnI between 6 ng/L and the ischemic limit, sST2 > 29.1 ng/mL and suPAR > 2.9 ng/mL, showed the highest probability of adverse events during follow-up, while those with sST2 < 24.19 ng/mL and suPAR < 2.9 ng/mL had a better outcome with no adverse events at 12 months.
CONCLUSION
Our data suggest that sST2 and suPAR, together with hsTnI, may be useful in the prognosis of cardiovascular patients with ACS, providing additional information on endothelial damage. These biomarkers could guide the clinical decision on further diagnostic investigations. In addition, suPAR and sST2 emerge as promising for event prediction in patients with chest pain. Their integration into the standard approach in PS could facilitate more efficient patient management, allowing safe release or timely admission based on individual risk.
PubMed: 38929785
DOI: 10.3390/jpm14060564 -
Medicina (Kaunas, Lithuania) Jun 2024Chronic endometritis (CE) is an inflammatory pathologic condition of the uterine mucosa characterized by unusual infiltration of CD138(+) endometrial stromal plasmacytes... (Review)
Review
Chronic endometritis (CE) is an inflammatory pathologic condition of the uterine mucosa characterized by unusual infiltration of CD138(+) endometrial stromal plasmacytes (ESPCs). CE is often identified in infertile women with unexplained etiology, tubal factors, endometriosis, repeated implantation failure, and recurrent pregnancy loss. Diagnosis of CE has traditionally relied on endometrial biopsy and histopathologic/immunohistochemistrical detection of ESPCs. Endometrial biopsy, however, is a somewhat painful procedure for the subjects and does not allow us to grasp the whole picture of this mucosal tissue. Meanwhile, fluid hysteroscopy has been recently adopted as a less-invasive diagnostic modality for CE. We launched the ARCHIPELAGO (ARChival Hysteroscopic Image-based Prediction for histopathologic chronic Endometritis in infertile women using deep LeArninG mOdel) study to construct the hysteroscopic CE finding-based prediction tools for histopathologic CE. The development of these deep learning-based novel models and computer-aided detection/diagnosis systems potentially benefits infertile women suffering from this elusive disease.
Topics: Humans; Female; Deep Learning; Endometritis; Hysteroscopy; Chronic Disease; Infertility, Female; Endometrium
PubMed: 38929589
DOI: 10.3390/medicina60060972 -
Posterior-Only T11 Vertebral Column Resection for Pediatric Congenital Kyphosis Surgical Correction.Medicina (Kaunas, Lithuania) May 2024: Congenital kyphosis is a spinal deformity that arises from the inadequate anterior development or segmentation of the vertebrae in the sagittal plane during the...
: Congenital kyphosis is a spinal deformity that arises from the inadequate anterior development or segmentation of the vertebrae in the sagittal plane during the initial embryonic stage. Consequently, this condition triggers atypical spinal growth, leading to the manifestation of deformity. Concurrently, other congenital abnormalities like renal or cardiac defects within the gastrointestinal tract may co-occur with spinal deformities due to their shared formation timeline. In light of the specific characteristics of the deformity, the age range of the patient, deformity sizes, and neurological conditions, surgical intervention emerges as the optimal course of action for such cases. The selection of the appropriate surgical approach is contingent upon the specific characteristics of the anomaly. : This investigation illustrates the utilization of a surgical posterior-only strategy for correcting pediatric congenital kyphoscoliosis through the implementation of a vertebral column resection method along with spine reconstruction employing a mesh cage. The individual in question, a 16-year-old female, exhibited symptoms such as a progressive rib hump, shoulder asymmetry, and back discomfort. Non-invasive interventions like bracing proved ineffective, leading to the progression of the spinal curvature. After the surgical procedure, diagnostic imaging displayed a marked enhancement across all three spatial dimensions. After a postoperative physical assessment, it was noted that the patient experienced significant enhancements in shoulder alignment and rib hump prominence, with no discernible neurological or other adverse effects. : Surgical intervention is considered the optimal approach for addressing such congenital anomalies. Typically, timely surgical intervention leads to favorable results and has the potential to halt the advancement of deformity and curvature enlargement.
Topics: Humans; Kyphosis; Female; Adolescent; Thoracic Vertebrae; Treatment Outcome; Scoliosis
PubMed: 38929517
DOI: 10.3390/medicina60060897 -
Medicina (Kaunas, Lithuania) May 2024Muscle properties are critical for performance and injury risk, with changes occurring due to physical exertion, aging, and neurological conditions. The MyotonPro... (Review)
Review
Muscle properties are critical for performance and injury risk, with changes occurring due to physical exertion, aging, and neurological conditions. The MyotonPro device offers a non-invasive method to comprehensively assess muscle biomechanical properties. This systematic review evaluates the reliability of MyotonPro across various muscles for diagnostic purposes. Following PRISMA guidelines, a comprehensive literature search was conducted in Medline (PubMed), Ovid (Med), Epistemonikos, Embase, Cochrane Library, Clinical trials.gov, and the WHO International Clinical Trials platform. Studies assessing the reliability of MyotonPro across different muscles were included. A methodological quality assessment was performed using established tools, and reviewers independently conducted data extraction. Statistical analysis involved summarizing intra-rater and inter-rater reliability measures across muscles. A total of 48 studies assessing 31 muscles were included in the systematic review. The intra-rater and inter-rater reliability were consistently high for parameters such as frequency and stiffness in muscles of the lower and upper extremities, as well as other muscle groups. Despite methodological heterogeneity and limited data on specific parameters, MyotonPro demonstrated promising reliability for diagnostic purposes across diverse patient populations. The findings suggest the potential of MyotonPro in clinical assessments for accurate diagnosis, treatment planning, and monitoring of muscle properties. Further research is needed to address limitations and enhance the applicability of MyotonPro in clinical practice. Reliable muscle assessments are crucial for optimizing treatment outcomes and improving patient care in various healthcare settings.
Topics: Humans; Reproducibility of Results; Muscle, Skeletal; Diagnostic Tests, Routine
PubMed: 38929468
DOI: 10.3390/medicina60060851 -
International Journal of Molecular... Jun 2024Haemoglobin disorders represent a heterogeneous group of inherited conditions that involve at least one genetic abnormality in one or more of the globin chains,... (Review)
Review
Haemoglobin disorders represent a heterogeneous group of inherited conditions that involve at least one genetic abnormality in one or more of the globin chains, resulting in changes in the structure, function, and/or amount of haemoglobin molecules, which are very important for their related clinical aspects. Detecting and characterizing these disorders depends primarily on laboratory methods that employ traditional approaches and, when necessary, newer methodologies essential for solving a number of diagnostic challenges. This review provides an overview of key laboratory techniques in the diagnosis of haemoglobinopathies, focusing on the challenges, advancements, and future directions in this field. Moreover, many haemoglobinopathies are benign and clinically silent, but it is not uncommon to find unexpected variants during routine laboratory tests. The present work reported a rare and clinically interesting case of identification of haemoglobin fractions in an adult man by the determination of glycated haemoglobin (HbA) during a routine laboratory assessment, highlighting how the correct use of laboratory data can modify and improve the patient's clinical management.
Topics: Humans; Hemoglobinopathies; Molecular Diagnostic Techniques; Hemoglobins; Male; Glycated Hemoglobin; Hemoglobins, Abnormal
PubMed: 38928486
DOI: 10.3390/ijms25126781 -
Health and Quality of Life Outcomes Jun 2024Colonoscopy is a valuable diagnostic tool but the procedure and the preparation for it cause anxiety and discomfort that impacts on patients' health-related quality of...
BACKGROUND
Colonoscopy is a valuable diagnostic tool but the procedure and the preparation for it cause anxiety and discomfort that impacts on patients' health-related quality of life (HRQoL). The 'disutility' of undergoing an invasive colonoscopy needs to be considered and accounted for in comprehensive cost-utility analyses that compare different diagnostic strategies, yet there is little empirical evidence that can be used in such studies. To fill this gap, we collected and analysed data on the effect of a colonoscopy examination on patients' HRQoL that can be used in economic evaluations.
METHODS
Patients scheduled to undergo a colonoscopy at a large NHS hospital were asked to complete the EuroQol EQ-5D-5 L instrument: (i) before the procedure, at the time of consent (T1), (ii) while undergoing bowel preparation (T2) and (iii) within 24 h after the procedure (T3). Complete responses were translated into preference-based HRQoL (utility) values using a UK-specific value set and were analysed using descriptive and inferential statistical analyses.
RESULTS
Two-hundred and seventy-one patients with gastrointestinal symptoms referred for a colonoscopy provided complete EQ-5D-5 L questionnaires at all three assessment points. At T1, the mean EQ-5D-5 L value was 0.76 (95%CI: 0.734-0.786). This value dropped to 0.727 at T2 (95%CI: 0.7-0.754, before increasing again to 0.794 (95%CI: 0.768-0.819) at T3. Both changes were statistically significant (p-value < 0.001).
CONCLUSIONS
Preference-based HRQoL (utility) values reported by patients undergoing a colonoscopy dropped during bowel preparation and rose again shortly after the colonoscopy. This pattern was largely consistent across patients with different characteristics, symptoms and diagnoses.
Topics: Humans; Colonoscopy; Quality of Life; Female; Male; Middle Aged; Surveys and Questionnaires; Aged; United Kingdom; Adult; Cost-Benefit Analysis
PubMed: 38926801
DOI: 10.1186/s12955-024-02262-x -
Scientific Reports Jun 2024Medial displacement calcaneal osteotomy (MDCO) is the standard procedure for flatfoot. We investigated the effect of MDCO on the foot using a finite element analysis....
Medial displacement calcaneal osteotomy (MDCO) is the standard procedure for flatfoot. We investigated the effect of MDCO on the foot using a finite element analysis. Foot models were created from computed tomography data of 8 patients with flat feet. MDCO was performed on each model with bone translation distance of 4, 8, and 12 mm. The morphological changes, plantar pressures, and stress percentage on the talocrural and subtalar joints were evaluated before and after surgery. Morphological evaluation showed improvement in the medial longitudinal arch. The stress percentage of plantar pressure in the medial area decreased, and the stress percentage of plantar pressure in the mid- and lateral forefoot area increased. At the talocrural joint, the medial and middle stress percentage increased, while the lateral and posterior stress percentage decreased. In the subtalar joint, the stress percentage in the middle subtalar joint increased and that in the posterior subtalar joint decreased. Within the posterior subtalar joint, the anterior and medial stress percentage increased, while the posterior and lateral stress percentage decreased. Preoperative simulation using the finite element analysis may be useful in understanding postoperative morphological changes and loading conditions to perform patient-specific surgery.
Topics: Humans; Flatfoot; Finite Element Analysis; Osteotomy; Male; Female; Calcaneus; Adult; Tomography, X-Ray Computed; Stress, Mechanical; Young Adult; Subtalar Joint; Weight-Bearing; Biomechanical Phenomena; Middle Aged
PubMed: 38926451
DOI: 10.1038/s41598-024-65565-5 -
Nihon Hoshasen Gijutsu Gakkai Zasshi Jun 2024We evaluated the measurement accuracy of the CubeScan BioCon-900 (here after BioCon-900), a portable ultrasound imaging diagnostic device capable of measuring bladder...
PURPOSE
We evaluated the measurement accuracy of the CubeScan BioCon-900 (here after BioCon-900), a portable ultrasound imaging diagnostic device capable of measuring bladder volume, to determine if it can accurately assess bladder volume before intensity-modulated radiation therapy (IMRT) for prostate cancer.
METHODS
Bladder volume was measured from kV-Cone Beam computed tomography (CBCT) images obtained immediately before the administration of IMRT for prostate cancer using Halcyon. The bladder volume measured from kV-CBCT images (23 patients, total number of scans: 139) immediately before the IMRT procedure was used as the reference value. The difference between the bladder volume measured by the BioCon-900 was then calculated.
RESULTS
The bladder volume measured from kV-CBCT images was 117.5±49.4 cc. In contrast, the bladder volume obtained with BioCon-900 was 104.1±48.6 ml, resulting in an absolute mean difference of 18.4% and a correlation coefficient of 0.881. The measurements by BioCon-900 tended to be, on average, 11% smaller than the bladder volume measured by kV-CBCT imaging.
CONCLUSION
kV-CBCT images demonstrated a strong positive correlation between bladder volume and bladder urine output obtained with BioCon-900. BioCon-900 can be used before kV-CBCT imaging to accurately and conveniently assess bladder volume.
PubMed: 38925920
DOI: 10.6009/jjrt.2024-1461 -
Science Advances Jun 2024Lip language recognition urgently needs wearable and easy-to-use interfaces for interference-free and high-fidelity lip-reading acquisition and to develop accompanying...
Lip language recognition urgently needs wearable and easy-to-use interfaces for interference-free and high-fidelity lip-reading acquisition and to develop accompanying data-efficient decoder-modeling methods. Existing solutions suffer from unreliable lip reading, are data hungry, and exhibit poor generalization. Here, we propose a wearable lip language decoding technology that enables interference-free and high-fidelity acquisition of lip movements and data-efficient recognition of fluent lip language based on wearable motion capture and continuous lip speech movement reconstruction. The method allows us to artificially generate any wanted continuous speech datasets from a very limited corpus of word samples from users. By using these artificial datasets to train the decoder, we achieve an average accuracy of 92.0% across individuals ( = 7) for actual continuous and fluent lip speech recognition for 93 English sentences, even observing no training burn on users because all training datasets are artificially generated. Our method greatly minimizes users' training/learning load and presents a data-efficient and easy-to-use paradigm for lip language recognition.
Topics: Humans; Wearable Electronic Devices; Speech; Language; Lip; Movement; Male; Female; Adult; Lipreading; Motion Capture
PubMed: 38924408
DOI: 10.1126/sciadv.ado9576