Gynecology and Minimally Invasive... 2024Vulvar intestinal adenocarcinoma is a rare malignancy. The most significant predictor of advanced vulvar cancer is achieving complete resection, although determining the...
Vulvar intestinal adenocarcinoma is a rare malignancy. The most significant predictor of advanced vulvar cancer is achieving complete resection, although determining the optimal treatment for this rare histologic type remains uncertain. We report the case of a 63-year-old woman with a primary vulvar tumor suspected of having rectal invasion and inguinal lymph node metastases based on preoperative magnetic resonance imaging and computed tomography scans. To achieve complete resection of stage IIIC intestinal-type vulvar adenocarcinoma, we performed a laparoscopic posterior pelvic exenteration (PPE) and radical vulvectomy, along with bilateral inguinal lymph node dissection. This case report highlights the use of a novel hybrid procedure that combines laparoscopic PPE with radical vulvectomy and bilateral inguinal lymph node dissection for vulvar adenocarcinoma of the intestinal type. Laparoscopic PPE can be considered a minimally invasive approach for vulvar tumor when complete resection is achievable with an appropriate safety margin.
PubMed: 38911313
DOI: 10.4103/gmit.gmit_103_23 -
Veterinary World May 2024African swine fever (ASF) is a highly virulent and contagious viral disease caused by the ASF virus (ASFV). It has a significant impact on swine production throughout...
BACKGROUND AND AIM
African swine fever (ASF) is a highly virulent and contagious viral disease caused by the ASF virus (ASFV). It has a significant impact on swine production throughout the world, while existing vaccines and specific treatments remain ineffective. ASFV p30 is a potent antigenic protein that induces protective antibodies immediately after infection; however, most recombinant p30 is insoluble. This study aimed to improve the solubility, yield, and purity of recombinant p30 by tagging it with a small ubiquitin-like modifier (SUMO) and modifying the protein purification process.
MATERIALS AND METHODS
SUMO fused with ASFV p30 (SUMO-p30) and p30 alone were cloned and expressed in . SUMO-p30 and p30 solubility and expression levels were analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Protein purification was modified by combining ammonium sulfate precipitation method with affinity chromatography. In addition, large-scale production of all versions of p30 were compared using SDS-PAGE and western blotting, and the purified p30 was used to develop the indirect enzyme-linked immunosorbent assay (ELISA).
RESULTS
The solubility and expression levels of SUMO-p30 were dramatically enhanced compared with that of p30. Modification of the purification process significantly increased purified and soluble SUMO-p30 and p30 yields by 6.59 and 1.02 μg/mL, respectively. Large-scale production confirmed that this procedure increased the quantity of recombinant p30 while maintaining protein purity and immunogenicity. The p30-based indirect ELISA was able to discriminate between positive and negative serum samples with statistically significant differences in mean optical density 450 values (p < 0.001).
CONCLUSION
This study demonstrates the enhancement of solubility, purity, and yield of ASFV p30 expressed in by SUMO fusion tagging and combining ammonium sulfate precipitation with affinity chromatography for protein purification. These positive effects were sustained in large-scale production. Cleavage and removal of hexahistidine-SUMO tag from the fusion protein by protease may not be suitable when handling a large amount of the protein. However, the SUMO-fused p30 retained strong immunoreactivity to convalescent swine serum, indicating its application in immunization and diagnostic purposes. The expression and purification procedures in this study could be applied to increase solubility, quality, and quantity of other recombinant proteins as well.
PubMed: 38911078
DOI: 10.14202/vetworld.2024.1157-1167 -
Cureus May 2024Background A major development in noninvasive imaging modalities, computed tomographic enterography (CTE) has a number of benefits over conventional computed tomography...
Background A major development in noninvasive imaging modalities, computed tomographic enterography (CTE) has a number of benefits over conventional computed tomography (CT) and capsule endoscopy. Through the utilization of multidetector computed tomography (MDCT) technology, CTE expedites the assessment of small bowel diseases, especially in those segments that are not accessible through traditional endoscopy. This study's main goal is to thoroughly evaluate CTE's diagnostic accuracy for a range of small intestinal conditions. Methodology In this investigation, which is a prospective observational study, 40 patients, 25 men and 15 women, with suspected small intestinal disorders and ages ranging from 10 to 70 underwent CTE. To evaluate diagnosis accuracy, a combination of clinical symptoms, imaging data, and histopathological/ultrasonography findings were evaluated. Throughout the research procedure, ethical issues and statistical analysis were incorporated to guarantee validity and adherence to ethical norms. Results The most frequent findings on CTE were bowel thickening and mucosal hyperenhancement, which were seen in 25 (62.5%) and 20 (50%) of the patients, respectively. The majority of patients (65%) exhibited both the ileal and jejunal loops to be adequately distended in grade III. In 35% of the patients, grade II distensibility of the ileal and jejunal loops was seen. Conclusion When it comes to accurately detecting small intestinal disorders, CTE is superior. It evaluates extraintestinal, mural, and intraluminal diseases with efficacy, particularly in places that are difficult to reach. It is essential for directing clinical decisions because of its capacity to assess disease activity prior to endoscopy and see consequences.
PubMed: 38910779
DOI: 10.7759/cureus.60915 -
Journal of Cardiothoracic Surgery Jun 2024Cor triatriatum sinister (CTS) is an uncommon congenital cardiac anomaly. Atrial fibrillation (AF) is commonly the initial symptom in patients with CTS, occurring in...
Exploring new frontiers: a rare case of catheter ablation for persistent atrial fibrillation in a patient with cor triatriatum sinister guided by intracardiac echocardiography.
BACKGROUND
Cor triatriatum sinister (CTS) is an uncommon congenital cardiac anomaly. Atrial fibrillation (AF) is commonly the initial symptom in patients with CTS, occurring in approximately 32% of the cases. The complexity of performing AF catheter ablation, particularly in cases with persistent AF, increases in patients with CTS due to its unique structural challenges.
CASE PRESENTATION
We report the treatment course of a 60-year-old male patient diagnosed with CTS, who underwent catheter ablation of drug-refractory, persistent AF. The complex anatomical structure of the condition made catheter ablation of AF challenging. To navigate these challenges, we performed comprehensive assessments using transthoracic echocardiography and transesophageal echocardiography, along with cardiac computed tomography angiography, prior to treatment initiation. The intricate anatomy of CTS was further clarified during the procedure via intracardiac echocardiography (ICE). Additionally, the complexity of catheter manipulation was further reduced with the aid of the VIZIGO sheath and the vein of Marshall ethanol infusion to achieve effective mitral isthmus blockage, thereby circumventing the impact of the CTS membrane.
CONCLUSIONS
This case underscores the complexity and potential of advanced ablation techniques in managing cardiac arrhythmias associated with unusual cardiac anatomies. During the procedure, ICE facilitated detailed modeling of the left atrium, including the membranous structure and its openings, thus providing a clearer understanding of CTS. It is noteworthy that the membrane within the CTS may serve as a potential substrate for arrhythmias, which warrants further validation through larger sample studies.
Topics: Humans; Cor Triatriatum; Male; Atrial Fibrillation; Middle Aged; Catheter Ablation; Echocardiography, Transesophageal; Echocardiography
PubMed: 38909226
DOI: 10.1186/s13019-024-02859-9 -
Medicina 2024Ewing sarcoma (ES) and primitive neuroectodermal tumor (PNET) belong to the group of neoplasms called small round cell tumors. PNETs have been divided into central and...
Ewing sarcoma (ES) and primitive neuroectodermal tumor (PNET) belong to the group of neoplasms called small round cell tumors. PNETs have been divided into central and peripheral. ES and peripheral PNETs arise from bones, soft tissues, or peripheral nerves. We present a case of hepatic ES/PNET in a healthy man that began four months before consultation with abdominal symptoms and weight loss. Upper gastrointestinal endoscopy and laboratory tests revealed no notable findings. The abdominal tomography revealed an enlarged liver due to a solid lesion that involved all its segments with intravenous contrast enhancement and large areas of necrosis. It compressed and displaced neighboring structures. Core needle biopsy of the liver lesion was performed: small round cell neoplasm. Immunohistochemistry revealed negativity for CD45, CKA1/A3, chromogranin, synaptophysin, and cytokeratins CK7 and CK20. Dim CD56 expression and CD99, FLI-1, and NKX2 positivity. He underwent chemotherapy treatment with carboplatin and etoposide for 6 cycles with clinical improvement and tolerance. Control images showed reduction of the mass with involvement of the right hepatic lobe, involvement of the inferior vena cava, infiltration of the right adrenal gland and upper pole of the right kidney. He was referred to hepatobiliary surgery for surgical resection of the residual lesion. The patient rejected the proposed surgical procedure. Our objective is to highlight the clinical and histological diagnostic challenge of this entity that requires ruling out other clinical entities.
Topics: Humans; Male; Liver Neoplasms; Sarcoma, Ewing; Tomography, X-Ray Computed; Immunohistochemistry; Adult; Neuroectodermal Tumors, Primitive, Peripheral
PubMed: 38907976
DOI: No ID Found -
Medicina 2024To compare the diagnostic sensitivity of artificial intelligence (AI) assisted videocolposcopy with standard videocolposcopy performed by specialist colposcopists. (Comparative Study)
Comparative Study
INTRODUCTION
To compare the diagnostic sensitivity of artificial intelligence (AI) assisted videocolposcopy with standard videocolposcopy performed by specialist colposcopists.
METHODS
A descriptive retrospective cross-sectional study, 782 anonymized medical records from the Computerized System for Screening (SITAM) of women who underwent videocolposcopy with AI and colposcopy with common videocolposcopy performed by specialists, with their corresponding biopsies (gold standard) were analyzed. The relationship between the results of IA videocolposcopy and regular videocolposcopy and the results of biopsies was evaluated. The overall accuracy of each diagnostic procedure was calculated. The sensitivity and concordance of the results of AI videocolposcopy with the gold standard (biopsy) were determined.
RESULTS
A total of 395 patient records of patients with IA videocolposcopy and 387 with regular videocolposcopy were analyzed. The accuracy of results was 80% (IC 95%: 75-83%) in IA videocolposcopy and 65% (IC 95%: 60-69%) in regular videocolposcopy (p<0.001). Videocolposcopy results with IA and common colposcopy were significantly correlated with biopsy results, rs=0.75 vs. rs=0.57 respectively (p<0.001). The sensitivity of videocolposcopy with AI was 96% (95% CI: 94-98%), and 93% (95% CI: 89-95%) for regular colposcopy. The overall agreement of colposcopic impressions classified by videocolposcopy with AI and disease was higher than that of colposcopic interpretation by colposcopists (90% vs. 83%, Kappa 0.59 vs. 0.47, p<0.001).
CONCLUSION
The high diagnostic accuracy of AI videocolposcopy allows obtaining highly sensitive studies that help in the early detection of precursor lesions of cervical neoplasia.
Topics: Humans; Female; Artificial Intelligence; Cross-Sectional Studies; Retrospective Studies; Colposcopy; Uterine Cervical Neoplasms; Sensitivity and Specificity; Adult; Precancerous Conditions; Middle Aged; Biopsy; Uterine Cervical Dysplasia; Video Recording; Cervix Uteri; Reproducibility of Results
PubMed: 38907959
DOI: No ID Found -
BMC Health Services Research Jun 2024Among the various methods used, administrative data collected for claims and billing purposes, such as diagnosis codes and present-on-admission (POA) indicators, can...
Accuracy assessment of patient safety incident (PSI) codes and present-on-admission (POA) indicators: a cross-sectional analysis using the Patient Safety Incidents Inquiry (PSII) in Korea.
BACKGROUND
Among the various methods used, administrative data collected for claims and billing purposes, such as diagnosis codes and present-on-admission (POA) indicators, can easily be employed to assess patient safety status. However, it is crucial that administrative data be accurate to generate valid estimates of adverse event (AE) occurrence. Thus, we aimed to evaluate the accuracy of diagnosis codes and POA indicators in patients with confirmed AEs in the hospital admission setting.
METHODS
We analysed the diagnosis codes of 1,032 confirmed AE cases and 6,754 non-AE cases from the 2019 Patient Safety Incidents Inquiry, which was designed as a cross-sectional study, to determine their alignment with the Korean Patient Safety Incidents (PSIs) Code Classification System. The unit of analysis was the individual case rather than the patient, because two or more AEs may occur in one patient. We examined whether the primary and secondary diagnostic codes had PSIs codes matching the AE type and checked each PSI code for whether the POA indicator had an 'N' tag. We reviewed the presence of PSI codes in patients without identified AEs and calculated the correlation between the AE incidence rate and PSI code and POA indicator accuracy across 15 hospitals.
RESULTS
Ninety (8.7%) of the AE cases had PSI codes with an 'N' tag on the POA indicator compared to 294 (4.4%) of the non-AE cases. Infection- (20.4%) and surgery/procedure-related AEs (13.6%) had relatively higher instances of correctly tagged PSI codes. We did not identify any PSI codes for diagnosis-related incidents. While we noted significant differences in AE incidence rates, PSI code accuracy, and POA indicator accuracy among the hospitals, the correlations between these variables were not statistically significant.
CONCLUSION
Currently, PSI codes and POA indicators in South Korea appear to have low validity. To use administrative data in medical quality improvement activities such as monitoring patient safety levels, improving the accuracy of administrative data should be a priority. Possible strategies include targeted education on PSI codes and POA indicators and introduction of new evaluation indicators regarding the accuracy of administrative data.
Topics: Humans; Cross-Sectional Studies; Republic of Korea; Patient Safety; Medical Errors; Quality Indicators, Health Care; Male; Female
PubMed: 38907291
DOI: 10.1186/s12913-024-11210-w -
RoFo : Fortschritte Auf Dem Gebiete Der... Jun 2024Axillary lymphadenopathy (LA) after COVID-19 vaccination is now known to be a common side effect. In these cases, malignancy cannot always be excluded on the basis of...
Axillary lymphadenopathy (LA) after COVID-19 vaccination is now known to be a common side effect. In these cases, malignancy cannot always be excluded on the basis of morphological imaging criteria.Narrative review for decision-making regarding control and follow-up intervals for axillary LA according to currently published research. This article provides a practical overview of the management of vaccine-associated LA using image examples and a flowchart and provides recommendations for follow-up intervals. A particular focus is on patients presenting for diagnostic breast imaging. The diagnostic criteria for pathological lymph nodes (LN) are explained.Axillary LA is a common adverse effect after COVID-19 vaccination (0.3-53%). The average duration of LA is more than 100 days. LA is also known to occur after other vaccinations, such as the seasonal influenza vaccine. Systematic studies on this topic are missing. Other causes of LA after vaccination (infections, autoimmune diseases, malignancies) should be considered for the differential diagnosis. If the LA persists for more than 3 months after COVID-19 vaccination, a primarily sonographic follow-up examination is recommended after another 3 months. A minimally invasive biopsy of the LA is recommended if a clinically suspicious LN persists or progresses. In the case of histologically confirmed breast cancer, a core biopsy without a follow-up interval is recommended regardless of the vaccination, as treatment appropriate to the stage should not be influenced by follow-up intervals. For follow-up after breast cancer, the procedure depends on the duration of the LA and the woman's individual risk of recurrence.Vaccination history should be well documented and taken into account when evaluating suspicious LN. Biopsy of abnormal, persistent, or progressive LNs is recommended. Preoperative staging of breast cancer should not be delayed by follow-up. The risk of false-positive findings is accepted, and the suspicious LNs are histologically examined in a minimally invasive procedure. · The vaccination history must be documented (vaccine, date, place of application).. · If axillary LA persists for more than 3 months after vaccination, a sonographic follow-up examination is recommended after 3 months.. · Enlarged LNs that are persistent, progressive in size, or are suspicious on control sonography should be biopsied.. · Suspicious LNs should be clarified before starting oncological therapy, irrespective of the vaccination status, according to the guidelines and without delaying therapy.. · Wilpert C, Wenkel E, Baltzer PA et al. Vaccine-associated axillary lymphadenopathy with a focus on COVID-19 vaccines. Fortschr Röntgenstr 2024; DOI 10.1055/a-2328-7536.
PubMed: 38906159
DOI: 10.1055/a-2328-7536 -
PloS One 2024In a clinical context, conventional optical microscopy is commonly used for the visualization of biological samples for diagnosis. However, the availability of molecular...
In a clinical context, conventional optical microscopy is commonly used for the visualization of biological samples for diagnosis. However, the availability of molecular techniques and rapid diagnostic tests are reducing the use of conventional microscopy, and consequently the number of experienced professionals starts to decrease. Moreover, the continuous visualization during long periods of time through an optical microscope could affect the final diagnosis results due to induced human errors and fatigue. Therefore, microscopy automation is a challenge to be achieved and address this problem. The aim of the study is to develop a low-cost automated system for the visualization of microbiological/parasitological samples by using a conventional optical microscope, and specially designed for its implementation in resource-poor settings laboratories. A 3D-prototype to automate the majority of conventional optical microscopes was designed. Pieces were built with 3D-printing technology and polylactic acid biodegradable material with Tinkercad/Ultimaker Cura 5.1 slicing softwares. The system's components were divided into three subgroups: microscope stage pieces, storage/autofocus-pieces, and smartphone pieces. The prototype is based on servo motors, controlled by Arduino open-source electronic platform, to emulate the X-Y and auto-focus (Z) movements of the microscope. An average time of 27.00 ± 2.58 seconds is required to auto-focus a single FoV. Auto-focus evaluation demonstrates a mean average maximum Laplacian value of 11.83 with tested images. The whole automation process is controlled by a smartphone device, which is responsible for acquiring images for further diagnosis via convolutional neural networks. The prototype is specially designed for resource-poor settings, where microscopy diagnosis is still a routine process. The coalescence between convolutional neural network predictive models and the automation of the movements of a conventional optical microscope confer the system a wide range of image-based diagnosis applications. The accessibility of the system could help improve diagnostics and provide new tools to laboratories worldwide.
Topics: Microscopy; Humans; Printing, Three-Dimensional; Software; Robotics; Smartphone; Automation; Imaging, Three-Dimensional
PubMed: 38905190
DOI: 10.1371/journal.pone.0304085 -
International Journal of Medical... 2024The Sodium-glucose co-transporter 2 (SGLT2) inhibitor is an anti-glycemic agent that frequently used in type 2 diabetes mellitus (T2DM) with antioxidant effects....
The lower incidence of endometrial cancer after sodium-glucose cotransporter 2 inhibitors administration in type 2 diabetes mellitus population: a nationwide cohort study.
The Sodium-glucose co-transporter 2 (SGLT2) inhibitor is an anti-glycemic agent that frequently used in type 2 diabetes mellitus (T2DM) with antioxidant effects. Endometrial cancer (EC) is a common gynecological malignancy that correlates with oxidative stress. The aim in the present study is to survey the potential association between the SGLT2 inhibitor administration and the incidence of EC by the application of the National Health Insurance Research Database (NHIRD) of Taiwan. A retrospective cohort study was directed and the T2DM participants were divided into the SGLT2 inhibitors users and non-SGLT2 inhibitors users. After matching, a total of 163,668 and 327,336 participants were included into the SGLT2 inhibitors and control groups, respectively. The primary outcome is regarded as the development of EC according to the diagnostic, image, and procedure codes. Cox proportional hazard regression was employed to generate the adjusted hazard ratio (aHR) and 95% confidence interval (CI) of EC between the two groups. There were 422 and 876 EC events observed in the SGLT2 inhibitors and control groups, respectively. The SGLT2 inhibitors group demonstrated a significantly lower incidence of EC formation compared to the control groups (aHR: 0.87, 95% CI: 0.76-0.99). In the subgroup analysis, the correlation between SGLT2 inhibitor administration and lower rate of EC existed in the T2DM individuals with aged under 60. Moreover, the association between SGLT2 inhibitor administration and lower EC incidence only presented in the T2DM population with SGLT2 inhibitor administration under one year (aHR: 0.58, 95% CI: 0.45-0.73). In conclusion, the administration of SGLT2 inhibitors correlates to lower incidence of EC in T2DM population.
Topics: Humans; Female; Sodium-Glucose Transporter 2 Inhibitors; Diabetes Mellitus, Type 2; Endometrial Neoplasms; Middle Aged; Incidence; Taiwan; Retrospective Studies; Aged; Adult
PubMed: 38903923
DOI: 10.7150/ijms.95584