Frontiers in Microbiology 2024This study aimed to explore whether G423 could improve growth performance and lipid metabolism of broilers by the modulation of gut microbiota and metabolites. A total...
This study aimed to explore whether G423 could improve growth performance and lipid metabolism of broilers by the modulation of gut microbiota and metabolites. A total of 640 1-day-old AA broilers were randomly divided into 4 groups [Control (CON), Lac_L, Lac_H, and ABX]. Average daily gain (ADG), average daily feed intake (ADFI), feed conversion ratio (FCR), breast muscle, thigh muscle, and abdominal fat pad were removed and weighed at 42 days of age. Serum was obtained by centrifuging blood sample from jugular vein (10 mL) for determining high-density lipoprotein (HDL), total cholesterol (TC), low-density lipoprotein (LDL), and triglyceride (TG) using ELISA. The ileal contents were harvested and immediately frozen in liquid nitrogen for 16S rRNA and LC-MS analyses. Then, the results of 16S rRNA analysis were confirmed by quantitative polymerase chain reaction (qPCR). Compared with the CON group, FCR significantly decreased in the Lac_H group ( < 0.05) in 1-21 days; ADG significantly increased and FCR significantly decreased in the Lac_H group ( < 0.05) in 22-42 days. 42 days weight body and ADG significantly increased in the Lac_H group ( < 0.05) in 42 days. Abdominal fat percentage was significantly decreased by G423 ( < 0.05), the high dose of G423 significantly decreased the serum of TG, TC, and LDL level ( < 0.05), and the low dose of G423 significantly decreased the serum of TG and TC level ( < 0.05). A significant difference in microbial diversity was found among the four groups. Compared with the CON group, the abundance rates of in the Lac_H group were significantly increased ( 0.05). The global and overview maps and membrane transport in the Lac_L, Lac_H, and ABX groups significantly changed versus those in the CON group ( < 0.05). The results of LC-MS demonstrated that could significantly improve the levels of some metabolites (6-hydroxy-5-methoxyindole glucuronide, 9,10-DiHOME, -Acetyl-l-phenylalanine, and kynurenine), and these metabolites were involved in four metabolic pathways. Among them, the pathways of linoleic acid metabolism, phenylalanine metabolism, and pentose and glucuronate interconversions significantly changed ( < 0.05). G423 could ameliorate growth performance and lipid metabolism of broilers by the modulation of gut microbiota and metabolites.
PubMed: 38939183
DOI: 10.3389/fmicb.2024.1381756 -
JACC. Advances Nov 2023Surgery for isolated functional tricuspid regurgitation (TR) poses a high risk. Several transcatheter approaches are being evaluated for the treatment of such patients....
BACKGROUND
Surgery for isolated functional tricuspid regurgitation (TR) poses a high risk. Several transcatheter approaches are being evaluated for the treatment of such patients. The K-Clip system is a percutaneous approach designed for functional TR; however, its utility remains unknown.
OBJECTIVES
This study aimed to report the 30-day echocardiographic and clinical outcomes with the K-Clip system for severe TR, including changes in TR severity and NYHA functional class.
METHODS
Transcatheter tricuspid valve annuloplasty was performed in 39 patients with intermediate or high surgical risk who underwent the K-Clip system. The right internal jugular vein procedure was performed with annuloplasty guided by fluoroscopy and echocardiography. The primary outcomes were clinical success and all-cause mortality at the 30-day follow-up.
RESULTS
The K-Clip was successfully implanted in all cases, with 1 to 3 devices deployed. At the 30-day follow-up, none of the patients had died. TR severity was reduced by at least one grade in all patients. There were no severe procedural or 30-day adverse events, except for 1 new pacemaker implantation. The proportion of NYHA class III-IV patients decreased from 79.5% to 5.1%, and the ascites disappeared. The 6-minute walk distance increased by 78 m ( < 0.05), and the Kansas City Cardiomyopathy Questionnaire score improved by 11 points ( < 0.05).
CONCLUSIONS
The K-Clip device is practical, safe, and effective for patients with severe TR. A 30-day reduction in TR and enhanced cardiac function and quality of life were associated with transcatheter tricuspid annuloplasty using the K-Clip device, according to short-term follow-up studies. (Confirmatory Clinical Study of Treating Tricuspid Regurgitation With K-Clip TM Transcatheter Annuloplasty System [TriStar]; NCT05173233).
PubMed: 38938712
DOI: 10.1016/j.jacadv.2023.100671 -
Journal of Clinical Medicine Jun 2024Tunneled central venous catheters are commonly used for dialysis in patients without a functional permanent vascular access. In an emergent setting, a non-tunneled,...
Tunneled central venous catheters are commonly used for dialysis in patients without a functional permanent vascular access. In an emergent setting, a non-tunneled, temporary central venous catheter is often placed for immediate dialysis. The most critical step in the catheter insertion is venipuncture, which is often a major cause for longer intervention times and procedure-related adverse events. To avoid this critical step when placing a more permanent tunneled catheter, an exchange over a previously placed temporary one can be considered. In this paper, we present a modified switching approach with a separate access site. : In this retrospective analysis of a prospective database, we examined whether this modified technique is non-inferior to a de novo application. Therefore, we included all 396 patients who received their first tunneled dialysis catheter at our site from March 2018 to March 2023. Out of these, 143 patients received the modified approach and 253 the standard de novo ultrasound-guided puncture and insertion. Then, the outcomes of the two groups, including adverse events and infections, were compared by nonparametric tests and multivariable logistic regression. In both groups, the implantations were 100% successful. Catheter explantation due to infection according to CDC criteria was necessary in 18 cases, with no difference between the groups (5.0% vs. 4.4% = 0.80). The infection rate per 100 days was 0.113 vs. 0.106 in the control group, with a comparable spectrum of bacteria. A total of 12 catheters (3 vs. 9) had to be removed due to a periinterventional complication. An early-onset infection was the reason in two cases (1.3%) in the study group and five in the control group (1.9%). A total misplacement of the catheter occurred in two cases only in the control group. After adjustment for potential confounders via multivariable logistic regression there was not a significant difference in the complication rate (adjusted odds ratio, aOR = 0.53, 95% CI = 0.14-2.03, = 0.351) but an estimated decreased risk overall based on the average treatment effect of -1.7% in favor of the study group. The present study shows that a catheter exchange leads to no more infections than a de novo placement; hence, it is a feasible method. Moreover, misplacements and control chest X-rays to exclude pneumothorax after venipuncture were completely avoided by exchanging. This approach yields a much lower infection rate than previous reports: 1.3% compared to 2.7% in all existing aggregated studies. The presented approach seems to be superior to existing switching methods. Overall, an exchange can also help to preserve veins for future access, since the same jugular vein is used.
PubMed: 38929895
DOI: 10.3390/jcm13123367 -
Biomedicines Jun 2024Autologous vein grafts are widely used for bypass procedures in cardiovascular surgery. However, these grafts are susceptible to failure due to vein graft disease. Our...
BACKGROUND
Autologous vein grafts are widely used for bypass procedures in cardiovascular surgery. However, these grafts are susceptible to failure due to vein graft disease. Our study aimed to evaluate the impact of the latest-generation FRAME external support on vein graft remodeling in a preclinical model.
METHODS
We performed autologous internal jugular vein interposition grafting in porcine carotid arteries for one month. Four grafts were supported with a FRAME mesh, while seven unsupported grafts served as controls. The conduits were examined through flowmetry, angiography, macroscopy, and microscopy.
RESULTS
The one-month patency rate of FRAME-supported grafts was 100% (4/4), whereas that of unsupported controls was 43% (3/7, Log-rank = 0.071). On explant angiography, FRAME grafts exhibited significantly more areas with no or mild stenosis (9/12) compared to control grafts (3/21, = 0.0009). Blood flow at explantation was higher in the FRAME grafts (145 ± 51 mL/min) than in the controls (46 ± 85 mL/min, = 0.066). Area and thickness of neo-intimal hyperplasia (NIH) at proximal anastomoses were similar for the FRAME and the control groups: 5.79 ± 1.38 versus 6.94 ± 1.10 mm, respectively ( = 0.558) and 480 ± 95 vs. 587 ± 52 μm/μm, respectively ( = 0.401). However, in the midgraft portions, the NIH area and thickness were significantly lower in the FRAME group than in the control group: 3.73 ± 0.64 vs. 6.27 ± 0.64 mm, respectively ( = 0.022) and 258 ± 49 vs. 518 ± 36 μm/μm, respectively ( = 0.0002).
CONCLUSIONS
In our porcine model, the external mesh FRAME improved the patency of vein-to-carotid artery grafts and protected them from stenosis, particularly in the mid regions. The midgraft neo-intimal hyperplasia was two-fold thinner in the meshed grafts than in the controls.
PubMed: 38927542
DOI: 10.3390/biomedicines12061335 -
Vascular Specialist International Jun 2024Lemierre syndrome is a rare complication of oropharyngeal infection that causes septic thrombophlebitis in the internal jugular vein. Since the onset of the COVID-19...
Lemierre syndrome is a rare complication of oropharyngeal infection that causes septic thrombophlebitis in the internal jugular vein. Since the onset of the COVID-19 pandemic, this condition has been dangerously overlooked and poses an even greater threat when complicated by vascular pathologies. A case is presented where the patient required emergency endovascular exclusion of a right internal carotid artery pseudoaneurysm due to Lemierre syndrome. The treatment included stent graft placement and drainage of a neck abscess, along with appropriate antibiotic treatment during hospitalization. Recognizing this diagnosis requires a high index of suspicion, particularly during the COVID-19 pandemic. The complexity of the disease necessitates extensive multidisciplinary collaboration for effective treatment.
PubMed: 38915225
DOI: 10.5758/vsi.240025 -
Scientific Reports Jun 2024Evaluating fluid responsiveness with dynamic parameters is recommended for fluid management. However, in hemodynamically stable patients who are breathing spontaneously,...
Evaluating fluid responsiveness with dynamic parameters is recommended for fluid management. However, in hemodynamically stable patients who are breathing spontaneously, accurately measuring stroke volume variation via echocardiography and passive leg raising is challenging due to subtle SV changes. This study aimed to identify normal SV changes in healthy volunteers and evaluate the precision of hemodynamic parameters in screening mild hypovolemia in patients. This prospective, repeated-measures, cross-sectional study screened 269 subjects via echocardiography. Initially, 45 healthy volunteers underwent a fluid challenge test, the outcomes of which served as criteria to screen 215 ICU patients. Among these patients, 53 underwent additional fluid challenge testing. Hemodynamic parameters, including medians of maximum velocity time integrals (VTImaxs), peak velocity of VTImax (PV), internal jugular vein diameters (IJVD), and area (IJVA) were repeatedly measured first at a 60° upper body elevation (UBE), second in a supine position, third at UBE, fourth in a supine position, and lastly in a supine position after fluid loading. The hemodynamic responses to the position changes were compared between 83 fluid non-responders and 15 fluid responders. Fluid responsiveness was defined as fluid-induced medians' change of VTImaxs (fluid-induced median VTImax change) ≥ 10%. None of the healthy volunteers showed the mean value of repeatedly measured medians of VTImaxs ≥ 7%, following either UBE position (UBE-induced median VTImax change) or fluid loading (fluid-induced median VTImax change). UBE-induced median VTImax and PV changes were significantly correlated with fluid responsiveness (p < 0.001, AUC 0.959; p < 0.001, AUC 0.804). The significant correlations were demonstrated via multivariable analysis using binary logistic regression (p = 0.001, OR 90.1) and the correlation coefficient (R = 0.793) using linear regression analysis. UBE-induced median VTImax changes (≥ 11.8% and 7.98%) predicted fluid-induced median VTImax changes ≥ 10% and 7% (AUC 0.959 and 0.939). The collapsibility and variation of IJVD and IJVA showed no significant correlation. An increase in the mean value of medians of repeatedly measured VTImaxs transitioning from an UBE to a supine position, effectively screened mild hypovolemia and demonstrated a significant correlation with fluid responsiveness in spontaneously breathing patients maintaining hemodynamic stability.
Topics: Humans; Male; Female; Prospective Studies; Hemodynamics; Middle Aged; Fluid Therapy; Adult; Cross-Sectional Studies; Aged; Stroke Volume; Echocardiography; Respiration; Hypovolemia
PubMed: 38914634
DOI: 10.1038/s41598-024-65554-8 -
Journal of Cardiothoracic and Vascular... May 2024To test the effectiveness of a novel wire-guided scalpel (Guideblade) to create a precise dermatotomy incision for central venous catheter (CVC) insertion.
OBJECTIVE
To test the effectiveness of a novel wire-guided scalpel (Guideblade) to create a precise dermatotomy incision for central venous catheter (CVC) insertion.
DESIGN
Prospective, nonrandomized interventional study.
SETTING
Stanford University, single-center teaching hospital.
PARTICIPANTS
Cardiac and vascular surgical patients (n = 100) with planned CVC insertion for operation.
INTERVENTIONS
A wire-guided scalpel was used during CVC insertion.
RESULTS
A total of 188 CVCs were performed successfully with a wire-guided scalpel without the need for additional equipment in 100 patients, and 94% of CVCs were accomplished with only a single dermatotomy attempt. "No bleeding" or "minimal bleeding" at the insertion site was observed in 90% of patients 30 minutes after insertion and 80.7% at the conclusion of surgery.
CONCLUSION
The wire-guided scalpel was effective in performing dermatotomy for CVC with a 100% success rate and a very high first-attempt rate. The wire-guided scalpel may decrease bleeding at the CVC insertion site.
PubMed: 38908939
DOI: 10.1053/j.jvca.2024.04.003 -
Cureus Jun 2024Although central line-associated bloodstream infection (CLABSI) is the most common type of healthcare-associated infection among patients with inserted devices, few...
BACKGROUND
Although central line-associated bloodstream infection (CLABSI) is the most common type of healthcare-associated infection among patients with inserted devices, few studies have comprehensively evaluated the related risk factors.
OBJECTIVE
This retrospective study analyzed the risk factors, predictors, causative organisms, and impact of CLABSI on clinical outcomes mortality, and length of stay (LOS) in older adults.
METHODS
We included 36 patients diagnosed with CLABSI according to the Centers for Disease Control and Prevention criteria at King Abdulaziz University Hospital during 2013-2014 cases and 375 control patients controls. Risk factors were evaluated using a multivariate logistic regression analysis.
RESULTS
Cases and controls did not differ significantly in age or sex distribution. However, cases had a significantly longer LOS than controls 78 vs. 19 days, p < 0.001. One-third of 12/36 CLABSI cases were admitted to the medical intensive care unit (MICU). Most had renal disease, acute coronary syndrome, and used steroids. Additionally, 34 cases (94.4%) and 2 cases (5.6%) presented with primary and secondary infections, respectively, and hypotension was the most prevalent symptom (12/36). The internal jugular vein was the most common insertion site, and the nasogastric tube and mechanical ventilator were the most common insertion devices. Seven cases died, and three deaths were attributed to bloodstream infection (BSI). The most common cause of blood infection was , followed by .
CONCLUSIONS
The present study reveals age, LOS, total parenteral nutrition/partial parenteral nutrition (TPN/PPN), and transplantation as the independent risk factors/predictors of CLABSI.
PubMed: 38903981
DOI: 10.7759/cureus.62699 -
STAR Protocols Jun 2024In rats, cannulation of the jugular vein and the carotid artery precedes the use of the hyperinsulinemic euglycemic clamp to determine insulin sensitivity in vivo....
In rats, cannulation of the jugular vein and the carotid artery precedes the use of the hyperinsulinemic euglycemic clamp to determine insulin sensitivity in vivo. Here, we present a vascular surgery protocol to allow the infusion of substances via the vein and the collection of blood samples from the artery on the day of the hyperinsulinemic euglycemic clamp. We describe steps for preparing for and performing catheterization surgery. We then detail procedures for clamp preparation and its use. For complete details on the use and execution of this protocol, please refer to Pereira et al..
PubMed: 38900633
DOI: 10.1016/j.xpro.2024.103143 -
Polish Archives of Internal Medicine Jun 2024
PubMed: 38895975
DOI: 10.20452/pamw.16777