Molecules (Basel, Switzerland) May 2023This study describes the development and validation of a new green and high-throughput microwell spectrophotometric assay (MW-SPA) for the determination of three...
Development and Validation of Green and High-Throughput Microwell Spectrophotometric Assay for the Determination of Selective Serotonin Reuptake Inhibitors in Their Pharmaceutical Dosage Forms.
This study describes the development and validation of a new green and high-throughput microwell spectrophotometric assay (MW-SPA) for the determination of three selective serotonin reuptake inhibitors (SSRIs) in their pharmaceutical dosage forms. These SSRIs are fluoxetine, fluvoxamine, and paroxetine, the most prescribed drugs for the treatment of depression. The proposed assay was based on the formation of orange-colored -substituted naphthoquinone derivatives upon the reaction of SSRIs with 1,2-naphthoquinone-4-sulphonate (NQS) in alkaline media. The assay was conducted in 96-microwell assay plates, and the absorbances of the reaction products were measured by a microplate reader at their maximum absorbance wavelengths. The optimum conditions of the reaction were refined and established. Under these conditions, calibration curves were generated, and linear regression equations were computed. The linear relations between the absorbances and drug concentrations were linear with good correlation coefficients (0.9992-0.9997) in the range of 2-80 µg/mL. The assay limits of detection were in the range of 1.5-4.2 µg/mL. The precision was satisfactory as the values of relative standard deviation did not exceed 1.70%. The accuracy of the assay was ≥98.2%. The proposed MW-SPA was successfully applied to the analysis of the SSRIs in their pharmaceutical dosage forms with acceptable accuracy and precision; the label claims were 99.2-100.5% (±0.96-1.35%). The results of the proposed MW-SPA were compared with those of the official/pre-validated assays by statistical analysis with respect to the accuracy (by -test) and precision (by F-test). No significant differences were found between the calculated and theoretical values of the t- and F-tests at the 95% confidence level, proving similar accuracy and precision in the determination of SSRIs by both assays. The greenness of the proposed assay was confirmed by two metric tools. In addition, the assay is characterized with a high-throughput property which enables the simultaneous analysis of many samples in a short time. Therefore, the assay is a valuable tool for rapid routine application in pharmaceutical quality control units for the determination of the investigated SSRIs.
Topics: Selective Serotonin Reuptake Inhibitors; Spectrophotometry; Fluoxetine; Fluvoxamine; Pharmaceutical Preparations
PubMed: 37241961
DOI: 10.3390/molecules28104221 -
Molecules (Basel, Switzerland) May 2023This study discusses the development and validation of a universal microwell spectrophotometric assay for TKIs, regardless of the diversity in their chemical structures....
Development of Green and High Throughput Microplate Reader-Assisted Universal Microwell Spectrophotometric Assay for Direct Determination of Tyrosine Kinase Inhibitors in Their Pharmaceutical Formulations Irrespective the Diversity of Their Chemical Structures.
This study discusses the development and validation of a universal microwell spectrophotometric assay for TKIs, regardless of the diversity in their chemical structures. The assay depends on directly measuring the native ultraviolet light (UV) absorption of TKIs. The assay was carried out using UV-transparent 96-microwell plates and the absorbance signals were measured by a microplate reader at 230 nm, at which all TKIs had light absorption. Beer's law correlating the absorbances of TKIs with their corresponding concentrations was obeyed in the range of 2-160 µg mL with excellent correlation coefficients (0.9991-0.9997). The limits of detection and limits quantitation were in the ranges of 0.56-5.21 and 1.69-15.78 µg mL, respectively. The proposed assay showed high precision as the values of the relative standard deviations for the intra- and inter-assay precisions did not exceed 2.03 and 2.14%, respectively. The accuracy of the assay was proven as the recovery values were in the range of 97.8-102.9% (±0.8-2.4%). The proposed assay was successfully applied to the quantitation of all TKIs in their pharmaceutical formulations (tablets) with reliable results in terms of high accuracy and precision. The assay greenness was evaluated, and the results proved that the assay fulfils the requirements of green analytical approach. The proposed assay is the first assay that can analyse all TKIs on a single assay system without chemical derivatization or modifications in the detection wavelength. In addition, the simple and simultaneous handling of a large number of samples as a batch using micro-volumes of samples gave the assay the advantage of high throughput analysis, which is a serious demand in the pharmaceutical industry.
Topics: Tyrosine Kinase Inhibitors; Drug Compounding; Spectrophotometry; Tablets; High-Throughput Screening Assays
PubMed: 37241790
DOI: 10.3390/molecules28104049 -
Biosensors May 2023Lab-on-Chip (LoC) devices for performing real-time PCR are advantageous compared to standard equipment since these systems allow to conduct in-field quick analysis. The...
Lab-on-Chip (LoC) devices for performing real-time PCR are advantageous compared to standard equipment since these systems allow to conduct in-field quick analysis. The development of LoCs, where the components for performing the nucleic acid amplification are all integrated, can be an issue. In this work, we present a LoC-PCR device where thermalization, temperature control and detection elements are all integrated on a single glass substrate named System-on-Glass (SoG) obtained using metal thin-film deposition. By using a microwell plate optically coupled with the SoG, real-time reverse transcriptase PCR of RNA extracted from both a plant and human virus has been carried out in the developed LoC-PCR device. The limit of detection and time of analysis for the detection of the two viruses by using the LoC-PCR were compared with those achieved by standard equipment. The results showed that the two systems can detect the same concentration of RNA; however, the LoC-PCR performs the analysis in half of the time compared to the standard thermocycler, with the advantage of the portability, leading to a point-of-care device for several diagnostic applications.
Topics: Humans; Lab-On-A-Chip Devices; Nucleic Acid Amplification Techniques; Viruses; Real-Time Polymerase Chain Reaction; RNA, Viral
PubMed: 37232905
DOI: 10.3390/bios13050544 -
Medicina (Kaunas, Lithuania) Apr 2023Lorlatinib (LOR) belongs to the third-generation anaplastic lymphoma kinase (ALK) tyrosine kinase inhibitors. People who are diagnosed with ALK-positive metastatic and...
Novel High-Throughput Microwell Spectrophotometric Assay for One-Step Determination of Lorlatinib, a Novel Potent Drug for the Treatment of Anaplastic Lymphoma Kinase (ALK)-Positive Non-Small Cell Lung Cancer.
Lorlatinib (LOR) belongs to the third-generation anaplastic lymphoma kinase (ALK) tyrosine kinase inhibitors. People who are diagnosed with ALK-positive metastatic and advanced non-small cell lung cancer (NSCLC) are eligible to get it as a first-line treatment option after it was given the approval by "the Food and Drug Administration (FDA)". However, no study has described constructing high-throughput analytical methodology for LOR quantitation in dosage form. For the first time, this work details the construction of a high-throughput, innovative microwell spectrophotometric assay (MW-SPA) for single-step assessment of LOR in its tablet form, for use in pharmaceutical quality control. Assay depended on charge transfer complex (CTC) formation between LOR, as electron donor, with 2,3-dichloro-3,5-dicyano-1,4-benzoquinone (DDQ), as π-electron acceptor. Reaction conditions were adjusted, the CTC was characterized by ultraviolet (UV)-visible spectrophotometry and computational molecular modeling, and its electronic constants were determined. Site of interaction on LOR molecule was allocated and reaction mechanism was suggested. Under refined optimum reaction conditions, the procedures of MW-SPA were performed in 96-well assay plates, and the responses were recorded by an absorbance plate reader. Validation of the current methodology was performed in accordance with guidelines of "the International Council on Harmonization (ICH)", and all validation parameters were acceptable. Limits of detection and quantitation of MW-SPA were 1.8 and 5.5 µg/well, respectively. The assay was applied with great success for determining LOR in its tablets. This The assay is straightforward, economic and has high-throughput characteristics. Consequently, the assay is recommended as a valuable analytical approach in quality control laboratories for LOR's tablets' analysis.
Topics: Humans; Anaplastic Lymphoma Kinase; Carcinoma, Non-Small-Cell Lung; Lactams, Macrocyclic; Lung Neoplasms; Protein Kinase Inhibitors; Spectrophotometry
PubMed: 37109714
DOI: 10.3390/medicina59040756 -
Molecules (Basel, Switzerland) Mar 2023This study describes the development of a one-step microwell spectrofluorimetric assay (MW-SFA) with high sensitivity and throughput for the determination of four...
One-Step Microwell Plate-Based Spectrofluorimetric Assay for Direct Determination of Statins in Bulk Forms and Pharmaceutical Formulations: A Green Eco-Friendly and High-Throughput Analytical Approach.
This study describes the development of a one-step microwell spectrofluorimetric assay (MW-SFA) with high sensitivity and throughput for the determination of four statins in their pharmaceutical and formulations (tablets). These statins were pitavastatin (PIT), fluvastatin (FLU), rosuvastatin (ROS) and atorvastatin (ATO). The MW-SFA involves the measurement of the native fluorescence of the statin aqueous solutions. The assay was conducted in white opaque 96-microwell plates, and the fluorescence intensities of the solutions were measured by using a fluorescence microplate reader. The optimum conditions of the assay were established; under which, linear relationships with good correlation coefficients (0.9991-0.9996) were found between the fluorescence intensity and the concentration of the statin drug in a range of 0.2-200 µg mL with limits of detection in a range of 0.1-4.1 µg mL. The proposed MW-SFA showed high precision, as the values of the relative standard deviations did not exceed 2.5%. The accuracy of the assay was proven by recovery studies, as the recovery values were 99.5-101.4% (±1.4-2.1%). The assay was applied to the determination of the investigated statins in their tablets. The results were statistically compared with those obtained by a reference method and the results proved to have comparable accuracy and precision of both methods, as evidenced by the t- and F-tests, respectively. The green and eco-friendly feature of the proposed assay was assessed by four different metric tools, and all the results proved that the assay meets the requirements of green and eco-friendly analytical approaches. In addition, ever-increasing miniaturization as handling of large numbers of micro-volume samples simultaneously in the proposed assay gave it a high-throughput feature. Therefore, the assay is a valuable tool for the rapid routine application in the pharmaceutical quality control units for the determination of statins.
Topics: Hydroxymethylglutaryl-CoA Reductase Inhibitors; Drug Compounding; Spectrometry, Fluorescence; Tablets
PubMed: 36985779
DOI: 10.3390/molecules28062808 -
Medicina (Kaunas, Lithuania) Feb 2023This study presents the development and validation of the 96-microwell-based spectrofluorimetric (MW-SFL) and high performance liquid chromatography (HPLC) with...
Development of Novel Microwell-Based Spectrofluorimetry and High-Performance Liquid Chromatography with Fluorescence Detection Methods and High Throughput for Quantitation of Alectinib in Bulk Powder and Urine Samples.
This study presents the development and validation of the 96-microwell-based spectrofluorimetric (MW-SFL) and high performance liquid chromatography (HPLC) with fluorescence detection (HPLC-FD) methods for the quantitation of alectinib (ALC) in its bulk powder form and in urine samples. The MW-SFL was based on the enhancement of the native fluorescence of ALC by the formation of micelles with the surfactant cremophor RH 40 (Cr RH 40) in aqueous media. The MW-SFL was executed in a 96-microwell plate and the relative fluorescence intensity (RFI) was recorded by utilizing a fluorescence plate reader at 450 nm after excitation at 280 nm. The HPLC-FD involved the chromatographic separation of ALC and ponatinib (PTB), as an internal standard (IS), on a C column and a mobile phase composed of methanol:potassium dihydrogen phosphate pH 7 (80:20, /) at a flow rate of 2 mL min. The eluted ALC and PTB were detected by utilizing a fluorescence detector set at 365 nm for excitation and 450 nm for emission. Validation of the MW-SFL and HPLC-FD analytical methods was carried out in accordance with the recommendations issued by the International Council for Harmonization (ICH) for the process of validating analytical procedures. Both methods were efficaciously applied for ALC quantitation in its bulk form as well as in spiked urine; the mean recovery values were ≥86.90 and 95.45% for the MW-SFL and HPLC-FD methods, respectively. Both methodologies are valuable for routine use in quality control (QC) laboratories for determination of ALC in pure powder form and in human urine samples.
Topics: Humans; Chromatography, High Pressure Liquid; Powders; Piperidines; Carbazoles
PubMed: 36984441
DOI: 10.3390/medicina59030441 -
Cellular and Molecular Life Sciences :... Mar 2023Multicellular tumor spheroids are rapidly emerging as an improved in vitro model with respect to more traditional 2D culturing. Microwell culturing is a simple and...
Multicellular tumor spheroids are rapidly emerging as an improved in vitro model with respect to more traditional 2D culturing. Microwell culturing is a simple and accessible method for generating a large number of uniformly sized spheroids, but commercially available systems often do not enable researchers to perform complete culturing and analysis pipelines and the mechanical properties of their culture environment are not commonly matching those of the target tissue. We herein report a simple method to obtain custom-designed self-built microwell arrays made of polydimethylsiloxane or agarose for uniform 3D cell structure generation. Such materials can provide an environment of tunable mechanical flexibility. We developed protocols to culture a variety of cancer and non-cancer cell lines in such devices and to perform molecular and imaging characterizations of the spheroid growth, viability, and response to pharmacological treatments. Hundreds of tumor spheroids grow (in scaffolded or scaffold-free conditions) at homogeneous rates and can be harvested at will. Microscopy imaging can be performed in situ during or at the end of the culture. Fluorescence (confocal) microscopy can be performed after in situ staining while retaining the geographic arrangement of spheroids in the plate wells. This platform can enable statistically robust investigations on cancer biology and screening of drug treatments.
Topics: Humans; Spheroids, Cellular; Neoplasms; Cell Line; Cell Line, Tumor
PubMed: 36929461
DOI: 10.1007/s00018-023-04748-1 -
Nature Biotechnology Nov 2023Current single-cell RNA-sequencing approaches have limitations that stem from the microfluidic devices or fluid handling steps required for sample processing. We develop...
Current single-cell RNA-sequencing approaches have limitations that stem from the microfluidic devices or fluid handling steps required for sample processing. We develop a method that does not require specialized microfluidic devices, expertise or hardware. Our approach is based on particle-templated emulsification, which allows single-cell encapsulation and barcoding of cDNA in uniform droplet emulsions with only a vortexer. Particle-templated instant partition sequencing (PIP-seq) accommodates a wide range of emulsification formats, including microwell plates and large-volume conical tubes, enabling thousands of samples or millions of cells to be processed in minutes. We demonstrate that PIP-seq produces high-purity transcriptomes in mouse-human mixing studies, is compatible with multiomics measurements and can accurately characterize cell types in human breast tissue compared to a commercial microfluidic platform. Single-cell transcriptional profiling of mixed phenotype acute leukemia using PIP-seq reveals the emergence of heterogeneity within chemotherapy-resistant cell subsets that were hidden by standard immunophenotyping. PIP-seq is a simple, flexible and scalable next-generation workflow that extends single-cell sequencing to new applications.
Topics: Humans; Animals; Mice; Microfluidics; High-Throughput Nucleotide Sequencing; Single-Cell Analysis; Genomics; Transcriptome
PubMed: 36879006
DOI: 10.1038/s41587-023-01685-z -
Biomaterials and Biosystems Aug 2022Human 3D liver microtissues/spheroids are powerful models to study drug-induced liver injury (DILI) but the small number of cells per spheroid limits the models'...
Human 3D liver microtissues/spheroids are powerful models to study drug-induced liver injury (DILI) but the small number of cells per spheroid limits the models' usefulness to study drug metabolism. In this work, we scale up the number of spheroids on both a plate and a standardized organ-chip platform by factor 100 using a basic method which requires only limited technical expertise. We successfully generated up to 100 spheroids using polymer-coated microwells in a 96-well plate (= liver-plate) or organ-chip (= liver-chip). Liver-chips display a comparable cellular CYP3A4 activity, viability, and biomarker expression as liver spheroids for at least one week, while liver-plate cultures display an overall reduced hepatic functionality. To prove its applicability to drug discovery and development, the liver-chip was used to test selected reference compounds. The test system could discriminate toxicity of the DILI-positive compound tolcapone from its less hepatotoxic structural analogue entacapone, using biochemical and morphological readouts. Following incubation with diclofenac, the liver-chips had an increased metabolite formation compared to standard spheroid cultures. In summary, we generated a human liver-chip model using a standardized organ-chip platform which combines up to 100 spheroids and can be used for the evaluation of both drug safety and metabolism.
PubMed: 36824483
DOI: 10.1016/j.bbiosy.2022.100054 -
Data in Brief Apr 2023Red blood cell (RBC) deformability is a vital biophysical property that dictates the ability of these cells to repeatedly squeeze through small capillaries in the...
Red blood cell (RBC) deformability is a vital biophysical property that dictates the ability of these cells to repeatedly squeeze through small capillaries in the microvasculature. This capability is known to differ between individuals and degrades due to natural aging, pathology, and cold storage. There is great interest in measuring RBC deformability because this parameter is a potential biomarker of RBC quality for use in blood transfusions. Measuring this property from microscopy images would greatly reduce the effort required to acquire this information, as well as improve standardization across different centers. This dataset consists of live cell microscopy images of RBC samples from 10 healthy donors. Each RBC sample is sorted into fractions based on deformability using the microfluidic ratchet device. Each deformability fraction is imaged in microwell plates using a Nikon CFI S Plan Fluor ELWD 40 × objective and a Nikon DS-Qi2 CMOS camera on a Nikon Ti-2E inverted microscope. This data could be reused to develop deep learning algorithms to associate live cell images with cell deformability.
PubMed: 36798597
DOI: 10.1016/j.dib.2023.108928