-
BMC Oral Health Jun 2024Failure of orthodontic bracket bonds is a common occurrence during orthodontic treatment. This study investigated the impact of Er: YAG laser-based removal of adhesive... (Comparative Study)
Comparative Study
BACKGROUND
Failure of orthodontic bracket bonds is a common occurrence during orthodontic treatment. This study investigated the impact of Er: YAG laser-based removal of adhesive from the bases of metal and ceramic brackets for re-bonding.
METHODS
A total of 168 extracted premolars were collected from patients. 84 metal brackets were used to be bonded on the buccal surface of the premolars in Groups 1, 2, 3 and 4, while 84 ceramic brackets were applied in Groups I, II, III and IV. Group 1/I represented the initial bonding group, with Group 2/II being the re-bonding group with new brackets, while Groups 3/III and 4/ IV received recycled brackets treated by Er: YAG laser or flaming respectively. Both the first and second de-bonding were performed in all samples using a universal testing machine to determine the shear bond strength (SBS). The adhesive remnant index (ARI) was evaluated using a stereo-microscope. The new and the treated bracket bases were evaluated using scanning electron microscopy (SEM). Differences in initial bonding and re-bonding ability were analyzed through one-way ANOVAs, and differences in ARI were assessed with the Kruskal-Wallis test.
RESULTS
Greater amounts of adhesive residue were observed on ceramic brackets treated by laser. The SBS values for recycled metal brackets in Group 3 (26.13 MPa) were comparable to Group 1 (23.62 MPa) whereas they differed significantly from Group 4 (12.54 MPa). No significant differences in these values were observed when comparing the 4 groups with ceramic brackets. ARI score in Group 4 (2-3 points) differed significantly from the three other groups (P < 0.05). For Group I, II, III and IV, similar ARI scores were observed (P > 0.05). SEM analysis didn't show apparent damage of bracket bases consisting of either metal or ceramic material treated by Er: YAG laser.
CONCLUSIONS
Er: YAG laser treatment was superior to flame treatment as a means of removing adhesive without damaging the brackets. SBS values and ARI scores following Er: YAG laser treatment were similar to those for new brackets, offering further support for Er: YAG laser treatment as a viable means of recycling debonded brackets.
Topics: Orthodontic Brackets; Lasers, Solid-State; Humans; Dental Bonding; Ceramics; Dental Debonding; Shear Strength; Dental Stress Analysis; Microscopy, Electron, Scanning; Materials Testing; Surface Properties; Bicuspid; Dental Alloys; Resin Cements
PubMed: 38902669
DOI: 10.1186/s12903-024-04504-2 -
Diagnostics (Basel, Switzerland) May 2024CBCT (cone beam computed tomography) is an imaging investigation that provides three-dimensional (3D) images of craniofacial structures. The purpose of this study is to...
CBCT (cone beam computed tomography) is an imaging investigation that provides three-dimensional (3D) images of craniofacial structures. The purpose of this study is to determine the mechanical behavior of an orthodontic system where the lingual treatment technique was used in a 25-year-old female patient from whom a set of CBCT scans was used. CBCT images were processed through software programs such as Invesalius, Geomagic, and Solid Works, to create models containing virtual solids. These models were then imported into Ansys Workbench 2019 R3 (a finite element method software program) for successive simulations to generate displacement maps, deformations, stress distributions, and diagrams. We observed that in the lingual technique, the lowest force occurring on the maxillary teeth is at 1.1, while the highest force appears at 2.3. In the mandible, the lowest force occurs at 4.6, and the highest force at 3.1. The values of the forces and the results of the finite element method can represent a basis for the innovation of new orthodontic springs and also of bracket elements. Thus, by using new technologies, orthodontic practice can be significantly improved for the benefit of patients. Other virtual methods and techniques can be used in future studies, including the application of virtual reality for orthodontic diagnosis.
PubMed: 38893697
DOI: 10.3390/diagnostics14111171 -
BioMed Research International 2024To evaluate the enamel bonding ability and orthodontic adhesive resin degree of conversion using the experimental bracket design. . Thirteen bovine teeth were used in...
OBJECTIVE
To evaluate the enamel bonding ability and orthodontic adhesive resin degree of conversion using the experimental bracket design. . Thirteen bovine teeth were used in the study. The experimental bracket was modified with a translucent region in the center of its body. After enamel etching, Orthocem orthodontic adhesive (FGM, Joinville, Brazil) was applied on the bracket base for bonding. The groups were divided as follows ( = 10 per group): (1) control (CB) with standard brackets and (2) spot bracket (SB) with experimental brackets featuring a 0.8 mm translucent region at the center using carbide bur. Shear bond strength (SBS) was evaluated after 24 hours in a universal testing machine and adhesive remnant index (ARI). The degree of conversion (DC) was analyzed using Raman spectroscopy ( = 3 per group). Data were then analyzed using Student's -test and Mann-Whitney statistical methods.
RESULTS
The SB group exhibited a higher mean SBS (10.33 MPa) compared to the CB Group (8.77 MPa). However, there was no statistical difference between the groups ( = 0.376). Both SB and CB groups had a mean ARI score of 1. Raman analysis revealed a higher degree of conversion in the SB group (49.3%) compared to the CB group (25.9%).
CONCLUSIONS
The experimental support showed a higher degree of adhesive conversion, although there was no significant increase in bond strength.
Topics: Orthodontic Brackets; Animals; Cattle; Dental Bonding; Dental Enamel; Composite Resins; Shear Strength; Polymerization; Materials Testing; Dental Cements; Resin Cements
PubMed: 38884017
DOI: 10.1155/2024/7457900 -
Case Reports in Dentistry 2024Root resorption is a commonly recognized risk of orthodontic treatment and can range from minimal changes at the apex to aggressive and extensive erosion of tooth...
Root resorption is a commonly recognized risk of orthodontic treatment and can range from minimal changes at the apex to aggressive and extensive erosion of tooth structure. The following report is aimed at presenting a rare case of idiopathic aggressive preeruptive root resorption in a maxillary second premolar of a young child prior to orthodontic force. During phase I orthodontic treatment, the maxillary premolar required surgical exposure with a bracket and chain to assist in its eruption. Before the exposure, a cone beam computed tomography (CBCT) was captured to aid in localizing the premolar and its relationship to vital structures. In addition to identifying relevant anatomy, the image also revealed an incidental finding of extensive external cervical root resorption. The risks, benefits, prognosis, and alternatives of continuing with surgical exposure of the affected premolar were presented to the guardian. The informed and consented decision was made to continue with the exposure and subsequent orthodontic treatment to align the tooth in the arch. Upon eruption to the occlusal plane, the tooth was amenable to endodontic pulp vitality testing, Endo Ice, and a follow-up CBCT. It was determined that there was advanced aggressive progression of the resorptive process. The Patel Classification 3Cd/Class 4 Heithersay ECR diagnosis and a poor prognosis ultimately resulted in the extraction of the tooth. Management of this case highlights a number of important clinical features including the rarity of advanced preeruptive idiopathic external cervical root resorption, a multidisciplinary approach (orthodontic, endodontic, and surgical) to diagnose and manage the ECR, and the importance of prescribing and acquisition of appropriate imaging to aid in the early diagnosis of the entity. This case report will add to the body of knowledge of a rare incidence of advanced ECR on a young patient with a nontraumatized, unerupted maxillary second premolar.
PubMed: 38884009
DOI: 10.1155/2024/6590778 -
Journal of Pharmacy & Bioallied Sciences Apr 2024Tooth movement in orthodontic therapy is connected to the frictional force that is created as the wire passes over the bracket. It is possible for teeth to move quickly...
Tooth movement in orthodontic therapy is connected to the frictional force that is created as the wire passes over the bracket. It is possible for teeth to move quickly when friction is at a minimum. Wires coated with nanoparticles have been found to reduce friction as a result of current developments in the orthodontics sector. Having an antimicrobial property is an added benefit. To reduce the friction generated by brackets, wires, and bands by lessening their cytotoxicity, this study examines the potential use of TiO2 nanoparticles in orthodontics. A monolayer of L929 was utilized in an indirect cytotoxicity test to evaluate the cytotoxicity of the coated orthodontic wire. The absence of reactive zones in our sample data demonstrates that TiO2 is not cytotoxic. Considering the results of our study, we conclude that TiO2 is secure for use as a coating for orthodontic devices.
PubMed: 38882869
DOI: 10.4103/jpbs.jpbs_824_23 -
Journal of Pharmacy & Bioallied Sciences Apr 2024Nano-coating of orthodontic brackets with a combination or hybrid of metals and metal oxides may reduce the streptococcus mutans count and incidence of enamel...
Nano-coating of orthodontic brackets with a combination or hybrid of metals and metal oxides may reduce the streptococcus mutans count and incidence of enamel decalcification seen around brackets in patients undergoing fixed orthodontic treatment. In total, 255 orthodontic brackets (3M Unitek, Monrovia, California, USA) were divided into one control group (group I) of 60 and three experimental groups of 65 each (groups II, III, and IV). The experimental group brackets were coated with a combination of silver-zinc oxide, copper oxide -zinc oxide, and silver-copper oxide nanoparticles using physical vapour deposition method. The two nanoparticles used for each group were mixed in the ratio of 1:1 by weight for providing a uniform hybrid coating. Sixty brackets from each group were used for microbiological evaluation of antibacterial activity against Streptococcus mutans in blood agar medium, and the remaining five brackets from each experimental group were used for SEM analysis to check the uniformity of the coating. Nano-coated brackets demonstrated better antibacterial properties than uncoated brackets. Copper oxide-zinc oxide nanoparticles coated brackets demonstrated better antibacterial properties than the silver-zinc oxide and silver- copper oxide coated brackets.
PubMed: 38882773
DOI: 10.4103/jpbs.jpbs_1190_23 -
Journal of Pharmacy & Bioallied Sciences Apr 2024In this, study's objective is to assess the shear bond strength (SBS) of metal and ceramic orthodontic brackets that have been adhered to enamel using a conventional...
AIM
In this, study's objective is to assess the shear bond strength (SBS) of metal and ceramic orthodontic brackets that have been adhered to enamel using a conventional acid etch/primer and self-etching primer (SEP) adhesive method.
MATERIALS AND METHODS
One hundred excised human premolars were bonded on brackets and were divided into group 1 -Metal brackets were bonded on teeth and group 2 -Ceramic brackets were bonded on teeth. These two groups were further subdivided: subgroup 1a - 25 metal brackets bonded using conventional acid etch/primer adhesive system, subgroup 1b - 25 metal brackets bonded using SEP, subgroup 2a - 25 ceramic brackets bonded using conventional acid etch/primer adhesive system, and subgroup 2b - 25 ceramic brackets bonded using SEP; brackets were debonded using a computerized Instron universal testing machine.
RESULTS
The mean value of SBS of metal and ceramic brackets bonded using conventional acid etch/primer adhesive systems had higher SBS than those bonded using SEP. SBS ranged from 7.95 to 12.24 MPa which was in the acceptable clinical range.
CONCLUSION
SBS values of all four subgroups exceeded the range of 6-8 MPa observed to be acceptable for routine clinical use.
PubMed: 38882726
DOI: 10.4103/jpbs.jpbs_386_23 -
Progress in Orthodontics Jun 2024Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been... (Meta-Analysis)
Meta-Analysis Review
INTRODUCTION
Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been associated with increased microbial colonization, which could adversely affect periodontal health.
AIM
This systematic review compares the periodontal effects of elastomeric and steel ligatures used for orthodontic fixed appliances.
METHODS
Unrestricted literature search of 7 databases (MEDLINE, Scopus, Web of Science, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and Virtual Health Library) up to July 2023 were performed for randomized / non-randomized clinical studies on humans comparing the two ligation methods during fixed-appliance therapy. After duplicate study selection, data extraction, and risk-of-bias assessment with the Risk of Bias (RoB) 2 or the Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) tool, random-effects meta-analyses of Mean Differences (MD) or Standardized Mean Differences (SMD) and their 95% confidence intervals (CIs) were carried out, followed by assessment of certainty of existing evidence with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach.
RESULTS
A total of 11 studies (3 randomized / 8 non-randomized) with 354 patients (mean age 14.7 years and 42% male) were included. No statistically significant differences were seen for plaque index (5 studies; SMD = 0.48; 95% CI = -0.03 to 1.00; P = 0.07), gingival index (2 studies; MD = 0.01; 95% CI = -0.14 to 0.16; P = 0.89), probing pocket depth (2 studies; MD = 0; 95% CI = -0.17 to 0.16; P = 0.97), or Streptococcus mutans counts (4 studies; SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21). Elastomeric ligatures were associated with moderately increased total bacterial load (3 studies; SMD = 0.43; 95% CI = 0.10 to 0.76; P = 0.03). Confidence in these estimates was low in all instances due to the inclusion of non-randomized studies with high risk of bias.
CONCLUSIONS
Existing low quality evidence indicates that ligature method does not seem to influence the periodontal health during fixed treatment, even if elastomeric ligatures are associated with a moderate increase of bacterial load.
REGISTRATION
PROSPERO (CRD42023444383).
Topics: Humans; Elastomers; Orthodontic Appliances, Fixed; Steel; Periodontal Index; Orthodontic Brackets; Ligation
PubMed: 38880839
DOI: 10.1186/s40510-024-00520-8 -
Biomaterial Investigations in Dentistry 2024The purpose of this study was to evaluate the effect of orthodontic bracket base shape on shear bond strength (SBS) to human enamel and assess the nature of debonding...
The purpose of this study was to evaluate the effect of orthodontic bracket base shape on shear bond strength (SBS) to human enamel and assess the nature of debonding fractures using the Adhesive Remnant Index (ARI). Orthodontic brackets with different-shaped bases (flower, heart, rectangle) were bonded to 120 extracted human third molars. Shear bond strength was measured using a Servohydraulic Test System at 24 h and 2 months after bonding. Adhesive Remnant Index scores were evaluated under 10x magnification to assess the amount of resin left on the tooth. The control bracket (rectangular base shape) had the highest mean SBS (26.8 ± 8.2 megapascals [MPa]), and significantly differed from the flower (17.2 ± 4.4 MPa) and heart (18.9 ± 3.5 MPa) base shapes ( < 0.001). The mean SBS between debonding times at 24 h (21.5 ± 7.4 MPa) and 2 months (20.4 ± 6.7 MPa) were not statistically significant > 0.05). Analysis of ARI scores showed a significant difference between flower-24 h versus heart-2 months ( = 0.039), flower-24 h versus heart-24 h ( = 0.004), and control-2 months versus heart-24 h ( = 0.015). Bracket base shape influenced SBS, with the rectangular base shape having a higher mean SBS compared to flower and heart base shapes. Variations in ARI scores occurred based on bracket shape and were of a mixed adhesive-cohesive nature. All bracket shapes had bond strengths above the clinically acceptable range of 6-8 MPa, and may thus provide adequate SBS in a clinical situation.
PubMed: 38873367
DOI: 10.2340/biid.v11.40585 -
Heliyon Jun 2024With the advancement of 3-dimensionally (3D) printing technology, orthodontists can design and fabricate 3D-printed indirect bonding trays and transfer jigs for lingual...
With the advancement of 3-dimensionally (3D) printing technology, orthodontists can design and fabricate 3D-printed indirect bonding trays and transfer jigs for lingual brackets independently from the laboratory. The present article describes, in detail, the digital workflows for designing and fabricating 3D-printed lingual bracket indirect bonding trays and transfer jigs. Additionally, it aims to demonstrate the effectiveness of this approach in managing common orthodontic issues in adult patients. The first case report exemplifies the successful management of moderate crowding in a Class I adult patient using a non-extraction approach with lingual brackets and flexible 3D-printed indirect bonding trays. The second case illustrates the application of lingual brackets and rigid 3D-printed indirect bonding trays in managing a skeletal Class II adult patient with mouth protrusion requiring four-bicuspid extractions. The achieved good treatment results might demonstrate the high transfer accuracy of 3D-printed lingual bracket indirect bonding trays. Additional studies with large sample sizes should be conducted to compare the effectiveness and efficiency of 3D-printed trays with other tray types.
PubMed: 38867963
DOI: 10.1016/j.heliyon.2024.e32035