Annals of Medicine 2023To compare the postoperative binocular visual quality in six treatment protocols for bilateral age-related cataract surgery with presbyopia correction for clinical...
Comparison of binocular visual quality in six treatment protocols for bilateral cataract surgery with presbyopia correction: a prospective two-center single-blinded cohort study.
OBJECTIVE
To compare the postoperative binocular visual quality in six treatment protocols for bilateral age-related cataract surgery with presbyopia correction for clinical decisions.
MATERIALS AND METHODS
In this prospective two-center single-blinded cohort study, participants from North or South China who underwent bilateral phacoemulsification and intraocular lens implantation were divided into six protocols: monovision, diffractive bifocal, mixed, refractive bifocal, trifocal, and micro-monovision extended range of vision (EROV). Binocular visual quality was evaluated at 3 months postoperatively, including binocular uncorrected full-range visual acuity, binocular defocus curves (depth of focus [DoF] and area under the curve [AUC]), binocular visual function (fusion function and stereopsis), binocular subjective spectacle independence rates, visual analog scale (VAS) of overall satisfaction, 25-item visual function questionnaire (VFQ-25), and binocular dysphotopsia symptoms.
RESULTS
Of the 300 enrolled patients, 272 (90.7%; 544 eyes) were analyzed. The trifocal protocol showed excellent binocular full-range visual acuity and the best performance for most DoFs and AUCs. The monovision protocol presented the worst binocular visual quality in most perspectives, especially in convergence, distance, and near stereopsis ( < 0.001). The full-range subjective spectacle independence rates were sorted from highest to lowest as follows: trifocal (84.8%), refractive bifocal (80.9%), EROV (80.0%), mixed (73.3%), diffractive bifocal (65.2%), and monovision (32.6%) protocols, with no statistically significant differences between the former five protocols ( > 0.05). The EROV protocol achieved the highest VAS and VFQ-25 scores. The incidence of postoperative binocular dysphotopsia symptoms was comparable in all protocols.
CONCLUSIONS
The trifocal protocol showed the best performance, and the monovision protocol presented the worst performance in most perspectives of binocular visual quality for presbyopia correction. The refractive bifocal, mixed, or EROV protocols can provide an approximate performance as a trifocal protocol. Ophthalmologists can customize therapies using different protocols.
Topics: Humans; Presbyopia; Cohort Studies; Prospective Studies; Cataract; Clinical Protocols; Randomized Controlled Trials as Topic
PubMed: 37734409
DOI: 10.1080/07853890.2023.2258894 -
Journal of Refractive Surgery... Sep 2023To evaluate visual performance, spectacle independence, and quality of vision of new intraocular lenses (IOLs) for presbyopia correction with an aspheric inverted...
PURPOSE
To evaluate visual performance, spectacle independence, and quality of vision of new intraocular lenses (IOLs) for presbyopia correction with an aspheric inverted meniscus optical design (ArtIOLs; Voptica SL) in patients undergoing bilateral cataract surgery.
METHODS
In this prospective study, 60 eyes from 30 patients implanted bilaterally with Art40 and Art70 IOLs were included. These new IOLs were designed with an inverted meniscus shape to improve the peripheral performance and with aspheric surfaces to induce different amounts of negative spherical aberration in each IOL model. Distance-corrected and uncorrected through-focus visual acuities and contrast sensitivity were measured 1 to 3 months after surgery. Twenty-eight patients answered Patient Reported Spectacle Independence (PRSIQ) and Quality of Vision (QoV) questionnaires.
RESULTS
Mean monocular (Art40 and Art70) and binocular (Art40/70) corrected distance visual acuities (CDVA) were zero logMAR (20/20). Binocular uncorrected distance visual acuity (UDVA) at far, intermediate (66 cm), and near (40 cm) distances was 0.00 ± 0.01, 0.01 ± 0.03, and 0.09 ± 0.09 logMAR, respectively. Spectacle independence was achieved by 24 (85.7%) patients for far and intermediate vision and 20 patients (71.4%) for near vision. The number of patients never reporting experiencing glare, halos, and starbursts was 28, 27, and 26 (100%, 96.4%, and 92.9%), respectively.
CONCLUSIONS
The binocular combination of two ArtIOLs models (Art40 and Art70) significantly extended the depth of focus up to at least 40 cm. This combination resulted in a full range of vision with a high level of spectacle independence and without the compromise of halos or dysphotopsias. .
Topics: Humans; Patient Satisfaction; Prospective Studies; Lenses, Intraocular; Cataract Extraction; Meniscus
PubMed: 37675912
DOI: 10.3928/1081597X-20230802-01 -
BMC Ophthalmology Sep 2023Prevention of myopia should begin before school age. However, few population-based cohort studies have investigated refractive status in preschool children with...
BACKGROUND
Prevention of myopia should begin before school age. However, few population-based cohort studies have investigated refractive status in preschool children with cycloplegia. This study aimed to investigate the post-COVID-19 refraction and ocular biometric parameters of preschool children in Beijing Tongzhou District.
METHODS
A population-based cohort study of kindergarten children in Tongzhou District, Beijing, commenced in November 2021. The present study reports data from the first year of the aforementioned population-based study. We selected children aged 3-6 years from nine kindergartens. Biometric parameters, including axial length (AL), anterior chamber depth (ACD), and corneal radius of curvature (CR), were collected before cycloplegia. Cycloplegic refraction was also measured. The spherical equivalent (SE), lens power (LP), and AL-to-CR ratio were calculated. Multiple linear regression analysis was used to analyse the correlation between refraction and ocular biometric parameters.
RESULTS
A total of 1,505 children completed the examination, and a mean SE of 1.24 ± 0.91 D was found. The overall prevalence of myopia was 1.93%. The mean AL, ACD, CR, LP, and AL-to-CR ratio were 22.24 ± 0.70 mm, 3.28 ± 0.26 mm, 7.77 ± 0.26 mm, 26.01 ± 1.56 D, and 2.86 ± 0.07, respectively. Longer AL, deeper ACD, larger AL-to-CR ratio, and lower LP were associated with older age; the CR was not significantly different among different ages. In the multiple linear regression analysis, after adjusting for sex and age, the model that included AL, CR, and LP explained 87% of the SE variation. No differences were observed in the prevalence of myopia or the SE in this particular age range.
CONCLUSION
The findings of this study suggest that a large proportion of preschool children in Beijing are mildly hyperopic, with a considerably low prevalence of myopia. In preschool children, refractive development was found to present mild hyperopia rather than emmetropia or myopia, a phenomenon that is characteristic of this age range.
Topics: Child; Child, Preschool; Humans; Beijing; Cohort Studies; COVID-19; Myopia; Hyperopia; Presbyopia; Cornea; Biometry
PubMed: 37670238
DOI: 10.1186/s12886-023-03112-y -
Klinische Monatsblatter Fur... Nov 2023
Topics: Humans; Presbyopia; Vision, Monocular; Lens Implantation, Intraocular; Lenses, Intraocular
PubMed: 37647937
DOI: 10.1055/a-2162-7758 -
Investigative Ophthalmology & Visual... Aug 2023The mechanical properties of the crystalline lens are related to its optical function of accommodation, and their changes with age are one of the potential causes for...
PURPOSE
The mechanical properties of the crystalline lens are related to its optical function of accommodation, and their changes with age are one of the potential causes for presbyopia. We estimated the mechanical parameters of the crystalline lens using quantitative optical coherence tomography (OCT) imaging and wavefront sensing data from accommodating participants and computer modeling.
METHODS
Full-lens shape data (from quantitative swept-source OCT and eigenlens representation) and optical power data (from Hartmann-Shack wavefront sensor) were obtained from 11 participants (22-30 years old) for relaxed accommodation at infinity and -4.5 D accommodative demand. Finite element models of lens, capsular bag, zonulae, and ciliary body were constructed using measured lens geometry and literature data, assuming a 60-mN radial force. An inverse modeling scheme was used to determine the shear moduli of the nucleus and cortex of the lens, such that the simulated deformed (maximally stretched) lens matched the participant's lens at -4.5 D.
RESULTS
The shear moduli of the nucleus and cortex were 1.62 ± 1.32 and 8.18 ± 5.63 kPa, on average, respectively. The shear modulus of the nucleus was lower than that of the cortex for all participants evaluated. The average of the two moduli per participant was statistically significantly correlated with age (R2 = 0.76, P = 0.0049).
CONCLUSIONS
In vivo imaging and mechanical modeling of the crystalline lens allow estimations of the crystalline lens' mechanical properties. Differences between nuclear and cortical moduli and their dependency with age appear to be critical in accommodative function and likely in its impairment in presbyopia.
Topics: Humans; Male; Female; Lens, Crystalline; Accommodation, Ocular; Finite Element Analysis; Presbyopia; Tomography, Optical Coherence; Computer Simulation; Healthy Volunteers; Adult
PubMed: 37639248
DOI: 10.1167/iovs.64.11.31 -
Clinical Ophthalmology (Auckland, N.Z.) 2023To evaluate the clinical rationale of wavefront-shaping technology, describe how intraocular lenses (IOLs) using wavefront-shaping technology are differentiated from... (Review)
Review
PURPOSE
To evaluate the clinical rationale of wavefront-shaping technology, describe how intraocular lenses (IOLs) using wavefront-shaping technology are differentiated from refractive or diffractive optical presbyopia-correcting designs, and describe the mode of action of this technology.
METHODS
Extended depth of focus (EDoF) IOLs are the latest class of presbyopia-correcting IOLs addressing the growing demand of patients for reduced spectacle dependence. These use various optical technologies, including diffractive designs (eg, TECNIS Symfony ZXR00 and AT LARA 29 MP) and non-diffractive designs such as small aperture (eg, IC-8 IOL and XtraFocus Pinhole Implant), spherical aberration (eg, MINI WELL Ready and LuxSmart), and wavefront shaping (eg, AcrySof IQ Vivity DFT015 and Clareon Vivity CNWET0). Despite some improvement in visual acuity at intermediate and near distances, these technologies can still be associated with increased rate of visual disturbances or poorer distance vision compared with monofocal IOLs. One way to overcome such limitations is using a wavefront-shaping optical principle.
RESULTS
Clinical data show that wavefront-shaping technology results in a continuous EDoF compared with a monofocal IOL while exhibiting a minimal halo, similar to an aspheric monofocal IOL. Clinically, this translates to a lens that has proven to exceed the American National Standards Institute/American Academy of Ophthalmology criteria for an EDoF IOL.
CONCLUSION
The novel wavefront-shaping optic technology allows patients to achieve a continuous range of vision from distance to functional near with low levels of visual disturbances comparable with aspheric monofocal IOLs.
PubMed: 37614847
DOI: 10.2147/OPTH.S400083 -
Advances in Therapy Oct 2023Enhanced monofocal intraocular lenses (IOLs) represent a new type of lens, which should lead to a very good distance vision similar to monofocal IOLs and an improved...
INTRODUCTION
Enhanced monofocal intraocular lenses (IOLs) represent a new type of lens, which should lead to a very good distance vision similar to monofocal IOLs and an improved intermediate vision without increasing the risk for photic phenomena.
METHODS
The aim of this clinical observation/registry study was to directly compare two different IOL platforms (hydrophilic acrylic L-333 (group A) vs hydrophobic acrylic AN6Q (group B)) with the same enhanced monofocal optic principle but different material and haptic design in clinical routine. A total of 102 cataract cases (51:51) were included in the study. Groups A and B were similar regarding demographics, age (71.6 ± 9 years for L-333 and 73.6 ± 8 years for AN6Q) and their calculated IOL power (20.9 ± 2.0 D for L-333 and 21.5 ± 3.4 D for AN6Q). Spherical equivalent (SE), (un)corrected distance, intermediate visual acuity, the surgeons' experience and patient feedback were assessed postoperatively.
RESULTS
SE improved significantly in the AN6Q group, while the L-333 group showed a slightly smaller standard deviation postoperatively. In group A the uncorrected distance visual acuity (UDVA) improved from pre-op (0.43 ± 0.16 logMAR) to 1 month post-op (0.06 ± 0.04 logMAR) significantly and in group B from pre-op (0.54 ± 0.19 logMAR) to (0.05 ± 0.06 logMAR) postoperatively. Both groups showed excellent outcomes for distance without negative side effects. On testing uncorrected intermediate vision (80 cm) with Radner charts, 80% reached line 5 (0.0 logRAD) with fewer than one mistake and 10% reached line 4 (- 0.1 logRAD) in group A; 74% reached line 5 with fewer than one mistake and 4% reached line 4 in group B.
CONCLUSION
Both IOL models (groups A and B) provided satisfying results regarding implantation behaviour, refractive error, visual acuity and overall patient satisfaction. The haptic design might influence the outcome of refractive error. Long-term follow-up data should be considered in multicentre studies to further characterize both platforms and to optimize IOL power calculation (constants, surgeon factor). It was shown that the enhanced monofocal optic can provide good visual acuity for far distance and improve intermediate distance. This type of new monofocal optic design, which however must be strictly separated from typical refractive/diffractive multifocal, presbyopia-correcting lenses, could be a good option in standard cataract care.
Topics: Humans; Middle Aged; Aged; Aged, 80 and over; Lens Implantation, Intraocular; Haptic Technology; Lenses, Intraocular; Refractive Errors; Patient Satisfaction; Cataract; Prosthesis Design
PubMed: 37584899
DOI: 10.1007/s12325-023-02635-6 -
Journal of Clinical Medicine Jul 2023The aim of this research was to see if a refractive enhanced monofocal IOL (Eyhance IOL, IOL Abbott Medical Optics, Inc., Santa Ana, CA, USA) can provide better...
BACKGROUND
The aim of this research was to see if a refractive enhanced monofocal IOL (Eyhance IOL, IOL Abbott Medical Optics, Inc., Santa Ana, CA, USA) can provide better intermediate vision in patients undergoing phaco-vitrectomy due to cataract and epiretinal macular membrane (ERM).
METHODS
A nonrandomized prospective observational comparative study enrolled patients affected by cataract and ERM undergoing phaco-vitrectomy. A follow up of 6 months was established. Corrected and uncorrected visual acuity of both monocular and binocular types were assessed regarding intermediate and far distances. The CATQUEST 9-SF questionnaire was administered preoperatively and at the last follow-up.
RESULTS
Twenty-three eyes of twenty-three patients were enrolled, with 11 in the enhanced monofocal group. The uncorrected and corrected distance visual acuity after 6 months was not statistically different. Both monocular and binocular uncorrected intermediate visual acuity after 6 months were higher in the enhanced monofocal group ( < 0.001). The corrected intermediate visual acuity after 6 months was higher in the enhanced monofocal group ( = 0.01). The CATQUEST-9SF questionnaire showed significant differences in the variation between the preoperative condition and six-month postoperative results ( < 0.001).
CONCLUSIONS
This refractive enhanced monofocal IOL can provide better intermediate vision compared to a standard monofocal IOL in patients undergoing phaco-vitrectomy due to cataracts and ERM. Further studies are necessary to confirm these results.
PubMed: 37568418
DOI: 10.3390/jcm12155016