-
Physiological Reports May 2024Left ventricular noncompaction cardiomyopathy (LVNC) is a structural heart defect that has been associated with generation of arrhythmias in the population and is a...
Left ventricular noncompaction cardiomyopathy (LVNC) is a structural heart defect that has been associated with generation of arrhythmias in the population and is a cause of sudden cardiac death with severe systolic dysfunction and fatal arrhythmias. LVNC has gained increasing acknowledgment with increased prevalence. We conducted a systematic review of reported electrocardiogram (ECG) results for pediatric LVNC patients. EMBASE database query was performed, yielding 4531 articles related to LVNC between 1990 and December 2023. Patient age ranged from prenatal to 18 years of age. Qualitative analyses were performed to characterize individual arrhythmias, and summative interpretation of ECG evaluations was gathered for the entire cohort. Systematic review of 57 LVNC cases and ECG presentation revealed many waveform consistencies, including abnormal left ventricular, atrioventricular node, and interventricular septal patterns, and specifically a high incidence of Mobitz type II and Wolff-Parkinson-White waveforms. This review of ECG analysis reinforces the clinical and etiologic significance of pediatric LVNC. While LVNC in pediatric populations may not always present as acute clinical cases, further investigation into the electrophysiology of the disease supports the need for further evaluation and risk stratification for patients with suspected LVNC and/or ventricular arrhythmia.
Topics: Adolescent; Child; Child, Preschool; Female; Humans; Infant; Infant, Newborn; Arrhythmias, Cardiac; Electrocardiography; Isolated Noncompaction of the Ventricular Myocardium; Phenotype
PubMed: 38684446
DOI: 10.14814/phy2.16029 -
Heart Rhythm Mar 2024Implantable loop recorders (ILRs) are increasingly used to evaluate patients with unexplained syncope. Identification of all predictors of bradycardic syncope and...
BACKGROUND
Implantable loop recorders (ILRs) are increasingly used to evaluate patients with unexplained syncope. Identification of all predictors of bradycardic syncope and consequent permanent pacemaker (PPM) insertion is of substantial clinical interest as patients in the highest risk category may benefit from upfront pacemaker insertion.
OBJECTIVE
We performed a systematic review and meta-analysis to identify risk predictors for PPM insertion in ILR recipients with unexplained syncope.
METHODS
An electronic database search (MEDLINE, Embase, Scopus, Cochrane) was performed in June 2023. Studies evaluating ILR recipients with unexplained syncope and recording risk factors for eventual PPM insertion were included. A random effects model was used to calculate the pooled odds ratio (OR) for clinical and electrocardiographic characteristics with respect to future PPM requirement.
RESULTS
Eight studies evaluating 1007 ILR recipients were included; 268 patients (26.6%) underwent PPM insertion during study follow-up. PPM recipients were older (mean age, 70.2 ± 15.4 years vs 61.6 ± 19.7 years; P < .001). PR prolongation on baseline electrocardiography was a significant predictor of PPM requirement (pooled OR, 2.91; 95% confidence interval, 1.63-5.20). The presence of distal conduction system disease, encompassing any bundle branch or fascicular block, yielded a pooled OR of 2.88 for PPM insertion (95% confidence interval, 1.53-5.41). Injurious syncope and lack of syncopal prodrome were not significant predictors of PPM insertion. Sinus node dysfunction accounted for 62% of PPM insertions, whereas atrioventricular block accounted for 26%.
CONCLUSION
Approximately one-quarter of ILR recipients for unexplained syncope require eventual PPM insertion. Advancing age, PR prolongation, and distal conduction disease are the strongest predictors for PPM requirement.
PubMed: 38508296
DOI: 10.1016/j.hrthm.2024.03.038 -
Clinical Research in Cardiology :... Jun 2024Type 2 diabetes mellitus (T2DM) is associated with an increased risk of cardiac arrhythmias, which increases serious morbidity and mortality. Novel hypoglycemic drug... (Meta-Analysis)
Meta-Analysis
Sodium glucose cotransporter 2 inhibitors with cardiac arrhythmias in patients with type 2 diabetes mellitus: a systematic review and meta-analysis of randomized placebo-controlled trials.
BACKGROUND
Type 2 diabetes mellitus (T2DM) is associated with an increased risk of cardiac arrhythmias, which increases serious morbidity and mortality. Novel hypoglycemic drug sodium glucose cotransporter 2 (SGLT2) inhibitor has shown sufficient cardiovascular benefits in cardiovascular outcome trials.
OBJECTIVE
This systematic review and meta-analysis aimed to investigate the relationship between SGLT2 inhibitors and cardiac arrhythmias in patients with T2DM.
METHODS
We searched on PubMed and ClinicalTrials.gov for at least 24 weeks of randomized double-blind placebo-controlled trials involving T2DM subjects assigned to SGLT2 inhibitors or placebo as of May 5, 2023. Risk ratio (RR) with 95% confidence interval (CI) were used for binary variables. Primary outcomes included atrial arrhythmias, ventricular arrhythmias, bradyarrhythmias, cardiac arrest, and atrial fibrillation/atrial flutter. Secondary outcomes comprised atrial fibrillation, atrial flutter, ventricular fibrillation, ventricular tachycardia, atrioventricular block, and sinus node dysfunction.
RESULTS
We included 32 trials covering 60,594 T2DM patients (SGLT2 inhibitor 35,432; placebo 25,162; mean age 53.9 to 68.5 years). SGLT2 inhibitors significantly reduced the risk of atrial arrhythmias (RR 0.86; 95%CI 0.74-0.99; P = 0.04) or atrial fibrillation/flutter (RR 0.85; 95%CI 0.74-0.99; P = 0.03) compared to placebo; in subgroup analysis, SGLT2 inhibitors achieved a consistent effect with overall results in T2DM with high cardiovascular risk or follow-up > 1 year populations. There was no substantial evidence to suggest that SGLT2 inhibitors reduced the risk of ventricular arrhythmias (RR 0.94; 95%CI 0.71-1.26; P = 0.69) and cardiac arrest (RR 0.88; 95%CI 0.66-1.18; P = 0.39). A neutral effect of SGLT2 inhibitors on bradyarrhythmias was observed (RR 1.02; 95%CI 0.79-1.33; P = 0.85). SGLT2 inhibitors had no significant impact on all secondary outcomes compared to placebo, while it had borderline effect for atrial fibrillation.
CONCLUSION
SGLT2 inhibitors were associated with a reduced risk of atrial arrhythmias in patients with T2DM. Our results support the use of SGLT2 inhibitors in T2DM with high cardiovascular risk populations. We also recommend the long-term use of SGLT2 inhibitors to achieve further benefits.
Topics: Humans; Diabetes Mellitus, Type 2; Sodium-Glucose Transporter 2 Inhibitors; Randomized Controlled Trials as Topic; Arrhythmias, Cardiac
PubMed: 38353684
DOI: 10.1007/s00392-024-02386-6 -
Pediatric Cardiology Dec 2023Pacing indications in children are clearly defined, but whether an epicardial (EPI) or an endocardial (ENDO) pacemaker performs better remains to be elucidated. This... (Meta-Analysis)
Meta-Analysis Review
Pacing indications in children are clearly defined, but whether an epicardial (EPI) or an endocardial (ENDO) pacemaker performs better remains to be elucidated. This systematic review and meta-analysis aimed to directly compare the incidence of pacemaker (PM) lead-related complications, mortality, hemothorax and venous occlusion between EPI and ENDO in children with atrioventricular block (AVB) or sinus node dysfunction (SND). Literature search was conducted in MEDLINE (via PubMed), Scopus by ELSEVIER, Cochrane Central Register of Controlled Trials (CENTRAL), Web of Science, and OpenGrey databases until June 25, 2022. Random-effects meta-analyses were performed to assess the pacing method's effect on lead failure, threshold rise, post-implantation infection and battery depletion and secondarily on all-cause mortality, hemothorax and venous occlusion. Several sensitivity analyses were also performed. Of 22 studies initially retrieved, 18 were deemed eligible for systematic review and 15 for meta-analysis. Of 1348 pediatric patients that underwent EPI or ENDO implantation, 542 (40.2%) had a diagnosis of congenital heart disease (CHD). EPI was significantly associated with higher possibility of PM-lead failure [pooled odds ratio (pOR) 3.00, 95% confidence interval (CI) 2.05-4.39; I = 0%]; while possibility for threshold rise, post-implantation infection and battery depletion did not differ between the PM types. Regarding the secondary outcome, the mortality rates between EPI and ENDO did not differ. In sensitivity analyses the results were consistent results between the two PM types. The findings suggest that EPI may be associated with increased PM-lead failure compared to ENDO while threshold rise, infection, battery depletion and mortality rates did not differ.
Topics: Child; Humans; Atrioventricular Block; Sick Sinus Syndrome; Cardiac Pacing, Artificial; Hemothorax; Treatment Outcome; Pacemaker, Artificial; Postoperative Complications; Vascular Diseases
PubMed: 37480376
DOI: 10.1007/s00246-023-03213-x