Archives of Orthopaedic and Trauma... May 2024Rib fractures commonly occur in trauma patients with varying presentations. Though the literature in recent years has moved toward favoring more early intervention of... (Review)
Review
INTRODUCTION
Rib fractures commonly occur in trauma patients with varying presentations. Though the literature in recent years has moved toward favoring more early intervention of acute rib fractures, little has been reported on the matter of surgical fixation for symptomatic rib fracture nonunions.
MATERIALS AND METHODS
We performed a review of PubMed and Cochrane databases for articles published since 2000. Inclusion criteria were studies with greater than six months of follow-up, while case studies were excluded. A thorough analysis was performed on patient outcomes, complications reported, operative techniques utilized, and fixation systems used, among other parameters reported by the articles.
RESULTS
One hundred and thirty-nine studies resulted from our review, and a total of nine studies met our inclusion criteria with a combined total of 182 patients who underwent open reduction and internal fixation for symptomatic rib fracture nonunions. All studies reported a significant reduction of pain with increased satisfaction in the majority of patients. There were a total of 71 postoperative complications, the most common of which included surgical site infections, hardware failure, and hematoma. The most serious complications were insulting injury to the lung parenchyma or pleura; however, these were extremely rare based off the current literature. The use of bone grafting was common with eight of the nine studies mentioning the benefits of grafting.
CONCLUSION
Surgical stabilization of rib fracture nonunions appears to be an appropriate treatment alternative, and various techniques and approaches may be used with similar success. Further studies with higher level of evidence are recommended on the subject.
Topics: Humans; Rib Fractures; Fractures, Ununited; Fracture Fixation, Internal; Postoperative Complications; Bone Transplantation
PubMed: 38492065
DOI: 10.1007/s00402-024-05264-y -
Surgical Laparoscopy, Endoscopy &... Apr 2024Foreign bodies within the pleura and pancreas are infrequent, and the approaches to their treatment still a subject of debate. There is limited knowledge particularly...
BACKGROUND
Foreign bodies within the pleura and pancreas are infrequent, and the approaches to their treatment still a subject of debate. There is limited knowledge particularly regarding glass foreign bodies.
METHODS
We present a case involving large glass splinters in the pleura and pancreas, with an unknown entry point. In addition, a systematic review was conducted to explore entry hypotheses and management options.
RESULTS
In addition to our case, our review uncovered eight incidents of intrapleural glass, and another eight cases of glass in other intrathoracic areas. The fragments entered the body through impalement (81%), migrated through the diaphragm after impalement (6%), or caused transesophageal perforation (19%) following ingestion. Eight instances of glass inside the abdominal cavity were documented, with seven resulting from impalement injuries and one from transintestinal migration. There were no recorded instances of glass being discovered within the pancreas. Among the 41 nonglass intrapancreatic foreign bodies found, sewing needles (34%) and fish bones (46%) were the most common; following ingestion, they had migrated through either a transgastric or transduodenal perforation. In all these cases, how the foreign bodies were introduced was often poorly recalled by the patient. Many nonglass foreign bodies tend to become encapsulated by fibrous tissue, rendering them inert, though this is less common with glass. Glass has been reported to migrate through various tissues and cavities, sometimes with a significant delay spanning even decades. There are cases of intrapleural migration of glass causing hemothorax, pneumothorax, and heart and major blood vessels injury. For intrapleural glass fragment management, thoracoscopy proved to be effective in 5 reported cases, in addition to our patient. Most intrapancreatic nonglass foreign bodies tend to trigger pancreatitis and abscess formation, necessitating management ranging from laparoscopic procedures to subtotal pancreatectomy. There have been only four documented cases of intrapancreatic needles that remained asymptomatic with conservative management. There is no direct guidance from the existing literature regarding management of intrapancreatic glass foreign bodies. Consequently, our patient is under observation with regular follow-ups and has remained asymptomatic for the past 2 years.
CONCLUSIONS
Glass foreign bodies in the pleura are rare, and our report of an intrapancreatic glass fragment is the first of its kind. Impalement is the most likely method of introduction. As glass has significant migration and an ensuing complication potential, preventive removal of intrapleural loose glass should be considered. However, intrapancreatic glass fragment management remains uncertain.
Topics: Humans; Pleura; Foreign Bodies; Pancreas; Thoracoscopy; Pancreatectomy
PubMed: 38450728
DOI: 10.1097/SLE.0000000000001275 -
The Ultrasound Journal Jan 2024Pleural effusion is a fluid buildup in the pleural space that mostly result from congestive heart failure, bacterial pneumonia, malignancy, and pulmonary embolism. The... (Review)
Review
BACKGROUND
Pleural effusion is a fluid buildup in the pleural space that mostly result from congestive heart failure, bacterial pneumonia, malignancy, and pulmonary embolism. The diagnosis of this condition can be challenging as it presents symptoms that may overlap with other conditions; therefore, imaging diagnostic tools such as chest x-ray/radiograph (CXR), point-of-care ultrasound (POCUS), and computed tomography (CT) have been employed to make an accurate diagnosis. Although POCUS has high diagnostic accuracy, it is yet to be considered a first-line diagnostic tool as most physicians use radiography. Therefore, the current meta-analysis was designed to compare POCUS to chest radiography.
METHODS
n extended search for studies related to our topic was done on five electronic databases, including PubMed, Medline, Embase, Scopus, and Google Scholar. A quality assessment using the Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2) was performed on all eligible articles obtained from the databases. Moreover, the diagnostic accuracy of POCUS and CXR was performed using STATA 16 software.
RESULTS
Our search yielded 1642 articles, of which only 18 were eligible for inclusion and analysis. The pooled analysis showed that POCUS had a higher diagnostic accuracy compared to CXR (94.54% (95% CI 91.74-97.34) vs. 67.68% (95% CI 58.29-77.08) and 97.88% (95% CI 95.77-99.99) vs. 85.30% (95% CI 80.06-90.54) sensitivity and specificity, respectively). A subgroup analysis based on the position of patients during examinations showed that POCUS carried out in supine and upright positions had higher specificity than other POCUS positions (99%). In comparison, lateral decubitus CXR had higher sensitivity (96%) and specificity (99%) than the other CXR positions. Further subgroup analyses demonstrated that CXR had higher specificity in studies that included more than 100 patients (92.74% (95% CI 85.41-100). Moreover, CXR tends to have a higher diagnostic accuracy when other CXR positions are used as reference tests (93.38% (95% CI 86.30-100) and 98.51% (95% CI 94.65-100) sensitivity and specificity, respectively).
CONCLUSION
POCUS as an imaging modality has higher diagnostic accuracy than CXR in detecting pleural effusion. Moreover, the accuracy is still high even when performed by physicians with less POCUS training. Therefore, we suggest it is considered a first-line imaging tool for diagnosing pleural effusion at the patients' bedside.
PubMed: 38261109
DOI: 10.1186/s13089-023-00356-z -
Annals of the Royal College of Surgeons... Mar 2024There is a paucity of data on the optimal management of oesophagopleural fistula (OPF) following pneumonectomy. The current published literature is limited to case...
INTRODUCTION
There is a paucity of data on the optimal management of oesophagopleural fistula (OPF) following pneumonectomy. The current published literature is limited to case reports and small case series. Although rare, OPF can have a significant impact on both the morbidity and mortality of patients.
METHODS
Two cases of OPF managed at our institution were reported. A systematic review was then conducted in line with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidance concerning OPF following pneumonectomy. Demographic, operative and management data were analysed.
FINDINGS
Systematic review-identified data pertaining to 59 patients from 31 papers was collated. Median patient age was 59.5 years with pneumonectomy performed typically for malignancy (68%) or tuberculosis (19%). Median time from pneumonectomy to a diagnosis of OPF was 12.5 months. Twenty-five per cent of the patients had a synchronous bronchopleural fistula. Management of OPF in this setting is heterogenous. Conservative management was often reserved for asymptomatic or unfit patients. The remainder underwent endoscopic or surgical correction of the fistulae or a combination of the two with varying outcomes. Median follow-up was 18 months. All-cause mortality was 31% (18/59) with a median duration from pneumonectomy to death of 35 days (range 1-1,095).
CONCLUSIONS
Major heterogeneity of management for this rare complication hinders the introduction of standardised guidance of post-pneumonectomy OPF. Surgical and endoscopic intervention is feasible and can be successful in specialist centres. Adopting an multidisciplinary team approach involving both oesophagogastric and thoracic surgery teams and the introduction of a registry database of postoperative complications are likely to yield optimal outcomes.
Topics: Humans; Conservative Treatment; Databases, Factual; Fistula; Pneumonectomy; Postoperative Complications
PubMed: 37642088
DOI: 10.1308/rcsann.2023.0053