-
Circulation. Cardiovascular Imaging Jun 2024
PubMed: 38941554
DOI: 10.1161/CIRCIMAGING.124.016668 -
Medicine Jun 2024Complete dislodgement of a mechanical valve is extremely uncommon as a long-term issue after getting a substitute mitral valve, and this report details an incident of...
RATIONALE
Complete dislodgement of a mechanical valve is extremely uncommon as a long-term issue after getting a substitute mitral valve, and this report details an incident of complete detachment of a mechanical valve.
PATIENT CONCERNS
A 50-year-old woman, who underwent mitral mechanical valve replacement 2 decades earlier at another facility, was urgently admitted due to sudden cardiogenic shock.
DIAGNOSES
Transthoracic echocardiograms revealed severe malfunction of the mitral valve prosthesis, characterized by significant mitral regurgitation and moderate pulmonary hypertension. Following the insertion of extracorporeal membrane oxygenation and an intra-aortic balloon pump, the hemodynamics stabilized. Coronary angiography displayed the prosthetic mitral valve ring and leaflet floating in the left atrium, as confirmed by preoperative real-time 3-dimensional transesophageal echocardiography. A complete separation of the prosthetic ring and leaflet from the suture ring was observed.
INTERVENTIONS
The patient promptly underwent bioprosthetic mitral valve replacement.
OUTCOMES
The patient's postoperative course was uneventful, leading to discharge in good condition.
LESSONS
A crucial aspect is comprehending the structure of the prosthetic valve itself. The use of transthoracic echocardiography and real-time 3-dimensional transesophageal echocardiography provides additional structural and functional details, enhancing support for potential life-saving interventions. Echocardiography plays a significant role in evaluating the morphology and function of prosthetic valves.
Topics: Humans; Female; Middle Aged; Heart Valve Prosthesis; Mitral Valve Insufficiency; Prosthesis Failure; Mitral Valve; Heart Valve Prosthesis Implantation; Echocardiography, Transesophageal; Shock, Cardiogenic; Echocardiography, Three-Dimensional
PubMed: 38941392
DOI: 10.1097/MD.0000000000038612 -
JACC. Advances Oct 2023Heart failure (HF) is a leading cause of readmission after cardiac surgery, yet risk factors for HF readmission after cardiac surgery remain poorly characterized.
BACKGROUND
Heart failure (HF) is a leading cause of readmission after cardiac surgery, yet risk factors for HF readmission after cardiac surgery remain poorly characterized.
OBJECTIVES
This study aimed to identify risk factors associated with 30-day HF-specific readmissions after cardiac surgery using a national database.
METHODS
We queried the 2016 to 2018 National Readmissions Database to identify U.S. patients who underwent coronary artery bypass grafting (CABG), mitral valve repair/replacement, and/or aortic valve repair/replacement. Exclusion criteria included history of ventricular assist device or heart transplant, dialysis-dependent renal insufficiency, and death during index admission. Clinical variables were defined using International Classification of Diseases-10th Revision codes. The primary outcome was a 30-day readmission for HF following discharge. Multivariable logistic regression was used to account for relevant clinical and demographic covariates and identify independent risk factors for HF readmissions following cardiac surgery.
RESULTS
Our study included 394,050 patients who underwent cardiac surgery (mean age 66 ± 12 years, 63% isolated CABG, 27% isolated valve, 11% CABG + valve). Of these patients, 7,318 were readmitted within 30 days of discharge for a principal diagnosis of HF. Independent risk factors of HF-specific readmission included older age, female sex, prolonged length of stay, comorbid congestive HF, nondialysis dependent chronic kidney disease, chronic obstructive pulmonary disease, chronic liver disease, obesity, atrial fibrillation, and acute kidney injury. Prior CABG was marginally protective for HF-specific readmission.
CONCLUSIONS
Using a national registry, we identified risk factors associated with HF readmission after cardiac surgery. Further analysis of these risk factors and their association with HF readmission is warranted.
PubMed: 38938350
DOI: 10.1016/j.jacadv.2023.100599 -
Journal of Cardiothoracic Surgery Jun 2024Intra-cardiac thrombosis is a potentially devastating complication of extracorporeal membrane oxygenation (ECMO) mechanical circulatory support. We present here a...
Intra-cardiac thrombosis is a potentially devastating complication of extracorporeal membrane oxygenation (ECMO) mechanical circulatory support. We present here a patient who suffered complete thrombosis of a fresh mitral prosthesis and left atrium in the setting of ECMO with aortic insufficiency who was treated with repeat valve replacement and thrombectomy. To our knowledge, she is the only patient in the reported literature to have survived this complication.
Topics: Female; Humans; Bioprosthesis; Extracorporeal Membrane Oxygenation; Heart Atria; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Mitral Valve; Thrombectomy; Thrombosis; Aged
PubMed: 38926882
DOI: 10.1186/s13019-024-02916-3 -
Journal of Cardiothoracic Surgery Jun 2024For acute type A aortic dissection involving the aortic root with root diameter no more than 45 mm, there are various aortic root repair techniques. In this study, a...
BACKGROUND
For acute type A aortic dissection involving the aortic root with root diameter no more than 45 mm, there are various aortic root repair techniques. In this study, a novel surgical technique using a pericardial autograft for aortic root repair was introduced. We described its surgical steps in detail and compare its clinical outcomes with direct suture technique.
METHODS
Between July 2017 and August 2022, 95 patients with acute type A aortic dissection who underwent aortic root repair were enrolled, including aortic root repair using pericardial autograft (group A, n = 49) or direct suture (group B, n = 46). The patient's clinical data were retrospectively analyzed, and a 5-year follow-up was conducted.
RESULTS
The 30-day mortality, re-exploration for bleeding, postoperative new-onset renal failure requiring continuous renal replacement therapy, stroke, and paraplegia occurred in 3%, 4%, 11%, 5%, and 2% of the overall patients, respectively. There was no significant difference in the 30-day mortality and complication rate between the two groups. The 30-day mortality and re-exploration for bleeding marked the primary endpoint events. Logistic regression analysis indicated that there was a significant correlation between the primary endpoint events and surgical technique (odds ratio, 0.002; 95% confidence interval, 0-0.159; P = 0.026). The aortic valve insufficiency of the two groups were significantly improved after operation (group A, P < 0.001; group B, P < 0.001). During follow-up, there was no significant difference in short-term survival between the two groups after surgery (log-rank P = 0.75), and all patients were free from reoperation for aortic disease.
CONCLUSIONS
Patients who underwent aortic root repair using pericardial autograft tended to have reduced 30-day mortality and a lower risk of re-exploration for bleeding. Using pericardial autograft for aortic root repair is a safe and useful approach for patients with acute type A aortic dissection involving the aortic root.
Topics: Humans; Aortic Dissection; Male; Female; Retrospective Studies; Middle Aged; Pericardium; Treatment Outcome; Autografts; Aortic Aneurysm, Thoracic; Aged; Acute Disease; Postoperative Complications; Blood Vessel Prosthesis Implantation; Transplantation, Autologous; Follow-Up Studies
PubMed: 38926836
DOI: 10.1186/s13019-024-02909-2 -
Proceedings (Baylor University. Medical... 2024Among patients with bicuspid aortic valves (BAV) who are potential candidates for valve-sparing root replacement (VSRR), the long-term durability of this technique is...
BACKGROUND
Among patients with bicuspid aortic valves (BAV) who are potential candidates for valve-sparing root replacement (VSRR), the long-term durability of this technique is not well understood. This study aimed to compare the clinical and echocardiographic outcomes of VSRR in those with BAV and tricuspid aortic valve (TAV) morphology.
METHODS
This was a retrospective analysis of patients who underwent VSRR between 2007 and 2021 at a single center. Kaplan-Meier and log-rank analysis were used to estimate and compare freedom from mortality, progression to >2+ aortic insufficiency (AI), and reoperation between groups (BAV vs TAV). Preoperative and postoperative echocardiographic data were collected and assessed for temporal changes in mixed-effect models.
RESULTS
A total of 185 patients (BAV, n = 52, 28.1%; TAV, n = 133, 71.9%) underwent VSRR. At baseline, BAV patients were younger (42.4 ± 11.6 vs 52.3 ± 12.6 years; < 0.01) and had more severe AI (47.9% vs 27.0%; = 0.02). Average cardiopulmonary bypass and cross-clamp times were similar. There were no differences in rates of postoperative complications, intensive care unit or hospital days, or 30-day readmission. TAV patients' 1-, 5-, and 8-year survival rates were 99.2% [95% CI 97.8-100], 96.7% [93.5-99.9%], and 92.2% [85.6-99.3%], respectively. Overall, there were no differences between groups regarding freedom from mortality ( = 0.18), reoperation ( = 0.51), or recurrent >2+ AI ( = 0.97). .
CONCLUSIONS
VSRR can be safely performed on patients with BAV and TAV morphology, yielding similar midterm freedom from mortality, recurrent >2+ AI, and reoperation. This technique should be considered in carefully selected patients with aortic root pathology and BAV anatomy when performed at experienced centers.
PubMed: 38910820
DOI: 10.1080/08998280.2024.2346445 -
The International Journal of... Jun 2024Percutaneous closure of the left atrial appendage may be indicated in patients with contraindications to anticoagulation therapy, for example, after recurrent...
Percutaneous closure of the left atrial appendage may be indicated in patients with contraindications to anticoagulation therapy, for example, after recurrent gastrointestinal bleeding. It is an effective and safe procedure but is not without complications. We present a patient who presented with severe aortic insufficiency due to migration of the left atrial appendage closure device, which required urgent cardiac surgery for its removal.
PubMed: 38904848
DOI: 10.1007/s10554-024-03136-5 -
Cureus May 2024We present a unique clinical scenario of a 58-year-old male with a past medical history of hypertension who initially presented with chest pain and was ruled in for...
We present a unique clinical scenario of a 58-year-old male with a past medical history of hypertension who initially presented with chest pain and was ruled in for non-ST elevation myocardial infarction (NSTEMI) but rapidly developed respiratory failure secondary to aortic insufficiency complicated by cardiogenic shock (CS), attributed to aortic valve prolapse. Intriguingly, the patient had a normal ECG on presentation, underscoring the dynamic nature of valvular pathology. The development of CS highlights the importance of early recognition, prompt diagnosis, and interdisciplinary management in such complex cases.
PubMed: 38887341
DOI: 10.7759/cureus.60562 -
Computer Methods and Programs in... Jun 2024The implantation of ventricular assist devices (VADs) has become an important treatment option for patients with heart failure. Aortic valve insufficiency is a common...
BACKGROUND AND OBJECTIVE
The implantation of ventricular assist devices (VADs) has become an important treatment option for patients with heart failure. Aortic valve insufficiency is a common complication caused by VADs implantation. Currently, there is very little quantitative research on the effects of transcatheter micro VADs or the intervention pumps on the aortic valves.
METHODS
In this study, the multi-component arbitrary Lagrange-Eulerian method is used to perform fluid-structure interaction simulations of the aortic valve model with and without intervention pumps. The effects of intervention pumps implantation on the opening area of the aortic valves, the stress distribution, and the flow characteristics are quantitatively analyzed. Statistical results are consistent with clinical guidelines and experiments.
RESULTS
The implantation of intervention pumps leads to the valve insufficiency and causes weak valve regurgitation. In the short-term treatment, the valve regurgitation is within a controllable range. The distribution and variation of stress on the leaflets are also affected by intervention pumps. The whirling flow in the flow direction affects the closing speed of the aortic valves and optimizes the stress distribution of the valves. In the models with whirling flow, the effects of intervention pumps implantation on valve motion and stress distribution differ from those without whirling flow. However, the valve insufficiency and valve regurgitation caused by intervention pumps still exist in the models with whirling flow. Conventional artificial bioprosthetic valves have limited effectiveness in treating the valve diseases caused by intervention pumps implantation.
CONCLUSIONS
This study quantitatively investigates the impact of intervention pumps on the aortic valves, and investigates the effect of blood rotation on the valve behavior, which is a gap in previous research. We suggest that in the short-term treatment, the implantation of intervention pumps has limited impact on aortic valves, caution should be exercised against valve regurgitation issues caused by intervention pumps.
PubMed: 38878358
DOI: 10.1016/j.cmpb.2024.108270 -
Journal of Vascular Surgery Cases and... Aug 2024We present a rare case of eosinophilic granulomatosis with polyangiitis (EGPA), involving a 26-year-old woman with a history of asthma and nasal polyps. The patient...
We present a rare case of eosinophilic granulomatosis with polyangiitis (EGPA), involving a 26-year-old woman with a history of asthma and nasal polyps. The patient presented with acute aortoiliac thrombosis and mitral insufficiency, which was successfully treated with thrombolysis, aortic thromboendarterectomy, and valve replacement. Peripheral hypereosinophilia with eosinophilic infiltration of the heart led to the diagnosis of antineutrophilic cytoplasmic antibody-negative EGPA. Treatment with prednisone and mepolizumab was started, resulting in a positive outcome. This case showcases an unusual manifestation of EGPA with large size vessel involvement and requiring surgical and pharmacological treatment. It also highlights the importance of early detection for timely intervention and an improved prognosis.
PubMed: 38873328
DOI: 10.1016/j.jvscit.2024.101515