Ghana Medical Journal Sep 2023To document the location, size, and multiplicity of intracranial aneurysms in Ghanaians who have undergone digital subtraction angiography (DSA) at a single centre in... (Observational Study)
Observational Study
OBJECTIVE
To document the location, size, and multiplicity of intracranial aneurysms in Ghanaians who have undergone digital subtraction angiography (DSA) at a single centre in Accra, Ghana.
DESIGN
We conducted a retrospective observational review of the medical records of all patients diagnosed with intracranial aneurysms on DSA.
SETTING
Patients' medical records at Euracare Advanced Diagnostic and Heart Centre were reviewed between March 2018 and March 2020.
PARTICIPANTS
Thirty-one patients were identified with various intracranial aneurysms (IAs) within the study period. Patients' ages, sex, and types of IAs were extracted using a checklist and analysed using Microsoft Excel for Windows 2016.
INTERVENTIONS
None.
MAIN OUTCOME MEASURES
The prevalence of types and distribution of intracranial aneurysms.
RESULTS
The age range of the patients was 26-76 years, with a mean age of 45.5±14.3 years. The mean age of men and women with IA was 45.5 ±15.9 years and 46.7 51.3±12.9 years, respectively. The most common IAs were located in the posterior communicating artery (PCOM) at 54.8% (95%CI: 36.0, 72.7), followed by the anterior communicating (ACOM), which constituted 32.3% (95%CI: 16.7, 51.4). The majority, 89.2% (33/37) of these aneurysms were less than 7mm in diameter. Single aneurysms were present in 25 (80.6%).
CONCLUSION
The most common IAs were found in the PCOM and ACOM, and IAs tend to rupture at a younger age and smaller size among the Ghanaian adults examined. Early detection and treatment of IAs less than 7mm in diameter is recommended.
FUNDING
None declared.
Topics: Humans; Intracranial Aneurysm; Ghana; Female; Male; Adult; Middle Aged; Retrospective Studies; Aged; Angiography, Digital Subtraction; Prevalence
PubMed: 38957670
DOI: 10.4314/gmj.v57i3.13 -
Burns & Trauma 2024
PubMed: 38957663
DOI: 10.1093/burnst/tkae032 -
Cureus Jun 2024This review aims to explore the potential of artificial intelligence (AI) in coronary CT angiography (CCTA), a key tool for diagnosing coronary artery disease (CAD).... (Review)
Review
This review aims to explore the potential of artificial intelligence (AI) in coronary CT angiography (CCTA), a key tool for diagnosing coronary artery disease (CAD). Because CAD is still a major cause of death worldwide, effective and accurate diagnostic methods are required to identify and manage the condition. CCTA certainly is a noninvasive alternative for diagnosing CAD, but it requires a large amount of data as input. We intend to discuss the idea of incorporating AI into CCTA, which enhances its diagnostic accuracy and operational efficiency. Using such AI technologies as machine learning (ML) and deep learning (DL) tools, CCTA images are automated to perfection and the analysis is significantly refined. It enables the characterization of a plaque, assesses the severity of the stenosis, and makes more accurate risk stratifications than traditional methods, with pinpoint accuracy. Automating routine tasks through AI-driven CCTA will reduce the radiologists' workload considerably, which is a standard benefit of such technologies. More importantly, it would enable radiologists to allocate more time and expertise to complex cases, thereby improving overall patient care. However, the field of AI in CCTA is not without its challenges, which include data protection, algorithm transparency, as well as criteria for standardization encoding. Despite such obstacles, it appears that the integration of AI technology into CCTA in the future holds great promise for keeping CAD itself in check, thereby aiding the fight against this disease and begetting better clinical outcomes and more optimized modes of healthcare. Future research on AI algorithms for CCTA, making ethical use of AI, and thereby overcoming the technical and clinical barriers to widespread adoption of this new tool, will hopefully pave the way for profound AI-driven transformations in healthcare.
PubMed: 38957241
DOI: 10.7759/cureus.61523 -
Korean Circulation Journal Jun 2024Angiographic assessment of coronary stenosis severity using quantitative coronary angiography (QCA) is often inconsistent with that based on fractional flow reserve...
Discordance Between Angiographic Assessment and Fractional Flow Reserve or Intravascular Ultrasound in Intermediate Coronary Lesions: A Post-hoc Analysis of the FLAVOUR Trial.
BACKGROUND AND OBJECTIVES
Angiographic assessment of coronary stenosis severity using quantitative coronary angiography (QCA) is often inconsistent with that based on fractional flow reserve (FFR) or intravascular ultrasound (IVUS). We investigated the incidence of discrepancies between QCA and FFR or IVUS, and the outcomes of FFR- and IVUS-guided strategies in discordant coronary lesions.
METHODS
This study was a post-hoc analysis of the FLAVOUR study. We used a QCA-derived diameter stenosis (DS) of 60% or greater, the highest tertile, to classify coronary lesions as concordant or discordant with FFR or IVUS criteria for percutaneous coronary intervention (PCI). The patient-oriented composite outcome (POCO) was defined as a composite of death, myocardial infarction, or revascularization at 24 months.
RESULTS
The discordance rate between QCA and FFR or IVUS was 30.2% (n=551). The QCA-FFR discordance rate was numerically lower than the QCA-IVUS discordance rate (28.2% vs. 32.4%, p=0.050). In 200 patients with ≥60% DS, PCI was deferred according to negative FFR (n=141) and negative IVUS (n=59) (15.3% vs. 6.5%, p<0.001). The POCO incidence was comparable between the FFR- and IVUS-guided deferral strategies (5.9% vs. 3.4%, p=0.479). Conversely, 351 patients with DS <60% underwent PCI according to positive FFR (n=118) and positive IVUS (n=233) (12.8% vs. 25.9%, p<0.001). FFR- and IVUS-guided PCI did not differ in the incidence of POCO (9.5% vs. 6.5%, p=0.294).
CONCLUSIONS
The proportion of QCA-FFR or IVUS discordance was approximately one third for intermediate coronary lesions. FFR- or IVUS-guided strategies for these lesions were comparable with respect to POCO at 24 months.
TRIAL REGISTRATION
ClinicalTrials.gov Identifier: NCT02673424.
PubMed: 38956940
DOI: 10.4070/kcj.2024.0046 -
Korean Circulation Journal Jun 2024The recent developments in chronic thromboembolic pulmonary hypertension (CTEPH) are emphasizing the multidisciplinary team. We report on the changes in clinical...
BACKGROUND AND OBJECTIVES
The recent developments in chronic thromboembolic pulmonary hypertension (CTEPH) are emphasizing the multidisciplinary team. We report on the changes in clinical practice following the development of a multidisciplinary team, based on our 7 years of experience.
METHODS
Multidisciplinary team was established in 2015 offering both balloon pulmonary angioplasty (BPA) and pulmonary endarterectomy (PEA) with technical upgrades by internal and external expertise. For operable cases, PEA was recommended as the primary treatment modality, followed by pulmonary angiography and right heart catheterization after 6 months to evaluate treatment effect and identify patients requiring further BPA. For patients with inoperable anatomy or high surgical risk, BPA was recommended as the initial treatment modality. Patient data and clinical outcomes were closely monitored.
RESULTS
The number of CTEPH treatments rapidly increased and postoperative survival improved after team development. Before the team, 38 patients were treated by PEA for 18 years; however, 125 patients were treated by PEA or BPA after the team for 7 years. The number of PEA performed was 64 and that of BPA 342 sessions. World Health Organization functional class I or II was achieved in 93% of patients. The patients treated with PEA was younger, male dominant, higher pulmonary artery pressure, and smaller cardiac index, than BPA-only patients. In-hospital death after PEA was only 1 case and none after BPA.
CONCLUSIONS
The balanced development of BPA and PEA through a multidisciplinary team approach proved synergistic in increasing the number of actively treated CTEPH patients and improving clinical outcomes.
PubMed: 38956937
DOI: 10.4070/kcj.2024.0021 -
Ophthalmic Genetics Jul 2024To explore patterns of disease expression in Alagille syndrome (ALGS).
PURPOSE
To explore patterns of disease expression in Alagille syndrome (ALGS).
METHODS
Patients underwent ophthalmic examination, optical coherence tomography (OCT) imaging, fundus intravenous fluorescein angiography (IVFA), perimetry and full-field electroretinograms (ffERGs). An adult ALGS patient had multimodal imaging and specialized perimetry.
RESULTS
The proband (P1) had a heterozygous pathogenic variant in ; (p.Gln410Ter) and was incidentally diagnosed at age 7 with a superficial retinal hemorrhage, vascular tortuosity, and midperipheral pigmentary changes. The hemorrhage recurred 15 months later. Her monozygotic twin sister (P2) had a retinal hemorrhage at the same location at age 11. Visual acuities for both patients were 20/30 in each eye. IVFA was normal. OCT showed thinning of the outer nuclear in the peripapillary retina. A ffERG showed normal cone-mediated responses in P1 (rod-mediated ERGs not documented), normal ffERGs in P2. Coagulation and liver function were normal. An unrelated 42-year-old woman with a de-novo pathogenic variant (p. Gly386Arg) in showed a similar pigmentary retinopathy and hepatic vascular anomalies; rod and cone function was normal across large expanses of structurally normal retina that sharply transitioned to a blind atrophic peripheral retina.
CONCLUSION
Nearly identical recurrent intraretinal hemorrhages in monozygotic twins with ALGS suggest a shared subclinical microvascular abnormality. We hypothesize that the presence of large areas of functionally and structurally intact retina surrounded by severe chorioretinal degeneration, is against a predominant involvement of JAG1 in the function of the neurosensory retina, and that instead, primary abnormalities of chorioretinal vascular development and/or homeostasis may drive the peculiar phenotypes.
PubMed: 38956866
DOI: 10.1080/13816810.2024.2362214 -
BMC Medical Imaging Jul 2024To examine whether there is a significant difference in image quality between the deep learning reconstruction (DLR [AiCE, Advanced Intelligent Clear-IQ Engine]) and... (Comparative Study)
Comparative Study
A comparative analysis of deep learning and hybrid iterative reconstruction algorithms with contrast-enhancement-boost post-processing on the image quality of indirect computed tomography venography of the lower extremities.
PURPOSE
To examine whether there is a significant difference in image quality between the deep learning reconstruction (DLR [AiCE, Advanced Intelligent Clear-IQ Engine]) and hybrid iterative reconstruction (HIR [AIDR 3D, adaptive iterative dose reduction three dimensional]) algorithms on the conventional enhanced and CE-boost (contrast-enhancement-boost) images of indirect computed tomography venography (CTV) of lower extremities.
MATERIALS AND METHODS
In this retrospective study, seventy patients who underwent CTV from June 2021 to October 2022 to assess deep vein thrombosis and varicose veins were included. Unenhanced and enhanced images were reconstructed for AIDR 3D and AiCE, AIDR 3D-boost and AiCE-boost images were obtained using subtraction software. Objective and subjective image qualities were assessed, and radiation doses were recorded.
RESULTS
The CT values of the inferior vena cava (IVC), femoral vein ( FV), and popliteal vein (PV) in the CE-boost images were approximately 1.3 (1.31-1.36) times higher than in those of the enhanced images. There were no significant differences in mean CT values of IVC, FV, and PV between AIDR 3D and AiCE, AIDR 3D-boost and AiCE-boost images. Noise in AiCE, AiCE-boost images was significantly lower than in AIDR 3D and AIDR 3D-boost images ( P < 0.05). The SNR (signal-to-noise ratio), CNR (contrast-to-noise ratio), and subjective scores of AiCE-boost images were the highest among 4 groups, surpassing AiCE, AIDR 3D, and AIDR 3D-boost images (all P < 0.05).
CONCLUSION
In indirect CTV of the lower extremities images, DLR with the CE-boost technique could decrease the image noise and improve the CT values, SNR, CNR, and subjective image scores. AiCE-boost images received the highest subjective image quality score and were more readily accepted by radiologists.
Topics: Humans; Deep Learning; Male; Retrospective Studies; Female; Middle Aged; Lower Extremity; Aged; Phlebography; Adult; Contrast Media; Algorithms; Venous Thrombosis; Tomography, X-Ray Computed; Radiographic Image Interpretation, Computer-Assisted; Popliteal Vein; Varicose Veins; Vena Cava, Inferior; Femoral Vein; Radiation Dosage; Computed Tomography Angiography; Aged, 80 and over; Radiographic Image Enhancement
PubMed: 38956583
DOI: 10.1186/s12880-024-01342-0 -
BMC Medical Imaging Jul 2024The detection and management of intracranial aneurysms (IAs) are vital to prevent life-threatening complications like subarachnoid hemorrhage (SAH). Artificial...
BACKGROUND
The detection and management of intracranial aneurysms (IAs) are vital to prevent life-threatening complications like subarachnoid hemorrhage (SAH). Artificial Intelligence (AI) can analyze medical images, like CTA or MRA, spotting nuances possibly overlooked by humans. Early detection facilitates timely interventions and improved outcomes. Moreover, AI algorithms offer quantitative data on aneurysm attributes, aiding in long-term monitoring and assessing rupture risks.
METHODS
We screened four databases (PubMed, Web of Science, IEEE and Scopus) for studies using artificial intelligence algorithms to identify IA. Based on algorithmic methodologies, we categorized them into classification, segmentation, detection and combined, and then their merits and shortcomings are compared. Subsequently, we elucidate potential challenges that contemporary algorithms might encounter within real-world clinical diagnostic contexts. Then we outline prospective research trajectories and underscore key concerns in this evolving field.
RESULTS
Forty-seven studies of IA recognition based on AI were included based on search and screening criteria. The retrospective results represent that current studies can identify IA in different modal images and predict their risk of rupture and blockage. In clinical diagnosis, AI can effectively improve the diagnostic accuracy of IA and reduce missed detection and false positives.
CONCLUSIONS
The AI algorithm can detect unobtrusive IA more accurately in communicating arteries and cavernous sinus arteries to avoid further expansion. In addition, analyzing aneurysm rupture and blockage before and after surgery can help doctors plan treatment and reduce the uncertainties in the treatment process.
Topics: Intracranial Aneurysm; Humans; Artificial Intelligence; Algorithms; Magnetic Resonance Angiography
PubMed: 38956538
DOI: 10.1186/s12880-024-01347-9 -
BMC Cardiovascular Disorders Jul 2024The anticancer drug of tyrosine kinase-inhibitors (TKIs) has significantly improved the prognosis of patients with specific leukemia but has also increased the risk of...
The anticancer drug of tyrosine kinase-inhibitors (TKIs) has significantly improved the prognosis of patients with specific leukemia but has also increased the risk of organ adverse reactions. Herein, we present a case of a patient diagnosed with myeloproliferative neoplasms who experienced recurrent chest pain after receiving treatment with Olverembatinib. Electrocardiography and coronary angiography confirmed the diagnosis of myocardial infarction with non-obstructive coronary arteries. This case serves as a reminder for clinicians to pay more attention and actively prevent the cardiac adverse reactions of TKIs when using such medications.
Topics: Humans; Protein Kinase Inhibitors; Coronary Angiography; Electrocardiography; Antineoplastic Agents; Treatment Outcome; Male; Myocardial Infarction; Cardiotoxicity; Middle Aged
PubMed: 38956489
DOI: 10.1186/s12872-024-04011-w -
BMC Medical Imaging Jul 2024The image quality of computed tomography angiography (CTA) images following endovascular aneurysm repair (EVAR) is not satisfactory, since artifacts resulting from... (Comparative Study)
Comparative Study
BACKGROUND
The image quality of computed tomography angiography (CTA) images following endovascular aneurysm repair (EVAR) is not satisfactory, since artifacts resulting from metallic implants obstruct the clear depiction of stent and isolation lumens, and also adjacent soft tissues. However, current techniques to reduce these artifacts still need further advancements due to higher radiation doses, longer processing times and so on. Thus, the aim of this study is to assess the impact of utilizing Single-Energy Metal Artifact Reduction (SEMAR) alongside a novel deep learning image reconstruction technique, known as the Advanced Intelligent Clear-IQ Engine (AiCE), on image quality of CTA follow-ups conducted after EVAR.
MATERIALS
This retrospective study included 47 patients (mean age ± standard deviation: 68.6 ± 7.8 years; 37 males) who underwent CTA examinations following EVAR. Images were reconstructed using four different methods: hybrid iterative reconstruction (HIR), AiCE, the combination of HIR and SEMAR (HIR + SEMAR), and the combination of AiCE and SEMAR (AiCE + SEMAR). Two radiologists, blinded to the reconstruction techniques, independently evaluated the images. Quantitative assessments included measurements of image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the longest length of artifacts (AL), and artifact index (AI). These parameters were subsequently compared across different reconstruction methods.
RESULTS
The subjective results indicated that AiCE + SEMAR performed the best in terms of image quality. The mean image noise intensity was significantly lower in the AiCE + SEMAR group (25.35 ± 6.51 HU) than in the HIR (47.77 ± 8.76 HU), AiCE (42.93 ± 10.61 HU), and HIR + SEMAR (30.34 ± 4.87 HU) groups (p < 0.001). Additionally, AiCE + SEMAR exhibited the highest SNRs and CNRs, as well as the lowest AIs and ALs. Importantly, endoleaks and thrombi were most clearly visualized using AiCE + SEMAR.
CONCLUSIONS
In comparison to other reconstruction methods, the combination of AiCE + SEMAR demonstrates superior image quality, thereby enhancing the detection capabilities and diagnostic confidence of potential complications such as early minor endleaks and thrombi following EVAR. This improvement in image quality could lead to more accurate diagnoses and better patient outcomes.
Topics: Humans; Retrospective Studies; Female; Computed Tomography Angiography; Aged; Male; Endovascular Procedures; Artifacts; Middle Aged; Aortic Aneurysm, Abdominal; Deep Learning; Radiographic Image Interpretation, Computer-Assisted; Stents; Endovascular Aneurysm Repair
PubMed: 38956470
DOI: 10.1186/s12880-024-01343-z