-
The Journal of Vascular Access Jun 2024Peripherally inserted central catheters (PICCs) are frequently utilized for extended intravenous treatments. However, complications such as incorrect placement into the...
BACKGROUND
Peripherally inserted central catheters (PICCs) are frequently utilized for extended intravenous treatments. However, complications such as incorrect placement into the azygos vein can result in significant health issues. A thorough understanding of these aspects is crucial to enhance the safety and effectiveness of PICC procedures, thereby improving patient care outcomes.
METHODS
The research was conducted on a cohort of 12 patients who experienced PICC malposition into the azygos vein. Systematically reviewed information on classification, imaging manifestations, potential influencing factors, and methods for identification, prevention, and management.
RESULTS
The analysis uncovered two PICC malposition classifications within the azygos vein, each with unique imaging characteristics. It also pinpointed several factors influencing malposition, offering valuable insight into potential risks. Moreover, it established effective detection methods, underscoring the significance of imaging techniques. Additionally, it outlined strategies for preventing and managing PICC malposition in the azygos vein, enhancing overall comprehension of the issue.
CONCLUSIONS
The findings emphasize the importance of taking a proactive stance to avoid malposition and stress the necessity of prompt and precise intervention when malposition does happen, thereby enhancing the safety and effectiveness of PICC processes.
PubMed: 38869031
DOI: 10.1177/11297298241258802 -
Plastic and Reconstructive Surgery.... Jun 2024Patients with previous breast augmentation may need implant removal for mechanical complications or other causes. After prosthesis removal, the residual parenchyma can...
BACKGROUND
Patients with previous breast augmentation may need implant removal for mechanical complications or other causes. After prosthesis removal, the residual parenchyma can be reshaped through a mastopexy with rearrangement of breast tissue. Several techniques have been described in the literature, but none of them can be considered the gold standard. In this study, we present our preliminary experience in breast tissue rearranging after implant removal through a novel technique: the "octopus head" dermoglandular flap.
METHODS
From January 2019 to October 2022, nine patients (18 breasts) underwent implant removal and simultaneous breast remodeling with the tissue obtained from the dermoglandular excess of the breast and shaped like an octopus head. Patient's demographic and clinical characteristics, postoperative complications, and patient-reported satisfaction were recorded.
RESULTS
Mean age was 46.7 years. Body mass index ranged between 22.5 and 27.6 kg per m. The majority of patients had moderate ptosis (67%). Breast implants were removed due to bilateral capsular contracture (n = 3), unilateral implant rupture with contralateral capsular contracture (n = 2), bilateral implant rupture (n = 3), and unilateral periprosthetic seroma (n = 1). We observed two minor complications: one postoperative hemorrhage with subsequent hematoma that was managed conservatively, and one nipple-areola complex malposition that underwent revision surgery. All patients were satisfied with the aesthetic and functional result.
CONCLUSIONS
The octopus head dermoglandular flap has proved to be a safe and reliable option for breast tissue rearranging after implant removal, providing a good and stable cosmetic result, a low complication rate, and high patient-reported satisfaction.
PubMed: 38868620
DOI: 10.1097/GOX.0000000000005882 -
Orthopaedic Journal of Sports Medicine Jun 2024While the biomechanical properties of the native medial patellofemoral ligament (MPFL) have been well studied, there is no comprehensive summary of the biomechanics of... (Review)
Review
BACKGROUND
While the biomechanical properties of the native medial patellofemoral ligament (MPFL) have been well studied, there is no comprehensive summary of the biomechanics of MPFL reconstruction (MPFLR). An accurate understanding of the kinematic properties and functional behavior of current techniques used in MPFLR is imperative to restoring native biomechanics and improving outcomes.
PURPOSE
To provide a comprehensive review of the biomechanical effects of variations in MPFLR, specifically to determine the effect of graft choice and reconstruction technique.
STUDY DESIGN
Systematic review.
METHODS
A systematic review was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. A total of 32 studies met inclusion criteria: (1) using ≥8 human cadaveric specimens, (2) reporting on a component of MPFLR, and (3) having multiple comparison groups.
RESULTS
Gracilis, semitendinosus, and quadriceps grafts demonstrated an ultimate load to failure (N) of 206.2, 102.8, and 190.0 to 205.0 and stiffness (N/mm) of 20.4, 8.5, and 21.4 to 33.6, respectively. Single-bundle and double-bundle techniques produced an ultimate load to failure (N) of 171 and 213 and stiffness (N/mm) of 13.9 and 17.1, respectively. Anchors placed centrally and superomedially in the patella produced the smallest degree of length changes throughout range of motion in contrast to anchors placed more proximally. Sutures, suture anchors, and transosseous tunnels all produced similar ultimate load to failure, stiffness, and elongation data. Femoral tunnel malpositioning resulted in significant increases in contact pressures, patellar translation, tilt, and graft tightening or loosening. Low tension grafts (2 N) most closely restored the patellofemoral contact pressures, translation, and tilt. Graft fixation angles variably and inconsistently altered contact pressures, and patellar translation and tilt.
CONCLUSION
Data demonstrated that placement of the MPFLR femoral tunnel at the Schöttle point is critical to success. Femoral tunnel diameter should be ≥2 mm greater than graft diameter to limit graft advancement and overtensioning. Graft fixation, regardless of graft choice or fixation angle, is optimally performed under minimal tension with patellar fixation at the medial and superomedial patella. However, lower fixation angles may reduce graft strain, and higher fixation angles may exacerbate anisometry and length changes if femoral tunnel placement is nonanatomic.
PubMed: 38855071
DOI: 10.1177/23259671241241537 -
Aesthetic Surgery Journal. Open Forum 2024Both biologic and synthetic mesh have been found to reduce the risk of capsular contracture, yet there is limited data assessing the use of these scaffold materials in...
BACKGROUND
Both biologic and synthetic mesh have been found to reduce the risk of capsular contracture, yet there is limited data assessing the use of these scaffold materials in revision breast reconstruction.
OBJECTIVES
This investigation sought to assess the ability of either biologic or synthetic mesh to prevent capsular contracture in the revision breast reconstruction population.
METHODS
A retrospective chart review was conducted of implant-based revision reconstructions performed by the senior author between 2008 and 2023. Patient demographics and outcomes were assessed, including the incidence of Baker Grade III or IV capsular contractures. Results were compared between biologic and synthetic mesh groups using univariate and multivariate analysis.
RESULTS
Ninety-five breasts underwent revision reconstruction with 90 (94.7%) for correction of malposition, 4 (4.2%) for size change, and 1 (1.1%) for revision after additional oncologic breast surgery. Of these breasts, 26 (27.4%) used biologic mesh and 69 (72.6%) used synthetic mesh. Capsular contracture occurred in 1 (3.8%) biologic mesh breast and 4 (5.8%) synthetic mesh breasts. There was no significant difference in the incidence of capsular contracture between the 2 groups ( = 1.000). None of the recorded demographics were risk factors for capsular contracture, including the use of biologic or synthetic mesh ( = .801).
CONCLUSIONS
Both biologic and synthetic mesh are successful at preventing capsular contracture in patients undergoing implant-based revision reconstruction. This adds to the growing evidence that both scaffold materials can be used in complex revision breast reconstruction to aid in preventing capsular contracture.
PubMed: 38854738
DOI: 10.1093/asjof/ojae035 -
BMC Musculoskeletal Disorders Jun 2024Work-related musculoskeletal disorders have a greater negative impact on nurses' well-being, both physically and emotionally. Because of this issue, nurses take...
INTRODUCTION
Work-related musculoskeletal disorders have a greater negative impact on nurses' well-being, both physically and emotionally. Because of this issue, nurses take excessive leave, are absent from work, quit their profession, and have a lower quality of life. This leads to an increase in human and economic losses to health care institutions. However, there is a paucity of information about work-related musculoskeletal disorders among nurses in the study area.
OBJECTIVE
This study aimed to assess the magnitude of work-related musculoskeletal disorders and its factors associated among nurses in Hospitals of West Shoa Zone, Central Ethiopia, 2021.
MATERIALS AND METHODS
A cross-sectional facility-based study was conducted with 406 systematically selected nurses from March 2021 to June 2021. A simple random sampling was used to select study subjects. Data were gathered through face-to-face interviews. The data has been cleaned and checked, entered Epi Data 3.1, and exported into Statistical Package for Social Sciences software version 25 for further analysis. Bivariable and multiple logistic regressions were used to determine the factors associated with outcome variable. The level of statistical significance was reported to be less than 0.05.
RESULTS
The prevalence of work-related musculoskeletal disorders was 73.8% and the highest report 247 (62.2%) was seen in the lower back which was followed by the neck 182 (45.8%) and elbow 126 (31.7%), while the lowest affected body part was ankle 46(11.6%). Working in the medical ward (COR = 5.91, 95%CI: 2.53-13.79), surgical ward (COR = 9.63, 95%CI: 3.64-15.51), and operation room theater (COR = 6.02, 95%CI: 2.37-15.27) had higher risk to work-related musculoskeletal discomfort as compared to those who were worked in outpatient department. Nurses those experienced bending or twisting back as a problem during work 2.33 times more likely to have higher risk WMSDs as compared to those who didn't perceive it with (COR 2.33, 95% CI: 1.47-3.71).
CONCLUSION
In this study, the prevalence of work-related musculoskeletal disorders among nurses was high. Working in room/ward, working in malposition, have no on job training to prevent work-related musculoskeletal disorders and bending or twisting back during work were identified as associated factors. Since work-related musculoskeletal disorders are preventable, educating the staff about the use of proper body mechanics and modifying the work environment is essential.
Topics: Humans; Ethiopia; Cross-Sectional Studies; Occupational Diseases; Adult; Musculoskeletal Diseases; Female; Male; Prevalence; Nursing Staff, Hospital; Risk Factors; Middle Aged; Young Adult; Nurses
PubMed: 38849729
DOI: 10.1186/s12891-024-07479-x -
Contraception Jun 2024This study aimed to compare removal timing, techniques, and success of malpositioned intrauterine device (IUDs) to nonmalpositioned IUDs.
OBJECTIVE
This study aimed to compare removal timing, techniques, and success of malpositioned intrauterine device (IUDs) to nonmalpositioned IUDs.
STUDY DESIGN
We performed a retrospective cohort study of IUD users with ultrasound performed between July 2014 and July 2017 within one medical system. We used Fisher exact and Wilcoxon rank-sum tests to compare clinical characteristics and IUD removal details between patients with malpositioned and nonmalpositioned IUDs.
RESULTS
Of 1759 ultrasounds reporting the presence of an IUD, 436 described IUD malposition. Of these, 150 described the IUD as embedded and 16 as partially perforated. IUDs were more likely to be removed and removed sooner for patients with malpositioned compared with nonmalpositioned IUDs (281/436 vs 545/1323, p < 0.001 and median 17 days vs 236 days from the index ultrasound, p < 0.001). Most IUDs, malpositioned and nonmalpositioned, were removed on the first attempt (82%, 85%), by a generalist obstetrician and gynecologist (75%, 70%), using a ring forceps (73%, 65%). Most embedded and partially perforated IUDs were removed (68%, 69%), using a ring forceps (59%, 67%), on the first attempt (84%, 91%).
CONCLUSIONS
Malpositioned IUDs were more likely to be removed and removed sooner than nonmalpositioned IUDs. Most IUDs, even IUDs labeled as partially perforated or embedded, were removed by a generalist obstetrician and gynecologist, using ring forceps, on first attempt.
IMPLICATIONS
Ultrasound findings of IUD malposition are not associated with difficult IUD removal.
PubMed: 38848813
DOI: 10.1016/j.contraception.2024.110504 -
Medicine Jun 2024Central venous catheter (CVC) placement is a challenging procedure with known iatrogenic risks. However, there are no residency program requirements to demonstrate...
Central venous catheter (CVC) placement is a challenging procedure with known iatrogenic risks. However, there are no residency program requirements to demonstrate baseline CVC procedural competency. Competency-based procedural education has been shown to decrease CVC-associated morbidity, but there has been limited literature about institution-wide efforts to ensure initial trainee competency for CVC placement. This study describes the implementation of a competency-based CVC curriculum for first-year interns across an institution before supervised clinical care. An institution-wide, simulation-based mastery training curriculum was designed to assess initial competency in CVC placement in first-year residents during 2021 and 2022. A checklist was internally developed with a multidisciplinary team. Using the Mastery-Angoff technique, minimum passing standards were derived to define competency levels considered appropriate for intern participation in supervised clinical care. Interns were trained through the competency-based program with faculty assessing intern performance using the CVC checklist to verify procedural competency. Over 2 academic cycles, 229 interns from 20 specialties/subspecialties participated. Overall, 83% of interns met performance standards on their first posttest attempt, 14% on the second attempt, and 3% on the third attempt. Interns from both cycles demonstrated significant improvement from baseline to posttest scores (P < .001). Overall, 10.5% of interns performed dangerous actions during assessment (malpositioning, retained guidewire, or carotid dilation). All interns ultimately achieved the passing standard to demonstrate initial competency in the simulation assessment. All participating interns demonstrated simulation-based competency allowing them to place CVCs under supervised clinical care. Dangerous actions, however, were not uncommon. Simulation-based teaching and learning frameworks were a feasible method to promote patient safety through an institutional-wide verification of preliminary procedural competency.
Topics: Humans; Internship and Residency; Clinical Competence; Catheterization, Central Venous; Simulation Training; Curriculum; Checklist; Competency-Based Education; Central Venous Catheters; Education, Medical, Graduate
PubMed: 38847719
DOI: 10.1097/MD.0000000000038346 -
Medicine Jun 2024To explore the clinical application value of intracavitary electrocardiogram (ECG) localization combined with ultrasound in central venous catheterization in critically... (Observational Study)
Observational Study
Clinical application of intracavitary electrocardiogram localization combined with ultrasound in central venous catheterization in critically ill patients: An observational study.
To explore the clinical application value of intracavitary electrocardiogram (ECG) localization combined with ultrasound in central venous catheterization in critically ill patients. A total of 103 patients who were treated in the intensive care unit of our hospital from October 2020 to June 2023 were selected as the study subjects, and according to the differences in their central venous catheter placement methods, they were divided into study group (n = 52, receiving ultrasound combined with intracavitary ECG localization for catheterization) and control group (n = 51, receiving routine catheterization). The differences in the catheter placement accuracy, catheter depth, catheter placement duration, incidence of catheter-related complications, length of stay, and hospitalization expenses between the 2 groups were compared. The analysis utilizing X-ray for catheter tip positioning indicated that the catheter tip placement rate was higher in the study group than in the control group, and the catheter tip malposition rate was lower than in the control group (P < .05). There was no statistical significance in the catheter depth between study group and control group (P > .05), and the catheter placement duration of study group was significantly lower than that of control group, with statistical significance (P < .05). One case of partial catheter blockage, one case of catheter-related bloodstream infection, and one case of phlebitis were observed in study group, with an overall incidence of complications of 5.77% (3/52), which was significantly lower than 21.57% (11/51) of control group (P < .05). The length of stay and hospitalization expenses in study group were significantly lower than those in control group, with statistical significance (P < .05). The combined use of ultrasound and intracavitary ECG localization in critically ill patients undergoing central venous catheterization can help increase the success rate of catheter placement, shorten the catheter placement duration, reduce the incidence of various catheter-related complications, and also reduce the length of stay and hospitalization expenses.
Topics: Humans; Male; Female; Electrocardiography; Critical Illness; Middle Aged; Catheterization, Central Venous; Intensive Care Units; Length of Stay; Aged; Ultrasonography, Interventional; Adult; Ultrasonography
PubMed: 38847702
DOI: 10.1097/MD.0000000000038372 -
Eplasty 2024The transconjunctival approach paired with lateral canthotomy is a commonly used technique for widened exposure of the orbital floor and infraorbital rim. A major...
BACKGROUND
The transconjunctival approach paired with lateral canthotomy is a commonly used technique for widened exposure of the orbital floor and infraorbital rim. A major drawback of this approach is the severance of lateral canthal ligament fibers, which predisposes to potential postoperative eyelid malpositioning. To avoid these suboptimal aesthetic outcomes, a modification of this approach has been proposed in which the lower eyelid is mobilized with a paracanthal, trans-tarsal stair-step incision. In this pilot study, we describe our experience with the trans-tarsal stairstep incision for lateral extension of the transconjunctival incision and report its outcomes in a Western population.
METHODS
All patients who underwent facial fracture operative fixation at a single institution by a single senior surgeon were included. Clinical variables were extracted. Patients were stratified by incision type.
RESULTS
Compared with patients who underwent subtarsal incision (n = 20) and transconjunctival incision with lateral canthotomy (n = 4), patients who received the trans-tarsal stair-step incision (n = 10) had no incision-related complications or requirements for revision. The most common complications found in the comparison groups were ectropion and hypertrophic or irregular scarring, and 4 patients required revision.
CONCLUSIONS
Our initial experience with the transconjunctival approach with the trans-tarsal stair-step incision shows promising outcomes. Further study may promote greater utilization of this technique in Western countries.
PubMed: 38846500
DOI: No ID Found -
Cureus May 2024Percutaneous central venous catheterization, despite ultrasound guidance, is known to carry significant risks. While central venous catheters are widely used in clinical...
Percutaneous central venous catheterization, despite ultrasound guidance, is known to carry significant risks. While central venous catheters are widely used in clinical practice, they are also associated with various complications, including incorrect positioning during insertion. Arterial puncture is a well-recognized complication, and although unintended subclavian or carotid artery cannulation is rare, it can lead to serious consequences. We present two cases, in which a dual-lumen, non-tunneled temporary hemodialysis catheter was inadvertently inserted into the left common carotid artery and in the left innominate vein.
PubMed: 38846204
DOI: 10.7759/cureus.59814