Breast Cancer Research : BCR Jul 2024The effect of gender-affirming testosterone therapy (TT) on breast cancer risk is unclear. This study investigated the association between TT and breast tissue...
BACKGROUND
The effect of gender-affirming testosterone therapy (TT) on breast cancer risk is unclear. This study investigated the association between TT and breast tissue composition and breast tissue density in trans masculine individuals (TMIs).
METHODS
Of the 444 TMIs who underwent chest-contouring surgeries between 2013 and 2019, breast tissue composition was assessed in 425 TMIs by the pathologists (categories of lobular atrophy and stromal composition) and using our automated deep-learning algorithm (% epithelium, % fibrous stroma, and % fat). Forty-two out of 444 TMIs had mammography prior to surgery and their breast tissue density was read by a radiologist. Mammography digital files, available for 25/42 TMIs, were analyzed using the LIBRA software to obtain percent density, absolute dense area, and absolute non-dense area. Linear regression was used to describe the associations between duration of TT use and breast tissue composition or breast tissue density measures, while adjusting for potential confounders. Analyses stratified by body mass index were also conducted.
RESULTS
Longer duration of TT use was associated with increasing degrees of lobular atrophy (p < 0.001) but not fibrous content (p = 0.82). Every 6 months of TT was associated with decreasing amounts of epithelium (exp(β) = 0.97, 95% CI 0.95,0.98, adj p = 0.005) and fibrous stroma (exp(β) = 0.99, 95% CI 0.98,1.00, adj p = 0.05), but not fat (exp(β) = 1.01, 95%CI 0.98,1.05, adj p = 0.39). The effect of TT on breast epithelium was attenuated in overweight/obese TMIs (exp(β) = 0.98, 95% CI 0.95,1.01, adj p = 0.14). When comparing TT users versus non-users, TT users had 28% less epithelium (exp(β) = 0.72, 95% CI 0.58,0.90, adj p = 0.003). There was no association between TT and radiologist's breast density assessment (p = 0.58) or LIBRA measurements (p > 0.05).
CONCLUSIONS
TT decreases breast epithelium, but this effect is attenuated in overweight/obese TMIs. TT has the potential to affect the breast cancer risk of TMIs. Further studies are warranted to elucidate the effect of TT on breast density and breast cancer risk.
Topics: Humans; Breast Density; Female; Adult; Testosterone; Transgender Persons; Mammography; Breast; Male; Middle Aged; Breast Neoplasms; Body Mass Index; Sex Reassignment Procedures
PubMed: 38956693
DOI: 10.1186/s13058-024-01867-w -
Physical and Engineering Sciences in... Jul 2024Contrast-enhanced mammography is being increasingly implemented clinically, providing much improved contrast between tumour and background structures, particularly in...
Contrast-enhanced mammography is being increasingly implemented clinically, providing much improved contrast between tumour and background structures, particularly in dense breasts. Although CEM is similar to conventional mammography it differs via an additional exposure with high energy X-rays (≥ 40 kVp) and subsequent image subtraction. Because of its special operational aspects, the CEM aspect of a CEM unit needs to be uniquely characterised and evaluated. This study aims to verify the utility of a commercially available phantom set (BR3D model 020 and CESM model 022 phantoms (CIRS, Norfolk, Virginia, USA)) in performing key CEM performance tests (linearity of system response with iodine concentration and background subtraction) on two models of CEM units in a clinical setting. The tests were successfully performed, yielding results similar to previously published studies. Further, similarities and differences in the two systems from different vendors were highlighted, knowledge of which may potentially facilitate optimisation of the systems.
PubMed: 38954379
DOI: 10.1007/s13246-024-01461-6 -
Annals of Surgical Oncology Jul 2024Invasive lobular carcinoma (ILC) is the second most common subtype of breast cancer. Although mammography is known to have low sensitivity for ILC, there are no data to...
Surveillance Strategies After Primary Treatment for Patients with Invasive Lobular Carcinoma of the Breast: Method of Local Recurrence Detection After Breast-Conserving Surgery.
BACKGROUND
Invasive lobular carcinoma (ILC) is the second most common subtype of breast cancer. Although mammography is known to have low sensitivity for ILC, there are no data to guide the optimal surveillance after treatment. We explored surveillance strategies after breast-conserving surgery (BCS) for ILC and determined the proportion of imaging-detected recurrences versus interval cancers.
METHODS
From an institutional database of 813 women, we retrospectively identified patients who underwent BCS for stage I-III ILC and subsequently had a recurrence. We categorized patients by surveillance strategy and determined the modality of recurrence detection. Interval cancer rates for local recurrences were compared across surveillance strategies using the Chi-square test. We evaluated overall survival with the log-rank test and a Cox proportional hazards model.
RESULTS
We included 58 patients with ILC who had a recurrence after BCS. Of these, 22 (37.9%) had local recurrence, 27 (46.6%) had distant recurrence, and 9 (15.5%) had both local and distant recurrence. Most patients underwent routine mammographic surveillance (65.2%), with 19.6% having supplemental breast magnetic resonance imaging (MRI) and 15.2% having no surveillance. The interval cancer rate was significantly higher in the mammographic surveillance group compared with the MRI surveillance group (61.9% vs. 16.7%; p < 0.001).
CONCLUSION
In this study of patients with recurrence after BCS for primary treatment of stage I-III ILC, we found that most local recurrences were not detected by surveillance mammography. These data support further investigation of supplemental imaging beyond mammography specifically for patients with ILC who undergo BCS.
PubMed: 38954091
DOI: 10.1245/s10434-024-15710-1 -
Cureus Jun 2024Introduction Disparities in access to breast cancer screening led to the creation of the Linda Fenner 3D Mobile Mammography Center (LFMMC), successfully increasing...
Introduction Disparities in access to breast cancer screening led to the creation of the Linda Fenner 3D Mobile Mammography Center (LFMMC), successfully increasing screening for uninsured women in Miami-Dade. However, a higher-than-expected rate of inconclusive mammograms (Breast Imaging-Reporting and Data System (BI-RADS) 0) was found, which could lead to unnecessary procedures, stress, costs, and radiation. Methods In this retrospective cross-sectional study, we analyzed data from 3,044 uninsured women aged over 40 (younger if positive family history of breast cancer) from Miami-Dade without breast symptoms or breast cancer history. Women's demographic characteristics, primary language spoken, body mass index (BMI), use of hormone replacement therapy and birth control, history of benign biopsy, breast surgery, family breast cancer, and menopausal status were assessed as potential risk factors for an inconclusive (BI-RADS 0) screening mammogram result. Multivariable logistic regression analyses were used to evaluate associations. Results The average age of women was 51 years (SD = 9); 59% were White, and 30% were African American. The overall frequency of BI-RADS 0 was 35%. Higher odds of BI-RADS 0 were found for women who were younger, single, premenopausal, and with benign biopsy history. Conversely, obesity and breast implant history decreased the odds of BI-RADS 0. Conclusion We found a high frequency of BI-RADS 0 in the LFMMC sample. Potential reasons include a higher risk for breast cancer or a younger sample of women screened. Future research should explore radiologists' reasoning for assigning BI-RADS 0 results and testing alternative screening strategies for younger women.
PubMed: 38952599
DOI: 10.7759/cureus.61495 -
Journal of the American College of... Jun 2024To share the experience and results of the first cohort of the ACR Mammography Positioning Improvement Collaborative, in which participating sites aimed to increase the...
PURPOSE/OBJECTIVE
To share the experience and results of the first cohort of the ACR Mammography Positioning Improvement Collaborative, in which participating sites aimed to increase the mean percentage of screening mammograms meeting the established positioning criteria to 85% or greater and show at least modest evidence of improvement at each site by the end of the improvement program.
METHODS
The sites comprising the first cohort of the Collaborative were selected on the basis of strength of local leadership support, intra-organizational relationships, access to data and analytic support, and experience with quality improvement (QI) initiatives. During the improvement program, participating sites organized their teams, developed goals, gathered data, evaluated their current state, identified key drivers and root causes of their problems, and developed and tested interventions. A standardized image quality scoring system was also established. The impact of the interventions implemented at each site was assessed by tracking the percentage of screening mammograms meeting overall passing criteria over time.
RESULTS
Six organizations were selected to participate as the first cohort, beginning with participation in the improvement program. Interventions developed and implemented at each site during the program resulted in improvement in the average percentage of screening mammograms meeting overall passing criteria per week from a collaborative mean of 51% to 86%, with four of six sites meeting or exceeding the target mean performance of 85% by the end of the improvement program. Afterwards, all respondents to the post-program survey indicated that the program was a positive experience.
CONCLUSION
Using a structured improvement program within a learning network framework, the first cohort of the Collaborative demonstrated that improvement in mammography positioning performance can be achieved at multiple sites simultaneously, and validated the hypothesis that local sites' shared experiences, insights, and learnings would not only improve performance but would also build a community of improvers collaborating to create the best experience for technologists, staff, and patients.
PubMed: 38950833
DOI: 10.1016/j.jacr.2024.06.013 -
Annals of Surgical Oncology Jun 2024High-risk programs provide recommendations for surveillance/risk reduction for women at elevated risk for breast cancer development. This study evaluated the impact of...
BACKGROUND
High-risk programs provide recommendations for surveillance/risk reduction for women at elevated risk for breast cancer development. This study evaluated the impact of high-risk surveillance program participation on clinicopathologic breast cancer features at the time of diagnosis.
METHODS
Women followed in the authors' high-risk program (high-risk cohort [HRC]) with a diagnosis of breast cancer from January 2015 to June 2021 were identified and compared with the general population of women undergoing breast cancer surgery at Memorial Sloan Kettering Cancer Center (MSK; general cohort [GC]) during the same period. Patient and tumor factors were collected. Clinicopathologic features were compared between the two cohorts and in a subset of women with a family history of known BRCA mutation.
RESULTS
The study compared 255 women in the HRC with 9342 women in the GC. The HRC patients were slightly older and more likely to be white and have family history than the GC patients. The HRC patients also were more likely to present with DCIS (41 % vs 23 %; p < 0.001), to have smaller invasive tumors (pT1: 100 % vs 77 %; p < 0.001), and to be pN0 (95 % vs 81 %; p < 0.001). The HRC patients had more invasive triple-negative tumors (p = 0.01) and underwent less axillary surgery (p < 0.001), systemic therapy (p < 0.001), and radiotherapy (p = 0.002). Among those with a known BRCA mutation, significantly more women in the HRC underwent screening mammography (75 % vs 40 %; p < 0.001) or magnetic resonance imaging (MRI: 82 % vs 9.9 %; p < 0.001) in the 12 months before diagnosis.
CONCLUSIONS
Women followed in a high-risk screening program have disease diagnosed at an earlier stage and therefore require less-intensive breast cancer treatment than women presenting to a cancer center at the time of diagnosis. Identification of high-risk women and implementation of increased surveillance protocols are vital to improving outcomes.
PubMed: 38949720
DOI: 10.1245/s10434-024-15633-x -
ANZ Journal of Surgery Jul 2024Invasive lobular carcinoma (ILC) is challenging to stage accurately using mammography (MG) and ultrasound (US) with undiagnosed ipsilateral and contralateral cancer...
BACKGROUND
Invasive lobular carcinoma (ILC) is challenging to stage accurately using mammography (MG) and ultrasound (US) with undiagnosed ipsilateral and contralateral cancer resulting in poor patient outcomes including return to surgery. Our institution employs routine staging breast MRI in ILC for this reason. However, increased time for further imaging/biopsies contributes to patient anxiety and potentially delays definite management. We aimed to quantify the frequency of staging MRI-detected additional lesions requiring biopsy or follow-up, the added cancer detection rate and MRI prompted change in surgical management.
METHODS
An observational study on staging breast MRI for newly diagnosed ILC at a tertiary Western Australian hospital from January 2019 to August 2022. Standardized 3T MRI protocol was performed, double read by unblinded fellowship-trained radiologists. Histopathology from biopsy, surgery, or first annual surveillance was the reference standard for additional MRI-detected lesions.
RESULTS
One hundred ten MRI studies demonstrated 49 (45%) patients had at least one additional clinically significant MRI-detected lesion. Thirty-one patients had an additional ipsilateral lesion detected, of which 18 (58%) proved malignant; 14 (45%) multifocal and 4 (13%) multicentric ILC. Additional work-up of MRI-detected lesions averaged a 9-day delay to definitive surgery compared to patients with a negative or definitively benign MRI. MRI changed surgical planning in 11 of 110 cases from breast conservation surgery (BCS) to mastectomy and there were two contralateral cancers diagnosed. BCS reoperation rate was 11%.
CONCLUSION
Staging MRI for ILC identifies clinically significant lesions in nearly half of patients, predominantly ipsilateral multifocal disease, without significant delay to definitive surgery.
PubMed: 38949091
DOI: 10.1111/ans.19140 -
Investigative Radiology Jul 2024To evaluate the detectability of non-contrast-enhanced and contrast-enhanced spiral breast computed tomography ([non]-CE-SBCT) compared with mammography. Secondary...
OBJECTIVES
To evaluate the detectability of non-contrast-enhanced and contrast-enhanced spiral breast computed tomography ([non]-CE-SBCT) compared with mammography. Secondary objectives are to determine detectability depending on breast density and to evaluate appearance of breast malignancies according to BI-RADS descriptors.
METHODS
This retrospective institutional review board-approved study included 90 women with 105 biopsy-proven malignant breast lesions. Breast density, BI-RADS descriptors, and detectability were evaluated by 2 independent readers. Diagnostic confidence was rated on a 4-point Likert scale.
RESULTS
For readers 1 and 2, detectability was 83.8% and 80.0% for mammography, 99.1% and 99.1% for CE-SBCT ( P < 0.05), and 66.7% and 61.9% for non-CE-SBCT ( P < 0.05). With both readers, detectability in CE-SBCT was high for density A/B/C/D (both 100%/100%/100%/87.5%). Detectability of readers declined with increasing density for mammography (density A = 100%, B = 89.1% and 95.1%, C = 73.1%, D = 50.0% and 71.4%; P < 0.05) and for non-CE-SBCT (density A = 87.5% and 90.7%, B = 65.5% and 69.1%, C = 54.8% and 60.0%, D = 37.5%; P < 0.05). Mass lesions were detected with CT as often as with mammography, whereas architectural distortions and microcalcifications were detected less often with SBCT. Diagnostic confidence was very high or high in 97.2% for CE-SBCT, in 74.1% for non-CE-SBCT, and in 81.4% for mammography.
CONCLUSIONS
Detectability and diagnostic confidence were very high in CE-SBCT, regardless of breast density. The detectability of non-CE-SBCT was lower than that of mammography and declined with increasing breast density.
PubMed: 38949016
DOI: 10.1097/RLI.0000000000001105 -
Journal of Plastic, Reconstructive &... Jun 2024Assessment of breast volume is essential in preoperative planning of immediate breast reconstruction (IBR) surgery to achieve satisfactory cosmetic outcome. This study...
BACKGROUND
Assessment of breast volume is essential in preoperative planning of immediate breast reconstruction (IBR) surgery to achieve satisfactory cosmetic outcome. This study introduced a breast volume measurement tool that can be used to perform automatic segmentation of magnetic resonance images (MRI) and calculation of breast volume. We compared the accuracy and reliability of this measurement method with four other conventional modalities.
METHODS
Patients who were scheduled to undergo mastectomy with IBR between 2016 and 2021 were enrolled in the study. Five different breast volume assessments, including automatic segmentation of MRI, manual segmentation of MRI, 3D surface imaging, mammography, and the BREAST-V formula, were used to evaluate different breast volumes. The results were validated using water displacement volumes of the mastectomy specimens.
RESULTS
In this pilot study, a total of 50 female patients met the inclusion criteria and contributed 54 breast specimens to the volumetric analysis. There was a strong linear association between the MRI and water displacement methods (automatic segmentation: r = 0.911, p < 0.001; manual segmentation: r = 0.924, p < 0.001), followed by 3D surface imaging (r = 0.858, p < 0.001), mammography (r = 0.841, p < 0.001), and Breast-V formula (r = 0.838, p < 0.001). Breast volumes measured using automatic and manual segmentation of MRI had lower mean relative errors (30.3% ± 22.0% and 28.9% ± 19.8, respectively) than 3D surface imaging (38.9% ± 31.2), Breast-V formula (44.8% ± 25.8), and mammography (60.3% ± 37.6).
CONCLUSION
Breast volume assessment using the MRI methods had better accuracy and reliability than the other methods used in our study. Breast volume measurement using automatic segmentation of MRI could be more efficient compared to the conventional methods.
PubMed: 38943699
DOI: 10.1016/j.bjps.2024.05.029 -
Journal of Breast Imaging Jun 2024To evaluate the effects of the Enhancing Quality Using the Inspection Program (EQUIP) on quality control (QC) and quality assurance (QA) at an academic medical center.
OBJECTIVES
To evaluate the effects of the Enhancing Quality Using the Inspection Program (EQUIP) on quality control (QC) and quality assurance (QA) at an academic medical center.
METHODS
EQUIP audit logs for technologist image quality review as well as mammography unit QA and QC formed the basis for study data. One randomly selected screening mammogram was evaluated by the lead interpreting physician (LIP) using EQUIP criteria for each technologist for each imaging site worked, initially semiannually and then monthly. One randomly selected screening mammogram interpreted by each interpreting physician (IP) for each imaging site was evaluated on a semiannual basis. Quarterly, the LIP reviewed QA and QC logs for each mammography unit with deficiencies further investigated.
RESULTS
Of 214 965 eligible screening mammograms performed, 5955 (2.8%) underwent EQUIP image quality review. Five were found to be technically inadequate (0.08%, 5955/214 965). The LIP identified 20 significant interpretive differences compared with the clinical interpretation resulting in 10 biopsies and 7 previously undetected malignancies, with supplemental cancer detection rate of 1.2/1000 cases reviewed. Two hundred ninety mammography unit QA/QC reviews identified 31 potential deficiencies, 29 of which were due to human documentation error (93.4%).
CONCLUSION
EQUIP review of both IP and technologists' quality and mammography unit QA/QC logs as performed identified few deficiencies. EQUIP policies should be evaluated at each institution and modified to best utilize resources and provide opportunities for meaningful quality improvement. Although not an EQUIP focus, supplemental cancer detection was observed as might be expected with double reading.
PubMed: 38943287
DOI: 10.1093/jbi/wbae034