The Bone & Joint Journal Jul 2024Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but... (Comparative Study)
Comparative Study
AIMS
Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up.
METHODS
This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).
RESULTS
There were no differences between the two treatment groups with regard to mean change in haemoglobin concentration (p = 0.477), length of stay (LOS, p = 0.172), mean polyethylene thickness (p = 0.065), or postoperative complication rates (p = 0.295). At the most recent follow-up, the primary robotic arm-assisted TKA group had a statistically significantly improved OKS compared with the revision UKA to TKA group (44.6 (SD 2.7) vs 42.3 (SD 2.5); p = 0.004) but there was no difference in the overall ROM (p = 0.056) or FJS between the two treatment groups (86.1 (SD 9.6) vs 84.1 (4.9); p = 0.439).
CONCLUSION
Robotic arm-assisted revision of UKA to TKA was associated with comparable intraoperative blood loss, early postoperative rehabilitation, functional outcomes, and complications to primary robotic TKA at short-term follow-up. Robotic arm-assisted surgery offers a safe and reproducible technique for revising failed UKA to TKA.
Topics: Humans; Arthroplasty, Replacement, Knee; Male; Female; Prospective Studies; Robotic Surgical Procedures; Aged; Middle Aged; Reoperation; Treatment Outcome; Range of Motion, Articular; Follow-Up Studies; Length of Stay; Postoperative Complications; Knee Prosthesis; Aged, 80 and over; Osteoarthritis, Knee
PubMed: 38945538
DOI: 10.1302/0301-620X.106B7.BJJ-2023-0943.R2 -
The Bone & Joint Journal Jul 2024Paediatric fractures are highly prevalent and are most often treated with plaster. The application and removal of plaster is often an anxiety-inducing experience for... (Randomized Controlled Trial)
Randomized Controlled Trial
AIMS
Paediatric fractures are highly prevalent and are most often treated with plaster. The application and removal of plaster is often an anxiety-inducing experience for children. Decreasing the anxiety level may improve the patients' satisfaction and the quality of healthcare. Virtual reality (VR) has proven to effectively distract children and reduce their anxiety in other clinical settings, and it seems to have a similar effect during plaster treatment. This study aims to further investigate the effect of VR on the anxiety level of children with fractures who undergo plaster removal or replacement in the plaster room.
METHODS
A randomized controlled trial was conducted. A total of 255 patients were included, aged five to 17 years, who needed plaster treatment for a fracture of the upper or lower limb. Randomization was stratified for age (five to 11 and 12 to 17 years). The intervention group was distracted with VR goggles and headphones during the plaster treatment, whereas the control group received standard care. As the primary outcome, the post-procedural level of anxiety was measured with the Child Fear Scale (CFS). Secondary outcomes included the children's anxiety reduction (difference between CFS after and CFS before plaster procedure), numerical rating scale (NRS) pain, NRS satisfaction of the children and accompanying parents/guardians, and the children's heart rates during the procedure. An independent-samples -test and Mann-Whitney U test (depending on the data distribution) were used to analyze the data.
RESULTS
The post-procedural CFS was significantly lower (p < 0.001) in the intervention group (proportion of children with no anxiety = 78.6%) than in the control group (56.8%). The anxiety reduction, NRS pain and satisfaction scores, and heart rates showed no significant differences between the control group and the intervention group. Subanalyses showed an increased effect of VR on anxiety levels in young patients, females, upper limb fractures, and those who had had previous plaster treatment.
CONCLUSION
VR effectively reduces the anxiety levels of children in the plaster room, especially in young girls. No statistically significant effects were seen regarding pain, heart rate, or satisfaction scores.
Topics: Humans; Child; Casts, Surgical; Female; Adolescent; Male; Child, Preschool; Anxiety; Virtual Reality; Fractures, Bone; Patient Satisfaction; Pain Measurement
PubMed: 38945536
DOI: 10.1302/0301-620X.106B7.BJJ-2023-0756.R2 -
The Bone & Joint Journal Jul 2024Radiological residual acetabular dysplasia (RAD) has been reported in up to 30% of children who had successful brace treatment of infant developmental dysplasia of the...
AIMS
Radiological residual acetabular dysplasia (RAD) has been reported in up to 30% of children who had successful brace treatment of infant developmental dysplasia of the hip (DDH). Predicting those who will resolve and those who may need corrective surgery is important to optimize follow-up protocols. In this study we have aimed to identify the prevalence and predictors of RAD at two years and five years post-bracing.
METHODS
This was a single-centre, prospective longitudinal cohort study of infants with DDH managed using a published, standardized Pavlik harness protocol between January 2012 and December 2016. RAD was measured at two years' mean follow-up using acetabular index-lateral edge (AI-L) and acetabular index-sourcil (AI-S), and at five years using AI-L, AI-S, centre-edge angle (CEA), and acetabular depth ratio (ADR). Each hip was classified based on published normative values for normal, borderline (1 to 2 standard deviations (SDs)), or dysplastic (> 2 SDs) based on sex, age, and laterality.
RESULTS
Of 202 infants who completed the protocol, 181 (90%) had two and five years' follow-up radiographs. At two years, in 304 initially pathological hips, the prevalence of RAD (dysplastic) was 10% and RAD (borderline) was 30%. At five years, RAD (dysplastic) decreased to 1% to 3% and RAD (borderline) decreased to < 1% to 2%. On logistic regression, no variables were predictive of RAD at two years. Only AI-L at two years was predictive of RAD at five years (p < 0.001). If both hips were normal at two years' follow-up (n = 96), all remained normal at five years. In those with bilateral borderline hips at two years (n = 21), only two were borderline at five years, none were dysplastic. In those with either borderline-dysplastic or bilateral dysplasia at two years (n = 26), three (12%) were dysplastic at five years.
CONCLUSION
The majority of patients with RAD at two years post-brace treatment, spontaneously resolved by five years. Therefore, children with normal radiographs at two years post-brace treatment can be discharged. Targeted follow-up for those with abnormal AI-L at two years will identify the few who may benefit from surgical correction at five years' follow-up.
Topics: Humans; Female; Male; Infant; Developmental Dysplasia of the Hip; Prospective Studies; Acetabulum; Braces; Longitudinal Studies; Child, Preschool; Treatment Outcome; Follow-Up Studies; Radiography; Hip Dislocation, Congenital
PubMed: 38945534
DOI: 10.1302/0301-620X.106B7.BJJ-2023-1169.R1 -
International Journal of Cardiology Jun 2024Anatomic variations of the patent foramen ovale (PFO) are commonly observed, yet limited research has investigated their impact on clinical outcomes following...
BACKGROUND
Anatomic variations of the patent foramen ovale (PFO) are commonly observed, yet limited research has investigated their impact on clinical outcomes following transcatheter closure. We aimed to explore the association between PFO morphology and clinical outcomes.
METHODS
Consecutive patients with cryptogenic stroke who underwent PFO closure were prospectively enrolled at a single center from September 2019 to April 2023. Patients were categorized into simple and complex groups based on PFO morphology. Composite events were compared between the two groups during a median follow-up of 24 months, including all-cause mortality, recurrent stroke, residual moderate or severe shunt, and symptomatic atrial fibrillation.
RESULTS
A total of 247 patients were enrolled, with a mean age of 41.9 ± 13.0 years and 45.3% males. Ninety-one (36.8%) patients had complex PFO. These individuals were older (45.4 ± 12.5 years vs. 39.9 ± 12.9 years; P = 0.001), more males (56.0% vs. 39.1%; P = 0.010), had longer procedure times (54 ± 32 min vs 46 ± 29 min; P = 0.044), and had a higher rate of using delivery sheath-assisted crossing of the PFO (22.0% vs 12.8%; P = 0.040) than those with simple PFO. The estimated event rates were 27.9% and 11.3% (P = 0.006) in the complex and simple PFO groups, respectively (12.9 events and 5.2 events per 100 person-years; P = 0.001). After adjusting for age, sex, hypertension, diabetes, smoking, device type, and left atrial diameters, complex PFO remained independently associated with composite events (HR 2.10, 95%CI 1.06-4.17, P = 0.034).
CONCLUSIONS
Patients with complex PFO may suffer from a higher risk of adverse events following transcatheter PFO closure.
PubMed: 38945369
DOI: 10.1016/j.ijcard.2024.132307 -
Journal of Vascular Surgery. Venous and... Jun 2024
Review
PubMed: 38945362
DOI: 10.1016/j.jvsv.2024.101940 -
Contraception Jun 2024To evaluate the method of immediate postpartum IUD (ppIUD) insertion (manual versus ring forceps) and expulsion rate within 6-weeks postpartum.
OBJECTIVE
To evaluate the method of immediate postpartum IUD (ppIUD) insertion (manual versus ring forceps) and expulsion rate within 6-weeks postpartum.
STUDY DESIGN
We performed a retrospective cohort study of patients who had a singleton vaginal delivery and an immediate ppIUD inserted at Rush University from January 2014 to September 2023. The primary outcome was rate of expulsion within 6-weeks postpartum. We compared the rate of expulsion by method of insertion, either using a manual technique versus using ring forceps. We performed univariable analysis for the association between baseline maternal characteristics and the primary outcome and we performed multivariable logistic regression to determine the independent association of the method of insertion and the primary outcome.
RESULTS
Two hundred nineteen patients met eligibility with 117 immediate ppIUDs inserted manually and 102 inserted with ring forceps. Baseline maternal demographics were similar across study groups. After adjusting for factors selected a priori (estimated blood loss, body mass index, gestational age at delivery, nulliparity, type of IUD), use of ring forceps was more likely to result in expulsion compared to manual insertion (30.4% vs 16.2% respectively; adjusted OR 2.49, 95% confidence interval 1.28-4.90).
CONCLUSION
In this retrospective analysis, insertion of immediate ppIUD with ring forceps was independently associated with an increased rate of expulsion within 6 weeks postpartum when compared to manual insertion.
IMPLICATIONS
In this setting, ring forceps was associated with high rates of immediate postpartum IUD expulsion compared to manual technique. Studies disagree, suggesting need for additional work.
PubMed: 38945350
DOI: 10.1016/j.contraception.2024.110532 -
International Journal of Biological... Jun 2024Hyaluronic acid (HA) serves as a vitreous substitute owing to its ability to mimic the physical functions of native vitreous humor. However, pure HA hydrogels alone do...
Hyaluronic acid (HA) serves as a vitreous substitute owing to its ability to mimic the physical functions of native vitreous humor. However, pure HA hydrogels alone do not provide sufficient protection against potential inflammatory risks following vitrectomy. In this study, HA was crosslinked with 1,4-butanediol diglycidyl ether (BDDE) to form HA hydrogels (HB). Subsequently, the anti-inflammatory agent epigallocatechin gallate (EGCG) was added to the hydrogel (HBE) for ophthalmic applications as a vitreous substitute. The characterization results indicated the successful preparation of HB with transparency, refractive index, and osmolality similar to those of native vitreous humor, and with good injectability. The anti-inflammatory ability of HBE was also confirmed by the reduced expression of inflammatory genes in retinal pigment epithelial cells treated with HBE compared with those treated with HB. In a New Zealand white rabbit model undergoing vitreous substitution treatment, HBE 50 (EGCG 50 mM addition) exhibited positive results at 28 days post-surgery. These outcomes included restored intraocular pressure, improved electroretinogram responses, minimal increase in corneal thickness, and no inflammation during histological examination. This study demonstrated the potential of an injectable HA-BDDE cross-linked hydrogel containing EGCG as a vitreous substitute for vitrectomy applications, offering prolonged degradation time and anti-inflammatory effects postoperatively.
PubMed: 38945319
DOI: 10.1016/j.ijbiomac.2024.133467 -
Journal of Environmental Radioactivity Jun 2024Pu (T = 81 My) is the longest-lived, most minor, and the most understudied Pu isotope. The anthropogenic production of Pu is linked to nuclear detonations. Reported...
Pu (T = 81 My) is the longest-lived, most minor, and the most understudied Pu isotope. The anthropogenic production of Pu is linked to nuclear detonations. Reported Pu/Pu atom ratios in environmental samples range from below 10 to above 10. This work discusses the performance of the 1 MV Accelerator Mass Spectrometry system at the Centro Nacional de Aceleradores (CNA, Seville, Spain) to analyse Pu at environmental levels. The presence of Th traces in the Pu sample limits the sensitivity of the technique through the formation of the diatomic trication (ThC), of mass 244 u, which must be suppressed by adjusting the stripper gas pressure. APu background of 0.0075 fg (2 × 10 at) is demonstrated for samples that have undergone a chemical treatment. The reliability of the technique is proved through the analysis of three reference sediments provided by the International Atomic Energy Agency (IAEA-412, IAEA-465, IAEA-385). Pu results are complemented with Pu, Pu, Pu and U and their relative isotopic abundances are discussed.
PubMed: 38945105
DOI: 10.1016/j.jenvrad.2024.107485 -
Biomaterials Jun 2024Cell-laden bioprinting is a promising biofabrication strategy for regenerating bioactive transplants to address organ donor shortages. However, there has been little...
Cell-laden bioprinting is a promising biofabrication strategy for regenerating bioactive transplants to address organ donor shortages. However, there has been little success in reproducing transplantable artificial organs with multiple distinctive cell types and physiologically relevant architecture. In this study, an omnidirectional printing embedded network (OPEN) is presented as a support medium for embedded 3D printing. The medium is state-of-the-art due to its one-step preparation, fast removal, and versatile ink compatibility. To test the feasibility of OPEN, exceptional primary mouse hepatocytes (PMHs) and endothelial cell line-C166, were used to print hepatospheroid-encapsulated-artificial livers (HEALs) with vein structures following predesigned anatomy-based printing paths in OPEN. PMHs self-organized into hepatocyte spheroids within the ink matrix, whereas the entire cross-linked structure remained intact for a minimum of ten days of cultivation. Cultivated HEALs maintained mature hepatic functions and marker gene expression at a higher level than conventional 2D and 3D conditions in vitro. HEALs with C166-laden vein structures promoted endogenous neovascularization in vivo compared with hepatospheroid-only liver prints within two weeks of transplantation. Collectively, the proposed platform enables the manufacture of bioactive tissues or organs resembling anatomical architecture, and has broad implications for liver function replacement in clinical applications.
PubMed: 38944968
DOI: 10.1016/j.biomaterials.2024.122681 -
Food Chemistry Jun 2024Rose polyphenols, key functional components in roses, require adequate bioaccessibility for their health benefits, subject to influence by food components and...
Rose polyphenols, key functional components in roses, require adequate bioaccessibility for their health benefits, subject to influence by food components and processing. Investigating the impact of various thermal sterilization methods on the bioaccessibility of rose polyphenols in rose tea with milk and the underlying mechanisms, our findings indicated a significant increase in bioaccessibility following treatment at 85 °C/30 min. Conversely, 121 °C/15 min treatment decreased bioaccessibility. Examining the interaction between β-casein in milk and rose polyphenols under different sterilization conditions, SEM and particle size analysis revealed binding, with fluorescence spectroscopy indicating non-covalent bonds. Binding forces followed the order 121 °C > 85 °C > 25 °C. Notably, at 85 °C, non-covalent binding improved polyphenol bioaccessibility, while the intensified binding at 121 °C decreased it. SDS-PAGE and amino acid analysis confirmed no covalent bond. This study establishes a theoretical basis for selecting thermal sterilization temperatures for milk-flower combinations, considering polyphenol bioaccessibility.
PubMed: 38944930
DOI: 10.1016/j.foodchem.2024.140248