BioRxiv : the Preprint Server For... Jun 2024Integration of neural interfaces with minimal tissue disruption in the brain is ideal to develop robust tools that can address essential neuroscience questions and...
Integration of neural interfaces with minimal tissue disruption in the brain is ideal to develop robust tools that can address essential neuroscience questions and combat neurological disorders. However, implantation of intracortical devices provokes severe tissue inflammation within the brain, which requires a high metabolic demand to support a complex series of cellular events mediating tissue degeneration and wound healing. Pericytes, peri-vascular cells involved in blood-brain barrier maintenance, vascular permeability, waste clearance, and angiogenesis, have recently been implicated as potential perpetuators of neurodegeneration in brain injury and disease. While the intimate relationship between pericytes and the cortical microvasculature have been explored in other disease states, their behavior following microelectrode implantation, which is responsible for direct blood vessel disruption and dysfunction, is currently unknown. Using two-photon microscopy we observed dynamic changes in the structure and function of pericytes during implantation of a microelectrode array over a 4-week implantation period. Pericytes respond to electrode insertion through transient increases in intracellular calcium and underlying constriction of capillary vessels. Within days following the initial insertion, we observed an influx of new, proliferating pericytes which contribute to new blood vessel formation. Additionally, we discovered a potentially novel population of reactive immune cells in close proximity to the electrode-tissue interface actively engaging in encapsulation of the microelectrode array. Finally, we determined that intracellular pericyte calcium can be modulated by intracortical microstimulation in an amplitude- and frequency-dependent manner. This study provides a new perspective on the complex biological sequelae occurring the electrode-tissue interface and will foster new avenues of potential research consideration and lead to development of more advanced therapeutic interventions towards improving the biocompatibility of neural electrode technology.
PubMed: 38915601
DOI: 10.1101/2024.06.11.598494 -
Analytical and Bioanalytical Chemistry Jun 2024The hormone Neuropeptide Y (NPY) plays critical roles in feeding, satiety, obesity, and weight control. However, its complex peptide structure has hindered the...
The hormone Neuropeptide Y (NPY) plays critical roles in feeding, satiety, obesity, and weight control. However, its complex peptide structure has hindered the development of fast and biocompatible detection methods. Previous studies utilizing electrochemical techniques with carbon fiber microelectrodes (CFMEs) have targeted the oxidation of amino acid residues like tyrosine to measure peptides. Here, we employ the modified sawhorse waveform (MSW) to enable voltammetric identification of NPY through tyrosine oxidation. Use of MSW improves NPY detection sensitivity and selectivity by reducing interference from catecholamines like dopamine, serotonin, and others compared to the traditional triangle waveform. The technique utilizes a holding potential of -0.2 V and a switching potential of 1.2 V that effectively etches and renews the CFME surface to simultaneously detect NPY and other monoamines with a sensitivity of 5.8 ± 0.94 nA/µM (n = 5). Furthermore, we observed adsorption-controlled, subsecond NPY measurements with CFMEs and MSW. The effective identification of exogenously applied NPY in biological fluids demonstrates the feasibility of this methodology for in vivo and ex vivo studies. These results highlight the potential of MSW voltammetry to enable fast, biocompatible NPY quantification to further elucidate its physiological roles.
PubMed: 38914733
DOI: 10.1007/s00216-024-05373-y -
Neuroscience Letters Jun 2024The nucleus accumbens (NAc) and the anterior limb of internal capsule (ALIC) are effective targets for treating addiction using deep brain stimulation (DBS). However,...
The nucleus accumbens (NAc) and the anterior limb of internal capsule (ALIC) are effective targets for treating addiction using deep brain stimulation (DBS). However, there have been no reports on the electrophysiological characteristics of addiction nuclei at the single-cell level in humans. This study aimed to investigate the electrical activity characteristics of neurons in the NAc and ALIC using Microelectrode Recording (MER) during DBS surgery in patients with addiction, and six patients with addiction were included (five with heroin addiction and one with alcohol addiction). The microelectrode recording trajectories were reconstructed and recording sites at different depths were determined by merging the pre- and post-operative images in the FrameLink system. The results showed that among the 256 neurons, 204 (80 %) were burst neurons. NAc neurons accounted for the majority (57 %), and the mean firing rate (MFR) was the highest (1.94 Hz). ALIC neurons accounted for the least (14 %), and MFR was the lowest (0.44 Hz). MFR increased after entering the NAc and decreased after exiting the ALIC. In the patients with addiction treated using DBS, the single-cell level electrophysiological characteristics of the different nuclei were found to be distinct along the surgical trajectory.
PubMed: 38914277
DOI: 10.1016/j.neulet.2024.137884 -
Journal of Visualized Experiments : JoVE Jun 2024Neuronal cultures have been a reference experimental model for several decades. However, 3D cell arrangement, spatial constraints on neurite outgrowth, and realistic...
Neuronal cultures have been a reference experimental model for several decades. However, 3D cell arrangement, spatial constraints on neurite outgrowth, and realistic synaptic connectivity are missing. The latter limits the study of structure and function in the context of compartmentalization and diminishes the significance of cultures in neuroscience. Approximating ex vivo the structured anatomical arrangement of synaptic connectivity is not trivial, despite being key for the emergence of rhythms, synaptic plasticity, and ultimately, brain pathophysiology. Here, two-photon polymerization (2PP) is employed as a 3D printing technique, enabling the rapid fabrication of polymeric cell culture devices using polydimethyl-siloxane (PDMS) at the micrometer scale. Compared to conventional replica molding techniques based on microphotolitography, 2PP micro-scale printing enables rapid and affordable turnaround of prototypes. This protocol illustrates the design and fabrication of PDMS-based microfluidic devices aimed at culturing modular neuronal networks. As a proof-of-principle, a two-chamber device is presented to physically constrain connectivity. Specifically, an asymmetric axonal outgrowth during ex vivo development is favored and allowed to be directed from one chamber to the other. In order to probe the functional consequences of unidirectional synaptic interactions, commercial microelectrode arrays are chosen to monitor the bioelectrical activity of interconnected neuronal modules. Here, methods to 1) fabricate molds with micrometer precision and 2) perform in vitro multisite extracellular recordings in rat cortical neuronal cultures are illustrated. By decreasing costs and future widespread accessibility of 2PP 3D-printing, this method will become more and more relevant across research labs worldwide. Especially in neurotechnology and high-throughput neural data recording, the ease and rapidity of prototyping simplified in vitro models will improve experimental control and theoretical understanding of in vivo large-scale neural systems.
Topics: Neurons; Printing, Three-Dimensional; Animals; Cell Culture Techniques; Dimethylpolysiloxanes; Polymerization; Rats
PubMed: 38912772
DOI: 10.3791/66142 -
Frontiers in Cardiovascular Medicine 2024There have been conflicting reports about the proarrhythmic risk of -synephrine (SYN). To address this, human induced pluripotent stem cell-derived cardiomyocytes...
Non-invasive assessment of proarrhythmic risks associated with isoprenaline and the dietary supplement ingredient synephrine using human induced pluripotent stem cell-derived cardiomyocytes.
BACKGROUND
There have been conflicting reports about the proarrhythmic risk of -synephrine (SYN). To address this, human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) combined with the microelectrode array (MEA) system have been utilized to assess arrhythmia risks, particularly in the context of adrenomimetic drugs.
AIM
This study aims to determine whether MEA recordings from hiPSC-CMs could predict the proarrhythmic risk of adrenomimetic drugs and to investigate the cardiovascular effects and mechanisms of SYN.
MATERIALS AND METHODS
We employed MEA recordings to assess the electrophysiological properties of hiPSC-CMs and conducted concentration-response analyses to evaluate the effects of SYN and Isoprenaline (ISO) on beating rate and contractility. A risk scoring system for proarrhythmic risks was established based on hiPSC-CMs in this study. ISO, a classic beta-adrenergic drug, was also evaluated. Furthermore, the study evaluated the risk of SYN and recorded the concentration-response of beating rate, contractility and the change in the presence or absence of selective β1, β2 and β3 adrenergic blockers.
RESULTS
Our results suggested that ISO carries a high risk of inducing arrhythmias, aligning with existing literature. SYN caused a 30% prolongation of the field potential duration (FPD) at a concentration of 206.326 μM, a change significantly different from baseline measurements and control treatments. The half maximal effective concentration (EC50) of SYN (3.31 μM) to affect hiPSC-CM beating rate is much higher than that of ISO (18.00 nM). The effect of SYN at an EC50 of 3.31 μM is about ten times more potent in hiPSC-CMs compared to neonatal rat cardiomyocytes (34.12 μM). SYN increased the contractility of cardiomyocytes by 29.97 ± 11.65%, compared to ISO's increase of 50.56 ± 24.15%. β1 receptor blockers almost eliminated the beating rate increase induced by both ISO and SYN, while neither β2 nor β3 blockers had a complete inhibitory effect.
CONCLUSION
The MEA and hiPSC-CM system could effectively predict the risk of adrenomimetic drugs. The study concludes that the proarrhythmia risk of SYN at conventional doses is low. SYN is more sensitive in increasing beating rate and contractility in human cardiomyocytes compared to rats, primarily activating β1 receptor.
PubMed: 38911513
DOI: 10.3389/fcvm.2024.1407138 -
Biosensors & Bioelectronics Oct 2024In recent years, in vitro three-dimensional (3D) neuronal network models utilizing extracellular matrices have been advancing. To understand the network activity from...
In recent years, in vitro three-dimensional (3D) neuronal network models utilizing extracellular matrices have been advancing. To understand the network activity from these models, attempts have been made to measure activity in multiple regions simultaneously using a microelectrode array (MEA). Although there hve been many attempts to measure the activity of 3D networks using 2-dimensional (2D) MEAs, the physical coupling between the 3D network and the microelectrodes was not stable and needed to be improved. In this study, we proposed a neuronal cluster interface that improves the active channel ratio of commercial 2D MEAs, enabling reliable measurement of 3D network activity. To achieve this, neuronal clusters, which consist of a small number of neurons, were patterned on microelectrodes and used as mediators to transmit the signal between the 3D network and the microelectrodes. We confirmed that the patterned neuronal clusters enhanced the active channel ratio and SNR(signal-to-noise-ratio) about 3D network recording and stimulation for a month. Our interface was able to functionally connect with 3D networks and measure the 3D network activity without significant alternation of activity characteristics. Finally, we demonstrated that our interface can be used to analyze the differences in the dynamics of 3D and 2D networks and to construct the 3D clustered network. This method is expected to be useful for studying the functional activity of various 3D neuronal network models, offering broad applications for the use of these models.
Topics: Microelectrodes; Neurons; Nerve Net; Animals; Biosensing Techniques; Rats; Action Potentials; Cells, Cultured; Equipment Design
PubMed: 38905857
DOI: 10.1016/j.bios.2024.116507 -
Analytical Methods : Advancing Methods... Jun 2024A nanoporous gold microelectrode (NPG-μE) was fabricated and used for Pb(II) detection in seawater samples square wave anodic stripping voltammetry (SWASV). The Au...
A nanoporous gold microelectrode (NPG-μE) was fabricated and used for Pb(II) detection in seawater samples square wave anodic stripping voltammetry (SWASV). The Au microelectrode (Au-μE) was fabricated by embedding a gold microfiber into a Pasteur pipette, and its surface was further modified by an anodization-electrochemical reduction (A-ECR) method, yielding the NPG-μE. The fabricated electrodes were characterized by cyclic voltammetry (CV) and field emission scanning electron microscopy (FE-SEM) for electrochemical and structural morphological investigations. SWASV results show a Pb(II) stripping peak at around -0.05 V Ag/AgCl, sat. KCl, which is unusual for common Pb(II) detection (typically occurring at around -0.40 V) in anodic stripping voltammetry (ASV) analysis. The Pb(II) detection at less negative stripping potential is more beneficial. Hence, it exhibited anti-interference properties with Cd(II), which is attributed to the preferential deposition and stripping of the target analyte on the low-indexed crystal planes of the NPG structure. The calibration plot obtained by SWASV was linear in the concentration range of 0.1-10 μM, and the detection limit was found to be 57 nM (correlation coefficient of 0.9974). The NPG microsensor presented a 15-fold enhanced current response compared to Au-μE, with excellent sensitivity (27.2 μA μM cm). The application of the NPG microsensor was examined by detecting Pb(II) in seawater samples, and a satisfactory performance was obtained.
PubMed: 38904354
DOI: 10.1039/d4ay00698d -
ACS Nano Jul 2024Although neuronal network models hold great potential for advancing neuroscience research, with the capacity to provide fundamental insights into mechanisms underlying...
Although neuronal network models hold great potential for advancing neuroscience research, with the capacity to provide fundamental insights into mechanisms underlying neuronal functions, the dynamics of cell communication within such networks remain poorly understood. Here, we develop a customizable, polymer modified three-dimensional gold microelectrode array with sufficient stability for high signal-to-noise, long-term, neuronal recording of cultured networks. By using directed spatial and temporal patterns of electrical stimulation of cells to explore synaptic-based communication, we monitored cell network dynamics over 3 weeks, quantifying communication capability using correlation heatmaps and mutual information networks. Analysis of synaptic delay and signal speed between cells enabled us to establish a communication connectivity model. We anticipate that our discoveries of the dynamic changes in communication across the neuronal network will provide a valuable tool for future studies in understanding health and disease as well as in developing effective platforms for evaluating therapies.
Topics: Microelectrodes; Gold; Animals; Neurons; Nerve Net; Cell Communication; Rats; Cells, Cultured
PubMed: 38902594
DOI: 10.1021/acsnano.4c03983 -
Angewandte Chemie (International Ed. in... Jun 2024Developing real-time, dynamic, and in situ analytical methods with high spatial and temporal resolutions is crucial for exploring biochemical processes in the brain....
Developing real-time, dynamic, and in situ analytical methods with high spatial and temporal resolutions is crucial for exploring biochemical processes in the brain. Although in vivo electrochemical methods based on carbon fiber (CF) microelectrodes are effective in monitoring neurochemical dynamics during physiological and pathological processes, complex post modification hinders large-scale productions and widespread neuroscience applications. Herein, we develop a general strategy for the in situ engineering of carbon-based materials to mass-produce functional CFs by introducing polydopamine to anchor zeolitic imidazolate frameworks as precursors, followed by one-step pyrolysis. This strategy demonstrates exceptional universality and design flexibility, overcoming complex post-modification procedures and avoiding the delamination of the modification layer. This simplifies the fabrication and integration of functional CF-based microelectrodes. Moreover, we design highly stable and selective H+, O2, and ascorbate microsensors and monitor the influence of CO2 exposure on the O2 content of the cerebral tissue during physiological and ischemia-reperfusion pathological processes.
PubMed: 38898543
DOI: 10.1002/anie.202407063 -
Advanced Materials (Deerfield Beach,... Jun 2024Despite of the substantial potential of human-derived retinal organoids, the degeneration of retinal ganglion cells (RGCs) during maturation limits their utility in...
Despite of the substantial potential of human-derived retinal organoids, the degeneration of retinal ganglion cells (RGCs) during maturation limits their utility in assessing the functionality of later-born retinal cell subtypes. Additionally, conventional analyses primarily rely on fluorescent emissions, which limits the detection of actual cell functionality while risking damage to the three-dimensional (3D) cytoarchitecture of organoids. Here, we present an electrophysiological analysis to monitor RGC development in early to mid-stage retinal organoids, and compare distinct features with fully-mature mouse retina. Our approach utilizes high-resolution 3D printing of liquid-metal microelectrodes, enabling precise targeting of specific inner retinal layers within organoids. The adaptable distribution and softness of these microelectrodes facilitate the spatiotemporal recording of inner retinal signals. Our study not only demonstrates the functional properties of RGCs in retinal organoid development but also provides insights into their synaptic connectivity, reminiscent of fetal native retinas. Further comparison with fully-mature mouse retina in vivo verifies the organoid features, highlighting the potential of early-stage retinal organoids in biomedical research. This article is protected by copyright. All rights reserved.
PubMed: 38896876
DOI: 10.1002/adma.202404428