-
Journal of Cosmetic Dermatology Jun 2024Botulinum toxin A (BoNT-A) is widely utilized in the management of hypertrophic and keloid scars. One proposed mechanism for scar prevention involves the inhibition of...
BACKGROUND
Botulinum toxin A (BoNT-A) is widely utilized in the management of hypertrophic and keloid scars. One proposed mechanism for scar prevention involves the inhibition of fibroblast migration in scars by BoNT-A. However, the data regarding the effect of BoNT-A on the migration of normal human dermal fibroblasts (NHDF) is limited.
OBJECTIVES
The aim of this study was to investigate the inhibitory effect of different types and dilutions of BoNT-A on the migration of NHDF.
METHODS
In vitro scratch wound assay, NHDF cells were cultured, incubated, and subjected to scratching using a sterile tip. Subsequently, the scratched NHDF monolayer was treated with different types of BoNT-A, including onabotulinumtoxinA (ONA), incobotulinumtoxinA (INCO), prabotulinumtoxinA (PRABO), or letibotulinumtoxinA (LETI), at varying concentrations of 10, 20, 25, 40, 50, and 100 units/milliliter (U/mL). Additionally, abobotulinumtoxinA (ABO) was administered at concentrations of 33, 50, 66, 71, 100, 150, 300, and 500 U/mL. Normal saline solution (NSS) served as a negative control. The extent of NHDF migration was evaluated by comparing each dilution of BoNT-A with the controls using high-content imaging at the 48-h time point. Furthermore, the viability of the of NHDF was assessed.
RESULTS
The concentrations of 25, 40, and 50 U/mL of ONA (p < 0.001) and 25 U/mL of LETI (p < 0.05) demonstrated significantly inhibited NHDF migration in comparison to the control group. Conversely, all dilutions of PRABO, INCO, and ABO exhibited comparable NHDF migration to that of the control group. Regarding NHDF viability, no significant decrease was observed across any of the BoNT-A types and dilutions.
CONCLUSION
Different types and dilutions of BoNT-A demonstrated variable inhibitory effects on NHDF migration in vitro. The selection of BoNT-A formulation may significantly impact the clinical outcome of scar prevention related to fibroblast migration.
PubMed: 38898766
DOI: 10.1111/jocd.16406 -
Huan Jing Ke Xue= Huanjing Kexue Jun 2024In recent years, research on microplastics has mostly focused on thermoplastic materials, and there is a lack of research on the pollution status and environmental...
In recent years, research on microplastics has mostly focused on thermoplastic materials, and there is a lack of research on the pollution status and environmental behavior of tire microplastics, a type of rubber elastomers. In order to investigate the aging and small-sized particles release characteristics of tire microplastics in various environmental media, the aging process of two different tire microplastics, one for cars and the other for electric bicycles, was simulated in dry and aquatic environments under laboratory conditions. The results showed that the tire microplastics would be aged after 30 d of UV illumination, which was manifested by the roughness of the surface and the appearance of cracks and flaking. The Fourier infrared spectra showed that the carbonyl index of the surface also increased. In addition, tire microplastics released a large number of small sub-micron particles under the influence of UV illumination and hydrodynamic action, and the number of particles released from car tire microplastics in aquatic environments reached 694.8 million particles per milliliter of solution at 30 d of the UV light condition, among which 694.6 million particles with a particle size of less than 1 μm were released, which was approximately 100 times of that in the dark condition. The study showed that tire microplastics in aquatic environments were more susceptible to aging and released more small particles under light conditions and that car tire microplastics released more small particles than electric bicycle tire microplastics, posing ecological and environmental risks.
PubMed: 38897789
DOI: 10.13227/j.hjkx.202306221 -
European Review For Medical and... Jun 2024Monitoring Jackson Pratt and Hemovac drains plays a crucial role in assessing a patient's recovery and identifying potential postoperative complications. Accurate and...
OBJECTIVE
Monitoring Jackson Pratt and Hemovac drains plays a crucial role in assessing a patient's recovery and identifying potential postoperative complications. Accurate and regular monitoring of the blood volume in the drain is essential for making decisions about patient care. However, transferring blood to a measuring cup and recording it is a challenging task for both patients and doctors, exposing them to bloodborne pathogens such as the human immunodeficiency virus (HIV), hepatitis B virus (HBV), and hepatitis C virus (HCV). To automate the recording process with a non-contact approach, we propose an innovative approach that utilizes deep learning techniques to detect a drain in a photograph, compute the blood level in the drain, estimate the blood volume, and display the results on both web and mobile interfaces.
MATERIALS AND METHODS
Our system employs semantic segmentation on images taken with mobile phones to effectively isolate the blood-filled portion of the drain from the rest of the image and compute the blood volume. These results are then sent to mobile and web applications for convenient access. To validate the accuracy and effectiveness of our system, we collected the Drain Dataset, which consists of 1,004 images taken under various background and lighting conditions.
RESULTS
With an average error rate of less than 5% in milliliters, our proposed approach achieves highly accurate blood level detection and estimation, as demonstrated by our trials on this dataset. The system also exhibits robustness to variations in lighting conditions and drain shapes, ensuring its applicability in different clinical scenarios.
CONCLUSIONS
The proposed automated blood volume estimation system can significantly reduce the time and effort required for manual measurements, enabling healthcare professionals to focus on other critical tasks. The dataset and annotations are available at: https://www.kaggle.com/datasets/ayenahin/liquid-volume-detection-from-drain-images and the code for the web application is available at https://github.com/itsjustaplant/AwesomeProject.git.
Topics: Humans; Decision Support Systems, Clinical; Drainage; Blood Volume; Deep Learning; Blood Volume Determination
PubMed: 38884505
DOI: 10.26355/eurrev_202406_36375 -
Cureus May 2024Pericardial effusion, a clinical condition characterized by an abnormal accumulation of fluid in the pericardial cavity, has multiple etiological factors. One of the...
Pericardial effusion, a clinical condition characterized by an abnormal accumulation of fluid in the pericardial cavity, has multiple etiological factors. One of the prominent causes is malignant effusion. The patient is a 69-year-old female with a past medical history of Crohn's disease, melanoma status post-resection, and osteoarthritis. She presented with complaints of abdominal discomfort, shortness of breath on exertion, and lower extremity swelling for the past 2-3 days. She was recently discharged four days before this visit after being treated for a viral infection. A physical examination was significant for tachycardia, muffled heart sounds, abdominal distention, and bilateral lower extremity swelling. Labs were in the normal range except for elevated liver enzymes and sodium of 130 mmol/L. A chest X-ray revealed a small bilateral effusion; a bedside echocardiogram showed an ejection fraction greater than 70% and a large pericardial effusion >2 cm, consistent with cardiac tamponade. Emergent pericardiocentesis was performed with the drainage of 250 milliliters of hemorrhagic fluid, which was sent for diagnostic studies. Post-procedure echo on the next day showed an EF of 35-40% and no recurrent pericardial effusion. The workup for connective tissue disease was negative except for elevated antinuclear antibodies (ANA). CT of the abdomen and pelvis revealed gastric wall thickening with no solid organ mass. Her pericardial fluid studies were consistent with exudative etiology and positive for atypical lymphoid cells, leading to the diagnosis of diffuse large B-cell lymphoma. Diffuse large B-cell lymphoma is the most common type of non-Hodgkin lymphoma. Malignant pericardial effusion is common due to solid organ malignancy; however, it is rare with diffuse large B cell lymphoma (DLBCL). We present an intriguing case where pericardial effusion was the precursor to the eventual diagnosis of DLBCL, highlighting the complexity and diverse manifestations of this lymphoma subtype.
PubMed: 38882999
DOI: 10.7759/cureus.60418 -
Analytical Chemistry Jun 2024Virus detection is highly important; the last several years, since the onset of the SARS-CoV-2 pandemic, have highlighted a weakness in the field: the need for highly...
Virus detection is highly important; the last several years, since the onset of the SARS-CoV-2 pandemic, have highlighted a weakness in the field: the need for highly specialized and complex methodology for sensitive virus detection, which also manifests as sacrifices in limits of detection made to achieve simple and rapid sensing. Surface-enhanced Raman spectroscopy (SERS) has the potential to fill this gap, and two novel approaches to the development of a detection scheme are presented in this study. First, the physical entrapment of vesicular stomatitis virus (VSV) and additional virus-like particles through substrate design to localize virus analytes into SERS hotspots is explored. Then, the use of nonspecific linear polymers as affinity agents to facilitate polymer-enabled capture of the VSV for SERS detection is studied. Quantitative detection of the VSV is achieved down to 10 genetic copies per milliliter with an of 0.987 using the optimized physical entrapment method. Physical entrapment of two more virus-like particles is demonstrated with electron microscopy, and distinctive SERS fingerprints are shown. This study shows great promise for the further exploration of label-free virus detection methods involving thoughtful substrate design and unconventional affinity agents.
Topics: Spectrum Analysis, Raman; Polymers; SARS-CoV-2; COVID-19; Virion; Humans; Surface Properties; Limit of Detection
PubMed: 38873697
DOI: 10.1021/acs.analchem.4c01117 -
Diving and Hyperbaric Medicine Jun 2024Blood alcohol concentrations above defined levels are detrimental to cognitive performance. Empirical and published evidence suggest that nitrogen narcosis is analogous...
Blood alcohol concentrations above defined levels are detrimental to cognitive performance. Empirical and published evidence suggest that nitrogen narcosis is analogous to alcohol intoxication with both impairing prefrontal cortex function. Nitrogen narcosis is also known to have been a factor in fatal accidents. To examine the effects of nitrogen narcosis, a recent publication used the Iowa Gambling Task tool, to simulate dynamic real-life risky decision-making behaviour. If the reported outcomes are corroborated in larger rigorously designed studies it is likely to provide further evidence that divers may well experience the negative effects of a 'narcotic agent', even at relatively shallow depths. These deleterious effects may occur regardless of diving experience, aptitude or professional status. In 1872, English law made it an offence to be 'drunk' whilst in charge of horses, carriages, cattle and steam engines. Understanding the danger was easy, establishing who is 'drunk' in the eyes of the court required a legal definition. Driving above a 'legal limit' for alcohol was made illegal in the United Kingdom in 1967. The limit was set at 80 milligrams of alcohol per 100 millilitres of blood. It took just short of one hundred years to get from first introducing a restriction to specific activities, whilst under the influence of alcohol, to having a clear and well-defined enforceable law. The question surely is whether our modern society will tolerate another century before legally defining safe parameters for nitrogen narcosis?
Topics: Humans; Diving; Inert Gas Narcosis; Driving Under the Influence; United Kingdom; Alcoholic Intoxication; Blood Alcohol Content
PubMed: 38870957
DOI: 10.28920/dhm54.2.137-139 -
The Journal of Physical Chemistry... Jun 2024The cathodic mechanism of Li-N batteries is similar to Li-mediated N reduction (LiNR). Herein, the Li-N, LiNR, and Cu-Li battery were amalgamated to a milliliter-scale...
The cathodic mechanism of Li-N batteries is similar to Li-mediated N reduction (LiNR). Herein, the Li-N, LiNR, and Cu-Li battery were amalgamated to a milliliter-scale Cu(N)-Li system. The utilization of a lithium anode with lithium oxidation reaction (LiOR), ensures an uninterrupted supply of lithium ions to active N. LiOR not only enhances electrolyte stability but also reduces voltage by stripping Li ions, in contrast to the inert platinum anode, commonly employed in LiNR. Notably, an unusual observation of ammonia accumulation within the anode chamber elucidates the presence and role of reaction intermediates. The charging process aimed at lithium regeneration faces high polarization, and a cycling procedure involving low-current charging was proposed to improve cycling. This study integrates insights from three distinct research directions to leverage their respective advantages and scientific insights. The Li-N battery emerges as a highly advantageous strategy for ammonia synthesis due to the progressiveness of lithium anode.
PubMed: 38865163
DOI: 10.1021/acs.jpclett.4c01328 -
ACS Applied Materials & Interfaces Jun 2024Advancing iontronics with precisely controlled ion transport is fundamentally important to bridge external organic electronics with the biosystem. This long-standing...
Advancing iontronics with precisely controlled ion transport is fundamentally important to bridge external organic electronics with the biosystem. This long-standing goal, however, is thus far limited by the trade-off between the active ion electromigration and idle diffusion leakage in the (semi)crystalline film. Here, we presented a mixed-orientation strategy by blending a conjugated polymer, allowing for simultaneously high ion electromigration efficiency and low leakage. Our studies revealed that edge-on aggregation with a significant percolative pathway exhibits much higher ion permeability than that of the face-on counterpart but encounters pronounced leakage diffusion. Through carefully engineering the mixed orientations, the polymer composite demonstrated an ideal switchable ion-transport behavior, achieving a remarkably high electromigration efficiency exceeding one quadrillion ions per milliliter per minute and negligible idle leakage. This proof of concept, validated by drug release in a skin-conformable organic electronic ion pump (OEIP), offers a rational approach for the development of multifunctional iontronic devices.
PubMed: 38862274
DOI: 10.1021/acsami.4c04485 -
ACS Applied Materials & Interfaces Jun 2024This paper reports a microfluidic device for the electrochemical and plasmonic detection of cardiac myoglobin (cMb) and cardiac troponin I (cTnI) with noticeable limits...
This paper reports a microfluidic device for the electrochemical and plasmonic detection of cardiac myoglobin (cMb) and cardiac troponin I (cTnI) with noticeable limits of detection (LoD) as low as a few picograms per milliliter (pg/mL) ranges, achieved in a short detection time. The device features two working electrodes, each with a mesoporous NiVO nanoscaffold grafted with reduced graphene oxide (rGO) that improves the interaction of diffusing analyte molecules with the sensing surface by providing a high surface area and reaction kinetics. Electrochemical studies reveal sensitivities as high as 9.68 μA ng/mL and a LoD of 2.0 pg/mL for cTnI, and 8.98 μA ng/mL and 4.7 pg/mL for cMb. Additionally, the surface plasmon resonance (SPR) studies demonstrate a low-level LoD of 8.8 pg/mL for cMb and 7.3 pg/mL for cTnI. The dual-modality sensor enables dynamic tracking of kinetic antigen-antibody interactions during sensing, self-verification through providing signals of two modes, and reduced false readout. This study demonstrates the complementary nature of the electrochemical and SPR modes in biosensing, with the electrochemical mode being highly sensitive and the SPR mode providing superior tracking of molecular recognition behaviors. The presented sensor represents a significant innovation in cardiovascular disease management and can be applied to monitor other clinically important biomolecules.
Topics: Myocardial Infarction; Troponin I; Graphite; Electrochemical Techniques; Myoglobin; Surface Plasmon Resonance; Humans; Porosity; Biosensing Techniques; Limit of Detection; Lab-On-A-Chip Devices; Nanostructures
PubMed: 38860871
DOI: 10.1021/acsami.4c01398 -
Optics Express May 2024A spectrometer built using an external cavity pulsed quantum cascade laser is described. The spectrometer has a tuning range from 10 - 13 µm (1,000 - 769 cm) and is...
A spectrometer built using an external cavity pulsed quantum cascade laser is described. The spectrometer has a tuning range from 10 - 13 µm (1,000 - 769 cm) and is designed to target volatile organic compounds (VOCs) which often exhibit water-free molecular absorption within the region. The spectrometer utilizes a hollow silica waveguide gas cell which has an internal volume of a few millilitres, a fast response time (∼1 s), and is advantageous when only low sample volumes, similar to the cell volume, are available. Propane is used as a test gas because it is easy to handle, and its spectral profile is comparable to VOCs of interest. Its absorption in the region is primarily within the ν band which spans from 10.55 - 11.16 µm (948 - 896 cm). Spectral measurements at a range of concentrations show good linearity and an Allan deviation of absorbance values recorded over a 100-minute period indicates a minimum detectable absorbance of 3.5×10 at an integration time of 75 s.
PubMed: 38858996
DOI: 10.1364/OE.521695