Nature Communications Jun 2024Untethered miniature soft robots have significant application potentials in biomedical and industrial fields due to their space accessibility and safe human interaction....
Untethered miniature soft robots have significant application potentials in biomedical and industrial fields due to their space accessibility and safe human interaction. However, the lack of selective and forceful actuation is still challenging in revolutionizing and unleashing their versatility. Here, we propose a focused ultrasound-controlled phase transition strategy for achieving millimeter-level spatially selective actuation and Newton-level force of soft robots, which harnesses ultrasound-induced heating to trigger the phase transition inside the robot, enabling powerful actuation through inflation. The millimeter-level spatial resolution empowers single robot to perform multiple tasks according to specific requirements. As a concept-of-demonstration, we designed soft robot for liquid cargo delivery and biopsy robot for tissue acquisition and patching. Additionally, an autonomous control system is integrated with ultrasound imaging to enable automatic acoustic field alignment and control. The proposed method advances the spatiotemporal response capability of untethered miniature soft robots, holding promise for broadening their versatility and adaptability.
Topics: Robotics; Equipment Design; Humans; Ultrasonic Waves; Phase Transition; Ultrasonography
PubMed: 38890294
DOI: 10.1038/s41467-024-49148-6 -
Beilstein Journal of Nanotechnology 2024Hair, or hair-like fibrillar structures, are ubiquitous in biology, from fur on the bodies of mammals, over trichomes of plants, to the mastigonemes on the flagella of... (Review)
Review
Hair, or hair-like fibrillar structures, are ubiquitous in biology, from fur on the bodies of mammals, over trichomes of plants, to the mastigonemes on the flagella of single-celled organisms. While these long and slender protuberances are passive, they are multifunctional and help to mediate interactions with the environment. They provide thermal insulation, sensory information, reversible adhesion, and surface modulation (e.g., superhydrophobicity). This review will present various functions that biological hairs have been discovered to carry out, with the hairs spanning across six orders of magnitude in size, from the millimeter-thick fur of mammals down to the nanometer-thick fibrillar ultrastructures on bateriophages. The hairs are categorized according to their functions, including protection (e.g., thermal regulation and defense), locomotion, feeding, and sensing. By understanding the versatile functions of biological hairs, bio-inspired solutions may be developed across length scales.
PubMed: 38887525
DOI: 10.3762/bjnano.15.55 -
Frontiers in Oncology 2024Glioblastoma (grade IV) is the most aggressive primary brain tumor in adults, representing one of the biggest therapeutic challenges due to its highly aggressive nature....
INTRODUCTION
Glioblastoma (grade IV) is the most aggressive primary brain tumor in adults, representing one of the biggest therapeutic challenges due to its highly aggressive nature. In this study, we investigated the impact of millimeter waves on tridimensional glioblastoma organoids derived directly from patient tumors. Our goal was to explore novel therapeutic possibilities in the fight against this challenging disease.
METHODS
The exposure setup was meticulously developed in-house, and we employed a comprehensive dosimetry approach, combining numerical and experimental methods. Biological endpoints included a global transcriptional profiling analysis to highlight possible deregulated pathways, analysis of cell morphological changes, and cell phenotypic characterization which are all important players in the control of glioblastoma progression.
RESULTS AND DISCUSSION
Our results revealed a significant effect of continuous millimeter waves at 30.5 GHz on cell proliferation and apoptosis, although without affecting the differentiation status of glioblastoma cells composing the organoids. Excitingly, when applying a power level of 0.1 W (Root Mean Square), we discovered a remarkable (statistically significant) therapeutic effect when combined with the chemotherapeutic agent Temozolomide, leading to increased glioblastoma cell death. These findings present a promising interventional window for treating glioblastoma cells, harnessing the potential therapeutic benefits of 30.5 GHz CW exposure. Temperature increase during treatments was carefully monitored and simulated with a good agreement, demonstrating a negligible involvement of the temperature elevation for the observed effects. By exploring this innovative approach, we pave the way for improved future treatments of glioblastoma that has remained exceptionally challenging until now.
PubMed: 38884089
DOI: 10.3389/fonc.2024.1307516 -
Ophthalmology Science 2024This study aimed to propose a fully automatic eyelid measurement system and compare the contours of both the upper and lower eyelids of normal individuals according to...
PURPOSE
This study aimed to propose a fully automatic eyelid measurement system and compare the contours of both the upper and lower eyelids of normal individuals according to age and gender.
DESIGN
Prospective study.
PARTICIPANTS
Five hundred and forty healthy Chinese aged 0 to 79 years in a tertiary hospital were included.
METHODS
Facial images in the primary gazing position were used to train and test the proposed automatic system for eye recognition and eye segmentation. According to the 10-millimeter diameter circular marker, measurements were transformed from pixel sizes into factual distances.
MAIN OUTCOME MEASURES
Midpupil lid distances (MPLDs) every 15° of all participants were automatically measured in both genders (30 males and 30 females in each age group) by the proposed deep learning (DL)-based system. Intraclass correlation coefficients (ICCs) were performed to assess the agreement between the automatic and manual margin reflex distances (MRDs). The eyelid contour, eyelid asymmetry, and palpebral fissure obliquity were analyzed using MPLD, temporal-versus-nasal MPLD ratio, and the angle between the inner and outer canthi, respectively.
RESULTS
The measurement of MRDs by the automatic system excellently agreed with that of the expert, with ICCs ranging from 0.863 to 0.886. As the age of the participants increased, the values of MPLDs reached a peak in those in their 20s or 30s and then gradually decreased at all angles. The temporal sector showed greater changes in MPLDs than the nasal sector, and the changes were more significant in females than in males. The maximum value of palpebral fissure obliquity appeared before 10 years in both genders and remained relatively stable after the 20s ( > 0.05).
CONCLUSIONS
The proposed DL-based eyelid analysis system allowed automatic, accurate, and comprehensive measurement of the eyelid contour. The refinement of eyelid shape quantification could be beneficial for future objective assessment preocular and postocular plastic surgery.
FINANCIAL DISCLOSURES
The authors have no proprietary or commercial interest in any materials discussed in this article.
PubMed: 38881605
DOI: 10.1016/j.xops.2024.100518 -
Methods (San Diego, Calif.) Jun 2024Magnetic technology has been a hotspot of neuromodulation research in recent years. However, magnetic coil is limited by their size, and it is impossible to realize...
Magnetic technology has been a hotspot of neuromodulation research in recent years. However, magnetic coil is limited by their size, and it is impossible to realize precise targeted magnetic stimulation to the target area at the cellular scale. To this end, this study designs a 1 × 4 array micro-magnetic stimulation (μMS) device with four sub-millimeter-sized elements, enabling precise magnetic stimulation of the CA1-CA3-DG tri-synaptic positions in the rat hippocampal region. First, it is determined that 70 KHz/2 mT/1 min magnetic stimulation parameter has a modulatory effect on the long-term potentiation (LTP) of Schaffer-CA1 in rat hippocampus. Then, a 1 × 4 array μMS device is used to perform magnetic stimulation at 70 KHz/2 mT/1 min, targeting the CA1, CA3, and DG regions individually with single-point magnetic stimulation; and multi-region magnetic stimulation is applied to the double-point targeting regions of CA1-CA3, CA1-DG, and CA3-DG, as well as the triple-point targeting region of CA1-CA3-DG, so as to investigate the regulation of LTP by single-region magnetic stimulation and multi-region magnetic stimulation. The experimental results indicate that, in the case of single-region magnetic stimulation, the magnitude of the increase in LTP in the CA1 region is the greatest, followed by the CA3 region, while the effect of magnetic stimulation on the DG region is less pronounced. In multi-region magnetic stimulation, synergistic magnetic stimulation of the three-point CA1-CA3-DG results in a greater increase in LTP compared to stimulation of two individual areas, and the enhancement of LTP induction with multi-region magnetic stimulation surpasses that of single-region stimulation. This study has implications for the collaborative targeted magnetic stimulation application of arrayed micro-magnetic devices.
PubMed: 38880432
DOI: 10.1016/j.ymeth.2024.06.004 -
Advanced Healthcare Materials Jun 2024Rapid and accurate assessment of conditions characterized by altered blood flow, cardiac blood pooling, or internal bleeding is crucial for diagnosing and treating... (Review)
Review
Rapid and accurate assessment of conditions characterized by altered blood flow, cardiac blood pooling, or internal bleeding is crucial for diagnosing and treating various clinical conditions. While widely used imaging modalities such as magnetic resonance imaging (MRI), computed tomography (CT), and ultrasound offer unique diagnostic advantages, they fall short for specific indications due to limited penetration depth and prolonged acquisition times. Magnetic particle imaging (MPI), an emerging tracer-based technique, holds promise for blood circulation assessments, potentially overcoming existing limitations with reduction in background signals and high temporal and spatial resolution, below the millimeter scale. Successful imaging of blood pooling and impaired flow necessitates tracers with diverse circulation half-lives optimized for MPI signal generation. Recent MPI tracers show potential in imaging cardiovascular complications, vascular perforations, ischemia, and stroke. The impressive temporal resolution and penetration depth also position MPI as an excellent modality for real-time vessel perfusion imaging via functional MPI (fMPI). This review summarizes advancements in optimized MPI tracers for imaging blood circulation and analyzes the current state of pre-clinical applications. This work discusses perspectives on standardization required to transition MPI from a research endeavor to clinical implementation and explore additional clinical indications that may benefit from the unique capabilities of MPI.
PubMed: 38879782
DOI: 10.1002/adhm.202400612 -
Journal of Colloid and Interface Science Jun 2024Ultralight graphene aerogels have gained extensive recognition in the impact protection field. However, attaining both elasticity and durability at low material density...
Ultralight graphene aerogels have gained extensive recognition in the impact protection field. However, attaining both elasticity and durability at low material density is challenging due to their intrinsic conflicts. Inspired by the mantis ootheca, we present a simultaneous improvement in the elasticity, durability, and density restrictions of ultralight graphene aerogels via constructing a multiscale honeycomb microstructure (MHM) within the graphene skeleton. This approach enables resulting graphene aerogel to achieve a strength per unit volume of 284.6 cm mg, the ability to recover its shape within 10 ms after an impact at 3.569 m/s, and maintain 97.2 % of its sample height after 20,000 cycles at 90 % strain. The operand analyses and calculation results reveal that the MHM structure facilitates this aerogel's dual-stage stress transfer pathway. Initially, the macroscale honeycomb structure (millimeter-scale) of the graphene aerogels bear and transmit stress to the surrounding regions, followed by the microscale honeycomb structure (micron-scale) deformation to convert stress kinetic energy into elastic potential energy. This two-stage stress transition mechanism of the MHM structure can effectively mitigate excessive local stress and suppress strain localization, thus providing remarkable elasticity and durability. Ultimately, the obtained graphene aerogel demonstrates promising applications as a fall height detection device and impact protective material.
PubMed: 38878368
DOI: 10.1016/j.jcis.2024.05.240 -
Scientific Reports Jun 2024As a form of body language, the gesture plays an important role in smart homes, game interactions, and sign language communication, etc. The gesture recognition methods...
As a form of body language, the gesture plays an important role in smart homes, game interactions, and sign language communication, etc. The gesture recognition methods have been carried out extensively. The existing methods have inherent limitations regarding user experience, visual environment, and recognition granularity. Millimeter wave radar provides an effective method for the problems lie ahead gesture recognition because of the advantage of considerable bandwidth and high precision perception. Interfering factors and the complexity of the model raise an enormous challenge to the practical application of gesture recognition methods as the millimeter wave radar is applied to complex scenes. Based on multi-feature fusion, a gesture recognition method for complex scenes is proposed in this work. We collected data in variety places to improve sample reliability, filtered clutters to improve the signal's signal-to-noise ratio (SNR), and then obtained multi features involves range-time map (RTM), Doppler-time map (DTM) and angle-time map (ATM) and fused them to enhance the richness and expression ability of the features. A lightweight neural network model multi-CNN-LSTM is designed to gestures recognition. This model consists of three convolutional neural network (CNN) for three obtained features and one long short-term memory (LSTM) for temporal features. We analyzed the performance and complexity of the model and verified the effectiveness of feature extraction. Numerous experiments have shown that this method has generalization ability, adaptability, and high robustness in complex scenarios. The recognition accuracy of 14 experimental gestures reached 97.28%.
PubMed: 38877076
DOI: 10.1038/s41598-024-64576-6 -
Physics in Medicine and Biology Jun 2024To fabricate and validate a novel focused collimator designed to spare normal tissue in a murine hemithoracic irradiation model using 250 MeV protons delivered at...
To fabricate and validate a novel focused collimator designed to spare normal tissue in a murine hemithoracic irradiation model using 250 MeV protons delivered at ultra-high dose rates (UHDRs) for preclinical FLASH-RT studies. Approach: A brass collimator was developed to shape 250 MeV UHDR protons from our Varian ProBeam. Six 13 mm apertures, of equivalent size to kV x-ray fields historically used to perform hemithorax irradiations, were precisely machined to match beam divergence, allowing concurrent hemithoracic irradiation of six mice while sparing the contralateral lung and abdominal organs. The collimated field profiles were characterized by film dosimetry, and a radiation survey of neutron activation was performed to ensure the safety of staff positioning animals. Main Results: The brass collimator produced 1.2 mm penumbrae radiation fields comparable to kV x-rays used in preclinical studies. The penumbrae in the six apertures are similar, with full-width half-maxima (FWHM) of 13.3 mm and 13.5 mm for the central and peripheral apertures, respectively. The collimator delivered a similar dose at an average rate of 52 Gy/s for all apertures. While neutron activation produces a high (0.2 mSv/h) initial ambient equivalent dose rate, a parallel work-flow in which imaging and setup are performed without the collimator ensures safety to staff. Significance: Scanned protons have the greatest potential for future translation of FLASH-RT in clinical treatments due to their ability to treat deep-seated tumors with high conformality. However, the Gaussian distribution of dose in proton spots produces wider lateral penumbrae compared to other modalities. This presents a challenge in small animal pre-clinical studies, where millimeter-scale penumbrae are required to precisely target the intended volume. Offering high-throughput irradiation of mice with sharp penumbrae, our novel collimator-based platform serves as an important benchmark for enabling large-scale, cost-effective radiobiological studies of the FLASH effect in murine models. .
PubMed: 38876112
DOI: 10.1088/1361-6560/ad589f -
Physiotherapy Research International :... Jul 2024This study aimed to evaluate the intrarater and interrater reliability of measuring Achilles tendon (AT) thickness using a digital caliper in patients with knee...
OBJECTIVE
This study aimed to evaluate the intrarater and interrater reliability of measuring Achilles tendon (AT) thickness using a digital caliper in patients with knee osteoarthritis.
METHODS
A cross-sectional survey was conducted at the Physiotherapy Department of Rabia Moon Hospital, involving the recruitment of 61 patients with knee osteoarthritis. Measurements were taken in millimeters at a 90-degree angle, approximately 5 cm from the attachment to the calcaneus, precisely where the ankle joint joins the medial malleolus. Two physical therapists conducted two testing sessions, separated by 7 days, to assess both the intrarater and interrater reliability of the digital caliper. During the second session, two raters simultaneously assessed the patients' responses on the digital caliper. The study analyzed reliability indices, including the Intraclass Correlation Coefficient (ICC) and Bland-Altman plot.
RESULTS
The study found high intrarater reliability for the digital caliper, with an ICC of 0.96 (95% confidence interval: 0.22, 0.99). For interrater reliability, the ICC was 0.98 (95% CI: 0.96, 0.98) in patients with knee OA. Additionally, both interrater and intrarater agreement for measuring AT thickness with the digital caliper fell within acceptable limits on 95% of occasions, as indicated by the Limits of Agreement values: 0.32 to -0.53 mm for interrater agreement and -0.35 to -0.04 mm for intrarater agreement.
CONCLUSIONS
Digital Calipers have been found to provide excellent intrarater and interrater reliability when used to measure AT thickness in patients with knee osteoarthritis (OA).
Topics: Humans; Osteoarthritis, Knee; Male; Female; Cross-Sectional Studies; Reproducibility of Results; Achilles Tendon; Middle Aged; Aged; Observer Variation
PubMed: 38873741
DOI: 10.1002/pri.2107