-
Clinical Neurophysiology : Official... Jun 2024Transcranial magnetic stimulation (TMS) can efficiently and robustly modulate synaptic plasticity, but little is known about how TMS affects functional connectivity...
OBJECTIVE
Transcranial magnetic stimulation (TMS) can efficiently and robustly modulate synaptic plasticity, but little is known about how TMS affects functional connectivity (rs-fMRI). Accordingly, this project characterized TMS-induced rsFC changes in depressed patients who received 3 days of left prefrontal intermittent theta burst stimulation (iTBS).
METHODS
rs-fMRI was collected from 16 subjects before and after iTBS. Correlation matrices were constructed from the cleaned rs-fMRI data. Electric-field models were conducted and used to predict pre-post changes in rs-fMRI. Site by orientation heatmaps were created for vectors centered on the stimulation site and a control site (contralateral motor cortex).
RESULTS
For the stimulation site, there was a clear relationship between both site and coil orientation, and connectivity changes. As distance from the stimulation site increased, prediction accuracy decreased. Similarly, as eccentricity from the optimal orientation increased, prediction accuracy decreased. The systematic effects described above were not apparent in the heatmap centered on the control site.
CONCLUSIONS
These results suggest that rs-fMRI following iTBS changes systematically as a function of the distribution of electrical energy delivered from the TMS pulse, as represented by the e-field model.
SIGNIFICANCE
This finding lays the groundwork for future studies to individualize TMS targeting based on how predicted rs-fMRI changes might impact psychiatric symptoms.
PubMed: 38945031
DOI: 10.1016/j.clinph.2024.06.007 -
Journal of Hazardous Materials Jun 2024Biodegradation of polyethylene (PE) plastics is environmentally friendly. To obtain the laccases that can efficiently degrade PE plastics, we generated 9 ancestral...
Biodegradation of polyethylene (PE) plastics is environmentally friendly. To obtain the laccases that can efficiently degrade PE plastics, we generated 9 ancestral laccases from 23 bacterial three-domain laccases through ancestral sequence reconstruction. The optimal temperatures of the ancestral laccases were between 60 °C-80 °C, while their optimal pHs were at 3.0 or 4.0. Without substrate pretreatment and mediator addition, all the ancestral laccases can degrade low-density polyethylene (LDPE) films at pH 7.0 and 60 °C. Among them, Anc52, which shared low sequence identity (18 %-41.7 %) with the reported PE-degrading laccases, was the most effective for LDPE degradation. After the catalytic reactions at 90 °C for 14 h, Anc52 (0.2 mg/mL) induced clear wrinkles and deep pits on the PE film surface detected by scanning electron microscope, and its carbonyl and hydroxyl indices reached 2.08 and 2.42, respectively. Then, we identified the residues 203 and 288 critical for PE degradation through site-directed mutation on Anc52. Moreover, Anc52 be activated by heat treatment (60 °C and 90 °C) at pH 7.0, which gave it a high catalytic efficiency (k/K= 191.73 mM·s) and thermal stability (half-life at 70 °C = 13.70 h). The ancestral laccases obtained here could be good candidates for PE biodegradation.
PubMed: 38944993
DOI: 10.1016/j.jhazmat.2024.135012 -
Biomaterials Jun 2024Cell-laden bioprinting is a promising biofabrication strategy for regenerating bioactive transplants to address organ donor shortages. However, there has been little...
Cell-laden bioprinting is a promising biofabrication strategy for regenerating bioactive transplants to address organ donor shortages. However, there has been little success in reproducing transplantable artificial organs with multiple distinctive cell types and physiologically relevant architecture. In this study, an omnidirectional printing embedded network (OPEN) is presented as a support medium for embedded 3D printing. The medium is state-of-the-art due to its one-step preparation, fast removal, and versatile ink compatibility. To test the feasibility of OPEN, exceptional primary mouse hepatocytes (PMHs) and endothelial cell line-C166, were used to print hepatospheroid-encapsulated-artificial livers (HEALs) with vein structures following predesigned anatomy-based printing paths in OPEN. PMHs self-organized into hepatocyte spheroids within the ink matrix, whereas the entire cross-linked structure remained intact for a minimum of ten days of cultivation. Cultivated HEALs maintained mature hepatic functions and marker gene expression at a higher level than conventional 2D and 3D conditions in vitro. HEALs with C166-laden vein structures promoted endogenous neovascularization in vivo compared with hepatospheroid-only liver prints within two weeks of transplantation. Collectively, the proposed platform enables the manufacture of bioactive tissues or organs resembling anatomical architecture, and has broad implications for liver function replacement in clinical applications.
PubMed: 38944968
DOI: 10.1016/j.biomaterials.2024.122681 -
Experimental & Molecular Medicine Jul 2024Over the past decade, the emergence of patient-derived tumor organoids (PDTOs) has broadened the repertoire of preclinical models and progressively revolutionized... (Review)
Review
Over the past decade, the emergence of patient-derived tumor organoids (PDTOs) has broadened the repertoire of preclinical models and progressively revolutionized three-dimensional cell culture in oncology. PDTO can be grown from patient tumor samples with high efficiency and faithfully recapitulates the histological and molecular characteristics of the original tumor. Therefore, PDTOs can serve as invaluable tools in oncology research, and their translation to clinical practice is exciting for the future of precision medicine in oncology. In this review, we provide an overview of methods for establishing PDTOs and their various applications in cancer research, starting with basic research and ending with the identification of new targets and preclinical validation of new anticancer compounds and precision medicine. Finally, we highlight the challenges associated with the clinical implementation of PDTO, such as its representativeness, success rate, assay speed, and lack of a tumor microenvironment. Technological developments and autologous cocultures of PDTOs and stromal cells are currently ongoing to meet these challenges and optimally exploit the full potential of these models. The use of PDTOs as standard tools in clinical oncology could lead to a new era of precision oncology in the coming decade.
PubMed: 38945959
DOI: 10.1038/s12276-024-01272-5 -
Journal of Oleo Science 2024Handwashing represents an important personal hygiene measure for preventing infection. Herein, we report the persistence of antibacterial and antiviral effects after...
Handwashing represents an important personal hygiene measure for preventing infection. Herein, we report the persistence of antibacterial and antiviral effects after handwashing with fatty acid salt-based hand soap. To this end, we developed a new in vitro test method to measure persistence, utilizing coacervation formed by anionic surfactants and cationic polymers to retain highly effective soap components against each bacterium and virus on the skin. Coacervation with fatty acid salts and poly diallyldimethylammonium chloride (PDADMAC) as a cationic polymer allowed the persistence of antibacterial and antiviral effects against E. coli, S. aureus, and influenza virus even 4 h after handwashing. Furthermore, we confirmed an increase in the number of residual components effective against each bacterium and virus on the skin. In summary, the current findings describe an effective approach for enhancing the protective effects of handwashing.
Topics: Soaps; Escherichia coli; Hand Disinfection; Quaternary Ammonium Compounds; Anti-Bacterial Agents; Staphylococcus aureus; Antiviral Agents; Polyethylenes; Skin; Surface-Active Agents; Humans; Fatty Acids; Time Factors; Orthomyxoviridae
PubMed: 38945924
DOI: 10.5650/jos.ess23266 -
Journal of Oleo Science 2024Herein, we evaluated friction dynamics of human skin treated with polyacrylic acid aqueous solutions or gel creams using a sinusoidal motion friction evaluation system...
Herein, we evaluated friction dynamics of human skin treated with polyacrylic acid aqueous solutions or gel creams using a sinusoidal motion friction evaluation system to demonstrate the effect of treatment with polymer aqueous solutions on human skin. A polymer aqueous solution or gel cream was applied to the inner forearms of 10 subjects to evaluate temporal changes in friction force under sinusoidal motion. Water content, skin viscoelasticity, and transepidermal water loss were also simultaneously measured to determine the effects on skin conditions. When human skin was treated with the polymer aqueous solution, the friction coefficient immediately after treatment was 0.69-0.99 and the delay time δ, a normalized parameter of the time difference in the delayed response of friction to the movement of the contact probe divided by the friction time T for one round trip, was 0.171-0.179, which was greater than that of untreated skin. This increase was caused by the swelling and softening of the stratum corneum caused by the penetration of water in the polymer aqueous solution, which increased true contact area between the skin and contact probe. A significant difference was observed in the friction coefficient of the skin immediately after treatment with different polymer aqueous solutions. Among polymers (P1-P4), P4, which has a low-salt resistance and low yield stress, had the lowest friction coefficient because of collapsing of the polymer network structures by shearing and reduced viscosity owing to salts on human skin. The skin treated with a gel cream also exhibited a greater friction coefficient than the untreated skin immediately after treatment and 90 min later. This phenomenon can be caused by the occlusive effect of the oil in the gel cream.
Topics: Humans; Friction; Water; Viscosity; Solutions; Acrylic Resins; Skin; Elasticity; Adult; Female; Male; Polymers; Skin Cream; Gels; Water Loss, Insensible
PubMed: 38945920
DOI: 10.5650/jos.ess24036 -
Dental Materials : Official Publication... Jun 2024To assess the effects of different aging protocols on chemical, physical, and mechanical properties of an experimental ATZ composite compared to a zirconia.
OBJECTIVES
To assess the effects of different aging protocols on chemical, physical, and mechanical properties of an experimental ATZ composite compared to a zirconia.
METHODS
Disc-shaped specimens were obtained through uniaxial pressing of commercial powders (Tosoh), ATZ comprised of 80%ZrO/20%AlO (TZ-3YS20AB) and 3Y-TZP (3Y-SBE). The specimens of each material were divided into different groups according to the aging protocol: immediate, autoclave aging and hydrothermal reactor aging. The aging protocols were performed at 134 ºC for 20 h at 2.2 bar. Crystalline evaluations were performed using X-Ray Diffraction. The nanoindentation tests measured the elastic modulus (Em) and hardness (H). Biaxial flexural strength was performed, and Weibull statistics were used to determine the characteristic strength and Weibull modulus. The probability of survival was also determined. The Em and H data were analyzed by one-way ANOVA and Tukey test.
RESULTS
Diffractograms revealed the presence of monoclinic phase in both materials after aging. The hydrothermal reactor decreased the Em for ATZ compared to its immediate condition; and the H for both ATZ and 3Y-TZP regarding their immediate and autoclave aging conditions, respectively. The aging protocols significantly increased the characteristic strength for ATZ, while decreased for 3Y-TZP. No difference regarding Weibull modulus was observed, except for 3Y-TZP aged in reactor. For missions of up to 500 MPa, both materials presented a high probability of survival (>99 %) irrespective of aging condition.
SIGNIFICANCE
The synthesized ATZ composite exhibited greater physical and microstructural stability compared to 3Y-TZP, supporting potential application of the experimental material for long-span reconstructive applications.
PubMed: 38945742
DOI: 10.1016/j.dental.2024.06.023 -
International Journal of Biological... Jun 2024Vulvovaginal candidiasis (VVC) is an opportunistic infection caused by a fungus of the Candida genus, affecting approximately 75 % of women during their lifetime....
Vulvovaginal candidiasis (VVC) is an opportunistic infection caused by a fungus of the Candida genus, affecting approximately 75 % of women during their lifetime. Fungal resistance cases and adverse effects have been the main challenges of oral therapies. In this study, the topical application of thin films containing fluconazole (FLU) and thymol (THY) was proposed to overcome these problems. Vaginal films based only on chitosan (CH) or combining this biopolymer with pectin (PEC) or hydroxypropylmethylcellulose acetate succinate (HPMCAS) were developed by the solvent casting method. In addition to a higher swelling index, CH/HPMCAS films showed to be more plastic and flexible than systems prepared with CH/PEC or only chitosan. Biopolymers and FLU were found in an amorphous state, contributing to explaining the rapid gel formation after contact with vaginal fluid. High permeability rates of FLU were also found after its immobilization into thin films. The presence of THY in polymer films increased the distribution of FLU in vaginal tissues and resulted in improved anti-Candida activity. A significant activity against the resistant C. glabrata was achieved, reducing the required FLU dose by 50 %. These results suggest that the developed polymer films represent a promising alternative for the treatment of resistant vulvovaginal candidiasis, encouraging further studies in this context.
PubMed: 38945715
DOI: 10.1016/j.ijbiomac.2024.133356 -
International Journal of Biological... Jun 2024The environmental pollution caused by plastic films urgently requires the development of non-toxic, biodegradable, and renewable biopolymer films. However, the poor...
The environmental pollution caused by plastic films urgently requires the development of non-toxic, biodegradable, and renewable biopolymer films. However, the poor waterproof and UV resistance properties of biopolymer films have limited their application in fruit packaging. In this work, a novel tannic acid cross-linked chitosan/gelatin film with hydrophobic silica coating (CGTS) was prepared. Relying on the adhesion of tannic acid and gelatin to silica, the coating endows CGTS film with excellent superhydrophobic properties. Especially, the contact angle reaches a maximum value 152.6°. Meanwhile, tannic acid enhanced the mechanical strength (about 36.1 %) through the forming of hydrogen bonding and the network structure. The prepared CGTS films showed almost zero transmittance to ultraviolet light and exhibited excellent radical scavenging ability (∼76.5 %, DPPH). Hence, CGTS film is suitable as a novel multifunctional packaging material for the agriculture to protect premature fruits, or the food industry used in environments exposed to ultraviolet radiation and rainwater.
PubMed: 38945712
DOI: 10.1016/j.ijbiomac.2024.133368 -
Applied Radiation and Isotopes :... Jun 2024In this study, we investigate the impact of zenith angle variations on cosmic-ray induced background in High-Purity Germanium (HPGe) gamma spectrometers using a...
In this study, we investigate the impact of zenith angle variations on cosmic-ray induced background in High-Purity Germanium (HPGe) gamma spectrometers using a coincidence technique based on plastic scintillator-Germanium detectors. We utilize an HPGe detector (Model GC2018 Mirion Ge Detector) enclosed within a low-activity cylindrical lead shield (Model 747E Mirion Lead Shield). For cosmic ray detection, a coincidence detection system with plastic scintillator detectors was positioned on top of the lead shielding. The zenith angle at the Germanium detector is computed using the dimensions of the square plastic scintillator and its distance from the Germanium detector center. We carried out measurements of cosmic-ray induced background in an HPGe gamma spectrometer with a square plastic configuration (80cm x 80cm), equivalent to a 45° zenith angle. The experimental measurements were compared with GEANT4 simulation data. The results demonstrate a good agreement between the measured energy spectrum and the simulated data across the energy range of 0.05 to 47 MeV. Further investigations into the effects of varying zenith angles provide valuable insights for optimizing HPGe spectrometer setups with minimized background interference.
PubMed: 38944899
DOI: 10.1016/j.apradiso.2024.111418