ChemSusChem Nov 2023The use of hydrocarbon-based proton conducting membranes in fuel cells is currently hampered by the insufficient durability of the material in the device. Membrane aging...
The use of hydrocarbon-based proton conducting membranes in fuel cells is currently hampered by the insufficient durability of the material in the device. Membrane aging is triggered by the presence of reactive intermediates, such as HO⋅, which attack the polymer and eventually lead to chain breakdown and membrane failure. An adequate antioxidant strategy tailored towards hydrocarbon-based ionomers is therefore imperative to improve membrane lifetime. In this work, we perform studies on reaction kinetics using pulse radiolysis and γ-radiolysis as well as fuel cell experiments to demonstrate the feasibility of increasing the stability of hydrocarbon-based membranes against oxidative attack by implementing a Nature-inspired antioxidant strategy. We found that metalated-porphyrins are suitable for damage transfer and can be used in the fuel cell membrane to reduce membrane aging with a low impact on fuel cell performance.
PubMed: 37551734
DOI: 10.1002/cssc.202300775 -
Medical Physics Nov 2023Hydrated electrons, which are short-lived products of radiolysis in water, increase the optical absorption of water, providing a pathway toward near-tissue-equivalent...
BACKGROUND
Hydrated electrons, which are short-lived products of radiolysis in water, increase the optical absorption of water, providing a pathway toward near-tissue-equivalent clinical radiation dosimeters. This has been demonstrated in high-dose-per-pulse radiochemistry research, but, owing to the weak absorption signal, its application in existing low-dose-per-pulse radiotherapy provided by clinical linear accelerators (linacs) has yet to be investigated.
PURPOSE
The aims of this study were to measure the optical absorption associated with hydrated electrons produced by clinical linacs and to assess the suitability of the technique for radiotherapy (⩽ 1 cGy per pulse) applications.
METHODS
40 mW of 660-nm laser light was sent five passes through deionized water contained in a 10 2 cm glass-walled cavity by using four broadband dielectric mirrors, two on each side of the cavity. The light was collected with a biased silicon photodetector. The water cavity was then irradiated by a Varian TrueBeam linac with both photon (10 MV FFF, 6 MV FFF, 6 MV) and electron beams (6 MeV) while monitoring the transmitted laser power for absorption transients. Radiochromic EBT3 film measurements were also performed for comparison.
RESULTS
Examination of the absorbance profiles showed clear absorption changes in the water when radiation pulses were delivered. Both the amplitude and the decay time of the signal appeared consistent with the absorbed dose and the characteristics of the hydrated electrons. By using literature value for the hydrated electron radiation chemical yield (3.0±0.3), we inferred doses of 2.1±0.2 mGy (10 MV FFF), 1.3±0.1 mGy (6 MV FFF), 0.45±0.06 mGy (6 MV) for photons, and 0.47±0.05 mGy (6 MeV) for electrons, which differed from EBT3 film measurements by 0.6%, 0.8%, 10%, and 15.7%, respectively. The half-life of the hydrated electrons in the solution was ∼ 24 s.
CONCLUSIONS
By measuring 660-nm laser light transmitted through a cm-scale, multi-pass water cavity, we observed absorption transients consistent with hydrated electrons generated by clinical linac radiation. The agreement between our inferred dose and EBT3 film measurements suggests this proof-of-concept system represents a viable pathway toward tissue-equivalent dosimeters for clinical radiotherapy applications.
Topics: Electrons; Radiation Dosimeters; Photons; Phantoms, Imaging; Particle Accelerators; Water; Radiotherapy Dosage; Radiometry
PubMed: 37334736
DOI: 10.1002/mp.16555 -
Journal of Hazardous Materials Sep 2023Recovery of platinum group metals (PGMs) including palladium (Pd), rhodium (Rh), and ruthenium (Ru) from high-level radioactive liquid waste (HLLW) possesses enormous...
Recovery of platinum group metals (PGMs) including palladium (Pd), rhodium (Rh), and ruthenium (Ru) from high-level radioactive liquid waste (HLLW) possesses enormous environmental and economic benefits. A non-contact photoreduction method was herein developed to selectively recover each PGM from HLLW. Soluble Pd(II), Rh(III), and Ru(III) ions were reduced to insoluble zero-valent metals and separated from simulated HLLW containing neodymium (Nd) as a representative for lanthanides, another main component in HLLW. Detailed investigation on the photoreduction of different PGMs revealed that Pd(II) could be reduced under 254- or 300-nm UV exposure using either ethanol or isopropanol as reductants. Only 300-nm UV light enabled the reduction of Rh(III) in the presence of ethanol or isopropanol. Ru(III) was the most difficult to reduce, which was only realized by 300-nm UV illumination in isopropanol solution. The effects of pH was also studied, suggesting that lower pH favored the separation of Rh(III) but hindered the reduction of Pd(II) and Ru(III). A delicate three-step process was accordingly designed to achieve the selective recovery of each PGM from simulated HLLW. Pd(II) was reduced by 254-nm UV light with the help of ethanol in the first step. Then Rh(III) was reduced by 300-UV light in the second step after the pH was adjusted to 0.5 to suppress the Ru(III) reduction. In the third step, Ru(III) was reduced by 300-nm UV light after isopropanol was added and the pH was adjusted to 3.2. The separation ratios of Pd, Rh, and Ru exceeded 99.8%, 99.9%, and 90.0%, respectively. Meanwhile, all Nd(III) still remained in the simulated HLLW. The separation coefficients between Pd/Rh and Rh/Ru exceeded 56,000 and 75,000, respectively. This work may provide an alternative method to recover PGMs from HLLW, which minimize the secondary radioactive wastes compared with other approaches.
PubMed: 37331059
DOI: 10.1016/j.jhazmat.2023.131852