-
Journal of Evolutionary Biology Jun 2024Comprehensive and systematic examination of Dengue virus (DENV) evolution is essential in the context of Pakistan as the virus presents a significant public health...
Comprehensive and systematic examination of Dengue virus (DENV) evolution is essential in the context of Pakistan as the virus presents a significant public health challenge with the ability to adapt and evolve. To shed light on intricate evolutionary patterns of all four DENV serotypes, we analyzed complete genome sequences (n=43) and envelope (E) gene sequences (n=44) of all four DENV serotypes collected in Pakistan from 1994 to 2023 providing a holistic view of their genetic evolution. Our findings revealed that all four serotypes of DENV co-circulate in Pakistan with a close evolutionary relationship between DENV-1 and DENV-3. Genetically distinct serotypes DENV-2 and DENV-4 indicate that DENV-4 stands out as the most genetically different, while DENV-2 exhibits greater complexity due to the presence of multiple genotypes and the possibility of temporal fluctuations in genotype prevalence. Selective pressure analysis in Envelope (E) gene revealed heterogeneity among sequences (n=44) highlighting 46 codons in the genome experiencing selective pressure, characterized by a bias towards balancing selection indicating genetic stability of the virus. Furthermore, our study suggested an intriguing evolutionary shift of DENV-4 towards the DENV-2 clade, potentially influenced by antibodies with cross-reactivity to multiple serotypes providing a critical insight into the complex factors shaping DENV evolution and contributing to the emergence of new serotype.
PubMed: 38943464
DOI: 10.1093/jeb/voae076 -
BMC Oral Health Jun 2024There are more than one million children and adolescents living with type 1 diabetes mellitus, and their number is steadily increasing. Diabetes affects oral health... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
There are more than one million children and adolescents living with type 1 diabetes mellitus, and their number is steadily increasing. Diabetes affects oral health through numerous channels, including hyposalivation, immune suppression, and the inflammatory effect of glycation end-products. However, patients with type 1 diabetes must follow a strict sugar free diet that is proven to be carioprotective. Therefore, the aim of this systematic review and meta-analysis is to investigate whether children with type 1 diabetes have a difference in Decayed, Missing, Filled Teeth index (DMFT), salivary function, and periodontal status than children without diabetes, with an emphasis on glycemic control.
MATERIALS AND METHODS
PubMed, Embase and Cochrane libraries were screened for articles, using predefined search keys without any language or date restrictions. Two independent authors performed the selection procedure, extracted data from the eligible articles, carried out a manual search of the reference lists, and assessed the risk of bias using the Newcastle-Ottawa scale. Meta-analysis was performed in R using the random-effects model. Effect sizes were mean differences; subgroup analysis was performed on glycemic control.
RESULTS
33 studies satisfied the eligibility criteria. 22 studies did not show a significant difference regarding the DMFT index between the diabetes and non-diabetes groups; six studies found that children living with diabetes had higher DMFT scores, compared to five studies that found significantly lower scores. Meta-analysis found no statistically significant differences in plaque, gingival, and calculus indexes, however it found significant differences in pooled DMFT indexes, and salivary flow rate. Subgroup analysis on glycemic control using DMFT values found significant differences in children with good and poor glycemic control with results of 0.26 (CI95%=-0.50; 1.03) and 1.46 (CI95%=0.57; 2.35), respectively.
CONCLUSIONS
Children with poor glycemic control face higher risk of developing caries compared to good control and non-diabetes children. Regular dental check-ups and strict control of glycemic levels are highly advised for children living with type 1 diabetes, further emphasizing the importance of cooperation between dentists and diabetologists.
Topics: Humans; Diabetes Mellitus, Type 1; Child; Oral Health; Glycemic Control; Adolescent; DMF Index
PubMed: 38943074
DOI: 10.1186/s12903-024-04516-y -
Surgical and Radiologic Anatomy : SRA Jun 2024Ultrasonography (US) has become an essential tool for guiding botulinum neurotoxin (BoNT) injections in facial muscles, enhancing precision and safety. This narrative... (Review)
Review
INTRODUCTION
Ultrasonography (US) has become an essential tool for guiding botulinum neurotoxin (BoNT) injections in facial muscles, enhancing precision and safety. This narrative review explores the role of US in BoNT administration, particularly in complex anatomical regions, highlighting its impact on treatment customization, real-time visualization, and complication reduction.
MATERIALS AND METHODS
A comprehensive literature search was conducted using PubMed, MEDLINE, Embase, and Cochrane Library for articles published from January 2018 to December 2023. Search terms included "Botulinum neurotoxin," "facial anatomy," "ultrasonography guided injection," and "facial muscle sonoanatomy." Studies focusing on US-guided BoNT injections in facial muscles were included. Data extraction and synthesis were performed independently by two reviewers, focusing on study design, ultrasonography techniques, outcomes, and conclusions.
RESULTS
The review found that US guidance significantly enhances the precision of BoNT injections by providing real-time visualization of facial muscles and blood vessels, thereby reducing the risk of adverse events. US enables tailored injection strategies, ensuring symmetrical facial expressions and minimizing over-treatment. The technique also offers immediate feedback, allowing for on-the-spot adjustments to improve treatment efficacy and safety. However, the review identified limitations, including potential selection bias and variability in US techniques across different studies.
CONCLUSION
US guidance for BoNT injections into facial muscles offers substantial benefits in terms of precision, safety, and treatment customization. Despite the identified limitations, the integration of US into clinical practice is poised to enhance patient outcomes in aesthetic and therapeutic procedures. Further research is needed to standardize US techniques and broaden the inclusivity of studies to validate these findings comprehensively.
PubMed: 38942935
DOI: 10.1007/s00276-024-03429-3 -
Scientific Reports Jun 2024Self-reported shorter/longer sleep duration, insomnia, and evening preference are associated with hyperglycaemia in observational analyses, with similar observations in...
Self-reported shorter/longer sleep duration, insomnia, and evening preference are associated with hyperglycaemia in observational analyses, with similar observations in small studies using accelerometer-derived sleep traits. Mendelian randomization (MR) studies support an effect of self-reported insomnia, but not others, on glycated haemoglobin (HbA1c). To explore potential effects, we used MR methods to assess effects of accelerometer-derived sleep traits (duration, mid-point least active 5-h, mid-point most active 10-h, sleep fragmentation, and efficiency) on HbA1c/glucose in European adults from the UK Biobank (UKB) (n = 73,797) and the MAGIC consortium (n = 146,806). Cross-trait linkage disequilibrium score regression was applied to determine genetic correlations across accelerometer-derived, self-reported sleep traits, and HbA1c/glucose. We found no causal effect of any accelerometer-derived sleep trait on HbA1c or glucose. Similar MR results for self-reported sleep traits in the UKB sub-sample with accelerometer-derived measures suggested our results were not explained by selection bias. Phenotypic and genetic correlation analyses suggested complex relationships between self-reported and accelerometer-derived traits indicating that they may reflect different types of exposure. These findings suggested accelerometer-derived sleep traits do not affect HbA1c. Accelerometer-derived measures of sleep duration and quality might not simply be 'objective' measures of self-reported sleep duration and insomnia, but rather captured different sleep characteristics.
Topics: Humans; Mendelian Randomization Analysis; Glycated Hemoglobin; Accelerometry; Sleep; Blood Glucose; Male; Female; Middle Aged; Adult; Self Report; Aged; Sleep Initiation and Maintenance Disorders
PubMed: 38942746
DOI: 10.1038/s41598-024-58007-9 -
The Lancet. Public Health Jul 2024Alcohol container labels might reduce population-level alcohol-related harms, but investigations of their effectiveness have varied in approach and quality. A systematic... (Review)
Review
Alcohol container labels might reduce population-level alcohol-related harms, but investigations of their effectiveness have varied in approach and quality. A systematic synthesis is needed to adjust for these differences and to yield evidence to inform policy. Our objectives were to establish the effects of alcohol container labels bearing one or more health warnings, standard drink information, or low-risk drinking guidance on alcohol consumption behaviour, knowledge of label message, and support for labels. We completed a systematic review according to Cochrane and synthesis without meta-analysis standards. We included all peer-reviewed studies and grey literature published from Jan 1, 1989, to March 6, 2024, in English, French, German, or Spanish that investigated the effects of alcohol container labels compared with no-label or existing label control groups in any population on alcohol consumption behaviour, knowledge of label message, or support for labels. Data were synthesised narratively as impact statements and assessed for risk of bias and certainty in the evidence. A protocol was preregistered (PROSPERO CRD42020168240). We identified 40 publications that studied 31 labels and generated 17 impact statements. 24 (60%) of 40 publications focused on consumption behaviour and we had low or very low certainty in 13 (59%) of 22 outcomes. Alcohol container labels bearing health warnings might slow the rate of alcohol consumption (low certainty), reduce alcoholic beverage selection (moderate certainty), reduce consumption during pregnancy (low certainty), and reduce consumption before driving (moderate certainty). Interventions with multiple types of rotating alcohol container labels likely substantially decrease alcohol use (moderate certainty) and reduce alcohol sales (high certainty). To the best of our knowledge, this is the first systematic review on multiple types of alcohol container labels assessing their effects for certainty in the evidence. Limitations included heterogeneity in label designs and outcome measurements. Alcohol container labels probably influence some alcohol consumption behaviour, with multiple rotating messages being particularly effective, although effects might vary depending on individual health literacy or drinking behaviour. Alcohol container labels might therefore be effective components of policies designed to address population-level alcohol-related harms.
Topics: Humans; Alcohol Drinking; Alcoholic Beverages; Product Labeling; Health Knowledge, Attitudes, Practice
PubMed: 38942559
DOI: 10.1016/S2468-2667(24)00097-5 -
Integrative and Comparative Biology Jun 2024To humans, the diverse array of display behaviors that animals use for communication can easily seem peculiar or bizarre. While ample research delves into the...
To humans, the diverse array of display behaviors that animals use for communication can easily seem peculiar or bizarre. While ample research delves into the evolutionary principles that shape these signals' effectiveness, little attention is paid to evolutionary patterning of signal design across taxa, particularly when it comes to the potential convergent evolution of many elaborate behavioral displays. By taking a mechanistic perspective, we explore the physiological and neurobiological mechanisms that likely influence the evolution of communication signals, emphasizing the utilization of pre-existing structures over novel adaptations. Central to this investigation are the concepts of perceptual bias and ritualization, which we propose contribute to the convergence of elaborate display designs across species. Perceptual bias explains a phenomenon where pre-existing perceptual systems of receivers, used for innate behaviors such as food and predator recognition, select for certain traits of a communication signal from a signaler. Ritualization occurs when traits with no functional role in communication are co-opted through selection and transformed into a new communicative signal. Importantly, susceptibility for ritualization can be brought about through physiological modifications that occurred early in evolutionary time. In this way, perceptual bias can be a selective force that causes the co-option of non-communicative traits into a new communication signal through ritualization involving pre-existing modifications to physiological systems. If the perceptual bias, non-communicative signal, and physiological modifications that increase susceptibility to ritualization are highly conserved, then we may see the convergent evolution of the new communication signal with unrelated taxa facing similar sensory constraints. We explore this idea here using the foot-flagging frog system as a theoretical case study.
PubMed: 38942486
DOI: 10.1093/icb/icae091 -
Archives of Physical Medicine and... Jun 2024This study aimed to assess the effectiveness of exercise therapy for Axial spondyloarthritis (axSpA) patients. (Review)
Review
OBJECTIVE
This study aimed to assess the effectiveness of exercise therapy for Axial spondyloarthritis (axSpA) patients.
DATA SOURCES
From the database inception to March 2024, we searched PubMed (via Medline), Cochrane Library, Embase, Web of Science, Scopus, and SPORTDiscus for all relevant publications without any language restriction.
STUDY SELECTION
We included randomized controlled trials (RCTs) for axSpA patients in which at least one group received exercise therapy.
DATA EXTRACTION
Two independent reviewers assessed the quality of the literature using the Cochrane Collaboration Risk of Bias Tool 2.0. The outcomes were ankylosing spondylitis (AS) disease activity score (ASDAS), Bath AS disease activity index (BASDAI), Bath AS functional index (BASFI), Bath AS metrology index (BASMI), 6-minute walk distance (6MWT), Chest expansion capacity, Peak oxygen consumption (VOpeak), pain, fatigue, C-reactive protein (CRP), and Eythrocyte sedimentation rate (ESR).
DATA SYNTHESIS
A total of 20 RCTs, including 1,670 patients, were included in this study. Compared with the control group, exercise therapy improved BASFI (weighted mean difference [WMD]: -0.49, 95% confidence interval [CI]: -0.65 to -0.32, I= 3.4%, P=0.414), BASMI (WMD: -0.49, 95% CI: -0.87 to -0.11, I= 71.9%, P=0.679), BASDAI (WMD: -0.78, 95% CI: -1.08, -0.47, I=55.9%, P=0.021), ASDAS (WMD: -0.44, 95% CI: -0.64 to -0.24, I =0.0%, P=0.424), VOpeak (WMD: 3.16, 95% CI: 1.37 to 4.94, I=0.0%, P=0.873), 6MWT (WMD: 27.64, 95% CI: 12.04 to 43.24, I= 0.0%, P=0.922), Pain (standardized mean difference [SMD]: -0.47, 95% CI: -0.74 to -0.21, I= 66.0%, P=0.046) and Fatigue (SMD: -0.49, 95% CI: -0.71 to -0.27, I= 0.0%, P=0.446). However, no significant benefit was found in Chest expansion, CRP, and ESR outcomes.
CONCLUSIONS
Exercise therapy is an effective strategy for improving disease control and symptom relief in axSpA.
PubMed: 38942347
DOI: 10.1016/j.apmr.2024.06.005 -
Clinical Neurology and Neurosurgery Jun 2024
Letter to the editor. "Surgical evacuation of spontaneous cerebellar hemorrhage: Comparison of safety and efficacy of suboccipital craniotomy and robotic-assisted stereotactic hematoma drainage".
PubMed: 38941710
DOI: 10.1016/j.clineuro.2024.108384 -
Emergency Radiology Jun 2024Pleural effusion is a very common clinical finding. Quantifying pleural effusion volume and its response to treatment over time has become increasingly important for... (Review)
Review
Pleural effusion is a very common clinical finding. Quantifying pleural effusion volume and its response to treatment over time has become increasingly important for clinicians, which is currently performed via computed tomography (CT) or drainage. To determine and compare ultrasonography (US), CT, and drainage agreements in pleural effusion volumetry. Protocol pre-registration was performed a priori at ( https://osf.io/rnugd/ ). We searched PubMed, Web of Science, Embase, and Cochrane Library for studies up to January 7, 2024. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2), QUADAS-C, and Consensus-based Standards for the selection of health Measurement Instruments (COSMIN). Volumetric performances of CT, US, and drainage in assessment of pleural effusion volume were evaluated through both aggregated data (AD) and individual participant data (IPD) analyses. Certainty of evidence was evaluated using Grading of Recommendations, Assessment, Development, and Evaluations (GRADE). Six studies were included with 446 pleural effusion lesions. AD results showed a perfect level of agreement with pooled Pearson correlation and intraclass correlation coefficient (ICC) of 0.933 and 0.948 between US and CT. IPD results demonstrated a high level of agreement between US and CT, with Finn's coefficient, ICC, concordance correlation coefficient (CCC), and Pearson correlation coefficient values of 0.856, 0.855, 0.854, and 0.860, respectively. Also, both results showed an overall perfect level of agreement between US and drainage. As for comparing the three combinations, US vs. CT and US vs. drainage were both superior to CT vs. drainage, suggesting the US is a good option for pleural effusion volumetric assessment. Ultrasound provides a highly reliable, to-the-point, cost-effective, and noninvasive method for the assessment of pleural effusion volume and is a great alternative to CT or drainage.
PubMed: 38941026
DOI: 10.1007/s10140-024-02252-y -
The Cochrane Database of Systematic... Jun 2024Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems.
OBJECTIVES
To assess the effectiveness of PICC material and design in reducing catheter failure and complications.
SEARCH METHODS
The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) evaluating PICC design and materials.
DATA COLLECTION AND ANALYSIS
We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE.
MAIN RESULTS
We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence).
AUTHORS' CONCLUSIONS
There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.
Topics: Humans; Randomized Controlled Trials as Topic; Catheterization, Peripheral; Catheter-Related Infections; Equipment Failure; Equipment Design; Venous Thromboembolism; Catheter Obstruction; Central Venous Catheters; Cause of Death; Bias; Catheterization, Central Venous; Bacteremia
PubMed: 38940297
DOI: 10.1002/14651858.CD013366.pub2