Heliyon May 2024The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive... (Review)
Review
The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive manufacturing on their physical and mechanical properties?" This review followed the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA 2020) and was registered in the Open Science Framework (OSF) (osf.io/rdc84). Searches were performed in PubMed, Scopus, Science Direct, Embase, and Google Scholar databases on February 17th, 2024. Articles were chosen in 2 steps by 2 blinded reviewers based on previously selected inclusion criteria: In vitro studies that evaluated the influence of the impression direction of titanium implants produced by additive manufacturing on their physical and mechanical properties were selected. Articles were excluded that (1) did not use additive technology to obtain the implants, 2) used surfaces other than titanium, 3) did not evaluate the direction of impression, 4) Studies with only in vivo analyses, clinical studies, systematic reviews, book chapters, short communications, conference abstracts, case reports, and personal opinions.). In the initial search, 581 results were found. Of this total, 108 were excluded for duplication and, after applying the eligibility criteria, 16 articles were included in the present review. The risk of bias was analyzed using the RoBDEMAT. The risk of bias was analyzed using the RoBDEMAT. In addition, the coefficient of interagreement of the reviewers (Cohen's Kappa) and the certainty of evidence by GRADE were analyzed. In general, different impression angles showed variations in the physical and mechanical characteristics of the groups evaluated, including roughness, tensile strength, hardness, and modulus of elasticity. While some impression orientations resulted in greater strength or hardness, others showed greater elasticity or lower surface roughness. These findings suggest that print orientation plays a significant role in determining material properties. It can be concluded that printing directions influence the physical and mechanical properties of titanium implants and the studies included showed that the 0°, 45°, and 90° directions are the most evaluated as they present lower probabilities of structural anisotropies and provide better results in their roughness, hardness, tensile and compressive strength.
PubMed: 38774089
DOI: 10.1016/j.heliyon.2024.e30108 -
The British Journal of Oral &... Jun 2024This systematic review aimed to evaluate results reported in the literature regarding the success rate of the titanium mesh technique for the placement of dental... (Review)
Review
This systematic review aimed to evaluate results reported in the literature regarding the success rate of the titanium mesh technique for the placement of dental implants. The topic focused on titanium mesh used as a physical barrier for ridge reconstruction in cases of partial or total edentulism. The authors conducted an electronic search of four databases up to October 2023. Six articles fulfilled the inclusion criteria and were analysed. A total of 100 titanium meshes with a minimum of 4.6 months follow up after surgery were studied, and 241 implants were placed. The review shows that the use of titanium mesh is a predictable method for the rehabilitation of complex atrophic sites. Further investigation generating long-term data is needed to confirm these findings.
Topics: Humans; Titanium; Surgical Mesh; Bone Regeneration; Dental Implantation, Endosseous; Dental Implants; Alveolar Ridge Augmentation; Guided Tissue Regeneration, Periodontal
PubMed: 38760261
DOI: 10.1016/j.bjoms.2024.04.005 -
Archives of Medical Science : AMS 2024Our goal was to systematically review the current evidence comparing the relative effectiveness of two maxillary sinus floor elevation (MSFE) approaches (internal and... (Review)
Review
Clinical evaluation of maxillary sinus floor elevation with or without bone grafts: a systematic review and meta-analysis of randomised controlled trials with trial sequential analysis.
INTRODUCTION
Our goal was to systematically review the current evidence comparing the relative effectiveness of two maxillary sinus floor elevation (MSFE) approaches (internal and external) without bone grafts with that of conventional/grafted MSFE in patients undergoing implantation in the posterior maxilla.
MATERIAL AND METHODS
Medical databases (PubMed/Medline, Embase, Web of Science, and Cochrane Library) were searched for randomised controlled trials published between January 1980 and May 2023. A manual search of implant-related journals was also performed. Studies published in English that reported the clinical outcomes of MSFE with or without bone material were included. The risk of bias was assessed using the Cochrane Handbook Risk Assessment Tool. Meta-analyses and trial sequence analyses were performed on the included trials. Meta-regression analysis was performed using pre-selected covariates to account for substantial heterogeneity. The certainty of evidence for clinical outcomes was assessed using GRADEpro GDT online (Guideline Development Tool).
RESULTS
Seventeen studies, including 547 sinuses and 696 implants, were pooled for the meta-analysis. The meta-analysis showed no statistically significant difference between MSFE without bone grafts and conventional MSFE in terms of the implant survival rate in the short term ( = 11, = 0%, risk difference (RD): 0.03, 95% confidence intervals (CI): -0.01-0.07, = 0.17, required information size (RIS) = 307). Although conventional MSFE had a higher endo-sinus bone gain ( = 13, = 89%, weighted mean difference (WMD): -1.24, 95% CI: -1.91- -0.57, = 0.0003, RIS = 461), this was not a determining factor in implant survival. No difference in perforation ( = 13, = 0%, RD = 0.03, 95% CI: -0.02-0.09, = 0.99, RIS = 223) and marginal bone loss ( = 4, = 0%, WMD = 0.05, 95% CI: -0.14-0.23, = 0.62, no RIS) was detected between the two groups using meta-analysis. The pooled results of the implant stability quotient between the two groups were not robust on sensitivity analysis. Because of the limited studies reporting on the visual analogue scale, surgical time, treatment costs, and bone density, qualitative analysis was conducted for these outcomes.
CONCLUSIONS
This systematic review revealed that both non-graft and grafted MSFE had high implant survival rates. Owing to the moderate strength of the evidence and short-term follow-up, the results should be interpreted with caution.
PubMed: 38757030
DOI: 10.5114/aoms/174648 -
Journal of Dentistry Jul 2024This systematic review evaluated the occlusal changes after loading with implant-supported single crowns. (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
This systematic review evaluated the occlusal changes after loading with implant-supported single crowns.
SOURCES
An electronic literature search was conducted in PubMed, Embase and Cochrane library for randomized (RCTs) or non-randomized controlled clinical trials (CCTs), with a minimum of 10 patients.
STUDY SELECTION
Studies reporting the occlusal force changes on implant-supported single crowns - with natural teeth as antagonist - measured at baseline and after loading periods were included. 4 CCTs including 133 ISCs in posterior sites were included for meta-analysis. All analyzed ISCs had no contact at a light bite and a light contact at a heavy bite in MIP at loading (baseline).
DATA
The relative occlusal forces (ROFs) of each implant-supported single crown (ISC) or control tooth (CT) were extracted. ROFs were defined as percentage of the total occlusal force of the entire dentition at maximum intercuspal position (MIP). A meta-analysis was conducted to compare the ROF changes at different follow-up periods and the weighted mean differences in ROF between ISCs and CTs were pooled and analyzed. The amount of change in ROF was significantly lower in 6 to 12 months after loading comparing the follow-up period between baseline and 6 month (p < 0.05). At baseline and 3-month follow-up, CTs presented significant higher ROF than ISCs (p < 0.05), while no significant difference was found after half year following.
CONCLUSIONS
This study showed that the ROF changes significantly over time after loading of ISCs. It might prove that the occlusal concept defined at the time of prosthetic delivery changes or adapts naturally over time.
CLINICAL SIGNIFICANCE
The function of specific implant occlusal concept (no contact at a light bite and a light contact at a heavy bite in MIP) is limited over time and careful monitoring and occlusal adjustments should be recommendable during the first-year follow-up.
Topics: Humans; Crowns; Bite Force; Dental Prosthesis, Implant-Supported; Dental Implants, Single-Tooth; Follow-Up Studies; Dental Occlusion
PubMed: 38734300
DOI: 10.1016/j.jdent.2024.105000 -
Journal of Dentistry Jul 2024This review aimed to map taxonomy frameworks, descriptions, and applications of immersive technologies in the dental literature. (Review)
Review
OBJECTIVES
This review aimed to map taxonomy frameworks, descriptions, and applications of immersive technologies in the dental literature.
DATA
The Preferred reporting items for systematic reviews and meta-analyses extension for scoping reviews (PRISMA-ScR) guidelines was followed, and the protocol was registered at open science framework platform (https://doi.org/10.17605/OSF.IO/H6N8M).
SOURCES
Systematic search was conducted in MEDLINE (via PubMed), Scopus, and Cochrane Library databases, and complemented by manual search.
STUDY SELECTION
A total of 84 articles were included, with 81 % between 2019 and 2023. Most studies were experimental (62 %), including education (25 %), protocol feasibility (20 %), in vitro (11 %), and cadaver (6 %). Other study types included clinical report/technique article (24 %), clinical study (9 %), technical note/tip to reader (4 %), and randomized controlled trial (1 %). Three-quarters of the included studies were published in oral and maxillofacial surgery (38 %), dental education (26 %), and implant (12 %) disciplines. Methods of display included head mounted display device (HMD) (55 %), see through screen (32 %), 2D screen display (11 %), and projector display (2 %). Descriptions of immersive realities were fragmented and inconsistent with lack of clear taxonomy framework for the umbrella and the subset terms including virtual reality (VR), augmented reality (AR), mixed reality (MR), augmented virtuality (AV), extended reality, and X reality.
CONCLUSIONS
Immersive reality applications in dentistry are gaining popularity with a notable surge in the number of publications in the last 5 years. Ambiguities are apparent in the descriptions of immersive realities. A taxonomy framework based on method of display (full or partial) and reality class (VR, AR, or MR) is proposed.
CLINICAL SIGNIFICANCE
Understanding different reality classes can be perplexing due to their blurred boundaries and conceptual overlapping. Immersive technologies offer novel educational and clinical applications. This domain is fast developing. With the current fragmented and inconsistent terminologies, a comprehensive taxonomy framework is necessary.
Topics: Humans; Dentistry; Classification; Education, Dental; Virtual Reality; Augmented Reality
PubMed: 38729286
DOI: 10.1016/j.jdent.2024.105058 -
Digital Health 2024The integration of advanced technologies, including three-dimensional (3D) imaging modalities and virtual simulations, has significantly influenced contemporary... (Review)
Review
AIM
The integration of advanced technologies, including three-dimensional (3D) imaging modalities and virtual simulations, has significantly influenced contemporary approaches to preoperative planning in implant dentistry. Through a meticulous analysis of relevant studies, this review synthesizes findings related to accuracy outcomes in implant placement facilitated by 3D imaging in virtual patients.
METHODS
A comprehensive literature search was conducted across relevant databases to identify relevant studies published to date. The inclusion criteria were studies utilizing 3D imaging techniques, virtual patients, and those focusing on the accuracy of dental implant planning and surgical placement. The selected studies were critically appraised for their methodological quality.
RESULTS
After a rigorous analysis, 21 relevant articles were included out of 3021 articles. This study demonstrates the versatility and applicability of these technologies in both and settings. Integrating Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), cone bean computed tomography (CBCT), and advanced 3D reconstruction methodologies showcases a trend toward enhanced precision in implant planning and placement. Notably, the evaluation parameters varied, encompassing distances, discrepancies, and deviations in the implant placement. The ongoing integration of systems such as dynamic navigation systems, augmented reality, and sophisticated software platforms shows a promising trajectory for the continued refinement of virtual reality applications in dental implantology, providing valuable insights for future research and clinical implementation. Moreover, using stereolithographic surgical guides, virtual planning with CBCT data, and 3D-printed templates consistently demonstrates enhanced precision in dental implant placement compared to traditional methods.
CONCLUSION
The synthesis of the available evidence underscores the substantial positive impact of 3D imaging techniques and virtual patients on dental implant planning and surgical placement accuracy. Utilizing these technologies contributes to a more personalized and precise approach that enhances overall treatment outcomes. Future research directions and potential refinements to the application of these technologies in clinical practice should be discussed.
PubMed: 38726220
DOI: 10.1177/20552076241253550 -
Dental Materials : Official Publication... Jun 2024Nanotechnology is constantly advancing in dental science, progressing several features aimed at improving dental implants. An alternative for surface treatment of dental... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
Nanotechnology is constantly advancing in dental science, progressing several features aimed at improving dental implants. An alternative for surface treatment of dental implants is electrochemical anodization, which may generate a nanotubular surface (TiO nanotubes) with antibacterial potential and osteoinductive features. This systematic review and meta-analysis aims to elucidate the possible antibacterial properties of the surface in question compared to the untreated titanium surface.
SOURCES
For that purpose, was performed a systematic search on the bases PubMed, Lilacs, Embase, Web Of Science, Cinahl, and Cochrane Central, as well as, manual searches and gray literature.
STUDY SELECTION
The searches resulted in 742 articles, of which 156 followed for full-text reading. Then, 37 were included in the systematic review and 8 were included in meta-analysis.
RESULTS
Fifteen studies revealed significant antibacterial protection using TiO nanotube surfaces, while 15 studies found no statistical difference between control and nanotextured surfaces. Meta-analysis of in vitro studies demonstrated relevant bacterial reduction only for studies investigating Staphylococcus aureus in a period of 6 h. Meta-analysis of in vivo studies revealed three times lower bacterial adhesion and proliferation on TiO nanotube surfaces.
CONCLUSIONS
TiO nanotube topography as a surface for dental implants in preclinical research has demonstrated a positive relationship with antibacterial properties, nevertheless, factors such as anodization protocols, bacteria strains, and mono-culture methods should be taken into consideration, consequently, further studies are necessary to promote clinical translatability.
Topics: Titanium; Nanotubes; Dental Implants; Surface Properties; Anti-Bacterial Agents; Bacterial Adhesion; Humans; Staphylococcus aureus
PubMed: 38714394
DOI: 10.1016/j.dental.2024.04.009 -
Journal of Applied Biomaterials &... 2024Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs)... (Review)
Review
Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs) are more appropriate. This study's objective was to analyze the available research on full-ceramic RBFDPs. In this study, Web of Science, MEDLINE/PubMed, Scopus, Embase, Cochrane Library, and Google Scholar databases were searched for articles published in English between 2010 and 2020. A total of 14 studies were reviewed based on the eligibility criteria. The results showed that using a cantilever design with one abutment had an advantage over two abutments. Additionally, it was proposed that preparations designed with retentive aids, such as a proximal box, groove, and pinhole, could improve RBFDP survival rates. IPS e.max ZirCAD, In-Ceram alumina, and zirconia CAD/CAM were the most commonly used framework materials. Most studies used air abrasion, salinization, or hydrofluoric acid for surface treatment. Adhesive resin cements were the most frequently used type of cement. The survival rate of In-Ceram ceramics (85.3%-94.8%) was lower than that of In-Ceram zirconia and IPS e.max ZirCAD. Debonding, followed by framework fracture, was the leading cause of failure. Following 3-10 years follow-up, the survival percentage of all-ceramic RBFDPs ranged from 76% to 100%. Although RBFDPs have demonstrated satisfactory success as a conservative treatment, long-term follow-ups and higher sample sizes in clinical research are required to gain more reliable outcomes on the clinical success rate of various RBFDP designs.
Topics: Humans; Ceramics; Resin Cements; Dental Porcelain; Dental Prosthesis, Implant-Supported; Denture, Partial, Fixed, Resin-Bonded; Zirconium
PubMed: 38706266
DOI: 10.1177/22808000241250118 -
Avicenna Journal of Medicine Jan 2024Breast cancer is one of the most lethal neoplasms causing death. Oral cavity is the rare site of distant metastasis from breast cancer. Very little research has been... (Review)
Review
Breast cancer is one of the most lethal neoplasms causing death. Oral cavity is the rare site of distant metastasis from breast cancer. Very little research has been conducted to date to analyze breast cancer as the sole primary source of metastasis to the oral soft tissues. The goal of this study was to examine the published cases of oral soft tissue metastasis from breast cancer as the only primary source to date. An electronic search of the published literature was performed without publication year limitation in PubMed/Medline, Scopus, Google Scholar, Web of Science, Science Direct, Embase, and Research Gate databases, using mesh keywords like ("Breast cancer", OR "Breast carcinoma") AND ("Metastasis" OR "Metastases"), And ("Oral soft tissues" OR "Tongue" OR "Palate" OR "Tonsil" OR "Buccal mucosa" OR "Floor of mouth" OR "Vestibule" OR "Salivary glands"). We also searched all related journals manually. The reference list of all articles was also checked. Our research revealed 88 relevant papers (September 1967-September 2023) with 96 patients in total. The most predominant oral soft tissues involved were salivary glands followed by the gingiva, tonsils, tongue, and buccal mucosa. A total of 23% of patients died with an average survival time of 1 to 15 months. Oral soft tissue metastasis from breast cancer is a rare event and has a bad prognosis. More cases need to be published to raise awareness of these lesions.
PubMed: 38694143
DOI: 10.1055/s-0044-1779674 -
International Journal of Implant... May 2024The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific... (Review)
Review
PURPOSE
The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific focus on scan bodies (ISBs).
METHODS
Following the PRISMA 2020 guidelines, this study conducted a thorough electronic search across MedLine, PubMed, and Scopus to identify relevant studies. Articles were screened based on titles, abstracts, and full texts for relevance. The Robins I tool assessed the risk of bias in various study types. Data extraction occurred based on predetermined parameters for studying specimens and assessing outcomes.
RESULTS
16 studies met the specified criteria and were consequently included in the systematic review. Due to variations in variables and methods across the selected studies, statistical comparison of results was not feasible. Therefore, a descriptive review approach was chosen, acknowledging the substantial heterogeneity in the reviewed literature.
CONCLUSIONS
The precision of virtual scan results is contingent upon diverse characteristics of ISBs and implants. These factors encompass their placement within the dental arch, structural design, shape, material composition, color, and the manufacturing system, all of which contribute to scan accuracy. Additionally, considerations such as the intraoral scanner (IOS) type, scanning technique, use of scan aids, inter-implant distance, scan span, and the number of implants warrant evaluation. In the context of capturing implant positions, intraoral scanning with ISBs demonstrates comparable accuracy to traditional impression methods, particularly in single and short-span scenarios. However, the existing data lacks sufficient information on in vivo applications to formulate clinical recommendations.
Topics: Humans; Dental Implants; Imaging, Three-Dimensional; Computer-Aided Design; Dental Implantation, Endosseous; Dental Prosthesis Design
PubMed: 38691258
DOI: 10.1186/s40729-024-00543-0