Farmacia Hospitalaria : Organo Oficial... 2024The off-label use in clinical practice of non-approved syringes for intravitreal drug administration has resulted in the detection of silicone oil drops in the vitreous... (Review)
Review
OBJECTIVE
The off-label use in clinical practice of non-approved syringes for intravitreal drug administration has resulted in the detection of silicone oil drops in the vitreous of some patients. This situation derives from the lack of approved syringes for intraocular use in the Spanish market. The aim of this work is to review the use of syringes for intraocular administration, as well as to search for alternatives that meet the legal requirements for these unmet needs.
METHOD
A systematic review was performed following the PRISMA 2020 Guidelines by searching PubMed with the descriptors: "silicone" AND "syringes" AND ("intraocular" OR "intravitreal") and filtering all existing publications from January 2006 to December 2023, including all those articles dealing with silicone oil release in intravitreal injections and analysing the possible consequences.
RESULTS
Sixty-eight results were found, 23 of which were excluded because they did not deal with the subject under study, leaving a total of 45 articles for the systematic review. These were classified according to the conclusions obtained in 4 groups: the adverse reactions produced by silicone, the administration technique, the physicochemical aspects of silicone release, and the characteristics of the medical device. After reviewing the current manufacturers and technical data sheets of commercialized syringes, the existing syringes for this use have been collected, finding two that will probably be commercialized in Spain at the beginning of 2024: Zero Residual™ 0.2 ml SiO-free and VitreJect® Ophthalmic.
CONCLUSIONS
From the results obtained, it can be interpreted that the use of syringes and needles with silicone for intravitreal use is a concern for health professionals due to the implications and consequences that may arise in patients, the most important being adverse reactions, so it is necessary to have silicone-free syringes on the market that are specific for intraocular use. Safety and legality in the use of intraocular syringes and needles is essential to guarantee ocular integrity and patient health.
Topics: Syringes; Humans; Silicone Oils; Intravitreal Injections; Off-Label Use; Spain
PubMed: 38556370
DOI: 10.1016/j.farma.2024.01.008 -
Drug Discovery Today May 2024The ocular thin film presents a potential solution for addressing challenges to ocular drug delivery. In this review, we summarise the findings of a comprehensive review... (Meta-Analysis)
Meta-Analysis Review
The ocular thin film presents a potential solution for addressing challenges to ocular drug delivery. In this review, we summarise the findings of a comprehensive review analysing 336 formulations from 68 studies. We investigated the physical and mechanical properties of ocular thin films, categorised into natural polymer-based, synthetic polymer-based, and combined polymer films. The results showed that the type of polymers used impacted mucoadhesion force, moisture absorption:moisture loss ratio, pH, swelling index, and elongation percentage. Significant relationships were found between these properties within each subgroup. The results also highlighted the influence of plasticisers on elongation percentage, mucoadhesion force, swelling index, and moisture absorption:moisture loss ratio. These findings have implications for designing and optimising ocular drug formulations and selecting appropriate plasticisers to achieve formulations with the desired properties.
Topics: Humans; Polymers; Drug Delivery Systems; Administration, Ophthalmic; Eye; Animals
PubMed: 38552779
DOI: 10.1016/j.drudis.2024.103964 -
Polymers Mar 2024Poly-L-lactic acid (PLLA) implants have been used for bone fixation for decades. However, upon insertion, they can cause a foreign body reaction (FBR) that may lead to... (Review)
Review
Poly-L-lactic acid (PLLA) implants have been used for bone fixation for decades. However, upon insertion, they can cause a foreign body reaction (FBR) that may lead to complications. On 15 December 2023, a systematic review was conducted to search for articles on the PubMed, MeSH term, and Scopus databases using the keywords 'PLLA' and 'foreign body reaction'. The articles were reviewed not only for the question of FBR, its severity, and the manifestation of symptoms but also for the type of implant and its location in the body, the species, and the number of individuals included. A total of 71 original articles were identified. Of these, two-thirds reported on in vivo trials, and one-third reported on clinical applications. The overall majority of the reactions were mild in more than half of the investigations. Symptoms of extreme and extensive FBR mainly include osteolysis, ganglion cysts, and swelling. The localization of PLLA implants in bone can often result in osteolysis due to local acidosis. This issue can be mitigated by adding hydroxyapatite. There should be no strong FBR when PLLA is fragmented to 0.5-4 µm by extracorporeal shock wave.
PubMed: 38543422
DOI: 10.3390/polym16060817 -
The Journal of Hospital Infection May 2024Bacteria commonly adhere to surfaces and produce polymeric material to encase the attached cells to form communities called biofilms. Within these biofilms, bacteria can... (Review)
Review
Bacteria commonly adhere to surfaces and produce polymeric material to encase the attached cells to form communities called biofilms. Within these biofilms, bacteria can appear to be many times more resistant to antibiotics or disinfectants. This systematic review explores the prevalence and microbial profile associated with biofilm production of bacteria isolated from endotracheal tubes and its associations with antimicrobial resistance. A comprehensive search was performed on databases PubMed, Embase, and Google Scholar for relevant articles published between 1 January 2000 and 31 December 2022. The relevant articles were exported to Mendeley Desktop 1.19.8 and screened by title and abstract, followed by full text screening based on the eligibility criteria of the study. Quality assessment of the studies was performed using the Newcastle-Ottawa Scale (NOS) customized for cross-sectional studies. Furthermore, the prevalence of antimicrobial resistance in biofilm-producers isolated from endotracheal tube specimens was investigated. Twenty studies encompassing 981 endotracheal tubes met the eligibility criteria. Pseudomonas spp. and Acinetobacter spp. were predominant isolates among the biofilm producers. These biofilms provided strong resistance against commonly used antibiotics. The highest resistance rate observed in Pseudomonas spp. was against fluoroquinolones whereas the least resistance was seen against piperacillin-tazobactam. A similar trend of susceptibility was observed in Acinetobacter spp. with a very high resistance rate against fluoroquinolones, third-generation cephalosporins and carbapenems. In conclusion, endotracheal tubes were associated with colonization by biofilm forming bacteria with varying levels of antimicrobial resistance. Biofilms may promote the occurrence of recalcitrant infections in endotracheal tubes which need to be managed with appropriate protocols and antimicrobial stewardship. Research focus should shift towards meticulous exploration of biofilm-associated infections to improve detection and management.
Topics: Biofilms; Humans; Intubation, Intratracheal; Drug Resistance, Bacterial; Anti-Bacterial Agents; Bacteria
PubMed: 38522561
DOI: 10.1016/j.jhin.2024.03.004 -
Toxicology Reports Jun 2024PAE and PC polymers, such as BPA, are utilized to make water bottles. Due to the lack of polymer-chemical interaction, PAE can enter drinking bottles during production,... (Review)
Review
PAE and PC polymers, such as BPA, are utilized to make water bottles. Due to the lack of polymer-chemical interaction, PAE can enter drinking bottles during production, wrapping, and keeping. Phthalates can transfer from the bottle to the water depending on keeping conditions (temperature, time, sunlight intensity), pH, and bottle capacity. Since there haven't been previous studies published on the subject, the aim of this meta-analysis and systematic review research is to determine the level of phthalates in drinking water consumed in Iranian cities. Web of Science, Science of Direct, Scopus, and PubMed, databases have been used in this study. Eight studies were selected from 556 initial publications after screening for duplication and irrelevant information. Articles from January 1, 2000, to February 10, 2024, were found in the mentioned databases. Among the types of phthalates, the concentration of DEHP was reported higher than the others Because its concentration has been reported in seven out of eight studies. The highest concentration of DEHP was reported by Mehraie(2.22 µg/l), Zare Jeddi (0.8 µg/l), Yousefi (0.77 µg/l), Abtahi (0.76 µg/l), Zare Jeddi (0.42 µg/l), Abdolahnejad(0.15 µg/l), and Pourzamani (0.08 µg/l). The highest concentration of DEP, DBP, BBP, and PA was reported by Abtahi (0.77 µg/l) and Esteki (2.25 µg/l), Mehraie(0.93 µg/l), and Pourzamani (0.83 µg/l). The results of this study showed that the most important phthalates measured in drinking water include DEP, DEHP, DBP, BBP, and PA. According to the results of the present studies, the most important factor in the increase of phthalates is the storage conditions of drinking water (temperature, sunlight, and the type of pipe or bottle).
PubMed: 38495472
DOI: 10.1016/j.toxrep.2024.02.009 -
Polymers Feb 2024In recent years, composite resin materials have been the most frequently used materials for direct restorations of posterior teeth. These materials have some clinically... (Review)
Review
In recent years, composite resin materials have been the most frequently used materials for direct restorations of posterior teeth. These materials have some clinically relevant limitations due to their lack of fracture toughness, especially when used in larger cavities with high volume factors or when utilized as direct or indirect overlays or crown restorations. Recently, short-fiber-reinforced composite materials have been used in bi-structure restorations as a dentine substituting material due to their superior mechanical properties; however, there is no scientific consensus as to whether they can be used as full restorations. The aim of our review was to examine the available literature and gather scientific evidence on this matter. Two independent authors performed a thorough literature search using PubMed and ScienceDirect up until December 2023. This study followed the PRISMA guidelines, and the risk of bias was assessed using the QUIN tool. The authors selected in vitro studies that used short-fiber-reinforced composite materials as complete restorations, with a conventional composite material as a comparison group. Out of 2079 potentially relevant articles, 16 met our inclusion criteria. All of the included studies reported that the usage of short-fiber-reinforced composites improved the restoration's load-bearing capacity. Fifteen of the included publications examined the fracture pattern, and thirteen of them reported a more favorable fracture outcome for the short-fiber-reinforced group. Only one article reported a more favorable fracture pattern for the control group; however, the difference between groups was not significant. Within the limitations of this review, the evidence suggests that short-fiber-reinforced composites can be used effectively as complete restorations to reinforce structurally compromised teeth.
PubMed: 38475274
DOI: 10.3390/polym16050590 -
Chirurgia (Bucharest, Romania : 1990) Feb 2024Chronic postoperative inguinal pain (CPIP) is still the most frequent complication after open Lichtenstein repair and any strategy to reduce its incidence and... (Meta-Analysis)
Meta-Analysis
The Effectiveness of Cyanoacrylates versus Sutures for Mesh Fixation after Lichtenstein Repair (SCyMeLi STUDY) A Systematic Review and Meta-Analyze of Randomized Controlled Trials.
Chronic postoperative inguinal pain (CPIP) is still the most frequent complication after open Lichtenstein repair and any strategy to reduce its incidence and implications is a step forward to better outcomes. Between the means of mesh fixation atraumatic glue fixation has been explored as such possibility. A meta-analysis of randomized controlled trials comparing the performance of cyanoacrylate glue versus sutures fixation was conducted. the meta-analysis was conducted according to the PRISMA guidelines. Randomized controlled trials (RCTs) published between January 2000 and December 2021 were searched for in MEDLINE, PubMed, Web of Science, and Google Scholars. The quality of RCTs and the potential risk of bias were assessed using MINORS criteria and the Cochrane risk of bias tool. of 269 papers the meta-analysis was performed on 19 RCTs including 3578 patients. In the glue fixation group, the operation was shorter (mean pooled difference 6 minutes; SE = 0.47; 95% CI = - 6.77 - - 4.92; t test = -12.36; p 0.0001) and immediate postoperative pain was lower (2.37% vs 13.3%OR - 0.158; 95% CI = 0.064 0.386; p = 0.0001). There was no difference in terms of chronic pain, recurrence rate and wound events. Conclusion: glue fixation of mesh in elective Lichtenstein repair of inguinal hernia seems to be a valid choice for a painful and safe procedure without increasing risk of recurrence.
Topics: Humans; Cyanoacrylates; Surgical Mesh; Treatment Outcome; Randomized Controlled Trials as Topic; Pain, Postoperative; Chronic Pain; Sutures; Hernia, Inguinal; Herniorrhaphy; Recurrence
PubMed: 38465719
DOI: 10.21614/chirurgia.2024.v.119.i.1.p.87 -
Hepatology International Jun 2024The identification of reliable predictors for hepatitis B surface antigen (HBsAg) seroclearance remains controversial. We aimed to summarize potential predictors for... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND AND AIMS
The identification of reliable predictors for hepatitis B surface antigen (HBsAg) seroclearance remains controversial. We aimed to summarize potential predictors for HBsAg seroclearance by pegylated interferon-α (PegIFNα) in patients with chronic HBV infection.
METHODS
A systematic search of the Cochrane Library, Embase, PubMed, and Web of Science databases was conducted from their inception to 28 September 2022. Meta-analyses were performed following the PRISMA statement. Predictors of HBsAg seroclearance were evaluated based on baseline characteristics and on-treatment indicators.
RESULTS
This meta-analysis encompasses 27 studies, including a total of 7913 patients. The findings reveal several factors independently associated with HBsAg seroclearance induced by PegIFNα-based regimens. These factors include age (OR = 0.961), gender (male vs. female, OR = 0.537), genotype (A vs. B/D; OR = 7.472, OR = 10.738), treatment strategy (combination vs. monotherapy, OR = 2.126), baseline HBV DNA (OR = 0.414), baseline HBsAg (OR = 0.373), HBsAg levels at week 12 and 24 (OR = 0.384, OR = 0.294), HBsAg decline from baseline to week 12 and 24 (OR = 6.689, OR = 6.513), HBsAg decline from baseline ≥ 1 log IU/ml and ≥ 0.5 log IU/ml at week 12 (OR = 18.277; OR = 4.530), and ALT elevation at week 12 (OR = 3.622). Notably, subgroup analysis suggests no statistical association between HBsAg levels at week 12 and HBsAg seroclearance for treatment duration exceeding 48 weeks. The remaining results were consistent with the overall analysis.
CONCLUSIONS
This is the first meta-analysis to identify predictors of HBsAg seroclearance with PegIFNα-based regimens, including baseline and on-treatment factors, which is valuable in developing a better integrated predictive model for HBsAg seroclearance to guide individualized treatment and achieve the highest cost-effectiveness of PegIFNα.
Topics: Humans; Interferon-alpha; Hepatitis B, Chronic; Hepatitis B Surface Antigens; Antiviral Agents; Polyethylene Glycols; Hepatitis B virus
PubMed: 38461186
DOI: 10.1007/s12072-024-10648-8 -
Cancer Treatment Reviews Apr 2024Cancer-related pain often requires opioid treatment with opioid-induced constipation (OIC) as its most frequent gastrointestinal side-effect. Both for prevention and... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Cancer-related pain often requires opioid treatment with opioid-induced constipation (OIC) as its most frequent gastrointestinal side-effect. Both for prevention and treatment of OIC osmotic (e.g. polyethylene glycol) and stimulant (e.g. bisacodyl) laxatives are widely used. Newer drugs such as the peripherally acting µ-opioid receptor antagonists (PAMORAs) and naloxone in a fixed combination with oxycodone have become available for the management of OIC. This systematic review and meta-analysis aims to give an overview of the scientific evidence on pharmacological strategies for the prevention and treatment of OIC in cancer patients.
METHODS
A systematic search in PubMed, Embase, Web of Science and the Cochrane Library was completed from inception up to 22 October 2022. Randomized and non-randomized studies were systematically selected. Bowel function and adverse drug events were assessed.
RESULTS
Twenty trials (prevention: five RCTs and three cohort studies; treatment: ten RCTs and two comparative cohort studies) were included in the review. Regarding the prevention of OIC, three RCTs compared laxatives with other laxatives, finding no clear differences in effectivity of the laxatives used. One cohort study showed a significant benefit of magnesium oxide compared with no laxative. One RCT found a significant benefit for the PAMORA naldemedine compared with magnesium oxide. Preventive use of oxycodone/naloxone did not show a significant difference in two out of three other studies compared to oxycodone or fentanyl. A meta-analysis was not possible. Regarding the treatment of OIC, two RCTs compared laxatives, of which one RCT found that polyethylene glycol was significantly more effective than sennosides. Seven studies compared an opioid antagonist (naloxone, methylnaltrexone or naldemedine) with placebo and three studies compared different dosages of opioid antagonists. These studies with opioid antagonists were used for the meta-analysis. Oxycodone/naloxone showed a significant improvement in Bowel Function Index compared to oxycodone with laxatives (MD -13.68; 95 % CI -18.38 to -8.98; I = 58 %). Adverse drug event rates were similar amongst both groups, except for nausea in favour of oxycodone/naloxone (RR 0.51; 95 % CI 0.31-0.83; I = 0 %). Naldemedine (NAL) and methylnaltrexone (MNTX) demonstrated significantly higher response rates compared to placebo (NAL: RR 2.07, 95 % CI 1.64-2.61, I = 0 %; MNTX: RR 3.83, 95 % CI 2.81-5.22, I = 0 %). With regard to adverse events, abdominal pain was more present in treatment with methylnaltrexone and diarrhea was significantly more present in treatment with naldemedine. Different dosages of methylnaltrexone were not significantly different with regard to both efficacy and adverse drug event rates.
CONCLUSIONS
Magnesium oxide and naldemedine are most likely effective for prevention of OIC in cancer patients. Naloxone in a fixed combination with oxycodone, naldemedine and methylnaltrexone effectively treat OIC in cancer patients with acceptable adverse events. However, their effect has not been compared to standard (osmotic and stimulant) laxatives. More studies comparing standard laxatives with each other and with opioid antagonists are necessary before recommendations for clinical practice can be made.
Topics: Humans; Laxatives; Analgesics, Opioid; Narcotic Antagonists; Constipation; Oxycodone; Opioid-Induced Constipation; Magnesium Oxide; Cohort Studies; Naloxone; Polyethylene Glycols; Neoplasms; Drug-Related Side Effects and Adverse Reactions; Quaternary Ammonium Compounds; Naltrexone
PubMed: 38452708
DOI: 10.1016/j.ctrv.2024.102704 -
BMC Ophthalmology Mar 2024Polyethylene covers have been proven to be effective in protecting the eyes in patients with decreased or disappeared blink reflexes, but their advantages compared to... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Polyethylene covers have been proven to be effective in protecting the eyes in patients with decreased or disappeared blink reflexes, but their advantages compared to other conventional methods are still unclear. This systematic review and meta-analysis study aimed to elucidate the impact of polyethylene covers in the prevention of ocular surface disease (OSD) in patients admitted to the intensive care unit (ICU).
METHODS
We searched the Scopus, PubMed, Web of Science, and Cochrane Central Register of Controlled Trials (CENTRAL) databases to identify randomized controlled trial studies. This study followed the PRISMA guidelines and used the Cochrane Collaboration tool to assess the risk of bias.
RESULTS
The findings were expressed as risk ratio (RR) with 95% confidence intervals. The incidence of OSD in the polyethylene cover group was lower than that in the eye drops group (RR = 0.27; 95% CI (0.07, 1.09), P = 0.07) and adhesive tape group (RR = 0.11, 95%CI (0.04, 0.31), P < 0:0001) but the polyethylene cover group showed no significant difference compared to the eye gel group (RR = 0.79, 95%CI (0.18, 3.51), P = 0.76) and the eye ointment group (RR = 0.85; 95% CI (0.36, 1.99), P = 0.71).
CONCLUSION
This study showed that polyethylene covers, eye gels, and eye ointments had an equal effect on preventing OSD in ICU patients, and eye drops and adhesive tapes were relatively less effective. However, other intervention methods had not been compared due to the small number of articles. Hence, further studies should assess the available methods to choose the best practical method.
Topics: Humans; Polyethylene; Eye Diseases; Eye; Intensive Care Units; Ophthalmic Solutions
PubMed: 38448859